Software to drive a monitor unit for a closed circuit rebreather using 3 electrogalvanic oxygen sensor cells run through an amplifier (lm324) . Uses a separate ds1307 clock IC to get timestamp values for logged data.

Dependencies:   DS1307 TextOLED_custom mbed

Homepage

The main electornics is housed in another pod mounted on the back of the unit. I'm using an mbed lpc11u24 to drive everything which comes with a flash drive for data logging built in. It has an external ds1307 clock chip added and a very cheapo lm324 quad op-amp to amplify the o2 sensor signals from the 10s of mV range by 30x so that ppo2=0.21 corresponds to about 0.3V. I still have to do some ADC averaging with this amplifier and do have to calibrate out the individual offsets of the chip but this works ok now that I've worked out which amp is on which adc...


All wikipages