Central Heating controller using the real time clock, PHY module for internet, 1-wire interface for temperature sensors, a system log and a configuration file

Dependencies:   net 1-wire lpc1768 crypto clock web fram log

/media/uploads/andrewboyson/heating.sch

/media/uploads/andrewboyson/heating.brd

/media/uploads/andrewboyson/eagle.epf

web-this/boiler/web-boiler-ajax.c

Committer:
andrewboyson
Date:
2020-06-10
Revision:
91:8b192efd0288
Parent:
53:c1bf7d9db507
Child:
104:46ce1aaf8be7

File content as of revision 91:8b192efd0288:

#include  <stdint.h>
#include   <stdio.h>

#include "http.h"
#include "boiler.h"
#include "radiator.h"
#include "ds18b20.h"
#include "program.h"
#include "1-wire-device.h"

void WebBoilerAjax()
{
    HttpOk("text/plain; charset=UTF-8", "no-cache", NULL, NULL);

    HttpAddInt16AsHex(BoilerGetTankDS18B20Value()  ); HttpAddChar('\n');
    HttpAddInt16AsHex(BoilerGetOutputDS18B20Value()); HttpAddChar('\n');
    HttpAddInt16AsHex(BoilerGetReturnDS18B20Value()); HttpAddChar('\n');
    
    int nibble = 0;
    if (BoilerCall           ) nibble |= 1;
    if (BoilerPump           ) nibble |= 2;
    HttpAddNibbleAsHex (nibble); HttpAddChar('\n');
    
    HttpAddInt16AsHex(BoilerGetTankSetPoint      ()); HttpAddChar('\n');
    HttpAddInt16AsHex(BoilerGetTankHysteresis    ()); HttpAddChar('\n');
    HttpAddInt16AsHex(BoilerGetRunOnResidual16ths()); HttpAddChar('\n');
    HttpAddInt16AsHex(BoilerGetRunOnTime         ()); HttpAddChar('\n');

    
}