Microsoft Azure IoTHub client MQTT transport
Dependents: STM32F746_iothub_client_sample_mqtt FXOS8700CQ_To_Azure_IoT f767zi_mqtt FXOS8700CQ_To_Azure_IoT ... more
iothubtransportmqtt.c@9:50744bd8239e, 2016-09-09 (annotated)
- Committer:
- AzureIoTClient
- Date:
- Fri Sep 09 13:37:32 2016 -0700
- Revision:
- 9:50744bd8239e
- Parent:
- 8:418a3b812584
- Child:
- 10:c61c16bb63e6
1.0.10
Who changed what in which revision?
User | Revision | Line number | New contents of line |
---|---|---|---|
Azure.IoT Build | 0:5e72a75c31b8 | 1 | // Copyright (c) Microsoft. All rights reserved. |
Azure.IoT Build | 0:5e72a75c31b8 | 2 | // Licensed under the MIT license. See LICENSE file in the project root for full license information. |
Azure.IoT Build | 0:5e72a75c31b8 | 3 | |
Azure.IoT Build | 0:5e72a75c31b8 | 4 | #include <stdlib.h> |
Azure.IoT Build | 0:5e72a75c31b8 | 5 | #ifdef _CRTDBG_MAP_ALLOC |
Azure.IoT Build | 0:5e72a75c31b8 | 6 | #include <crtdbg.h> |
Azure.IoT Build | 0:5e72a75c31b8 | 7 | #endif |
Azure.IoT Build | 1:f2e563755d91 | 8 | #include "azure_c_shared_utility/gballoc.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 9 | |
Azure.IoT Build | 5:73603e7a6542 | 10 | #include "azure_c_shared_utility/xlogging.h" |
Azure.IoT Build | 1:f2e563755d91 | 11 | #include "azure_c_shared_utility/strings.h" |
Azure.IoT Build | 1:f2e563755d91 | 12 | #include "azure_c_shared_utility/doublylinkedlist.h" |
Azure.IoT Build | 1:f2e563755d91 | 13 | #include "azure_c_shared_utility/crt_abstractions.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 14 | |
Azure.IoT Build | 0:5e72a75c31b8 | 15 | #include "iothub_client_ll.h" |
AzureIoTClient | 8:418a3b812584 | 16 | #include "iothub_client_options.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 17 | #include "iothub_client_private.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 18 | #include "iothubtransportmqtt.h" |
Azure.IoT Build | 1:f2e563755d91 | 19 | #include "azure_umqtt_c/mqtt_client.h" |
Azure.IoT Build | 1:f2e563755d91 | 20 | #include "azure_c_shared_utility/sastoken.h" |
Azure.IoT Build | 1:f2e563755d91 | 21 | #include "azure_c_shared_utility/tickcounter.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 22 | |
Azure.IoT Build | 1:f2e563755d91 | 23 | #include "azure_c_shared_utility/tlsio.h" |
Azure.IoT Build | 1:f2e563755d91 | 24 | #include "azure_c_shared_utility/platform.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 25 | |
AzureIoTClient | 2:9db4da50abaa | 26 | #include "azure_c_shared_utility/string_tokenizer.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 27 | #include "iothub_client_version.h" |
Azure.IoT Build | 0:5e72a75c31b8 | 28 | |
Azure.IoT Build | 0:5e72a75c31b8 | 29 | #include <stdarg.h> |
Azure.IoT Build | 0:5e72a75c31b8 | 30 | #include <stdio.h> |
Azure.IoT Build | 0:5e72a75c31b8 | 31 | |
AzureIoTClient | 6:16875b609849 | 32 | #include <limits.h> |
AzureIoTClient | 6:16875b609849 | 33 | |
Azure.IoT Build | 0:5e72a75c31b8 | 34 | #define SAS_TOKEN_DEFAULT_LIFETIME 3600 |
AzureIoTClient | 2:9db4da50abaa | 35 | #define SAS_REFRESH_MULTIPLIER .8 |
Azure.IoT Build | 0:5e72a75c31b8 | 36 | #define EPOCH_TIME_T_VALUE 0 |
Azure.IoT Build | 1:f2e563755d91 | 37 | #define DEFAULT_MQTT_KEEPALIVE 4*60 // 4 min |
Azure.IoT Build | 0:5e72a75c31b8 | 38 | #define DEFAULT_PORT_NUMBER 8883 |
Azure.IoT Build | 0:5e72a75c31b8 | 39 | #define DEFAULT_TEMP_STRING_LEN 256 |
Azure.IoT Build | 0:5e72a75c31b8 | 40 | #define BUILD_CONFIG_USERNAME 24 |
Azure.IoT Build | 0:5e72a75c31b8 | 41 | #define EVENT_TOPIC_DEFAULT_LEN 27 |
Azure.IoT Build | 0:5e72a75c31b8 | 42 | #define SAS_TOKEN_DEFAULT_LEN 10 |
Azure.IoT Build | 0:5e72a75c31b8 | 43 | #define RESEND_TIMEOUT_VALUE_MIN 1*60 |
Azure.IoT Build | 0:5e72a75c31b8 | 44 | #define MAX_SEND_RECOUNT_LIMIT 2 |
AzureIoTClient | 2:9db4da50abaa | 45 | #define DEFAULT_CONNECTION_INTERVAL 30 |
AzureIoTClient | 2:9db4da50abaa | 46 | #define FAILED_CONN_BACKOFF_VALUE 5 |
AzureIoTClient | 2:9db4da50abaa | 47 | |
AzureIoTClient | 2:9db4da50abaa | 48 | static const char* DEVICE_MSG_TOPIC = "devices/%s/messages/devicebound/#"; |
AzureIoTClient | 2:9db4da50abaa | 49 | static const char* DEVICE_DEVICE_TOPIC = "devices/%s/messages/events/"; |
AzureIoTClient | 2:9db4da50abaa | 50 | static const char* PROPERTY_SEPARATOR = "&"; |
AzureIoTClient | 2:9db4da50abaa | 51 | |
AzureIoTClient | 2:9db4da50abaa | 52 | typedef struct SYSTEM_PROPERTY_INFO_TAG |
AzureIoTClient | 2:9db4da50abaa | 53 | { |
AzureIoTClient | 4:e472f5ce3473 | 54 | const char* propName; |
AzureIoTClient | 4:e472f5ce3473 | 55 | size_t propLength; |
AzureIoTClient | 2:9db4da50abaa | 56 | } SYSTEM_PROPERTY_INFO; |
AzureIoTClient | 2:9db4da50abaa | 57 | |
AzureIoTClient | 2:9db4da50abaa | 58 | static SYSTEM_PROPERTY_INFO sysPropList[] = { |
AzureIoTClient | 4:e472f5ce3473 | 59 | { "%24.exp", 7 }, |
AzureIoTClient | 4:e472f5ce3473 | 60 | { "%24.mid", 7 }, |
AzureIoTClient | 4:e472f5ce3473 | 61 | { "%24.uid", 7 }, |
AzureIoTClient | 4:e472f5ce3473 | 62 | { "%24.to", 6 }, |
AzureIoTClient | 4:e472f5ce3473 | 63 | { "%24.cid", 7 }, |
AzureIoTClient | 4:e472f5ce3473 | 64 | { "devices/", 8 }, |
AzureIoTClient | 4:e472f5ce3473 | 65 | { "iothub-operation", 16 }, |
AzureIoTClient | 4:e472f5ce3473 | 66 | { "iothub-ack", 10 } |
AzureIoTClient | 2:9db4da50abaa | 67 | }; |
Azure.IoT Build | 0:5e72a75c31b8 | 68 | |
AzureIoTClient | 4:e472f5ce3473 | 69 | static TICK_COUNTER_HANDLE g_msgTickCounter; |
Azure.IoT Build | 0:5e72a75c31b8 | 70 | |
AzureIoTClient | 7:7fdd306e6224 | 71 | typedef enum MQTT_TRANSPORT_CREDENTIAL_TYPE_TAG |
AzureIoTClient | 7:7fdd306e6224 | 72 | { |
AzureIoTClient | 7:7fdd306e6224 | 73 | CREDENTIAL_NOT_BUILD, |
AzureIoTClient | 7:7fdd306e6224 | 74 | X509, |
AzureIoTClient | 7:7fdd306e6224 | 75 | SAS_TOKEN_FROM_USER, |
AzureIoTClient | 7:7fdd306e6224 | 76 | DEVICE_KEY, |
AzureIoTClient | 7:7fdd306e6224 | 77 | } MQTT_TRANSPORT_CREDENTIAL_TYPE; |
AzureIoTClient | 7:7fdd306e6224 | 78 | |
AzureIoTClient | 7:7fdd306e6224 | 79 | typedef struct MQTT_TRANSPORT_CREDENTIALS_TAG |
AzureIoTClient | 7:7fdd306e6224 | 80 | { |
AzureIoTClient | 7:7fdd306e6224 | 81 | MQTT_TRANSPORT_CREDENTIAL_TYPE credential_type; |
AzureIoTClient | 7:7fdd306e6224 | 82 | union |
AzureIoTClient | 7:7fdd306e6224 | 83 | { |
AzureIoTClient | 7:7fdd306e6224 | 84 | // Key associated to the device to be used. |
AzureIoTClient | 7:7fdd306e6224 | 85 | STRING_HANDLE deviceKey; |
AzureIoTClient | 7:7fdd306e6224 | 86 | |
AzureIoTClient | 7:7fdd306e6224 | 87 | // SAS associated to the device to be used. |
AzureIoTClient | 7:7fdd306e6224 | 88 | STRING_HANDLE deviceSasToken; |
AzureIoTClient | 7:7fdd306e6224 | 89 | |
AzureIoTClient | 7:7fdd306e6224 | 90 | } CREDENTIAL_VALUE; |
AzureIoTClient | 7:7fdd306e6224 | 91 | } MQTT_TRANSPORT_CREDENTIALS; |
AzureIoTClient | 7:7fdd306e6224 | 92 | |
Azure.IoT Build | 0:5e72a75c31b8 | 93 | typedef struct MQTTTRANSPORT_HANDLE_DATA_TAG |
Azure.IoT Build | 0:5e72a75c31b8 | 94 | { |
AzureIoTClient | 4:e472f5ce3473 | 95 | STRING_HANDLE device_id; |
AzureIoTClient | 7:7fdd306e6224 | 96 | STRING_HANDLE devicesPath; |
AzureIoTClient | 7:7fdd306e6224 | 97 | |
AzureIoTClient | 7:7fdd306e6224 | 98 | MQTT_TRANSPORT_CREDENTIALS transport_creds; |
AzureIoTClient | 7:7fdd306e6224 | 99 | |
AzureIoTClient | 4:e472f5ce3473 | 100 | STRING_HANDLE mqttEventTopic; |
AzureIoTClient | 4:e472f5ce3473 | 101 | STRING_HANDLE mqttMessageTopic; |
AzureIoTClient | 4:e472f5ce3473 | 102 | STRING_HANDLE hostAddress; |
AzureIoTClient | 4:e472f5ce3473 | 103 | // The current mqtt iothub implementation requires that the hub name and the domain suffix be passed as the first of a series of segments |
AzureIoTClient | 4:e472f5ce3473 | 104 | // passed through the username portion of the connection frame. |
AzureIoTClient | 4:e472f5ce3473 | 105 | // The second segment will contain the device id. The two segments are delemited by a "/". |
AzureIoTClient | 4:e472f5ce3473 | 106 | // The first segment can be a maximum 256 characters. |
AzureIoTClient | 4:e472f5ce3473 | 107 | // The second segment can be a maximum 128 characters. |
AzureIoTClient | 4:e472f5ce3473 | 108 | // With the / delimeter you have 384 chars (Plus a terminator of 0). |
AzureIoTClient | 4:e472f5ce3473 | 109 | STRING_HANDLE configPassedThroughUsername; |
AzureIoTClient | 4:e472f5ce3473 | 110 | int portNum; |
AzureIoTClient | 4:e472f5ce3473 | 111 | MQTT_CLIENT_HANDLE mqttClient; |
AzureIoTClient | 4:e472f5ce3473 | 112 | uint16_t packetId; |
AzureIoTClient | 4:e472f5ce3473 | 113 | bool isRegistered; |
AzureIoTClient | 4:e472f5ce3473 | 114 | bool connected; |
AzureIoTClient | 4:e472f5ce3473 | 115 | bool subscribed; |
AzureIoTClient | 4:e472f5ce3473 | 116 | bool receiveMessages; |
AzureIoTClient | 4:e472f5ce3473 | 117 | bool destroyCalled; |
AzureIoTClient | 4:e472f5ce3473 | 118 | DLIST_ENTRY waitingForAck; |
AzureIoTClient | 4:e472f5ce3473 | 119 | PDLIST_ENTRY waitingToSend; |
AzureIoTClient | 4:e472f5ce3473 | 120 | IOTHUB_CLIENT_LL_HANDLE llClientHandle; |
AzureIoTClient | 4:e472f5ce3473 | 121 | CONTROL_PACKET_TYPE currPacketState; |
AzureIoTClient | 4:e472f5ce3473 | 122 | XIO_HANDLE xioTransport; |
AzureIoTClient | 6:16875b609849 | 123 | uint16_t keepAliveValue; |
AzureIoTClient | 4:e472f5ce3473 | 124 | uint64_t mqtt_connect_time; |
AzureIoTClient | 4:e472f5ce3473 | 125 | size_t connectFailCount; |
AzureIoTClient | 4:e472f5ce3473 | 126 | uint64_t connectTick; |
Azure.IoT Build | 0:5e72a75c31b8 | 127 | } MQTTTRANSPORT_HANDLE_DATA, *PMQTTTRANSPORT_HANDLE_DATA; |
Azure.IoT Build | 0:5e72a75c31b8 | 128 | |
Azure.IoT Build | 0:5e72a75c31b8 | 129 | typedef struct MQTT_MESSAGE_DETAILS_LIST_TAG |
Azure.IoT Build | 0:5e72a75c31b8 | 130 | { |
AzureIoTClient | 4:e472f5ce3473 | 131 | uint64_t msgPublishTime; |
AzureIoTClient | 4:e472f5ce3473 | 132 | size_t retryCount; |
AzureIoTClient | 4:e472f5ce3473 | 133 | IOTHUB_MESSAGE_LIST* iotHubMessageEntry; |
AzureIoTClient | 4:e472f5ce3473 | 134 | void* context; |
AzureIoTClient | 4:e472f5ce3473 | 135 | uint16_t msgPacketId; |
AzureIoTClient | 4:e472f5ce3473 | 136 | DLIST_ENTRY entry; |
Azure.IoT Build | 0:5e72a75c31b8 | 137 | } MQTT_MESSAGE_DETAILS_LIST, *PMQTT_MESSAGE_DETAILS_LIST; |
Azure.IoT Build | 0:5e72a75c31b8 | 138 | |
AzureIoTClient | 6:16875b609849 | 139 | static uint16_t get_next_packet_id(PMQTTTRANSPORT_HANDLE_DATA transportState) |
AzureIoTClient | 6:16875b609849 | 140 | { |
AzureIoTClient | 6:16875b609849 | 141 | if (transportState->packetId+1 >= USHRT_MAX) |
AzureIoTClient | 6:16875b609849 | 142 | { |
AzureIoTClient | 6:16875b609849 | 143 | transportState->packetId = 1; |
AzureIoTClient | 6:16875b609849 | 144 | } |
AzureIoTClient | 6:16875b609849 | 145 | else |
AzureIoTClient | 6:16875b609849 | 146 | { |
AzureIoTClient | 6:16875b609849 | 147 | transportState->packetId++; |
AzureIoTClient | 6:16875b609849 | 148 | } |
AzureIoTClient | 6:16875b609849 | 149 | return transportState->packetId; |
AzureIoTClient | 6:16875b609849 | 150 | } |
AzureIoTClient | 6:16875b609849 | 151 | |
Azure.IoT Build | 5:73603e7a6542 | 152 | static void sendMsgComplete(IOTHUB_MESSAGE_LIST* iothubMsgList, PMQTTTRANSPORT_HANDLE_DATA transportState, IOTHUB_CLIENT_CONFIRMATION_RESULT confirmResult) |
Azure.IoT Build | 0:5e72a75c31b8 | 153 | { |
AzureIoTClient | 4:e472f5ce3473 | 154 | DLIST_ENTRY messageCompleted; |
AzureIoTClient | 4:e472f5ce3473 | 155 | DList_InitializeListHead(&messageCompleted); |
AzureIoTClient | 4:e472f5ce3473 | 156 | DList_InsertTailList(&messageCompleted, &(iothubMsgList->entry)); |
Azure.IoT Build | 5:73603e7a6542 | 157 | IoTHubClient_LL_SendComplete(transportState->llClientHandle, &messageCompleted, confirmResult); |
Azure.IoT Build | 0:5e72a75c31b8 | 158 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 159 | |
AzureIoTClient | 2:9db4da50abaa | 160 | static STRING_HANDLE addPropertiesTouMqttMessage(IOTHUB_MESSAGE_HANDLE iothub_message_handle, const char* eventTopic) |
AzureIoTClient | 2:9db4da50abaa | 161 | { |
AzureIoTClient | 4:e472f5ce3473 | 162 | STRING_HANDLE result = STRING_construct(eventTopic); |
AzureIoTClient | 4:e472f5ce3473 | 163 | const char* const* propertyKeys; |
AzureIoTClient | 4:e472f5ce3473 | 164 | const char* const* propertyValues; |
AzureIoTClient | 4:e472f5ce3473 | 165 | size_t propertyCount; |
AzureIoTClient | 2:9db4da50abaa | 166 | |
AzureIoTClient | 4:e472f5ce3473 | 167 | // Construct Properties |
AzureIoTClient | 4:e472f5ce3473 | 168 | MAP_HANDLE properties_map = IoTHubMessage_Properties(iothub_message_handle); |
AzureIoTClient | 4:e472f5ce3473 | 169 | if (properties_map != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 170 | { |
AzureIoTClient | 4:e472f5ce3473 | 171 | if (Map_GetInternals(properties_map, &propertyKeys, &propertyValues, &propertyCount) != MAP_OK) |
AzureIoTClient | 4:e472f5ce3473 | 172 | { |
AzureIoTClient | 4:e472f5ce3473 | 173 | LogError("Failed to get the internals of the property map."); |
AzureIoTClient | 4:e472f5ce3473 | 174 | STRING_delete(result); |
AzureIoTClient | 4:e472f5ce3473 | 175 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 176 | } |
AzureIoTClient | 4:e472f5ce3473 | 177 | else |
AzureIoTClient | 4:e472f5ce3473 | 178 | { |
AzureIoTClient | 4:e472f5ce3473 | 179 | if (propertyCount != 0) |
AzureIoTClient | 4:e472f5ce3473 | 180 | { |
AzureIoTClient | 4:e472f5ce3473 | 181 | for (size_t index = 0; index < propertyCount && result != NULL; index++) |
AzureIoTClient | 4:e472f5ce3473 | 182 | { |
AzureIoTClient | 4:e472f5ce3473 | 183 | size_t len = strlen(propertyKeys[index]) + strlen(propertyValues[index]) + 2; |
AzureIoTClient | 4:e472f5ce3473 | 184 | char* propValues = malloc(len+1); |
AzureIoTClient | 4:e472f5ce3473 | 185 | if (propValues == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 186 | { |
AzureIoTClient | 4:e472f5ce3473 | 187 | STRING_delete(result); |
AzureIoTClient | 4:e472f5ce3473 | 188 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 189 | } |
AzureIoTClient | 4:e472f5ce3473 | 190 | else |
AzureIoTClient | 4:e472f5ce3473 | 191 | { |
AzureIoTClient | 4:e472f5ce3473 | 192 | sprintf(propValues, "%s=%s%s", propertyKeys[index], propertyValues[index], propertyCount - 1 == index ? "" : "&"); |
AzureIoTClient | 4:e472f5ce3473 | 193 | if (STRING_concat(result, propValues) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 194 | { |
AzureIoTClient | 4:e472f5ce3473 | 195 | STRING_delete(result); |
AzureIoTClient | 4:e472f5ce3473 | 196 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 197 | } |
AzureIoTClient | 4:e472f5ce3473 | 198 | free(propValues); |
AzureIoTClient | 4:e472f5ce3473 | 199 | } |
AzureIoTClient | 4:e472f5ce3473 | 200 | } |
AzureIoTClient | 4:e472f5ce3473 | 201 | } |
AzureIoTClient | 4:e472f5ce3473 | 202 | } |
AzureIoTClient | 4:e472f5ce3473 | 203 | } |
AzureIoTClient | 4:e472f5ce3473 | 204 | return result; |
AzureIoTClient | 2:9db4da50abaa | 205 | } |
AzureIoTClient | 2:9db4da50abaa | 206 | |
Azure.IoT Build | 0:5e72a75c31b8 | 207 | static int publishMqttMessage(PMQTTTRANSPORT_HANDLE_DATA transportState, MQTT_MESSAGE_DETAILS_LIST* mqttMsgEntry, const unsigned char* payload, size_t len) |
Azure.IoT Build | 0:5e72a75c31b8 | 208 | { |
AzureIoTClient | 4:e472f5ce3473 | 209 | int result; |
AzureIoTClient | 6:16875b609849 | 210 | mqttMsgEntry->msgPacketId = get_next_packet_id(transportState); |
AzureIoTClient | 4:e472f5ce3473 | 211 | STRING_HANDLE msgTopic = addPropertiesTouMqttMessage(mqttMsgEntry->iotHubMessageEntry->messageHandle, STRING_c_str(transportState->mqttEventTopic)); |
AzureIoTClient | 4:e472f5ce3473 | 212 | if (msgTopic == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 213 | { |
AzureIoTClient | 4:e472f5ce3473 | 214 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 215 | } |
AzureIoTClient | 4:e472f5ce3473 | 216 | else |
AzureIoTClient | 4:e472f5ce3473 | 217 | { |
AzureIoTClient | 6:16875b609849 | 218 | MQTT_MESSAGE_HANDLE mqttMsg = mqttmessage_create(mqttMsgEntry->msgPacketId, STRING_c_str(msgTopic), DELIVER_AT_LEAST_ONCE, payload, len); |
AzureIoTClient | 4:e472f5ce3473 | 219 | if (mqttMsg == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 220 | { |
AzureIoTClient | 4:e472f5ce3473 | 221 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 222 | } |
AzureIoTClient | 4:e472f5ce3473 | 223 | else |
AzureIoTClient | 4:e472f5ce3473 | 224 | { |
AzureIoTClient | 4:e472f5ce3473 | 225 | if (mqtt_client_publish(transportState->mqttClient, mqttMsg) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 226 | { |
AzureIoTClient | 4:e472f5ce3473 | 227 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 228 | } |
AzureIoTClient | 4:e472f5ce3473 | 229 | else |
AzureIoTClient | 4:e472f5ce3473 | 230 | { |
AzureIoTClient | 4:e472f5ce3473 | 231 | mqttMsgEntry->retryCount++; |
AzureIoTClient | 4:e472f5ce3473 | 232 | (void)tickcounter_get_current_ms(g_msgTickCounter, &mqttMsgEntry->msgPublishTime); |
AzureIoTClient | 4:e472f5ce3473 | 233 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 234 | } |
AzureIoTClient | 4:e472f5ce3473 | 235 | mqttmessage_destroy(mqttMsg); |
AzureIoTClient | 4:e472f5ce3473 | 236 | } |
AzureIoTClient | 4:e472f5ce3473 | 237 | STRING_delete(msgTopic); |
AzureIoTClient | 4:e472f5ce3473 | 238 | } |
AzureIoTClient | 4:e472f5ce3473 | 239 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 240 | } |
AzureIoTClient | 3:40f482ed0be8 | 241 | |
AzureIoTClient | 3:40f482ed0be8 | 242 | static bool isSystemProperty(const char* tokenData) |
AzureIoTClient | 3:40f482ed0be8 | 243 | { |
AzureIoTClient | 4:e472f5ce3473 | 244 | bool result = false; |
AzureIoTClient | 4:e472f5ce3473 | 245 | size_t propCount = sizeof(sysPropList)/sizeof(sysPropList[0]); |
AzureIoTClient | 4:e472f5ce3473 | 246 | for (size_t index = 0; index < propCount; index++) |
AzureIoTClient | 4:e472f5ce3473 | 247 | { |
AzureIoTClient | 4:e472f5ce3473 | 248 | if (memcmp(tokenData, sysPropList[index].propName, sysPropList[index].propLength) == 0) |
AzureIoTClient | 4:e472f5ce3473 | 249 | { |
AzureIoTClient | 4:e472f5ce3473 | 250 | result = true; |
AzureIoTClient | 4:e472f5ce3473 | 251 | break; |
AzureIoTClient | 4:e472f5ce3473 | 252 | } |
AzureIoTClient | 4:e472f5ce3473 | 253 | } |
AzureIoTClient | 4:e472f5ce3473 | 254 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 255 | } |
AzureIoTClient | 3:40f482ed0be8 | 256 | |
AzureIoTClient | 3:40f482ed0be8 | 257 | static int extractMqttProperties(IOTHUB_MESSAGE_HANDLE IoTHubMessage, MQTT_MESSAGE_HANDLE msgHandle) |
AzureIoTClient | 3:40f482ed0be8 | 258 | { |
AzureIoTClient | 4:e472f5ce3473 | 259 | int result; |
AzureIoTClient | 4:e472f5ce3473 | 260 | STRING_HANDLE mqttTopic = STRING_construct(mqttmessage_getTopicName(msgHandle)); |
AzureIoTClient | 3:40f482ed0be8 | 261 | |
AzureIoTClient | 4:e472f5ce3473 | 262 | STRING_TOKENIZER_HANDLE token = STRING_TOKENIZER_create(mqttTopic); |
AzureIoTClient | 4:e472f5ce3473 | 263 | if (token != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 264 | { |
AzureIoTClient | 4:e472f5ce3473 | 265 | MAP_HANDLE propertyMap = IoTHubMessage_Properties(IoTHubMessage); |
AzureIoTClient | 4:e472f5ce3473 | 266 | if (propertyMap == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 267 | { |
AzureIoTClient | 4:e472f5ce3473 | 268 | LogError("Failure to retrieve IoTHubMessage_properties."); |
AzureIoTClient | 4:e472f5ce3473 | 269 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 270 | } |
AzureIoTClient | 4:e472f5ce3473 | 271 | else |
AzureIoTClient | 4:e472f5ce3473 | 272 | { |
AzureIoTClient | 4:e472f5ce3473 | 273 | STRING_HANDLE output = STRING_new(); |
AzureIoTClient | 4:e472f5ce3473 | 274 | if (output == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 275 | { |
AzureIoTClient | 4:e472f5ce3473 | 276 | LogError("Failure to allocate STRING_new."); |
AzureIoTClient | 4:e472f5ce3473 | 277 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 278 | } |
AzureIoTClient | 4:e472f5ce3473 | 279 | else |
AzureIoTClient | 4:e472f5ce3473 | 280 | { |
AzureIoTClient | 4:e472f5ce3473 | 281 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 282 | while (STRING_TOKENIZER_get_next_token(token, output, PROPERTY_SEPARATOR) == 0 && result == 0) |
AzureIoTClient | 4:e472f5ce3473 | 283 | { |
AzureIoTClient | 4:e472f5ce3473 | 284 | const char* tokenData = STRING_c_str(output); |
AzureIoTClient | 4:e472f5ce3473 | 285 | size_t tokenLen = strlen(tokenData); |
AzureIoTClient | 4:e472f5ce3473 | 286 | if (tokenData == NULL || tokenLen == 0) |
AzureIoTClient | 4:e472f5ce3473 | 287 | { |
AzureIoTClient | 4:e472f5ce3473 | 288 | break; |
AzureIoTClient | 4:e472f5ce3473 | 289 | } |
AzureIoTClient | 4:e472f5ce3473 | 290 | else |
AzureIoTClient | 4:e472f5ce3473 | 291 | { |
AzureIoTClient | 4:e472f5ce3473 | 292 | if (!isSystemProperty(tokenData) ) |
AzureIoTClient | 4:e472f5ce3473 | 293 | { |
AzureIoTClient | 4:e472f5ce3473 | 294 | const char* iterator = tokenData; |
AzureIoTClient | 4:e472f5ce3473 | 295 | while (iterator != NULL && *iterator != '\0' && result == 0) |
AzureIoTClient | 4:e472f5ce3473 | 296 | { |
AzureIoTClient | 4:e472f5ce3473 | 297 | if (*iterator == '=') |
AzureIoTClient | 4:e472f5ce3473 | 298 | { |
AzureIoTClient | 4:e472f5ce3473 | 299 | size_t nameLen = iterator - tokenData; |
AzureIoTClient | 4:e472f5ce3473 | 300 | char* propName = malloc(nameLen + 1); |
AzureIoTClient | 3:40f482ed0be8 | 301 | |
AzureIoTClient | 4:e472f5ce3473 | 302 | size_t valLen = tokenLen - (nameLen + 1) + 1; |
AzureIoTClient | 4:e472f5ce3473 | 303 | char* propValue = malloc(valLen + 1); |
AzureIoTClient | 3:40f482ed0be8 | 304 | |
AzureIoTClient | 4:e472f5ce3473 | 305 | if (propName == NULL || propValue == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 306 | { |
AzureIoTClient | 4:e472f5ce3473 | 307 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 308 | } |
AzureIoTClient | 4:e472f5ce3473 | 309 | else |
AzureIoTClient | 4:e472f5ce3473 | 310 | { |
AzureIoTClient | 4:e472f5ce3473 | 311 | strncpy(propName, tokenData, nameLen); |
AzureIoTClient | 4:e472f5ce3473 | 312 | propName[nameLen] = '\0'; |
AzureIoTClient | 3:40f482ed0be8 | 313 | |
AzureIoTClient | 4:e472f5ce3473 | 314 | strncpy(propValue, iterator + 1, valLen); |
AzureIoTClient | 4:e472f5ce3473 | 315 | propValue[valLen] = '\0'; |
AzureIoTClient | 3:40f482ed0be8 | 316 | |
AzureIoTClient | 4:e472f5ce3473 | 317 | if (Map_AddOrUpdate(propertyMap, propName, propValue) != MAP_OK) |
AzureIoTClient | 4:e472f5ce3473 | 318 | { |
AzureIoTClient | 4:e472f5ce3473 | 319 | LogError("Map_AddOrUpdate failed."); |
AzureIoTClient | 4:e472f5ce3473 | 320 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 321 | } |
AzureIoTClient | 4:e472f5ce3473 | 322 | } |
AzureIoTClient | 4:e472f5ce3473 | 323 | free(propName); |
AzureIoTClient | 4:e472f5ce3473 | 324 | free(propValue); |
AzureIoTClient | 3:40f482ed0be8 | 325 | |
AzureIoTClient | 4:e472f5ce3473 | 326 | break; |
AzureIoTClient | 4:e472f5ce3473 | 327 | } |
AzureIoTClient | 4:e472f5ce3473 | 328 | iterator++; |
AzureIoTClient | 4:e472f5ce3473 | 329 | } |
AzureIoTClient | 4:e472f5ce3473 | 330 | } |
AzureIoTClient | 4:e472f5ce3473 | 331 | } |
AzureIoTClient | 4:e472f5ce3473 | 332 | } |
AzureIoTClient | 4:e472f5ce3473 | 333 | STRING_delete(output); |
AzureIoTClient | 4:e472f5ce3473 | 334 | } |
AzureIoTClient | 4:e472f5ce3473 | 335 | } |
AzureIoTClient | 4:e472f5ce3473 | 336 | STRING_TOKENIZER_destroy(token); |
AzureIoTClient | 4:e472f5ce3473 | 337 | } |
AzureIoTClient | 4:e472f5ce3473 | 338 | else |
AzureIoTClient | 4:e472f5ce3473 | 339 | { |
AzureIoTClient | 4:e472f5ce3473 | 340 | LogError("Unable to create Tokenizer object."); |
AzureIoTClient | 4:e472f5ce3473 | 341 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 342 | } |
AzureIoTClient | 4:e472f5ce3473 | 343 | STRING_delete(mqttTopic); |
AzureIoTClient | 3:40f482ed0be8 | 344 | |
AzureIoTClient | 4:e472f5ce3473 | 345 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 346 | } |
AzureIoTClient | 3:40f482ed0be8 | 347 | |
AzureIoTClient | 3:40f482ed0be8 | 348 | static void MqttRecvCallback(MQTT_MESSAGE_HANDLE msgHandle, void* callbackCtx) |
AzureIoTClient | 3:40f482ed0be8 | 349 | { |
AzureIoTClient | 4:e472f5ce3473 | 350 | if (msgHandle != NULL && callbackCtx != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 351 | { |
AzureIoTClient | 4:e472f5ce3473 | 352 | const APP_PAYLOAD* appPayload = mqttmessage_getApplicationMsg(msgHandle); |
AzureIoTClient | 4:e472f5ce3473 | 353 | IOTHUB_MESSAGE_HANDLE IoTHubMessage = IoTHubMessage_CreateFromByteArray(appPayload->message, appPayload->length); |
AzureIoTClient | 4:e472f5ce3473 | 354 | if (IoTHubMessage == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 355 | { |
AzureIoTClient | 4:e472f5ce3473 | 356 | LogError("IotHub Message creation has failed."); |
AzureIoTClient | 4:e472f5ce3473 | 357 | } |
AzureIoTClient | 4:e472f5ce3473 | 358 | else |
AzureIoTClient | 4:e472f5ce3473 | 359 | { |
AzureIoTClient | 4:e472f5ce3473 | 360 | // Will need to update this when the service has messages that can be rejected |
AzureIoTClient | 4:e472f5ce3473 | 361 | (void)extractMqttProperties(IoTHubMessage, msgHandle); |
AzureIoTClient | 4:e472f5ce3473 | 362 | PMQTTTRANSPORT_HANDLE_DATA transportData = (PMQTTTRANSPORT_HANDLE_DATA)callbackCtx; |
AzureIoTClient | 4:e472f5ce3473 | 363 | if (IoTHubClient_LL_MessageCallback(transportData->llClientHandle, IoTHubMessage) != IOTHUBMESSAGE_ACCEPTED) |
AzureIoTClient | 4:e472f5ce3473 | 364 | { |
AzureIoTClient | 4:e472f5ce3473 | 365 | LogError("Event not accepted by our client."); |
AzureIoTClient | 4:e472f5ce3473 | 366 | } |
AzureIoTClient | 4:e472f5ce3473 | 367 | IoTHubMessage_Destroy(IoTHubMessage); |
AzureIoTClient | 4:e472f5ce3473 | 368 | } |
AzureIoTClient | 4:e472f5ce3473 | 369 | } |
AzureIoTClient | 3:40f482ed0be8 | 370 | } |
AzureIoTClient | 3:40f482ed0be8 | 371 | |
AzureIoTClient | 3:40f482ed0be8 | 372 | static void MqttOpCompleteCallback(MQTT_CLIENT_HANDLE handle, MQTT_CLIENT_EVENT_RESULT actionResult, const void* msgInfo, void* callbackCtx) |
AzureIoTClient | 3:40f482ed0be8 | 373 | { |
AzureIoTClient | 4:e472f5ce3473 | 374 | (void)handle; |
AzureIoTClient | 4:e472f5ce3473 | 375 | if (callbackCtx != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 376 | { |
AzureIoTClient | 4:e472f5ce3473 | 377 | PMQTTTRANSPORT_HANDLE_DATA transportData = (PMQTTTRANSPORT_HANDLE_DATA)callbackCtx; |
AzureIoTClient | 3:40f482ed0be8 | 378 | |
AzureIoTClient | 4:e472f5ce3473 | 379 | switch (actionResult) |
AzureIoTClient | 4:e472f5ce3473 | 380 | { |
AzureIoTClient | 4:e472f5ce3473 | 381 | case MQTT_CLIENT_ON_PUBLISH_ACK: |
AzureIoTClient | 4:e472f5ce3473 | 382 | case MQTT_CLIENT_ON_PUBLISH_COMP: |
AzureIoTClient | 4:e472f5ce3473 | 383 | { |
AzureIoTClient | 4:e472f5ce3473 | 384 | const PUBLISH_ACK* puback = (const PUBLISH_ACK*)msgInfo; |
AzureIoTClient | 4:e472f5ce3473 | 385 | if (puback != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 386 | { |
AzureIoTClient | 4:e472f5ce3473 | 387 | PDLIST_ENTRY currentListEntry = transportData->waitingForAck.Flink; |
AzureIoTClient | 4:e472f5ce3473 | 388 | while (currentListEntry != &transportData->waitingForAck) |
AzureIoTClient | 4:e472f5ce3473 | 389 | { |
AzureIoTClient | 4:e472f5ce3473 | 390 | MQTT_MESSAGE_DETAILS_LIST* mqttMsgEntry = containingRecord(currentListEntry, MQTT_MESSAGE_DETAILS_LIST, entry); |
AzureIoTClient | 4:e472f5ce3473 | 391 | DLIST_ENTRY saveListEntry; |
AzureIoTClient | 4:e472f5ce3473 | 392 | saveListEntry.Flink = currentListEntry->Flink; |
AzureIoTClient | 3:40f482ed0be8 | 393 | |
AzureIoTClient | 4:e472f5ce3473 | 394 | if (puback->packetId == mqttMsgEntry->msgPacketId) |
AzureIoTClient | 4:e472f5ce3473 | 395 | { |
AzureIoTClient | 4:e472f5ce3473 | 396 | (void)DList_RemoveEntryList(currentListEntry); //First remove the item from Waiting for Ack List. |
Azure.IoT Build | 5:73603e7a6542 | 397 | sendMsgComplete(mqttMsgEntry->iotHubMessageEntry, transportData, IOTHUB_CLIENT_CONFIRMATION_OK); |
AzureIoTClient | 4:e472f5ce3473 | 398 | free(mqttMsgEntry); |
AzureIoTClient | 4:e472f5ce3473 | 399 | } |
AzureIoTClient | 4:e472f5ce3473 | 400 | currentListEntry = saveListEntry.Flink; |
AzureIoTClient | 4:e472f5ce3473 | 401 | } |
AzureIoTClient | 4:e472f5ce3473 | 402 | } |
AzureIoTClient | 4:e472f5ce3473 | 403 | break; |
AzureIoTClient | 4:e472f5ce3473 | 404 | } |
AzureIoTClient | 4:e472f5ce3473 | 405 | case MQTT_CLIENT_ON_CONNACK: |
AzureIoTClient | 4:e472f5ce3473 | 406 | { |
AzureIoTClient | 4:e472f5ce3473 | 407 | const CONNECT_ACK* connack = (const CONNECT_ACK*)msgInfo; |
AzureIoTClient | 4:e472f5ce3473 | 408 | if (connack != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 409 | { |
AzureIoTClient | 4:e472f5ce3473 | 410 | if (connack->returnCode == CONNECTION_ACCEPTED) |
AzureIoTClient | 4:e472f5ce3473 | 411 | { |
AzureIoTClient | 4:e472f5ce3473 | 412 | // The connect packet has been acked |
AzureIoTClient | 4:e472f5ce3473 | 413 | transportData->currPacketState = CONNACK_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 414 | } |
AzureIoTClient | 4:e472f5ce3473 | 415 | else |
AzureIoTClient | 4:e472f5ce3473 | 416 | { |
AzureIoTClient | 4:e472f5ce3473 | 417 | LogError("Connection not accepted, return code: %d.", connack->returnCode); |
AzureIoTClient | 4:e472f5ce3473 | 418 | (void)mqtt_client_disconnect(transportData->mqttClient); |
AzureIoTClient | 4:e472f5ce3473 | 419 | transportData->connected = false; |
AzureIoTClient | 4:e472f5ce3473 | 420 | transportData->currPacketState = PACKET_TYPE_ERROR; |
AzureIoTClient | 4:e472f5ce3473 | 421 | } |
AzureIoTClient | 4:e472f5ce3473 | 422 | } |
AzureIoTClient | 4:e472f5ce3473 | 423 | else |
AzureIoTClient | 4:e472f5ce3473 | 424 | { |
AzureIoTClient | 4:e472f5ce3473 | 425 | LogError("MQTT_CLIENT_ON_CONNACK CONNACK parameter is NULL."); |
AzureIoTClient | 4:e472f5ce3473 | 426 | } |
AzureIoTClient | 4:e472f5ce3473 | 427 | break; |
AzureIoTClient | 4:e472f5ce3473 | 428 | } |
AzureIoTClient | 4:e472f5ce3473 | 429 | case MQTT_CLIENT_ON_SUBSCRIBE_ACK: |
AzureIoTClient | 4:e472f5ce3473 | 430 | { |
AzureIoTClient | 4:e472f5ce3473 | 431 | const SUBSCRIBE_ACK* suback = (const SUBSCRIBE_ACK*)msgInfo; |
AzureIoTClient | 4:e472f5ce3473 | 432 | if (suback != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 433 | { |
AzureIoTClient | 4:e472f5ce3473 | 434 | if (suback->qosCount == 1) |
AzureIoTClient | 4:e472f5ce3473 | 435 | { |
AzureIoTClient | 4:e472f5ce3473 | 436 | // The connect packet has been acked |
AzureIoTClient | 4:e472f5ce3473 | 437 | transportData->currPacketState = SUBACK_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 438 | } |
AzureIoTClient | 4:e472f5ce3473 | 439 | else |
AzureIoTClient | 4:e472f5ce3473 | 440 | { |
AzureIoTClient | 4:e472f5ce3473 | 441 | LogError("QOS count was not expected: %d.", (int)suback->qosCount); |
AzureIoTClient | 4:e472f5ce3473 | 442 | } |
AzureIoTClient | 4:e472f5ce3473 | 443 | } |
AzureIoTClient | 4:e472f5ce3473 | 444 | break; |
AzureIoTClient | 4:e472f5ce3473 | 445 | } |
AzureIoTClient | 4:e472f5ce3473 | 446 | case MQTT_CLIENT_ON_PUBLISH_RECV: |
AzureIoTClient | 4:e472f5ce3473 | 447 | case MQTT_CLIENT_ON_PUBLISH_REL: |
AzureIoTClient | 4:e472f5ce3473 | 448 | { |
AzureIoTClient | 4:e472f5ce3473 | 449 | // Currently not used |
AzureIoTClient | 4:e472f5ce3473 | 450 | break; |
AzureIoTClient | 4:e472f5ce3473 | 451 | } |
AzureIoTClient | 4:e472f5ce3473 | 452 | case MQTT_CLIENT_ON_DISCONNECT: |
AzureIoTClient | 4:e472f5ce3473 | 453 | { |
AzureIoTClient | 4:e472f5ce3473 | 454 | // Close the client so we can reconnect again |
AzureIoTClient | 4:e472f5ce3473 | 455 | transportData->connected = false; |
AzureIoTClient | 4:e472f5ce3473 | 456 | transportData->currPacketState = DISCONNECT_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 457 | break; |
AzureIoTClient | 4:e472f5ce3473 | 458 | } |
AzureIoTClient | 4:e472f5ce3473 | 459 | case MQTT_CLIENT_NO_PING_RESPONSE: |
AzureIoTClient | 4:e472f5ce3473 | 460 | LogError("Mqtt Ping Response was not encountered. Reconnecting device..."); |
AzureIoTClient | 4:e472f5ce3473 | 461 | case MQTT_CLIENT_ON_ERROR: |
AzureIoTClient | 4:e472f5ce3473 | 462 | { |
AzureIoTClient | 4:e472f5ce3473 | 463 | xio_close(transportData->xioTransport, NULL, NULL); |
AzureIoTClient | 4:e472f5ce3473 | 464 | transportData->connected = false; |
AzureIoTClient | 4:e472f5ce3473 | 465 | transportData->subscribed = false; |
AzureIoTClient | 4:e472f5ce3473 | 466 | transportData->currPacketState = PACKET_TYPE_ERROR; |
AzureIoTClient | 4:e472f5ce3473 | 467 | } |
AzureIoTClient | 4:e472f5ce3473 | 468 | } |
AzureIoTClient | 4:e472f5ce3473 | 469 | } |
AzureIoTClient | 3:40f482ed0be8 | 470 | } |
AzureIoTClient | 3:40f482ed0be8 | 471 | |
AzureIoTClient | 3:40f482ed0be8 | 472 | const XIO_HANDLE getIoTransportProvider(const char* fqdn, int port) |
AzureIoTClient | 3:40f482ed0be8 | 473 | { |
AzureIoTClient | 6:16875b609849 | 474 | TLSIO_CONFIG tls_io_config; |
AzureIoTClient | 4:e472f5ce3473 | 475 | const IO_INTERFACE_DESCRIPTION* io_interface_description = platform_get_default_tlsio(); |
AzureIoTClient | 6:16875b609849 | 476 | tls_io_config.hostname = fqdn; |
AzureIoTClient | 6:16875b609849 | 477 | tls_io_config.port = port; |
AzureIoTClient | 6:16875b609849 | 478 | return xio_create(io_interface_description, &tls_io_config); |
AzureIoTClient | 3:40f482ed0be8 | 479 | } |
AzureIoTClient | 3:40f482ed0be8 | 480 | |
AzureIoTClient | 3:40f482ed0be8 | 481 | static int SubscribeToMqttProtocol(PMQTTTRANSPORT_HANDLE_DATA transportState) |
AzureIoTClient | 3:40f482ed0be8 | 482 | { |
AzureIoTClient | 4:e472f5ce3473 | 483 | int result; |
AzureIoTClient | 3:40f482ed0be8 | 484 | |
AzureIoTClient | 4:e472f5ce3473 | 485 | if (transportState->receiveMessages && !transportState->subscribed) |
AzureIoTClient | 4:e472f5ce3473 | 486 | { |
AzureIoTClient | 6:16875b609849 | 487 | SUBSCRIBE_PAYLOAD subscribe[1]; |
AzureIoTClient | 6:16875b609849 | 488 | |
AzureIoTClient | 6:16875b609849 | 489 | subscribe[0].subscribeTopic = STRING_c_str(transportState->mqttMessageTopic); |
AzureIoTClient | 6:16875b609849 | 490 | subscribe[0].qosReturn = DELIVER_AT_LEAST_ONCE; |
AzureIoTClient | 6:16875b609849 | 491 | |
AzureIoTClient | 4:e472f5ce3473 | 492 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_016: [IoTHubTransportMqtt_Subscribe shall call mqtt_client_subscribe to subscribe to the Message Topic.] */ |
AzureIoTClient | 6:16875b609849 | 493 | if (mqtt_client_subscribe(transportState->mqttClient, get_next_packet_id(transportState), subscribe, 1) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 494 | { |
AzureIoTClient | 4:e472f5ce3473 | 495 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_017: [Upon failure IoTHubTransportMqtt_Subscribe shall return a non-zero value.] */ |
AzureIoTClient | 4:e472f5ce3473 | 496 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 497 | } |
AzureIoTClient | 4:e472f5ce3473 | 498 | else |
AzureIoTClient | 4:e472f5ce3473 | 499 | { |
AzureIoTClient | 4:e472f5ce3473 | 500 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_018: [On success IoTHubTransportMqtt_Subscribe shall return 0.] */ |
AzureIoTClient | 4:e472f5ce3473 | 501 | transportState->subscribed = true; |
AzureIoTClient | 4:e472f5ce3473 | 502 | transportState->currPacketState = SUBSCRIBE_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 503 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 504 | } |
AzureIoTClient | 4:e472f5ce3473 | 505 | } |
AzureIoTClient | 4:e472f5ce3473 | 506 | else |
AzureIoTClient | 4:e472f5ce3473 | 507 | { |
AzureIoTClient | 4:e472f5ce3473 | 508 | if (transportState->receiveMessages) |
AzureIoTClient | 4:e472f5ce3473 | 509 | { |
AzureIoTClient | 4:e472f5ce3473 | 510 | transportState->currPacketState = SUBSCRIBE_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 511 | } |
AzureIoTClient | 4:e472f5ce3473 | 512 | else |
AzureIoTClient | 4:e472f5ce3473 | 513 | { |
AzureIoTClient | 4:e472f5ce3473 | 514 | transportState->currPacketState = PUBLISH_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 515 | } |
AzureIoTClient | 6:16875b609849 | 516 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 517 | } |
AzureIoTClient | 4:e472f5ce3473 | 518 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 519 | } |
AzureIoTClient | 3:40f482ed0be8 | 520 | |
AzureIoTClient | 3:40f482ed0be8 | 521 | static const unsigned char* RetrieveMessagePayload(IOTHUB_MESSAGE_HANDLE messageHandle, size_t* length) |
AzureIoTClient | 3:40f482ed0be8 | 522 | { |
AzureIoTClient | 4:e472f5ce3473 | 523 | const unsigned char* result; |
AzureIoTClient | 3:40f482ed0be8 | 524 | |
AzureIoTClient | 4:e472f5ce3473 | 525 | IOTHUBMESSAGE_CONTENT_TYPE contentType = IoTHubMessage_GetContentType(messageHandle); |
AzureIoTClient | 4:e472f5ce3473 | 526 | if (contentType == IOTHUBMESSAGE_BYTEARRAY) |
AzureIoTClient | 4:e472f5ce3473 | 527 | { |
AzureIoTClient | 4:e472f5ce3473 | 528 | if (IoTHubMessage_GetByteArray(messageHandle, &result, length) != IOTHUB_MESSAGE_OK) |
AzureIoTClient | 4:e472f5ce3473 | 529 | { |
AzureIoTClient | 4:e472f5ce3473 | 530 | LogError("Failure result from IoTHubMessage_GetByteArray"); |
AzureIoTClient | 4:e472f5ce3473 | 531 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 532 | *length = 0; |
AzureIoTClient | 4:e472f5ce3473 | 533 | } |
AzureIoTClient | 4:e472f5ce3473 | 534 | } |
AzureIoTClient | 4:e472f5ce3473 | 535 | else if (contentType == IOTHUBMESSAGE_STRING) |
AzureIoTClient | 4:e472f5ce3473 | 536 | { |
AzureIoTClient | 4:e472f5ce3473 | 537 | result = (const unsigned char*)IoTHubMessage_GetString(messageHandle); |
AzureIoTClient | 4:e472f5ce3473 | 538 | if (result == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 539 | { |
AzureIoTClient | 4:e472f5ce3473 | 540 | LogError("Failure result from IoTHubMessage_GetString"); |
AzureIoTClient | 4:e472f5ce3473 | 541 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 542 | *length = 0; |
AzureIoTClient | 4:e472f5ce3473 | 543 | } |
AzureIoTClient | 4:e472f5ce3473 | 544 | else |
AzureIoTClient | 4:e472f5ce3473 | 545 | { |
AzureIoTClient | 4:e472f5ce3473 | 546 | *length = strlen((const char*)result); |
AzureIoTClient | 4:e472f5ce3473 | 547 | } |
AzureIoTClient | 4:e472f5ce3473 | 548 | } |
AzureIoTClient | 4:e472f5ce3473 | 549 | else |
AzureIoTClient | 4:e472f5ce3473 | 550 | { |
AzureIoTClient | 4:e472f5ce3473 | 551 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 552 | *length = 0; |
AzureIoTClient | 4:e472f5ce3473 | 553 | } |
AzureIoTClient | 4:e472f5ce3473 | 554 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 555 | } |
AzureIoTClient | 3:40f482ed0be8 | 556 | |
AzureIoTClient | 3:40f482ed0be8 | 557 | static STRING_HANDLE ConstructSasToken(const char* iothubName, const char* iotHubSuffix, const char* deviceId) |
AzureIoTClient | 3:40f482ed0be8 | 558 | { |
AzureIoTClient | 4:e472f5ce3473 | 559 | STRING_HANDLE result; |
AzureIoTClient | 4:e472f5ce3473 | 560 | size_t len = strlen(iothubName); |
AzureIoTClient | 4:e472f5ce3473 | 561 | len += strlen(iotHubSuffix); |
AzureIoTClient | 4:e472f5ce3473 | 562 | len += strlen(deviceId); |
AzureIoTClient | 3:40f482ed0be8 | 563 | |
AzureIoTClient | 4:e472f5ce3473 | 564 | char* sasToken = malloc(len + SAS_TOKEN_DEFAULT_LEN + 1); |
AzureIoTClient | 4:e472f5ce3473 | 565 | if (sasToken == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 566 | { |
AzureIoTClient | 4:e472f5ce3473 | 567 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 568 | } |
AzureIoTClient | 4:e472f5ce3473 | 569 | else |
AzureIoTClient | 4:e472f5ce3473 | 570 | { |
AzureIoTClient | 4:e472f5ce3473 | 571 | (void)sprintf(sasToken, "%s.%s/devices/%s", iothubName, iotHubSuffix, deviceId); |
AzureIoTClient | 4:e472f5ce3473 | 572 | result = STRING_construct(sasToken); |
AzureIoTClient | 4:e472f5ce3473 | 573 | free(sasToken); |
AzureIoTClient | 4:e472f5ce3473 | 574 | } |
AzureIoTClient | 4:e472f5ce3473 | 575 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 576 | } |
AzureIoTClient | 3:40f482ed0be8 | 577 | |
AzureIoTClient | 3:40f482ed0be8 | 578 | static STRING_HANDLE ConstructEventTopic(const char* deviceId) |
AzureIoTClient | 3:40f482ed0be8 | 579 | { |
AzureIoTClient | 4:e472f5ce3473 | 580 | STRING_HANDLE result; |
AzureIoTClient | 4:e472f5ce3473 | 581 | size_t len = strlen(deviceId); |
AzureIoTClient | 3:40f482ed0be8 | 582 | |
AzureIoTClient | 4:e472f5ce3473 | 583 | char* eventTopic = malloc(len + EVENT_TOPIC_DEFAULT_LEN + 1); |
AzureIoTClient | 4:e472f5ce3473 | 584 | if (eventTopic == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 585 | { |
AzureIoTClient | 4:e472f5ce3473 | 586 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 587 | } |
AzureIoTClient | 4:e472f5ce3473 | 588 | else |
AzureIoTClient | 4:e472f5ce3473 | 589 | { |
AzureIoTClient | 4:e472f5ce3473 | 590 | (void)sprintf(eventTopic, DEVICE_DEVICE_TOPIC, deviceId); |
AzureIoTClient | 4:e472f5ce3473 | 591 | result = STRING_construct(eventTopic); |
AzureIoTClient | 4:e472f5ce3473 | 592 | free(eventTopic); |
AzureIoTClient | 4:e472f5ce3473 | 593 | } |
AzureIoTClient | 4:e472f5ce3473 | 594 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 595 | } |
AzureIoTClient | 3:40f482ed0be8 | 596 | |
AzureIoTClient | 3:40f482ed0be8 | 597 | static STRING_HANDLE ConstructMessageTopic(const char* deviceId) |
AzureIoTClient | 3:40f482ed0be8 | 598 | { |
AzureIoTClient | 4:e472f5ce3473 | 599 | STRING_HANDLE result; |
AzureIoTClient | 4:e472f5ce3473 | 600 | size_t len = strlen(deviceId); |
AzureIoTClient | 3:40f482ed0be8 | 601 | |
AzureIoTClient | 4:e472f5ce3473 | 602 | char* messageTopic = malloc(len + 32 + 1); |
AzureIoTClient | 4:e472f5ce3473 | 603 | if (messageTopic == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 604 | { |
AzureIoTClient | 4:e472f5ce3473 | 605 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 606 | } |
AzureIoTClient | 4:e472f5ce3473 | 607 | else |
AzureIoTClient | 4:e472f5ce3473 | 608 | { |
AzureIoTClient | 4:e472f5ce3473 | 609 | (void)sprintf(messageTopic, DEVICE_MSG_TOPIC, deviceId); |
AzureIoTClient | 4:e472f5ce3473 | 610 | result = STRING_construct(messageTopic); |
AzureIoTClient | 4:e472f5ce3473 | 611 | free(messageTopic); |
AzureIoTClient | 4:e472f5ce3473 | 612 | } |
AzureIoTClient | 4:e472f5ce3473 | 613 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 614 | } |
AzureIoTClient | 3:40f482ed0be8 | 615 | |
AzureIoTClient | 3:40f482ed0be8 | 616 | static int GetTransportProviderIfNecessary(PMQTTTRANSPORT_HANDLE_DATA transportState) |
AzureIoTClient | 3:40f482ed0be8 | 617 | { |
AzureIoTClient | 4:e472f5ce3473 | 618 | int result; |
AzureIoTClient | 3:40f482ed0be8 | 619 | |
AzureIoTClient | 4:e472f5ce3473 | 620 | if (transportState->xioTransport == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 621 | { |
AzureIoTClient | 4:e472f5ce3473 | 622 | // construct address |
AzureIoTClient | 4:e472f5ce3473 | 623 | const char* hostAddress = STRING_c_str(transportState->hostAddress); |
AzureIoTClient | 4:e472f5ce3473 | 624 | transportState->xioTransport = getIoTransportProvider(hostAddress, transportState->portNum); |
AzureIoTClient | 4:e472f5ce3473 | 625 | if (transportState->xioTransport == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 626 | { |
AzureIoTClient | 4:e472f5ce3473 | 627 | LogError("Unable to create the lower level TLS layer."); |
AzureIoTClient | 4:e472f5ce3473 | 628 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 629 | } |
AzureIoTClient | 4:e472f5ce3473 | 630 | else |
AzureIoTClient | 4:e472f5ce3473 | 631 | { |
AzureIoTClient | 4:e472f5ce3473 | 632 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 633 | } |
AzureIoTClient | 4:e472f5ce3473 | 634 | } |
AzureIoTClient | 4:e472f5ce3473 | 635 | else |
AzureIoTClient | 4:e472f5ce3473 | 636 | { |
AzureIoTClient | 4:e472f5ce3473 | 637 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 638 | } |
AzureIoTClient | 4:e472f5ce3473 | 639 | return result; |
AzureIoTClient | 3:40f482ed0be8 | 640 | } |
AzureIoTClient | 3:40f482ed0be8 | 641 | |
AzureIoTClient | 3:40f482ed0be8 | 642 | static int SendMqttConnectMsg(PMQTTTRANSPORT_HANDLE_DATA transportState) |
AzureIoTClient | 3:40f482ed0be8 | 643 | { |
AzureIoTClient | 4:e472f5ce3473 | 644 | int result; |
AzureIoTClient | 3:40f482ed0be8 | 645 | |
AzureIoTClient | 4:e472f5ce3473 | 646 | // Not checking the success of this variable, if fail it will fail in the SASToken creation and return false; |
AzureIoTClient | 4:e472f5ce3473 | 647 | STRING_HANDLE emptyKeyName = STRING_new(); |
AzureIoTClient | 3:40f482ed0be8 | 648 | if (emptyKeyName == NULL) |
Azure.IoT Build | 0:5e72a75c31b8 | 649 | { |
Azure.IoT Build | 0:5e72a75c31b8 | 650 | result = __LINE__; |
Azure.IoT Build | 0:5e72a75c31b8 | 651 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 652 | else |
Azure.IoT Build | 0:5e72a75c31b8 | 653 | { |
AzureIoTClient | 3:40f482ed0be8 | 654 | STRING_HANDLE sasToken = NULL; |
AzureIoTClient | 7:7fdd306e6224 | 655 | |
AzureIoTClient | 7:7fdd306e6224 | 656 | switch (transportState->transport_creds.credential_type) |
AzureIoTClient | 3:40f482ed0be8 | 657 | { |
AzureIoTClient | 7:7fdd306e6224 | 658 | case SAS_TOKEN_FROM_USER: |
AzureIoTClient | 7:7fdd306e6224 | 659 | sasToken = STRING_clone(transportState->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 660 | break; |
AzureIoTClient | 7:7fdd306e6224 | 661 | case DEVICE_KEY: |
AzureIoTClient | 7:7fdd306e6224 | 662 | { |
AzureIoTClient | 7:7fdd306e6224 | 663 | // Construct SAS token |
AzureIoTClient | 7:7fdd306e6224 | 664 | size_t secSinceEpoch = (size_t)(difftime(get_time(NULL), EPOCH_TIME_T_VALUE) + 0); |
AzureIoTClient | 7:7fdd306e6224 | 665 | size_t expiryTime = secSinceEpoch + SAS_TOKEN_DEFAULT_LIFETIME; |
AzureIoTClient | 7:7fdd306e6224 | 666 | |
AzureIoTClient | 7:7fdd306e6224 | 667 | sasToken = SASToken_Create(transportState->transport_creds.CREDENTIAL_VALUE.deviceKey, transportState->devicesPath, emptyKeyName, expiryTime); |
AzureIoTClient | 7:7fdd306e6224 | 668 | break; |
AzureIoTClient | 7:7fdd306e6224 | 669 | } |
AzureIoTClient | 7:7fdd306e6224 | 670 | case X509: |
AzureIoTClient | 7:7fdd306e6224 | 671 | default: |
AzureIoTClient | 7:7fdd306e6224 | 672 | // The assumption here is that x509 is in place, if not setup |
AzureIoTClient | 7:7fdd306e6224 | 673 | // correctly the connection will be rejected. |
AzureIoTClient | 7:7fdd306e6224 | 674 | sasToken = NULL; |
AzureIoTClient | 7:7fdd306e6224 | 675 | break; |
AzureIoTClient | 3:40f482ed0be8 | 676 | } |
AzureIoTClient | 3:40f482ed0be8 | 677 | |
AzureIoTClient | 7:7fdd306e6224 | 678 | MQTT_CLIENT_OPTIONS options = { 0 }; |
AzureIoTClient | 7:7fdd306e6224 | 679 | options.clientId = (char*)STRING_c_str(transportState->device_id); |
AzureIoTClient | 7:7fdd306e6224 | 680 | options.willMessage = NULL; |
AzureIoTClient | 7:7fdd306e6224 | 681 | options.username = (char*)STRING_c_str(transportState->configPassedThroughUsername); |
AzureIoTClient | 7:7fdd306e6224 | 682 | if (sasToken != NULL) |
Azure.IoT Build | 0:5e72a75c31b8 | 683 | { |
AzureIoTClient | 7:7fdd306e6224 | 684 | options.password = (char*)STRING_c_str(sasToken); |
AzureIoTClient | 7:7fdd306e6224 | 685 | } |
AzureIoTClient | 7:7fdd306e6224 | 686 | options.keepAliveInterval = transportState->keepAliveValue; |
AzureIoTClient | 7:7fdd306e6224 | 687 | options.useCleanSession = false; |
AzureIoTClient | 7:7fdd306e6224 | 688 | options.qualityOfServiceValue = DELIVER_AT_LEAST_ONCE; |
AzureIoTClient | 7:7fdd306e6224 | 689 | |
AzureIoTClient | 7:7fdd306e6224 | 690 | if (GetTransportProviderIfNecessary(transportState) == 0) |
AzureIoTClient | 7:7fdd306e6224 | 691 | { |
AzureIoTClient | 7:7fdd306e6224 | 692 | if (mqtt_client_connect(transportState->mqttClient, transportState->xioTransport, &options) != 0) |
AzureIoTClient | 7:7fdd306e6224 | 693 | { |
AzureIoTClient | 7:7fdd306e6224 | 694 | LogError("failure connecting to address %s:%d.", STRING_c_str(transportState->hostAddress), transportState->portNum); |
AzureIoTClient | 7:7fdd306e6224 | 695 | result = __LINE__; |
AzureIoTClient | 7:7fdd306e6224 | 696 | } |
AzureIoTClient | 7:7fdd306e6224 | 697 | else |
AzureIoTClient | 7:7fdd306e6224 | 698 | { |
AzureIoTClient | 7:7fdd306e6224 | 699 | (void)tickcounter_get_current_ms(g_msgTickCounter, &transportState->mqtt_connect_time); |
AzureIoTClient | 7:7fdd306e6224 | 700 | result = 0; |
AzureIoTClient | 7:7fdd306e6224 | 701 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 702 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 703 | else |
Azure.IoT Build | 0:5e72a75c31b8 | 704 | { |
AzureIoTClient | 7:7fdd306e6224 | 705 | result = __LINE__; |
Azure.IoT Build | 0:5e72a75c31b8 | 706 | } |
AzureIoTClient | 3:40f482ed0be8 | 707 | STRING_delete(emptyKeyName); |
AzureIoTClient | 3:40f482ed0be8 | 708 | STRING_delete(sasToken); |
AzureIoTClient | 2:9db4da50abaa | 709 | } |
AzureIoTClient | 4:e472f5ce3473 | 710 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 711 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 712 | |
Azure.IoT Build | 0:5e72a75c31b8 | 713 | static int InitializeConnection(PMQTTTRANSPORT_HANDLE_DATA transportState) |
Azure.IoT Build | 0:5e72a75c31b8 | 714 | { |
AzureIoTClient | 4:e472f5ce3473 | 715 | int result = 0; |
AzureIoTClient | 2:9db4da50abaa | 716 | |
AzureIoTClient | 4:e472f5ce3473 | 717 | // Make sure we're not destroying the object |
AzureIoTClient | 4:e472f5ce3473 | 718 | if (!transportState->destroyCalled) |
AzureIoTClient | 4:e472f5ce3473 | 719 | { |
AzureIoTClient | 4:e472f5ce3473 | 720 | // If we are not connected then check to see if we need |
AzureIoTClient | 4:e472f5ce3473 | 721 | // to back off the connecting to the server |
AzureIoTClient | 4:e472f5ce3473 | 722 | if (!transportState->connected) |
AzureIoTClient | 4:e472f5ce3473 | 723 | { |
AzureIoTClient | 4:e472f5ce3473 | 724 | // Default makeConnection as true if something goes wrong we'll make the connection |
AzureIoTClient | 4:e472f5ce3473 | 725 | bool makeConnection = true; |
AzureIoTClient | 4:e472f5ce3473 | 726 | // If we've failed for FAILED_CONN_BACKOFF_VALUE straight times them let's slow down connection |
AzureIoTClient | 4:e472f5ce3473 | 727 | // to the service |
AzureIoTClient | 4:e472f5ce3473 | 728 | if (transportState->connectFailCount > FAILED_CONN_BACKOFF_VALUE) |
AzureIoTClient | 4:e472f5ce3473 | 729 | { |
AzureIoTClient | 4:e472f5ce3473 | 730 | uint64_t currentTick; |
AzureIoTClient | 4:e472f5ce3473 | 731 | if (tickcounter_get_current_ms(g_msgTickCounter, ¤tTick) == 0) |
AzureIoTClient | 4:e472f5ce3473 | 732 | { |
AzureIoTClient | 4:e472f5ce3473 | 733 | if ( ((currentTick - transportState->connectTick)/1000) <= DEFAULT_CONNECTION_INTERVAL) |
AzureIoTClient | 4:e472f5ce3473 | 734 | { |
AzureIoTClient | 4:e472f5ce3473 | 735 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 736 | makeConnection = false; |
AzureIoTClient | 4:e472f5ce3473 | 737 | } |
AzureIoTClient | 4:e472f5ce3473 | 738 | } |
AzureIoTClient | 4:e472f5ce3473 | 739 | } |
AzureIoTClient | 2:9db4da50abaa | 740 | |
AzureIoTClient | 4:e472f5ce3473 | 741 | if (makeConnection) |
AzureIoTClient | 4:e472f5ce3473 | 742 | { |
AzureIoTClient | 4:e472f5ce3473 | 743 | (void)tickcounter_get_current_ms(g_msgTickCounter, &transportState->connectTick); |
AzureIoTClient | 4:e472f5ce3473 | 744 | if (SendMqttConnectMsg(transportState) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 745 | { |
AzureIoTClient | 4:e472f5ce3473 | 746 | transportState->connectFailCount++; |
AzureIoTClient | 4:e472f5ce3473 | 747 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 748 | } |
AzureIoTClient | 4:e472f5ce3473 | 749 | else |
AzureIoTClient | 4:e472f5ce3473 | 750 | { |
AzureIoTClient | 4:e472f5ce3473 | 751 | transportState->connectFailCount = 0; |
AzureIoTClient | 4:e472f5ce3473 | 752 | transportState->connected = true; |
AzureIoTClient | 4:e472f5ce3473 | 753 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 754 | } |
AzureIoTClient | 4:e472f5ce3473 | 755 | } |
AzureIoTClient | 4:e472f5ce3473 | 756 | } |
AzureIoTClient | 2:9db4da50abaa | 757 | |
AzureIoTClient | 4:e472f5ce3473 | 758 | if (transportState->connected) |
AzureIoTClient | 4:e472f5ce3473 | 759 | { |
AzureIoTClient | 4:e472f5ce3473 | 760 | // We are connected and not being closed, so does SAS need to reconnect? |
AzureIoTClient | 4:e472f5ce3473 | 761 | uint64_t current_time; |
AzureIoTClient | 4:e472f5ce3473 | 762 | (void)tickcounter_get_current_ms(g_msgTickCounter, ¤t_time); |
AzureIoTClient | 4:e472f5ce3473 | 763 | if ((current_time - transportState->mqtt_connect_time) / 1000 > (SAS_TOKEN_DEFAULT_LIFETIME*SAS_REFRESH_MULTIPLIER)) |
AzureIoTClient | 4:e472f5ce3473 | 764 | { |
AzureIoTClient | 4:e472f5ce3473 | 765 | (void)mqtt_client_disconnect(transportState->mqttClient); |
AzureIoTClient | 4:e472f5ce3473 | 766 | transportState->subscribed = false; |
AzureIoTClient | 4:e472f5ce3473 | 767 | transportState->connected = false; |
AzureIoTClient | 4:e472f5ce3473 | 768 | transportState->currPacketState = UNKNOWN_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 769 | } |
AzureIoTClient | 4:e472f5ce3473 | 770 | } |
AzureIoTClient | 4:e472f5ce3473 | 771 | } |
AzureIoTClient | 4:e472f5ce3473 | 772 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 773 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 774 | |
Azure.IoT Build | 0:5e72a75c31b8 | 775 | static STRING_HANDLE buildConfigForUsername(const IOTHUB_CLIENT_CONFIG* upperConfig) |
Azure.IoT Build | 0:5e72a75c31b8 | 776 | { |
AzureIoTClient | 4:e472f5ce3473 | 777 | STRING_HANDLE result; |
Azure.IoT Build | 0:5e72a75c31b8 | 778 | |
AzureIoTClient | 4:e472f5ce3473 | 779 | size_t len = strlen(upperConfig->iotHubName)+strlen(upperConfig->iotHubSuffix)+strlen(upperConfig->deviceId)+strlen(CLIENT_DEVICE_TYPE_PREFIX)+strlen(IOTHUB_SDK_VERSION); |
AzureIoTClient | 4:e472f5ce3473 | 780 | char* eventTopic = malloc(len + BUILD_CONFIG_USERNAME + 1); |
AzureIoTClient | 4:e472f5ce3473 | 781 | if (eventTopic == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 782 | { |
AzureIoTClient | 4:e472f5ce3473 | 783 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 784 | } |
AzureIoTClient | 4:e472f5ce3473 | 785 | else |
AzureIoTClient | 4:e472f5ce3473 | 786 | { |
AzureIoTClient | 4:e472f5ce3473 | 787 | (void)sprintf(eventTopic, "%s.%s/%s/DeviceClientType=%s%%2F%s", upperConfig->iotHubName, upperConfig->iotHubSuffix, upperConfig->deviceId, CLIENT_DEVICE_TYPE_PREFIX, IOTHUB_SDK_VERSION); |
AzureIoTClient | 4:e472f5ce3473 | 788 | result = STRING_construct(eventTopic); |
AzureIoTClient | 4:e472f5ce3473 | 789 | free(eventTopic); |
AzureIoTClient | 4:e472f5ce3473 | 790 | } |
AzureIoTClient | 4:e472f5ce3473 | 791 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 792 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 793 | |
AzureIoTClient | 7:7fdd306e6224 | 794 | static int construct_credential_information(const IOTHUB_CLIENT_CONFIG* upperConfig, PMQTTTRANSPORT_HANDLE_DATA transportState) |
AzureIoTClient | 7:7fdd306e6224 | 795 | { |
AzureIoTClient | 7:7fdd306e6224 | 796 | int result; |
AzureIoTClient | 7:7fdd306e6224 | 797 | if (upperConfig->deviceKey != NULL) |
AzureIoTClient | 7:7fdd306e6224 | 798 | { |
AzureIoTClient | 7:7fdd306e6224 | 799 | transportState->transport_creds.CREDENTIAL_VALUE.deviceKey = STRING_construct(upperConfig->deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 800 | if (transportState->transport_creds.CREDENTIAL_VALUE.deviceKey == NULL) |
AzureIoTClient | 7:7fdd306e6224 | 801 | { |
AzureIoTClient | 7:7fdd306e6224 | 802 | LogError("Could not create device key for MQTT"); |
AzureIoTClient | 7:7fdd306e6224 | 803 | result = __LINE__; |
AzureIoTClient | 7:7fdd306e6224 | 804 | } |
AzureIoTClient | 7:7fdd306e6224 | 805 | else if ( (transportState->devicesPath = ConstructSasToken(upperConfig->iotHubName, upperConfig->iotHubSuffix, upperConfig->deviceId)) == NULL) |
AzureIoTClient | 7:7fdd306e6224 | 806 | { |
AzureIoTClient | 7:7fdd306e6224 | 807 | STRING_delete(transportState->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 808 | result = __LINE__; |
AzureIoTClient | 7:7fdd306e6224 | 809 | } |
AzureIoTClient | 7:7fdd306e6224 | 810 | else |
AzureIoTClient | 7:7fdd306e6224 | 811 | { |
AzureIoTClient | 7:7fdd306e6224 | 812 | transportState->transport_creds.credential_type = DEVICE_KEY; |
AzureIoTClient | 7:7fdd306e6224 | 813 | result = 0; |
AzureIoTClient | 7:7fdd306e6224 | 814 | } |
AzureIoTClient | 7:7fdd306e6224 | 815 | } |
AzureIoTClient | 7:7fdd306e6224 | 816 | else if (upperConfig->deviceSasToken != NULL) |
AzureIoTClient | 7:7fdd306e6224 | 817 | { |
AzureIoTClient | 7:7fdd306e6224 | 818 | transportState->transport_creds.CREDENTIAL_VALUE.deviceSasToken = STRING_construct(upperConfig->deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 819 | if (transportState->transport_creds.CREDENTIAL_VALUE.deviceSasToken == NULL) |
AzureIoTClient | 7:7fdd306e6224 | 820 | { |
AzureIoTClient | 7:7fdd306e6224 | 821 | result = __LINE__; |
AzureIoTClient | 7:7fdd306e6224 | 822 | } |
AzureIoTClient | 7:7fdd306e6224 | 823 | else |
AzureIoTClient | 7:7fdd306e6224 | 824 | { |
AzureIoTClient | 7:7fdd306e6224 | 825 | transportState->transport_creds.credential_type = SAS_TOKEN_FROM_USER; |
AzureIoTClient | 7:7fdd306e6224 | 826 | transportState->devicesPath = NULL; |
AzureIoTClient | 7:7fdd306e6224 | 827 | result = 0; |
AzureIoTClient | 7:7fdd306e6224 | 828 | } |
AzureIoTClient | 7:7fdd306e6224 | 829 | } |
AzureIoTClient | 7:7fdd306e6224 | 830 | else |
AzureIoTClient | 7:7fdd306e6224 | 831 | { |
AzureIoTClient | 7:7fdd306e6224 | 832 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_041: [If both deviceKey and deviceSasToken fields are NULL then IoTHubTransportMqtt_Create shall assume a x509 authentication.] */ |
AzureIoTClient | 7:7fdd306e6224 | 833 | transportState->transport_creds.credential_type = X509; |
AzureIoTClient | 7:7fdd306e6224 | 834 | transportState->devicesPath = NULL; |
AzureIoTClient | 7:7fdd306e6224 | 835 | result = 0; |
AzureIoTClient | 7:7fdd306e6224 | 836 | } |
AzureIoTClient | 7:7fdd306e6224 | 837 | return result; |
AzureIoTClient | 7:7fdd306e6224 | 838 | } |
AzureIoTClient | 7:7fdd306e6224 | 839 | |
Azure.IoT Build | 0:5e72a75c31b8 | 840 | static PMQTTTRANSPORT_HANDLE_DATA InitializeTransportHandleData(const IOTHUB_CLIENT_CONFIG* upperConfig, PDLIST_ENTRY waitingToSend) |
Azure.IoT Build | 0:5e72a75c31b8 | 841 | { |
AzureIoTClient | 4:e472f5ce3473 | 842 | PMQTTTRANSPORT_HANDLE_DATA state = (PMQTTTRANSPORT_HANDLE_DATA)malloc(sizeof(MQTTTRANSPORT_HANDLE_DATA)); |
AzureIoTClient | 4:e472f5ce3473 | 843 | if (state == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 844 | { |
AzureIoTClient | 4:e472f5ce3473 | 845 | LogError("Could not create MQTT transport state. Memory allocation failed."); |
AzureIoTClient | 4:e472f5ce3473 | 846 | } |
AzureIoTClient | 4:e472f5ce3473 | 847 | else if ((state->device_id = STRING_construct(upperConfig->deviceId)) == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 848 | { |
AzureIoTClient | 7:7fdd306e6224 | 849 | LogError("failure constructing device_id."); |
AzureIoTClient | 4:e472f5ce3473 | 850 | free(state); |
AzureIoTClient | 4:e472f5ce3473 | 851 | state = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 852 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 853 | else |
Azure.IoT Build | 0:5e72a75c31b8 | 854 | { |
AzureIoTClient | 7:7fdd306e6224 | 855 | if (construct_credential_information(upperConfig, state) != 0) |
AzureIoTClient | 3:40f482ed0be8 | 856 | { |
AzureIoTClient | 3:40f482ed0be8 | 857 | STRING_delete(state->device_id); |
AzureIoTClient | 3:40f482ed0be8 | 858 | free(state); |
AzureIoTClient | 3:40f482ed0be8 | 859 | state = NULL; |
AzureIoTClient | 3:40f482ed0be8 | 860 | } |
AzureIoTClient | 3:40f482ed0be8 | 861 | else if ((state->mqttEventTopic = ConstructEventTopic(upperConfig->deviceId)) == NULL) |
AzureIoTClient | 3:40f482ed0be8 | 862 | { |
AzureIoTClient | 3:40f482ed0be8 | 863 | LogError("Could not create mqttEventTopic for MQTT"); |
AzureIoTClient | 7:7fdd306e6224 | 864 | STRING_delete(state->devicesPath); |
AzureIoTClient | 7:7fdd306e6224 | 865 | if (state->transport_creds.credential_type == DEVICE_KEY) |
AzureIoTClient | 7:7fdd306e6224 | 866 | { |
AzureIoTClient | 7:7fdd306e6224 | 867 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 868 | } |
AzureIoTClient | 7:7fdd306e6224 | 869 | else if (state->transport_creds.credential_type == SAS_TOKEN_FROM_USER) |
AzureIoTClient | 7:7fdd306e6224 | 870 | { |
AzureIoTClient | 7:7fdd306e6224 | 871 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 872 | } |
AzureIoTClient | 3:40f482ed0be8 | 873 | STRING_delete(state->device_id); |
AzureIoTClient | 3:40f482ed0be8 | 874 | free(state); |
AzureIoTClient | 3:40f482ed0be8 | 875 | state = NULL; |
AzureIoTClient | 3:40f482ed0be8 | 876 | } |
AzureIoTClient | 3:40f482ed0be8 | 877 | else if ((state->mqttMessageTopic = ConstructMessageTopic(upperConfig->deviceId)) == NULL) |
AzureIoTClient | 3:40f482ed0be8 | 878 | { |
AzureIoTClient | 3:40f482ed0be8 | 879 | LogError("Could not create mqttMessageTopic for MQTT"); |
AzureIoTClient | 7:7fdd306e6224 | 880 | STRING_delete(state->devicesPath); |
AzureIoTClient | 7:7fdd306e6224 | 881 | if (state->transport_creds.credential_type == DEVICE_KEY) |
AzureIoTClient | 7:7fdd306e6224 | 882 | { |
AzureIoTClient | 7:7fdd306e6224 | 883 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 884 | } |
AzureIoTClient | 7:7fdd306e6224 | 885 | else if (state->transport_creds.credential_type == SAS_TOKEN_FROM_USER) |
AzureIoTClient | 7:7fdd306e6224 | 886 | { |
AzureIoTClient | 7:7fdd306e6224 | 887 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 888 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 889 | STRING_delete(state->mqttEventTopic); |
Azure.IoT Build | 0:5e72a75c31b8 | 890 | STRING_delete(state->device_id); |
Azure.IoT Build | 0:5e72a75c31b8 | 891 | free(state); |
Azure.IoT Build | 0:5e72a75c31b8 | 892 | state = NULL; |
Azure.IoT Build | 0:5e72a75c31b8 | 893 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 894 | else |
Azure.IoT Build | 0:5e72a75c31b8 | 895 | { |
Azure.IoT Build | 5:73603e7a6542 | 896 | state->mqttClient = mqtt_client_init(MqttRecvCallback, MqttOpCompleteCallback, state); |
AzureIoTClient | 3:40f482ed0be8 | 897 | if (state->mqttClient == NULL) |
Azure.IoT Build | 0:5e72a75c31b8 | 898 | { |
AzureIoTClient | 7:7fdd306e6224 | 899 | LogError("failure initializing mqtt client."); |
AzureIoTClient | 7:7fdd306e6224 | 900 | STRING_delete(state->devicesPath); |
AzureIoTClient | 7:7fdd306e6224 | 901 | if (state->transport_creds.credential_type == DEVICE_KEY) |
AzureIoTClient | 7:7fdd306e6224 | 902 | { |
AzureIoTClient | 7:7fdd306e6224 | 903 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 904 | } |
AzureIoTClient | 7:7fdd306e6224 | 905 | else if (state->transport_creds.credential_type == SAS_TOKEN_FROM_USER) |
AzureIoTClient | 7:7fdd306e6224 | 906 | { |
AzureIoTClient | 7:7fdd306e6224 | 907 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 908 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 909 | STRING_delete(state->mqttEventTopic); |
Azure.IoT Build | 0:5e72a75c31b8 | 910 | STRING_delete(state->mqttMessageTopic); |
Azure.IoT Build | 0:5e72a75c31b8 | 911 | STRING_delete(state->device_id); |
Azure.IoT Build | 0:5e72a75c31b8 | 912 | free(state); |
Azure.IoT Build | 0:5e72a75c31b8 | 913 | state = NULL; |
Azure.IoT Build | 0:5e72a75c31b8 | 914 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 915 | else |
Azure.IoT Build | 0:5e72a75c31b8 | 916 | { |
AzureIoTClient | 3:40f482ed0be8 | 917 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_008: [The hostname shall be constructed using the iothubname and iothubSuffix.] */ |
AzureIoTClient | 3:40f482ed0be8 | 918 | char tempAddress[DEFAULT_TEMP_STRING_LEN]; |
AzureIoTClient | 3:40f482ed0be8 | 919 | (void)snprintf(tempAddress, DEFAULT_TEMP_STRING_LEN, "%s.%s", upperConfig->iotHubName, upperConfig->iotHubSuffix); |
AzureIoTClient | 3:40f482ed0be8 | 920 | if ((state->hostAddress = STRING_construct(tempAddress)) == NULL) |
AzureIoTClient | 3:40f482ed0be8 | 921 | { |
AzureIoTClient | 7:7fdd306e6224 | 922 | LogError("failure constructing host address."); |
AzureIoTClient | 7:7fdd306e6224 | 923 | STRING_delete(state->devicesPath); |
AzureIoTClient | 7:7fdd306e6224 | 924 | if (state->transport_creds.credential_type == DEVICE_KEY) |
AzureIoTClient | 7:7fdd306e6224 | 925 | { |
AzureIoTClient | 7:7fdd306e6224 | 926 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 927 | } |
AzureIoTClient | 7:7fdd306e6224 | 928 | else if (state->transport_creds.credential_type == SAS_TOKEN_FROM_USER) |
AzureIoTClient | 7:7fdd306e6224 | 929 | { |
AzureIoTClient | 7:7fdd306e6224 | 930 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 931 | } |
AzureIoTClient | 3:40f482ed0be8 | 932 | STRING_delete(state->mqttEventTopic); |
AzureIoTClient | 3:40f482ed0be8 | 933 | STRING_delete(state->mqttMessageTopic); |
AzureIoTClient | 3:40f482ed0be8 | 934 | STRING_delete(state->device_id); |
AzureIoTClient | 3:40f482ed0be8 | 935 | free(state); |
AzureIoTClient | 3:40f482ed0be8 | 936 | state = NULL; |
AzureIoTClient | 3:40f482ed0be8 | 937 | } |
AzureIoTClient | 3:40f482ed0be8 | 938 | else if ((state->configPassedThroughUsername = buildConfigForUsername(upperConfig)) == NULL) |
AzureIoTClient | 3:40f482ed0be8 | 939 | { |
AzureIoTClient | 7:7fdd306e6224 | 940 | STRING_delete(state->devicesPath); |
AzureIoTClient | 7:7fdd306e6224 | 941 | if (state->transport_creds.credential_type == DEVICE_KEY) |
AzureIoTClient | 7:7fdd306e6224 | 942 | { |
AzureIoTClient | 7:7fdd306e6224 | 943 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 944 | } |
AzureIoTClient | 7:7fdd306e6224 | 945 | else if (state->transport_creds.credential_type == SAS_TOKEN_FROM_USER) |
AzureIoTClient | 7:7fdd306e6224 | 946 | { |
AzureIoTClient | 7:7fdd306e6224 | 947 | STRING_delete(state->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 948 | } |
AzureIoTClient | 3:40f482ed0be8 | 949 | STRING_delete(state->hostAddress); |
AzureIoTClient | 3:40f482ed0be8 | 950 | STRING_delete(state->mqttEventTopic); |
AzureIoTClient | 3:40f482ed0be8 | 951 | STRING_delete(state->mqttMessageTopic); |
AzureIoTClient | 3:40f482ed0be8 | 952 | STRING_delete(state->device_id); |
AzureIoTClient | 3:40f482ed0be8 | 953 | free(state); |
AzureIoTClient | 3:40f482ed0be8 | 954 | state = NULL; |
AzureIoTClient | 3:40f482ed0be8 | 955 | } |
AzureIoTClient | 3:40f482ed0be8 | 956 | else |
AzureIoTClient | 3:40f482ed0be8 | 957 | { |
AzureIoTClient | 3:40f482ed0be8 | 958 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_010: [IoTHubTransportMqtt_Create shall allocate memory to save its internal state where all topics, hostname, device_id, device_key, sasTokenSr and client handle shall be saved.] */ |
AzureIoTClient | 3:40f482ed0be8 | 959 | DList_InitializeListHead(&(state->waitingForAck)); |
AzureIoTClient | 3:40f482ed0be8 | 960 | state->destroyCalled = false; |
AzureIoTClient | 3:40f482ed0be8 | 961 | state->isRegistered = false; |
AzureIoTClient | 3:40f482ed0be8 | 962 | state->subscribed = false; |
AzureIoTClient | 3:40f482ed0be8 | 963 | state->connected = false; |
AzureIoTClient | 3:40f482ed0be8 | 964 | state->receiveMessages = false; |
AzureIoTClient | 3:40f482ed0be8 | 965 | state->packetId = 1; |
AzureIoTClient | 3:40f482ed0be8 | 966 | state->llClientHandle = NULL; |
AzureIoTClient | 3:40f482ed0be8 | 967 | state->xioTransport = NULL; |
AzureIoTClient | 3:40f482ed0be8 | 968 | state->portNum = DEFAULT_PORT_NUMBER; |
AzureIoTClient | 3:40f482ed0be8 | 969 | state->waitingToSend = waitingToSend; |
AzureIoTClient | 3:40f482ed0be8 | 970 | state->currPacketState = CONNECT_TYPE; |
AzureIoTClient | 3:40f482ed0be8 | 971 | state->keepAliveValue = DEFAULT_MQTT_KEEPALIVE; |
AzureIoTClient | 3:40f482ed0be8 | 972 | state->connectFailCount = 0; |
AzureIoTClient | 3:40f482ed0be8 | 973 | state->connectTick = 0; |
AzureIoTClient | 3:40f482ed0be8 | 974 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 975 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 976 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 977 | } |
AzureIoTClient | 4:e472f5ce3473 | 978 | return state; |
Azure.IoT Build | 0:5e72a75c31b8 | 979 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 980 | |
AzureIoTClient | 4:e472f5ce3473 | 981 | static TRANSPORT_LL_HANDLE IoTHubTransportMqtt_Create(const IOTHUBTRANSPORT_CONFIG* config) |
Azure.IoT Build | 0:5e72a75c31b8 | 982 | { |
AzureIoTClient | 4:e472f5ce3473 | 983 | PMQTTTRANSPORT_HANDLE_DATA result; |
AzureIoTClient | 4:e472f5ce3473 | 984 | size_t deviceIdSize; |
AzureIoTClient | 3:40f482ed0be8 | 985 | |
AzureIoTClient | 4:e472f5ce3473 | 986 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_001: [If parameter config is NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 987 | if (config == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 988 | { |
AzureIoTClient | 4:e472f5ce3473 | 989 | LogError("Invalid Argument: Config Parameter is NULL."); |
AzureIoTClient | 4:e472f5ce3473 | 990 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 991 | } |
AzureIoTClient | 4:e472f5ce3473 | 992 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_002: [If the parameter config's variables upperConfig or waitingToSend are NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 993 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_003: [If the upperConfig's variables deviceId, both deviceKey and deviceSasToken, iotHubName, protocol, or iotHubSuffix are NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 7:7fdd306e6224 | 994 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_03_003: [If both deviceKey & deviceSasToken fields are NOT NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 7:7fdd306e6224 | 995 | else if (config->upperConfig == NULL || |
AzureIoTClient | 7:7fdd306e6224 | 996 | config->upperConfig->protocol == NULL || |
AzureIoTClient | 7:7fdd306e6224 | 997 | config->upperConfig->deviceId == NULL || |
AzureIoTClient | 7:7fdd306e6224 | 998 | ((config->upperConfig->deviceKey != NULL) && (config->upperConfig->deviceSasToken != NULL)) || |
AzureIoTClient | 7:7fdd306e6224 | 999 | config->upperConfig->iotHubName == NULL || |
AzureIoTClient | 7:7fdd306e6224 | 1000 | config->upperConfig->iotHubSuffix == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1001 | { |
AzureIoTClient | 4:e472f5ce3473 | 1002 | LogError("Invalid Argument: upperConfig structure contains an invalid parameter"); |
AzureIoTClient | 4:e472f5ce3473 | 1003 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1004 | } |
AzureIoTClient | 4:e472f5ce3473 | 1005 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_002: [If the parameter config's variables upperConfig or waitingToSend are NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1006 | else if (config->waitingToSend == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1007 | { |
AzureIoTClient | 4:e472f5ce3473 | 1008 | LogError("Invalid Argument: waitingToSend is NULL)"); |
AzureIoTClient | 4:e472f5ce3473 | 1009 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1010 | } |
AzureIoTClient | 4:e472f5ce3473 | 1011 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_006: [If the upperConfig's variables deviceId is an empty strings or length is greater then 128 then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1012 | else if ( ( (deviceIdSize = strlen(config->upperConfig->deviceId)) > 128U) || (deviceIdSize == 0) ) |
AzureIoTClient | 4:e472f5ce3473 | 1013 | { |
AzureIoTClient | 4:e472f5ce3473 | 1014 | LogError("Invalid Argument: DeviceId is of an invalid size"); |
AzureIoTClient | 4:e472f5ce3473 | 1015 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1016 | } |
AzureIoTClient | 4:e472f5ce3473 | 1017 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_003: [If the upperConfig's variables deviceId, both deviceKey and deviceSasToken, iotHubName, protocol, or iotHubSuffix are NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1018 | else if ((config->upperConfig->deviceKey != NULL) && (strlen(config->upperConfig->deviceKey) == 0)) |
AzureIoTClient | 4:e472f5ce3473 | 1019 | { |
AzureIoTClient | 4:e472f5ce3473 | 1020 | LogError("Invalid Argument: deviceKey is empty"); |
AzureIoTClient | 4:e472f5ce3473 | 1021 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1022 | } |
AzureIoTClient | 4:e472f5ce3473 | 1023 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_003: [If the upperConfig's variables deviceId, both deviceKey and deviceSasToken, iotHubName, protocol, or iotHubSuffix are NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1024 | else if ((config->upperConfig->deviceSasToken != NULL) && (strlen(config->upperConfig->deviceSasToken) == 0)) |
AzureIoTClient | 4:e472f5ce3473 | 1025 | { |
AzureIoTClient | 4:e472f5ce3473 | 1026 | LogError("Invalid Argument: deviceSasToken is empty"); |
AzureIoTClient | 4:e472f5ce3473 | 1027 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1028 | } |
AzureIoTClient | 7:7fdd306e6224 | 1029 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_003: [If the upperConfig's variables deviceId, deviceKey, iotHubName, protocol, or iotHubSuffix are NULL then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 7:7fdd306e6224 | 1030 | else if (strlen(config->upperConfig->iotHubName) == 0) |
Azure.IoT Build | 0:5e72a75c31b8 | 1031 | { |
AzureIoTClient | 7:7fdd306e6224 | 1032 | LogError("Invalid Argument: iotHubName is empty"); |
Azure.IoT Build | 0:5e72a75c31b8 | 1033 | result = NULL; |
Azure.IoT Build | 0:5e72a75c31b8 | 1034 | } |
AzureIoTClient | 7:7fdd306e6224 | 1035 | else if ((g_msgTickCounter = tickcounter_create()) == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1036 | { |
AzureIoTClient | 4:e472f5ce3473 | 1037 | LogError("Invalid Argument: iotHubName is empty"); |
AzureIoTClient | 4:e472f5ce3473 | 1038 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1039 | } |
AzureIoTClient | 4:e472f5ce3473 | 1040 | else |
AzureIoTClient | 4:e472f5ce3473 | 1041 | { |
AzureIoTClient | 4:e472f5ce3473 | 1042 | result = InitializeTransportHandleData(config->upperConfig, config->waitingToSend); |
AzureIoTClient | 7:7fdd306e6224 | 1043 | if (result == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1044 | { |
AzureIoTClient | 7:7fdd306e6224 | 1045 | tickcounter_destroy(g_msgTickCounter); |
AzureIoTClient | 4:e472f5ce3473 | 1046 | } |
AzureIoTClient | 4:e472f5ce3473 | 1047 | } |
AzureIoTClient | 4:e472f5ce3473 | 1048 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_009: [If any error is encountered then IoTHubTransportMqtt_Create shall return NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1049 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_011: [On Success IoTHubTransportMqtt_Create shall return a non-NULL value.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1050 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 1051 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1052 | |
Azure.IoT Build | 0:5e72a75c31b8 | 1053 | static void DisconnectFromClient(PMQTTTRANSPORT_HANDLE_DATA transportState) |
Azure.IoT Build | 0:5e72a75c31b8 | 1054 | { |
AzureIoTClient | 4:e472f5ce3473 | 1055 | (void)mqtt_client_disconnect(transportState->mqttClient); |
AzureIoTClient | 4:e472f5ce3473 | 1056 | xio_destroy(transportState->xioTransport); |
AzureIoTClient | 4:e472f5ce3473 | 1057 | transportState->xioTransport = NULL; |
Azure.IoT Build | 0:5e72a75c31b8 | 1058 | |
AzureIoTClient | 4:e472f5ce3473 | 1059 | transportState->connected = false; |
AzureIoTClient | 4:e472f5ce3473 | 1060 | transportState->currPacketState = DISCONNECT_TYPE; |
Azure.IoT Build | 0:5e72a75c31b8 | 1061 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1062 | |
AzureIoTClient | 4:e472f5ce3473 | 1063 | static void IoTHubTransportMqtt_Destroy(TRANSPORT_LL_HANDLE handle) |
Azure.IoT Build | 0:5e72a75c31b8 | 1064 | { |
AzureIoTClient | 4:e472f5ce3473 | 1065 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_012: [IoTHubTransportMqtt_Destroy shall do nothing if parameter handle is NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1066 | PMQTTTRANSPORT_HANDLE_DATA transportState = (PMQTTTRANSPORT_HANDLE_DATA)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1067 | if (transportState != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1068 | { |
AzureIoTClient | 4:e472f5ce3473 | 1069 | transportState->destroyCalled = true; |
Azure.IoT Build | 0:5e72a75c31b8 | 1070 | |
AzureIoTClient | 4:e472f5ce3473 | 1071 | DisconnectFromClient(transportState); |
Azure.IoT Build | 0:5e72a75c31b8 | 1072 | |
AzureIoTClient | 4:e472f5ce3473 | 1073 | //Empty the Waiting for Ack Messages. |
AzureIoTClient | 4:e472f5ce3473 | 1074 | while (!DList_IsListEmpty(&transportState->waitingForAck)) |
AzureIoTClient | 4:e472f5ce3473 | 1075 | { |
AzureIoTClient | 4:e472f5ce3473 | 1076 | PDLIST_ENTRY currentEntry = DList_RemoveHeadList(&transportState->waitingForAck); |
AzureIoTClient | 4:e472f5ce3473 | 1077 | MQTT_MESSAGE_DETAILS_LIST* mqttMsgEntry = containingRecord(currentEntry, MQTT_MESSAGE_DETAILS_LIST, entry); |
Azure.IoT Build | 5:73603e7a6542 | 1078 | sendMsgComplete(mqttMsgEntry->iotHubMessageEntry, transportState, IOTHUB_CLIENT_CONFIRMATION_BECAUSE_DESTROY); |
AzureIoTClient | 4:e472f5ce3473 | 1079 | free(mqttMsgEntry); |
AzureIoTClient | 4:e472f5ce3473 | 1080 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1081 | |
AzureIoTClient | 7:7fdd306e6224 | 1082 | switch (transportState->transport_creds.credential_type) |
AzureIoTClient | 7:7fdd306e6224 | 1083 | { |
AzureIoTClient | 7:7fdd306e6224 | 1084 | case SAS_TOKEN_FROM_USER: |
AzureIoTClient | 7:7fdd306e6224 | 1085 | STRING_delete(transportState->transport_creds.CREDENTIAL_VALUE.deviceSasToken); |
AzureIoTClient | 7:7fdd306e6224 | 1086 | break; |
AzureIoTClient | 7:7fdd306e6224 | 1087 | case DEVICE_KEY: |
AzureIoTClient | 7:7fdd306e6224 | 1088 | STRING_delete(transportState->transport_creds.CREDENTIAL_VALUE.deviceKey); |
AzureIoTClient | 7:7fdd306e6224 | 1089 | STRING_delete(transportState->devicesPath); |
AzureIoTClient | 7:7fdd306e6224 | 1090 | break; |
AzureIoTClient | 7:7fdd306e6224 | 1091 | case X509: |
AzureIoTClient | 7:7fdd306e6224 | 1092 | default: |
AzureIoTClient | 7:7fdd306e6224 | 1093 | break; |
AzureIoTClient | 7:7fdd306e6224 | 1094 | } |
AzureIoTClient | 7:7fdd306e6224 | 1095 | |
AzureIoTClient | 4:e472f5ce3473 | 1096 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_014: [IoTHubTransportMqtt_Destroy shall free all the resources currently in use.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1097 | mqtt_client_deinit(transportState->mqttClient); |
AzureIoTClient | 4:e472f5ce3473 | 1098 | STRING_delete(transportState->mqttEventTopic); |
AzureIoTClient | 4:e472f5ce3473 | 1099 | STRING_delete(transportState->mqttMessageTopic); |
AzureIoTClient | 4:e472f5ce3473 | 1100 | STRING_delete(transportState->device_id); |
AzureIoTClient | 4:e472f5ce3473 | 1101 | STRING_delete(transportState->hostAddress); |
AzureIoTClient | 4:e472f5ce3473 | 1102 | STRING_delete(transportState->configPassedThroughUsername); |
AzureIoTClient | 4:e472f5ce3473 | 1103 | tickcounter_destroy(g_msgTickCounter); |
AzureIoTClient | 4:e472f5ce3473 | 1104 | free(transportState); |
AzureIoTClient | 4:e472f5ce3473 | 1105 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1106 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1107 | |
AzureIoTClient | 4:e472f5ce3473 | 1108 | static int IoTHubTransportMqtt_Subscribe(IOTHUB_DEVICE_HANDLE handle) |
Azure.IoT Build | 0:5e72a75c31b8 | 1109 | { |
AzureIoTClient | 4:e472f5ce3473 | 1110 | int result; |
AzureIoTClient | 4:e472f5ce3473 | 1111 | PMQTTTRANSPORT_HANDLE_DATA transportState = (PMQTTTRANSPORT_HANDLE_DATA)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1112 | if (transportState == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1113 | { |
AzureIoTClient | 4:e472f5ce3473 | 1114 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_015: [If parameter handle is NULL than IoTHubTransportMqtt_Subscribe shall return a non-zero value.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1115 | LogError("Invalid handle parameter. NULL."); |
AzureIoTClient | 4:e472f5ce3473 | 1116 | result = __LINE__; |
AzureIoTClient | 4:e472f5ce3473 | 1117 | } |
AzureIoTClient | 4:e472f5ce3473 | 1118 | else |
AzureIoTClient | 4:e472f5ce3473 | 1119 | { |
AzureIoTClient | 4:e472f5ce3473 | 1120 | /* Code_SRS_IOTHUB_MQTT_TRANSPORT_07_016: [IoTHubTransportMqtt_Subscribe shall set a flag to enable mqtt_client_subscribe to be called to subscribe to the Message Topic.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1121 | transportState->receiveMessages = true; |
AzureIoTClient | 4:e472f5ce3473 | 1122 | /* Code_SRS_IOTHUB_MQTT_TRANSPORT_07_035: [If current packet state is not CONNACT, DISCONNECT_TYPE, or PACKET_TYPE_ERROR then IoTHubTransportMqtt_Subscribe shall set the packet state to SUBSCRIBE_TYPE.]*/ |
AzureIoTClient | 4:e472f5ce3473 | 1123 | if (transportState->currPacketState != CONNACK_TYPE && |
AzureIoTClient | 4:e472f5ce3473 | 1124 | transportState->currPacketState != CONNECT_TYPE && |
AzureIoTClient | 4:e472f5ce3473 | 1125 | transportState->currPacketState != DISCONNECT_TYPE && |
AzureIoTClient | 4:e472f5ce3473 | 1126 | transportState->currPacketState != PACKET_TYPE_ERROR) |
AzureIoTClient | 4:e472f5ce3473 | 1127 | { |
AzureIoTClient | 4:e472f5ce3473 | 1128 | transportState->currPacketState = SUBSCRIBE_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 1129 | } |
AzureIoTClient | 4:e472f5ce3473 | 1130 | result = 0; |
AzureIoTClient | 4:e472f5ce3473 | 1131 | } |
AzureIoTClient | 4:e472f5ce3473 | 1132 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 1133 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1134 | |
AzureIoTClient | 4:e472f5ce3473 | 1135 | static void IoTHubTransportMqtt_Unsubscribe(IOTHUB_DEVICE_HANDLE handle) |
Azure.IoT Build | 0:5e72a75c31b8 | 1136 | { |
AzureIoTClient | 4:e472f5ce3473 | 1137 | PMQTTTRANSPORT_HANDLE_DATA transportState = (PMQTTTRANSPORT_HANDLE_DATA)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1138 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_019: [If parameter handle is NULL then IoTHubTransportMqtt_Unsubscribe shall do nothing.] */ |
AzureIoTClient | 9:50744bd8239e | 1139 | if (transportState != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1140 | { |
AzureIoTClient | 4:e472f5ce3473 | 1141 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_020: [IoTHubTransportMqtt_Unsubscribe shall call mqtt_client_unsubscribe to unsubscribe the mqtt message topic.] */ |
AzureIoTClient | 6:16875b609849 | 1142 | const char* unsubscribe[1]; |
AzureIoTClient | 6:16875b609849 | 1143 | unsubscribe[0] = STRING_c_str(transportState->mqttMessageTopic); |
AzureIoTClient | 6:16875b609849 | 1144 | (void)mqtt_client_unsubscribe(transportState->mqttClient, get_next_packet_id(transportState), unsubscribe, 1); |
AzureIoTClient | 4:e472f5ce3473 | 1145 | transportState->subscribed = false; |
AzureIoTClient | 4:e472f5ce3473 | 1146 | transportState->receiveMessages = false; |
AzureIoTClient | 4:e472f5ce3473 | 1147 | } |
AzureIoTClient | 4:e472f5ce3473 | 1148 | else |
AzureIoTClient | 4:e472f5ce3473 | 1149 | { |
AzureIoTClient | 4:e472f5ce3473 | 1150 | LogError("Invalid argument to unsubscribe (NULL)."); |
AzureIoTClient | 4:e472f5ce3473 | 1151 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1152 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1153 | |
AzureIoTClient | 4:e472f5ce3473 | 1154 | static void IoTHubTransportMqtt_DoWork(TRANSPORT_LL_HANDLE handle, IOTHUB_CLIENT_LL_HANDLE iotHubClientHandle) |
Azure.IoT Build | 0:5e72a75c31b8 | 1155 | { |
AzureIoTClient | 4:e472f5ce3473 | 1156 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_026: [IoTHubTransportMqtt_DoWork shall do nothing if parameter handle and/or iotHubClientHandle is NULL.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1157 | PMQTTTRANSPORT_HANDLE_DATA transportState = (PMQTTTRANSPORT_HANDLE_DATA)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1158 | if (transportState != NULL && iotHubClientHandle != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1159 | { |
AzureIoTClient | 4:e472f5ce3473 | 1160 | transportState->llClientHandle = iotHubClientHandle; |
Azure.IoT Build | 0:5e72a75c31b8 | 1161 | |
AzureIoTClient | 4:e472f5ce3473 | 1162 | if (InitializeConnection(transportState) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 1163 | { |
AzureIoTClient | 4:e472f5ce3473 | 1164 | // Don't want to flood the logs with failures here |
AzureIoTClient | 4:e472f5ce3473 | 1165 | } |
AzureIoTClient | 4:e472f5ce3473 | 1166 | else |
AzureIoTClient | 4:e472f5ce3473 | 1167 | { |
AzureIoTClient | 4:e472f5ce3473 | 1168 | if (transportState->currPacketState == CONNACK_TYPE || transportState->currPacketState == SUBSCRIBE_TYPE) |
AzureIoTClient | 4:e472f5ce3473 | 1169 | { |
AzureIoTClient | 4:e472f5ce3473 | 1170 | (void)SubscribeToMqttProtocol(transportState); |
AzureIoTClient | 4:e472f5ce3473 | 1171 | } |
AzureIoTClient | 4:e472f5ce3473 | 1172 | else if (transportState->currPacketState == SUBACK_TYPE) |
AzureIoTClient | 4:e472f5ce3473 | 1173 | { |
AzureIoTClient | 4:e472f5ce3473 | 1174 | // Publish can be called now |
AzureIoTClient | 4:e472f5ce3473 | 1175 | transportState->currPacketState = PUBLISH_TYPE; |
AzureIoTClient | 4:e472f5ce3473 | 1176 | } |
AzureIoTClient | 4:e472f5ce3473 | 1177 | else if (transportState->currPacketState == PUBLISH_TYPE) |
AzureIoTClient | 4:e472f5ce3473 | 1178 | { |
AzureIoTClient | 4:e472f5ce3473 | 1179 | PDLIST_ENTRY currentListEntry = transportState->waitingForAck.Flink; |
AzureIoTClient | 4:e472f5ce3473 | 1180 | while (currentListEntry != &transportState->waitingForAck) |
AzureIoTClient | 4:e472f5ce3473 | 1181 | { |
AzureIoTClient | 4:e472f5ce3473 | 1182 | MQTT_MESSAGE_DETAILS_LIST* mqttMsgEntry = containingRecord(currentListEntry, MQTT_MESSAGE_DETAILS_LIST, entry); |
AzureIoTClient | 4:e472f5ce3473 | 1183 | DLIST_ENTRY nextListEntry; |
AzureIoTClient | 4:e472f5ce3473 | 1184 | nextListEntry.Flink = currentListEntry->Flink; |
Azure.IoT Build | 0:5e72a75c31b8 | 1185 | |
AzureIoTClient | 4:e472f5ce3473 | 1186 | uint64_t current_ms; |
AzureIoTClient | 4:e472f5ce3473 | 1187 | (void)tickcounter_get_current_ms(g_msgTickCounter, ¤t_ms); |
AzureIoTClient | 4:e472f5ce3473 | 1188 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_033: [IoTHubTransportMqtt_DoWork shall iterate through the Waiting Acknowledge messages looking for any message that has been waiting longer than 2 min.]*/ |
AzureIoTClient | 4:e472f5ce3473 | 1189 | if (((current_ms - mqttMsgEntry->msgPublishTime) / 1000) > RESEND_TIMEOUT_VALUE_MIN) |
AzureIoTClient | 4:e472f5ce3473 | 1190 | { |
AzureIoTClient | 4:e472f5ce3473 | 1191 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_034: [If IoTHubTransportMqtt_DoWork has resent the message two times then it shall fail the message] */ |
AzureIoTClient | 4:e472f5ce3473 | 1192 | if (mqttMsgEntry->retryCount >= MAX_SEND_RECOUNT_LIMIT) |
AzureIoTClient | 4:e472f5ce3473 | 1193 | { |
AzureIoTClient | 4:e472f5ce3473 | 1194 | (void)DList_RemoveEntryList(currentListEntry); |
Azure.IoT Build | 5:73603e7a6542 | 1195 | sendMsgComplete(mqttMsgEntry->iotHubMessageEntry, transportState, IOTHUB_CLIENT_CONFIRMATION_MESSAGE_TIMEOUT); |
AzureIoTClient | 4:e472f5ce3473 | 1196 | free(mqttMsgEntry); |
AzureIoTClient | 4:e472f5ce3473 | 1197 | } |
AzureIoTClient | 4:e472f5ce3473 | 1198 | else |
AzureIoTClient | 4:e472f5ce3473 | 1199 | { |
AzureIoTClient | 4:e472f5ce3473 | 1200 | size_t messageLength; |
AzureIoTClient | 4:e472f5ce3473 | 1201 | const unsigned char* messagePayload = RetrieveMessagePayload(mqttMsgEntry->iotHubMessageEntry->messageHandle, &messageLength); |
AzureIoTClient | 4:e472f5ce3473 | 1202 | if (messageLength == 0 || messagePayload == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1203 | { |
AzureIoTClient | 4:e472f5ce3473 | 1204 | LogError("Failure from creating Message IoTHubMessage_GetData"); |
AzureIoTClient | 4:e472f5ce3473 | 1205 | } |
AzureIoTClient | 4:e472f5ce3473 | 1206 | else |
AzureIoTClient | 4:e472f5ce3473 | 1207 | { |
AzureIoTClient | 4:e472f5ce3473 | 1208 | if (publishMqttMessage(transportState, mqttMsgEntry, messagePayload, messageLength) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 1209 | { |
AzureIoTClient | 4:e472f5ce3473 | 1210 | (void)DList_RemoveEntryList(currentListEntry); |
Azure.IoT Build | 5:73603e7a6542 | 1211 | sendMsgComplete(mqttMsgEntry->iotHubMessageEntry, transportState, IOTHUB_CLIENT_CONFIRMATION_ERROR); |
AzureIoTClient | 4:e472f5ce3473 | 1212 | free(mqttMsgEntry); |
AzureIoTClient | 4:e472f5ce3473 | 1213 | } |
AzureIoTClient | 4:e472f5ce3473 | 1214 | } |
AzureIoTClient | 4:e472f5ce3473 | 1215 | } |
AzureIoTClient | 4:e472f5ce3473 | 1216 | } |
AzureIoTClient | 4:e472f5ce3473 | 1217 | currentListEntry = nextListEntry.Flink; |
AzureIoTClient | 4:e472f5ce3473 | 1218 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1219 | |
AzureIoTClient | 4:e472f5ce3473 | 1220 | currentListEntry = transportState->waitingToSend->Flink; |
AzureIoTClient | 4:e472f5ce3473 | 1221 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_027: [IoTHubTransportMqtt_DoWork shall inspect the waitingToSend DLIST passed in config structure.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1222 | while (currentListEntry != transportState->waitingToSend) |
AzureIoTClient | 4:e472f5ce3473 | 1223 | { |
AzureIoTClient | 4:e472f5ce3473 | 1224 | IOTHUB_MESSAGE_LIST* iothubMsgList = containingRecord(currentListEntry, IOTHUB_MESSAGE_LIST, entry); |
AzureIoTClient | 4:e472f5ce3473 | 1225 | DLIST_ENTRY savedFromCurrentListEntry; |
AzureIoTClient | 4:e472f5ce3473 | 1226 | savedFromCurrentListEntry.Flink = currentListEntry->Flink; |
Azure.IoT Build | 0:5e72a75c31b8 | 1227 | |
AzureIoTClient | 4:e472f5ce3473 | 1228 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_027: [IoTHubTransportMqtt_DoWork shall inspect the waitingToSend DLIST passed in config structure.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1229 | size_t messageLength; |
AzureIoTClient | 4:e472f5ce3473 | 1230 | const unsigned char* messagePayload = RetrieveMessagePayload(iothubMsgList->messageHandle, &messageLength); |
AzureIoTClient | 4:e472f5ce3473 | 1231 | if (messageLength == 0 || messagePayload == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1232 | { |
AzureIoTClient | 4:e472f5ce3473 | 1233 | LogError("Failure result from IoTHubMessage_GetData"); |
AzureIoTClient | 4:e472f5ce3473 | 1234 | } |
AzureIoTClient | 4:e472f5ce3473 | 1235 | else |
AzureIoTClient | 4:e472f5ce3473 | 1236 | { |
AzureIoTClient | 4:e472f5ce3473 | 1237 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_029: [IoTHubTransportMqtt_DoWork shall create a MQTT_MESSAGE_HANDLE and pass this to a call to mqtt_client_publish.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1238 | MQTT_MESSAGE_DETAILS_LIST* mqttMsgEntry = (MQTT_MESSAGE_DETAILS_LIST*)malloc(sizeof(MQTT_MESSAGE_DETAILS_LIST)); |
AzureIoTClient | 4:e472f5ce3473 | 1239 | if (mqttMsgEntry == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1240 | { |
AzureIoTClient | 4:e472f5ce3473 | 1241 | LogError("Allocation Error: Failure allocating MQTT Message Detail List."); |
AzureIoTClient | 4:e472f5ce3473 | 1242 | } |
AzureIoTClient | 4:e472f5ce3473 | 1243 | else |
AzureIoTClient | 4:e472f5ce3473 | 1244 | { |
AzureIoTClient | 4:e472f5ce3473 | 1245 | mqttMsgEntry->retryCount = 0; |
AzureIoTClient | 4:e472f5ce3473 | 1246 | mqttMsgEntry->iotHubMessageEntry = iothubMsgList; |
AzureIoTClient | 4:e472f5ce3473 | 1247 | if (publishMqttMessage(transportState, mqttMsgEntry, messagePayload, messageLength) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 1248 | { |
AzureIoTClient | 4:e472f5ce3473 | 1249 | (void)(DList_RemoveEntryList(currentListEntry)); |
Azure.IoT Build | 5:73603e7a6542 | 1250 | sendMsgComplete(iothubMsgList, transportState, IOTHUB_CLIENT_CONFIRMATION_ERROR); |
AzureIoTClient | 4:e472f5ce3473 | 1251 | free(mqttMsgEntry); |
AzureIoTClient | 4:e472f5ce3473 | 1252 | } |
AzureIoTClient | 4:e472f5ce3473 | 1253 | else |
AzureIoTClient | 4:e472f5ce3473 | 1254 | { |
AzureIoTClient | 4:e472f5ce3473 | 1255 | (void)(DList_RemoveEntryList(currentListEntry)); |
AzureIoTClient | 4:e472f5ce3473 | 1256 | DList_InsertTailList(&(transportState->waitingForAck), &(mqttMsgEntry->entry)); |
AzureIoTClient | 4:e472f5ce3473 | 1257 | } |
AzureIoTClient | 4:e472f5ce3473 | 1258 | } |
AzureIoTClient | 4:e472f5ce3473 | 1259 | } |
AzureIoTClient | 4:e472f5ce3473 | 1260 | currentListEntry = savedFromCurrentListEntry.Flink; |
AzureIoTClient | 4:e472f5ce3473 | 1261 | } |
AzureIoTClient | 4:e472f5ce3473 | 1262 | } |
AzureIoTClient | 4:e472f5ce3473 | 1263 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_030: [IoTHubTransportMqtt_DoWork shall call mqtt_client_dowork everytime it is called if it is connected.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1264 | mqtt_client_dowork(transportState->mqttClient); |
AzureIoTClient | 4:e472f5ce3473 | 1265 | } |
AzureIoTClient | 4:e472f5ce3473 | 1266 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1267 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1268 | |
AzureIoTClient | 4:e472f5ce3473 | 1269 | static IOTHUB_CLIENT_RESULT IoTHubTransportMqtt_GetSendStatus(IOTHUB_DEVICE_HANDLE handle, IOTHUB_CLIENT_STATUS *iotHubClientStatus) |
Azure.IoT Build | 0:5e72a75c31b8 | 1270 | { |
AzureIoTClient | 4:e472f5ce3473 | 1271 | IOTHUB_CLIENT_RESULT result; |
Azure.IoT Build | 0:5e72a75c31b8 | 1272 | |
AzureIoTClient | 4:e472f5ce3473 | 1273 | if (handle == NULL || iotHubClientStatus == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1274 | { |
AzureIoTClient | 4:e472f5ce3473 | 1275 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_023: [IoTHubTransportMqtt_GetSendStatus shall return IOTHUB_CLIENT_INVALID_ARG if called with NULL parameter.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1276 | LogError("invalid arument."); |
AzureIoTClient | 4:e472f5ce3473 | 1277 | result = IOTHUB_CLIENT_INVALID_ARG; |
AzureIoTClient | 4:e472f5ce3473 | 1278 | } |
AzureIoTClient | 4:e472f5ce3473 | 1279 | else |
AzureIoTClient | 4:e472f5ce3473 | 1280 | { |
AzureIoTClient | 4:e472f5ce3473 | 1281 | MQTTTRANSPORT_HANDLE_DATA* handleData = (MQTTTRANSPORT_HANDLE_DATA*)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1282 | if (!DList_IsListEmpty(handleData->waitingToSend) || !DList_IsListEmpty(&(handleData->waitingForAck))) |
AzureIoTClient | 4:e472f5ce3473 | 1283 | { |
AzureIoTClient | 4:e472f5ce3473 | 1284 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_025: [IoTHubTransportMqtt_GetSendStatus shall return IOTHUB_CLIENT_OK and status IOTHUB_CLIENT_SEND_STATUS_BUSY if there are currently event items to be sent or being sent.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1285 | *iotHubClientStatus = IOTHUB_CLIENT_SEND_STATUS_BUSY; |
AzureIoTClient | 4:e472f5ce3473 | 1286 | } |
AzureIoTClient | 4:e472f5ce3473 | 1287 | else |
AzureIoTClient | 4:e472f5ce3473 | 1288 | { |
AzureIoTClient | 4:e472f5ce3473 | 1289 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_024: [IoTHubTransportMqtt_GetSendStatus shall return IOTHUB_CLIENT_OK and status IOTHUB_CLIENT_SEND_STATUS_IDLE if there are currently no event items to be sent or being sent.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1290 | *iotHubClientStatus = IOTHUB_CLIENT_SEND_STATUS_IDLE; |
AzureIoTClient | 4:e472f5ce3473 | 1291 | } |
AzureIoTClient | 4:e472f5ce3473 | 1292 | result = IOTHUB_CLIENT_OK; |
AzureIoTClient | 4:e472f5ce3473 | 1293 | } |
AzureIoTClient | 4:e472f5ce3473 | 1294 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 1295 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1296 | |
AzureIoTClient | 4:e472f5ce3473 | 1297 | static IOTHUB_CLIENT_RESULT IoTHubTransportMqtt_SetOption(TRANSPORT_LL_HANDLE handle, const char* option, const void* value) |
Azure.IoT Build | 0:5e72a75c31b8 | 1298 | { |
AzureIoTClient | 4:e472f5ce3473 | 1299 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_021: [If any parameter is NULL then IoTHubTransportMqtt_SetOption shall return IOTHUB_CLIENT_INVALID_ARG.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1300 | IOTHUB_CLIENT_RESULT result; |
AzureIoTClient | 4:e472f5ce3473 | 1301 | if ( |
AzureIoTClient | 4:e472f5ce3473 | 1302 | (handle == NULL) || |
AzureIoTClient | 4:e472f5ce3473 | 1303 | (option == NULL) || |
AzureIoTClient | 4:e472f5ce3473 | 1304 | (value == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1305 | ) |
AzureIoTClient | 4:e472f5ce3473 | 1306 | { |
AzureIoTClient | 4:e472f5ce3473 | 1307 | result = IOTHUB_CLIENT_INVALID_ARG; |
AzureIoTClient | 4:e472f5ce3473 | 1308 | LogError("invalid parameter (NULL) passed to clientTransportAMQP_SetOption."); |
AzureIoTClient | 4:e472f5ce3473 | 1309 | } |
AzureIoTClient | 4:e472f5ce3473 | 1310 | else |
AzureIoTClient | 4:e472f5ce3473 | 1311 | { |
AzureIoTClient | 4:e472f5ce3473 | 1312 | MQTTTRANSPORT_HANDLE_DATA* transportState = (MQTTTRANSPORT_HANDLE_DATA*)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1313 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_031: [If the option parameter is set to "logtrace" then the value shall be a bool_ptr and the value will determine if the mqtt client log is on or off.] */ |
AzureIoTClient | 8:418a3b812584 | 1314 | if (strcmp(OPTION_LOG_TRACE, option) == 0) |
AzureIoTClient | 4:e472f5ce3473 | 1315 | { |
AzureIoTClient | 4:e472f5ce3473 | 1316 | bool* traceVal = (bool*)value; |
AzureIoTClient | 4:e472f5ce3473 | 1317 | mqtt_client_set_trace(transportState->mqttClient, *traceVal, *traceVal); |
AzureIoTClient | 4:e472f5ce3473 | 1318 | result = IOTHUB_CLIENT_OK; |
AzureIoTClient | 4:e472f5ce3473 | 1319 | } |
AzureIoTClient | 8:418a3b812584 | 1320 | else if (strcmp(OPTION_KEEP_ALIVE, option) == 0) |
AzureIoTClient | 4:e472f5ce3473 | 1321 | { |
AzureIoTClient | 4:e472f5ce3473 | 1322 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_036: [If the option parameter is set to "keepalive" then the value shall be a int_ptr and the value will determine the mqtt keepalive time that is set for pings.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1323 | int* keepAliveOption = (int*)value; |
AzureIoTClient | 4:e472f5ce3473 | 1324 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_037 : [If the option parameter is set to supplied int_ptr keepalive is the same value as the existing keepalive then IoTHubTransportMqtt_SetOption shall do nothing.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1325 | if (*keepAliveOption != transportState->keepAliveValue) |
AzureIoTClient | 4:e472f5ce3473 | 1326 | { |
AzureIoTClient | 6:16875b609849 | 1327 | transportState->keepAliveValue = (uint16_t)(*keepAliveOption); |
AzureIoTClient | 4:e472f5ce3473 | 1328 | if (transportState->connected) |
AzureIoTClient | 4:e472f5ce3473 | 1329 | { |
AzureIoTClient | 4:e472f5ce3473 | 1330 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_038: [If the client is connected when the keepalive is set then IoTHubTransportMqtt_SetOption shall disconnect and reconnect with the specified keepalive value.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1331 | DisconnectFromClient(transportState); |
AzureIoTClient | 4:e472f5ce3473 | 1332 | } |
AzureIoTClient | 4:e472f5ce3473 | 1333 | } |
AzureIoTClient | 4:e472f5ce3473 | 1334 | result = IOTHUB_CLIENT_OK; |
AzureIoTClient | 4:e472f5ce3473 | 1335 | } |
AzureIoTClient | 7:7fdd306e6224 | 1336 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_039: [If the option parameter is set to "x509certificate" then the value shall be a const char of the certificate to be used for x509.] */ |
AzureIoTClient | 8:418a3b812584 | 1337 | else if ((strcmp(OPTION_X509_CERT, option) == 0) && (transportState->transport_creds.credential_type != X509)) |
AzureIoTClient | 7:7fdd306e6224 | 1338 | { |
AzureIoTClient | 7:7fdd306e6224 | 1339 | LogError("x509certificate specified, but authentication method is not x509"); |
AzureIoTClient | 7:7fdd306e6224 | 1340 | result = IOTHUB_CLIENT_INVALID_ARG; |
AzureIoTClient | 7:7fdd306e6224 | 1341 | } |
AzureIoTClient | 7:7fdd306e6224 | 1342 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_040: [If the option parameter is set to "x509privatekey" then the value shall be a const char of the RSA Private Key to be used for x509.] */ |
AzureIoTClient | 8:418a3b812584 | 1343 | else if ((strcmp(OPTION_X509_PRIVATE_KEY, option) == 0) && (transportState->transport_creds.credential_type != X509)) |
AzureIoTClient | 7:7fdd306e6224 | 1344 | { |
AzureIoTClient | 7:7fdd306e6224 | 1345 | LogError("x509privatekey specified, but authentication method is not x509"); |
AzureIoTClient | 7:7fdd306e6224 | 1346 | result = IOTHUB_CLIENT_INVALID_ARG; |
AzureIoTClient | 7:7fdd306e6224 | 1347 | } |
AzureIoTClient | 4:e472f5ce3473 | 1348 | else |
AzureIoTClient | 4:e472f5ce3473 | 1349 | { |
AzureIoTClient | 4:e472f5ce3473 | 1350 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_032: [IoTHubTransportMqtt_SetOption shall pass down the option to xio_setoption if the option parameter is not a known option string for the MQTT transport.] */ |
AzureIoTClient | 4:e472f5ce3473 | 1351 | if (GetTransportProviderIfNecessary(transportState) == 0) |
AzureIoTClient | 4:e472f5ce3473 | 1352 | { |
AzureIoTClient | 4:e472f5ce3473 | 1353 | if (xio_setoption(transportState->xioTransport, option, value) == 0) |
AzureIoTClient | 4:e472f5ce3473 | 1354 | { |
AzureIoTClient | 4:e472f5ce3473 | 1355 | result = IOTHUB_CLIENT_OK; |
AzureIoTClient | 4:e472f5ce3473 | 1356 | } |
AzureIoTClient | 4:e472f5ce3473 | 1357 | else |
AzureIoTClient | 4:e472f5ce3473 | 1358 | { |
AzureIoTClient | 4:e472f5ce3473 | 1359 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_132: [IoTHubTransportMqtt_SetOption shall return IOTHUB_CLIENT_INVALID_ARG xio_setoption fails] */ |
AzureIoTClient | 4:e472f5ce3473 | 1360 | result = IOTHUB_CLIENT_INVALID_ARG; |
AzureIoTClient | 4:e472f5ce3473 | 1361 | } |
AzureIoTClient | 4:e472f5ce3473 | 1362 | } |
AzureIoTClient | 4:e472f5ce3473 | 1363 | else |
AzureIoTClient | 4:e472f5ce3473 | 1364 | { |
AzureIoTClient | 4:e472f5ce3473 | 1365 | result = IOTHUB_CLIENT_ERROR; |
AzureIoTClient | 4:e472f5ce3473 | 1366 | } |
AzureIoTClient | 4:e472f5ce3473 | 1367 | } |
AzureIoTClient | 4:e472f5ce3473 | 1368 | } |
AzureIoTClient | 4:e472f5ce3473 | 1369 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 1370 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1371 | |
AzureIoTClient | 4:e472f5ce3473 | 1372 | static IOTHUB_DEVICE_HANDLE IoTHubTransportMqtt_Register(TRANSPORT_LL_HANDLE handle, const IOTHUB_DEVICE_CONFIG* device, IOTHUB_CLIENT_LL_HANDLE iotHubClientHandle, PDLIST_ENTRY waitingToSend) |
Azure.IoT Build | 0:5e72a75c31b8 | 1373 | { |
AzureIoTClient | 7:7fdd306e6224 | 1374 | IOTHUB_DEVICE_HANDLE result = NULL; |
AzureIoTClient | 6:16875b609849 | 1375 | (void)iotHubClientHandle; |
AzureIoTClient | 6:16875b609849 | 1376 | |
AzureIoTClient | 4:e472f5ce3473 | 1377 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_17_001: [ IoTHubTransportMqtt_Register shall return NULL if the TRANSPORT_LL_HANDLE is NULL.] |
AzureIoTClient | 4:e472f5ce3473 | 1378 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_17_002: [ IoTHubTransportMqtt_Register shall return NULL if device or waitingToSend are NULL.] |
AzureIoTClient | 4:e472f5ce3473 | 1379 | if ((handle == NULL) || (device == NULL) || (waitingToSend == NULL)) |
AzureIoTClient | 4:e472f5ce3473 | 1380 | { |
AzureIoTClient | 3:40f482ed0be8 | 1381 | LogError("IoTHubTransportMqtt_Register: handle, device or waitingToSend is NULL."); |
Azure.IoT Build | 0:5e72a75c31b8 | 1382 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1383 | } |
AzureIoTClient | 4:e472f5ce3473 | 1384 | else |
AzureIoTClient | 4:e472f5ce3473 | 1385 | { |
AzureIoTClient | 4:e472f5ce3473 | 1386 | MQTTTRANSPORT_HANDLE_DATA* transportState = (MQTTTRANSPORT_HANDLE_DATA*)handle; |
Azure.IoT Build | 0:5e72a75c31b8 | 1387 | |
AzureIoTClient | 4:e472f5ce3473 | 1388 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_03_001: [ IoTHubTransportMqtt_Register shall return NULL if deviceId, or both deviceKey and deviceSasToken are NULL.] |
AzureIoTClient | 4:e472f5ce3473 | 1389 | if (device->deviceId == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1390 | { |
AzureIoTClient | 3:40f482ed0be8 | 1391 | LogError("IoTHubTransportMqtt_Register: deviceId is NULL."); |
AzureIoTClient | 3:40f482ed0be8 | 1392 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1393 | } |
AzureIoTClient | 4:e472f5ce3473 | 1394 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_03_002: [ IoTHubTransportMqtt_Register shall return NULL if both deviceKey and deviceSasToken are provided.] |
AzureIoTClient | 4:e472f5ce3473 | 1395 | else if ((device->deviceKey != NULL) && (device->deviceSasToken != NULL)) |
AzureIoTClient | 4:e472f5ce3473 | 1396 | { |
AzureIoTClient | 3:40f482ed0be8 | 1397 | LogError("IoTHubTransportMqtt_Register: Both deviceKey and deviceSasToken are defined. Only one can be used."); |
Azure.IoT Build | 0:5e72a75c31b8 | 1398 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1399 | } |
AzureIoTClient | 4:e472f5ce3473 | 1400 | else |
AzureIoTClient | 4:e472f5ce3473 | 1401 | { |
AzureIoTClient | 4:e472f5ce3473 | 1402 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_17_003: [ IoTHubTransportMqtt_Register shall return NULL if deviceId or deviceKey do not match the deviceId and deviceKey passed in during IoTHubTransportMqtt_Create.] |
AzureIoTClient | 4:e472f5ce3473 | 1403 | if (strcmp(STRING_c_str(transportState->device_id), device->deviceId) != 0) |
AzureIoTClient | 4:e472f5ce3473 | 1404 | { |
AzureIoTClient | 3:40f482ed0be8 | 1405 | LogError("IoTHubTransportMqtt_Register: deviceId does not match."); |
AzureIoTClient | 3:40f482ed0be8 | 1406 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1407 | } |
AzureIoTClient | 7:7fdd306e6224 | 1408 | else if ( (transportState->transport_creds.credential_type == DEVICE_KEY) && (strcmp(STRING_c_str(transportState->transport_creds.CREDENTIAL_VALUE.deviceKey), device->deviceKey) != 0)) |
AzureIoTClient | 4:e472f5ce3473 | 1409 | { |
AzureIoTClient | 3:40f482ed0be8 | 1410 | LogError("IoTHubTransportMqtt_Register: deviceKey does not match."); |
Azure.IoT Build | 0:5e72a75c31b8 | 1411 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1412 | } |
AzureIoTClient | 4:e472f5ce3473 | 1413 | else |
AzureIoTClient | 4:e472f5ce3473 | 1414 | { |
AzureIoTClient | 4:e472f5ce3473 | 1415 | if (transportState->isRegistered == true) |
AzureIoTClient | 4:e472f5ce3473 | 1416 | { |
AzureIoTClient | 4:e472f5ce3473 | 1417 | LogError("Transport already has device registered by id: [%s]", device->deviceId); |
AzureIoTClient | 4:e472f5ce3473 | 1418 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1419 | } |
AzureIoTClient | 4:e472f5ce3473 | 1420 | else |
AzureIoTClient | 4:e472f5ce3473 | 1421 | { |
AzureIoTClient | 4:e472f5ce3473 | 1422 | transportState->isRegistered = true; |
AzureIoTClient | 4:e472f5ce3473 | 1423 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_17_004: [ IoTHubTransportMqtt_Register shall return the TRANSPORT_LL_HANDLE as the IOTHUB_DEVICE_HANDLE. ] |
AzureIoTClient | 4:e472f5ce3473 | 1424 | result = (IOTHUB_DEVICE_HANDLE)handle; |
AzureIoTClient | 4:e472f5ce3473 | 1425 | } |
AzureIoTClient | 4:e472f5ce3473 | 1426 | } |
AzureIoTClient | 4:e472f5ce3473 | 1427 | } |
AzureIoTClient | 4:e472f5ce3473 | 1428 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1429 | |
AzureIoTClient | 4:e472f5ce3473 | 1430 | return result; |
Azure.IoT Build | 0:5e72a75c31b8 | 1431 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1432 | |
Azure.IoT Build | 0:5e72a75c31b8 | 1433 | // Codes_SRS_IOTHUB_MQTT_TRANSPORT_17_005: [ IoTHubTransportMqtt_Unregister shall return. ] |
AzureIoTClient | 4:e472f5ce3473 | 1434 | static void IoTHubTransportMqtt_Unregister(IOTHUB_DEVICE_HANDLE deviceHandle) |
Azure.IoT Build | 0:5e72a75c31b8 | 1435 | { |
AzureIoTClient | 4:e472f5ce3473 | 1436 | if (deviceHandle != NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1437 | { |
AzureIoTClient | 4:e472f5ce3473 | 1438 | MQTTTRANSPORT_HANDLE_DATA* transportState = (MQTTTRANSPORT_HANDLE_DATA*)deviceHandle; |
Azure.IoT Build | 0:5e72a75c31b8 | 1439 | |
AzureIoTClient | 4:e472f5ce3473 | 1440 | transportState->isRegistered = false; |
AzureIoTClient | 4:e472f5ce3473 | 1441 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1442 | } |
Azure.IoT Build | 0:5e72a75c31b8 | 1443 | |
AzureIoTClient | 4:e472f5ce3473 | 1444 | static STRING_HANDLE IoTHubTransportMqtt_GetHostname(TRANSPORT_LL_HANDLE handle) |
AzureIoTClient | 4:e472f5ce3473 | 1445 | { |
AzureIoTClient | 4:e472f5ce3473 | 1446 | STRING_HANDLE result; |
AzureIoTClient | 4:e472f5ce3473 | 1447 | /*Codes_SRS_IOTHUB_MQTT_TRANSPORT_02_001: [ If handle is NULL then IoTHubTransportMqtt_GetHostname shall fail and return NULL. ]*/ |
AzureIoTClient | 4:e472f5ce3473 | 1448 | if (handle == NULL) |
AzureIoTClient | 4:e472f5ce3473 | 1449 | { |
AzureIoTClient | 4:e472f5ce3473 | 1450 | result = NULL; |
AzureIoTClient | 4:e472f5ce3473 | 1451 | } |
AzureIoTClient | 4:e472f5ce3473 | 1452 | else |
AzureIoTClient | 4:e472f5ce3473 | 1453 | { |
AzureIoTClient | 4:e472f5ce3473 | 1454 | /*Codes_SRS_IOTHUB_MQTT_TRANSPORT_02_002: [ Otherwise IoTHubTransportMqtt_GetHostname shall return a non-NULL STRING_HANDLE containg the hostname. ]*/ |
AzureIoTClient | 4:e472f5ce3473 | 1455 | result = ((MQTTTRANSPORT_HANDLE_DATA*)handle)->hostAddress; |
AzureIoTClient | 4:e472f5ce3473 | 1456 | } |
AzureIoTClient | 4:e472f5ce3473 | 1457 | return result; |
AzureIoTClient | 4:e472f5ce3473 | 1458 | } |
AzureIoTClient | 4:e472f5ce3473 | 1459 | |
AzureIoTClient | 4:e472f5ce3473 | 1460 | static TRANSPORT_PROVIDER myfunc = { |
AzureIoTClient | 4:e472f5ce3473 | 1461 | IoTHubTransportMqtt_GetHostname, |
AzureIoTClient | 4:e472f5ce3473 | 1462 | IoTHubTransportMqtt_SetOption, |
AzureIoTClient | 4:e472f5ce3473 | 1463 | IoTHubTransportMqtt_Create, |
AzureIoTClient | 4:e472f5ce3473 | 1464 | IoTHubTransportMqtt_Destroy, |
AzureIoTClient | 4:e472f5ce3473 | 1465 | IoTHubTransportMqtt_Register, |
AzureIoTClient | 4:e472f5ce3473 | 1466 | IoTHubTransportMqtt_Unregister, |
AzureIoTClient | 4:e472f5ce3473 | 1467 | IoTHubTransportMqtt_Subscribe, |
AzureIoTClient | 4:e472f5ce3473 | 1468 | IoTHubTransportMqtt_Unsubscribe, |
AzureIoTClient | 4:e472f5ce3473 | 1469 | IoTHubTransportMqtt_DoWork, |
AzureIoTClient | 4:e472f5ce3473 | 1470 | IoTHubTransportMqtt_GetSendStatus |
Azure.IoT Build | 0:5e72a75c31b8 | 1471 | }; |
Azure.IoT Build | 0:5e72a75c31b8 | 1472 | |
Azure.IoT Build | 0:5e72a75c31b8 | 1473 | /* Codes_SRS_IOTHUB_MQTT_TRANSPORT_07_022: [This function shall return a pointer to a structure of type TRANSPORT_PROVIDER having the following values for its fields: IoTHubTransport_Create = IoTHubTransportMqtt_Create |
Azure.IoT Build | 0:5e72a75c31b8 | 1474 | IoTHubTransport_Destroy = IoTHubTransportMqtt_Destroy |
Azure.IoT Build | 0:5e72a75c31b8 | 1475 | IoTHubTransport_Subscribe = IoTHubTransportMqtt_Subscribe |
Azure.IoT Build | 0:5e72a75c31b8 | 1476 | IoTHubTransport_Unsubscribe = IoTHubTransportMqtt_Unsubscribe |
Azure.IoT Build | 0:5e72a75c31b8 | 1477 | IoTHubTransport_DoWork = IoTHubTransportMqtt_DoWork |
Azure.IoT Build | 0:5e72a75c31b8 | 1478 | IoTHubTransport_SetOption = IoTHubTransportMqtt_SetOption] */ |
AzureIoTClient | 4:e472f5ce3473 | 1479 | extern const TRANSPORT_PROVIDER* MQTT_Protocol(void) |
Azure.IoT Build | 0:5e72a75c31b8 | 1480 | { |
AzureIoTClient | 4:e472f5ce3473 | 1481 | return &myfunc; |
Azure.IoT Build | 0:5e72a75c31b8 | 1482 | } |