Central Heating controller using the real time clock, PHY module for internet, 1-wire interface for temperature sensors, a system log and a configuration file

Dependencies:   net 1-wire lpc1768 crypto clock web fram log

/media/uploads/andrewboyson/heating.sch

/media/uploads/andrewboyson/heating.brd

/media/uploads/andrewboyson/eagle.epf

http-derived/boiler/http-boiler-html.c

Committer:
andrewboyson
Date:
2019-01-17
Revision:
24:e3ed1b52c6e6
Child:
34:18a3fc737899

File content as of revision 24:e3ed1b52c6e6:

#include "http.h"
#include "page.h"
#include "page-derived.h"
#include "boiler.h"
#include "ds18b20.h"
#include "http-server.h"

void HttpBoilerHtml()
{
    HttpOk("text/html; charset=UTF-8", "no-cache", NULL, NULL);
    PageAddHeader(PageSite, "Boiler", "settings.css", NULL);
    PageAddNav(BOILER_PAGE);
    PageAddH1(PageSite, "Boiler");
    
    int16_t temp;
    char text[DS18B20_VALUE_STRING_LENGTH];
    temp = DS18B20ValueFromRom(BoilerGetTankRom());    DS18B20ValueToString(temp, text); PageAddLabelledValue("Tank",          10, text);
    temp = DS18B20ValueFromRom(BoilerGetOutputRom());  DS18B20ValueToString(temp, text); PageAddLabelledValue("Boiler output", 10, text);
    temp = DS18B20ValueFromRom(BoilerGetReturnRom());  DS18B20ValueToString(temp, text); PageAddLabelledValue("Boiler return", 10, text);
    
    PageAddH2("Parameters");
    PageAddIntInput("/boiler", 0, "Tank set point",         10, "tanksetpoint",   2, BoilerGetTankSetPoint());
    PageAddIntInput("/boiler", 0, "Tank hysteresis",        10, "tankhysteresis", 2, BoilerGetTankHysteresis());
    PageAddIntInput("/boiler", 0, "Boiler run on residual", 10, "boilerresidual", 2, BoilerGetRunOnResidual());
    PageAddIntInput("/boiler", 0, "Boiler run on time",     10, "boilerrunon",    2, BoilerGetRunOnTime());
    
    PageAddH2("Outputs");
    PageAddLabelledOnOff("Boiler call", 10, BoilerCall);
    PageAddLabelledOnOff("Boiler pump", 10, BoilerPump);

    PageAddEnd();
    
}