Central Heating controller using the real time clock, PHY module for internet, 1-wire interface for temperature sensors, a system log and a configuration file
Dependencies: net 1-wire lpc1768 crypto clock web fram log
/media/uploads/andrewboyson/heating.sch
/media/uploads/andrewboyson/heating.brd
/media/uploads/andrewboyson/eagle.epf
http-derived/boiler/http-boiler-html.c@24:e3ed1b52c6e6, 2019-01-17 (annotated)
- Committer:
- andrewboyson
- Date:
- Thu Jan 17 13:42:54 2019 +0000
- Revision:
- 24:e3ed1b52c6e6
- Child:
- 34:18a3fc737899
Updated http-base library
Who changed what in which revision?
User | Revision | Line number | New contents of line |
---|---|---|---|
andrewboyson | 24:e3ed1b52c6e6 | 1 | #include "http.h" |
andrewboyson | 24:e3ed1b52c6e6 | 2 | #include "page.h" |
andrewboyson | 24:e3ed1b52c6e6 | 3 | #include "page-derived.h" |
andrewboyson | 24:e3ed1b52c6e6 | 4 | #include "boiler.h" |
andrewboyson | 24:e3ed1b52c6e6 | 5 | #include "ds18b20.h" |
andrewboyson | 24:e3ed1b52c6e6 | 6 | #include "http-server.h" |
andrewboyson | 24:e3ed1b52c6e6 | 7 | |
andrewboyson | 24:e3ed1b52c6e6 | 8 | void HttpBoilerHtml() |
andrewboyson | 24:e3ed1b52c6e6 | 9 | { |
andrewboyson | 24:e3ed1b52c6e6 | 10 | HttpOk("text/html; charset=UTF-8", "no-cache", NULL, NULL); |
andrewboyson | 24:e3ed1b52c6e6 | 11 | PageAddHeader(PageSite, "Boiler", "settings.css", NULL); |
andrewboyson | 24:e3ed1b52c6e6 | 12 | PageAddNav(BOILER_PAGE); |
andrewboyson | 24:e3ed1b52c6e6 | 13 | PageAddH1(PageSite, "Boiler"); |
andrewboyson | 24:e3ed1b52c6e6 | 14 | |
andrewboyson | 24:e3ed1b52c6e6 | 15 | int16_t temp; |
andrewboyson | 24:e3ed1b52c6e6 | 16 | char text[DS18B20_VALUE_STRING_LENGTH]; |
andrewboyson | 24:e3ed1b52c6e6 | 17 | temp = DS18B20ValueFromRom(BoilerGetTankRom()); DS18B20ValueToString(temp, text); PageAddLabelledValue("Tank", 10, text); |
andrewboyson | 24:e3ed1b52c6e6 | 18 | temp = DS18B20ValueFromRom(BoilerGetOutputRom()); DS18B20ValueToString(temp, text); PageAddLabelledValue("Boiler output", 10, text); |
andrewboyson | 24:e3ed1b52c6e6 | 19 | temp = DS18B20ValueFromRom(BoilerGetReturnRom()); DS18B20ValueToString(temp, text); PageAddLabelledValue("Boiler return", 10, text); |
andrewboyson | 24:e3ed1b52c6e6 | 20 | |
andrewboyson | 24:e3ed1b52c6e6 | 21 | PageAddH2("Parameters"); |
andrewboyson | 24:e3ed1b52c6e6 | 22 | PageAddIntInput("/boiler", 0, "Tank set point", 10, "tanksetpoint", 2, BoilerGetTankSetPoint()); |
andrewboyson | 24:e3ed1b52c6e6 | 23 | PageAddIntInput("/boiler", 0, "Tank hysteresis", 10, "tankhysteresis", 2, BoilerGetTankHysteresis()); |
andrewboyson | 24:e3ed1b52c6e6 | 24 | PageAddIntInput("/boiler", 0, "Boiler run on residual", 10, "boilerresidual", 2, BoilerGetRunOnResidual()); |
andrewboyson | 24:e3ed1b52c6e6 | 25 | PageAddIntInput("/boiler", 0, "Boiler run on time", 10, "boilerrunon", 2, BoilerGetRunOnTime()); |
andrewboyson | 24:e3ed1b52c6e6 | 26 | |
andrewboyson | 24:e3ed1b52c6e6 | 27 | PageAddH2("Outputs"); |
andrewboyson | 24:e3ed1b52c6e6 | 28 | PageAddLabelledOnOff("Boiler call", 10, BoilerCall); |
andrewboyson | 24:e3ed1b52c6e6 | 29 | PageAddLabelledOnOff("Boiler pump", 10, BoilerPump); |
andrewboyson | 24:e3ed1b52c6e6 | 30 | |
andrewboyson | 24:e3ed1b52c6e6 | 31 | PageAddEnd(); |
andrewboyson | 24:e3ed1b52c6e6 | 32 | |
andrewboyson | 24:e3ed1b52c6e6 | 33 | } |