Manchester code (phase encoding) library.
Dependents: Manchester_Transmitter Manchester_Receiver
Manchester code (phase encoding) library
It implements Manchester code according to both IEEE 802.3 and G.E. Thomas' conventions.
- A '0' is expressed by a high-to-low transition, a '1' by low-to-high transition in the IEEE 802.3 convention. The reverse is true in the G.E. Thomas' convention.
- The transitions which signify '0' or '1' occur at the midpoint of a period.
- Transitions at the start of a period are overhead and don't signify data.
- Least significant bit is sent first
- There are synchronization pulses (the number can be set) at the begin of transmission
Select a convention to be used by commenting or uncommenting the line below in theManchester.h
header file.
Manchester.h
#define G_E_THOMAS 1
The IEEE 802.3 convention is used by default.
A Manchester encoded message (using G.E. Thomas' convention), with one sync pulse in the preamble, carrying four bytes:
ACKNOWLEDGEMENT: The code in this library was based on this article published by Robert Guastella.
Import programManchester_Transmitter
Manchester transmitter demo.
Import programManchester_Receiver
Manchester receiver demo.
NOTE: To perform a simple test (without radio modules) connect the txPin on transmitter board to the rxPin on the receiver board and make sure that grounds are also connected one another.
Revisions of Manchester.h
Revision | Date | Message | Actions |
---|---|---|---|
8:c1b5893191fe | 2018-10-14 | Number of sync pulses in preamble can be set. | File Diff Annotate |
6:7454ad91f714 | 2017-05-22 | Updated. | File Diff Annotate |
5:3b2c7e9fda3f | 2017-05-21 | Added IEEE 802.3 convention. | File Diff Annotate |
2:de778df5892c | 2017-05-17 | Updated. | File Diff Annotate |
1:11292d238e50 | 2017-05-17 | Updated. | File Diff Annotate |