Central Heating controller using the real time clock, PHY module for internet, 1-wire interface for temperature sensors, a system log and a configuration file
Dependencies: net 1-wire lpc1768 crypto clock web fram log
/media/uploads/andrewboyson/heating.sch
/media/uploads/andrewboyson/heating.brd
/media/uploads/andrewboyson/eagle.epf
Diff: web-this/boiler/web-boiler-html.c
- Revision:
- 105:1899f7ed17ec
- Parent:
- 104:46ce1aaf8be7
- Child:
- 106:41ed3ea0bbba
diff -r 46ce1aaf8be7 -r 1899f7ed17ec web-this/boiler/web-boiler-html.c --- a/web-this/boiler/web-boiler-html.c Wed Feb 10 17:24:36 2021 +0000 +++ b/web-this/boiler/web-boiler-html.c Tue Feb 23 20:35:07 2021 +0000 @@ -21,25 +21,30 @@ WebAddH2("Pump outputs"); WebAddAjaxLed("Boiler pump", "ajax-blr-pump-toggle"); - WebAddAjaxLabelledSuffix("Boiler pump speed (0-100)", "ajax-blr-pump-speed-html", "%"); + WebAddAjaxLabelledSuffix("Boiler pump speed (10-100)", "ajax-blr-pump-speed-html", "%"); WebAddAjaxLabelledSuffix("Boiler pump pwm (84-10)", "ajax-blr-pump-pwm-html" , "%"); WebAddH2("Pump inputs"); - WebAddAjaxLabelledSuffix("Boiler output", "ajax-blr-out-html", "°C"); - WebAddAjaxLabelledSuffix("Boiler input", "ajax-blr-rtn-html", "°C"); - WebAddAjaxLabelledSuffix("Boiler ΔT", "ajax-blr-rise-html", "°C"); + WebAddAjaxLabelledSuffix("Boiler output", "ajax-blr-out-html", "°C"); + WebAddAjaxLabelledSuffix("Boiler input", "ajax-blr-rtn-html", "°C"); + WebAddAjaxLabelledSuffix("Boiler input aligned", "ajax-blr-aln-html", "°C"); + WebAddAjaxLabelledSuffix("Boiler ΔT", "ajax-blr-rise-html", "°C"); - WebAddH2("Pump calling parameters"); - WebAddAjaxInput("Pump speed calling (% or -1)",2, "ajax-pump-speed-calling", "pumpspeedcalling" ); - WebAddAjaxInput("Boiler output target (deg)", 2, "ajax-blr-output-target", "boileroutputtarget"); - WebAddAjaxInput("Boiler ΔT at pump 0", 3, "ajax-pump-rise-at-0" , "blrriseat0" ); - WebAddAjaxInput("Boiler ΔT at pump 50", 3, "ajax-pump-rise-at-50" , "blrriseat50" ); - WebAddAjaxInput("Boiler ΔT at pump 100", 3, "ajax-pump-rise-at-100" , "blrriseat100" ); + WebAddH2("Pump parameters"); + WebAddAjaxInput("Full speed circuit time (sec)" , 2, "ajax-full-speed-secs" , "fullspeedsecs" ); + + WebAddH2("Pump parameters during boiler call"); + WebAddAjaxInputToggle("Boiler call enable", "ajax-blr-enable-toggle", "boilercallenable"); + WebAddAjaxInput("Calling pump speed (%, A or T)", 2, "ajax-pump-speed-calling", "pumpspeedcalling" ); + WebAddAjaxInput("Boiler output target (deg)" , 2, "ajax-blr-output-target" , "boileroutputtarget"); + WebAddAjaxInput("Minimum flow (%)" , 3, "ajax-pump-rise-at-0" , "blrriseat0" ); + WebAddAjaxInput("Mid flow speed" , 3, "ajax-pump-rise-at-50" , "blrriseat50" ); + WebAddAjaxInput("Full speed ΔT" , 3, "ajax-pump-rise-at-100" , "blrriseat100" ); - WebAddH2("Pump run on parameters"); - WebAddAjaxInput("Run on residual heat (deg)", 2, "ajax-blr-run-on-deg", "boilerresidual" ); - WebAddAjaxInput("Run on max time (sec)", 2, "ajax-blr-run-on-time", "boilerrunon" ); - WebAddAjaxInput("Run on pump speed (%)", 2, "ajax-pump-speed-run-on", "pumpspeedrunon" ); + WebAddH2("Pump parameters during run on"); + WebAddAjaxInput("Run on min ΔT" , 2, "ajax-blr-run-on-deg", "boilerresidual" ); + WebAddAjaxInput("Run on max time (sec)" , 2, "ajax-blr-run-on-time", "boilerrunon" ); + WebAddAjaxInput("Run on pump speed (%)" , 2, "ajax-pump-speed-run-on", "pumpspeedrunon" ); WebAddEnd();