+"$-Code"," Setting"," Units"," Setting Description"
+"0","Step pulse time","microseconds","Sets time length per step. Minimum 3usec."
+"1","Step idle delay","milliseconds","Sets a short hold delay when stopping to let dynamics settle before disabling steppers. Value 255 keeps motors enabled with no delay."
+"2","Step pulse invert","mask","Inverts the step signal. Set axis bit to invert (00000ZYX)."
+"3","Step direction invert","mask","Inverts the direction signal. Set axis bit to invert (00000ZYX)."
+"4","Invert step enable pin","boolean","Inverts the stepper driver enable pin signal."
+"5","Invert limit pins","boolean","Inverts the all of the limit input pins."
+"6","Invert probe pin","boolean","Inverts the probe input pin signal."
+"10","Status report options","mask","Alters data included in status reports."
+"11","Junction deviation","millimeters","Sets how fast Grbl travels through consecutive motions. Lower value slows it down."
+"12","Arc tolerance","millimeters","Sets the G2 and G3 arc tracing accuracy based on radial error. Beware: A very small value may effect performance."
+"13","Report in inches","boolean","Enables inch units when returning any position and rate value that is not a settings value."
+"20","Soft limits enable","boolean","Enables soft limits checks within machine travel and sets alarm when exceeded. Requires homing."
+"21","Hard limits enable","boolean","Enables hard limits. Immediately halts motion and throws an alarm when switch is triggered."
+"22","Homing cycle enable","boolean","Enables homing cycle. Requires limit switches on all axes."
+"23","Homing direction invert","mask","Homing searches for a switch in the positive direction. Set axis bit (00000ZYX) to search in negative direction."
+"24","Homing locate feed rate","mm/min","Feed rate to slowly engage limit switch to determine its location accurately."
+"25","Homing search seek rate","mm/min","Seek rate to quickly find the limit switch before the slower locating phase."
+"26","Homing switch debounce delay","milliseconds","Sets a short delay between phases of homing cycle to let a switch debounce."
+"27","Homing switch pull-off distance","millimeters","Retract distance after triggering switch to disengage it. Homing will fail if switch isn't cleared."
+"30","Maximum spindle speed","RPM","Maximum spindle speed. Sets PWM to 100% duty cycle."
+"31","Minimum spindle speed","RPM","Minimum spindle speed. Sets PWM to 0.4% or lowest duty cycle."
+"32","Laser-mode enable","boolean","Enables laser mode. Consecutive G1/2/3 commands will not halt when spindle speed is changed."
+"100","X-axis travel resolution","step/mm","X-axis travel resolution in steps per millimeter."
+"101","Y-axis travel resolution","step/mm","Y-axis travel resolution in steps per millimeter."
+"102","Z-axis travel resolution","step/mm","Z-axis travel resolution in steps per millimeter."
+"110","X-axis maximum rate","mm/min","X-axis maximum rate. Used as G0 rapid rate."
+"111","Y-axis maximum rate","mm/min","Y-axis maximum rate. Used as G0 rapid rate."
+"112","Z-axis maximum rate","mm/min","Z-axis maximum rate. Used as G0 rapid rate."
+"120","X-axis acceleration","mm/sec^2","X-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
+"121","Y-axis acceleration","mm/sec^2","Y-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
+"122","Z-axis acceleration","mm/sec^2","Z-axis acceleration. Used for motion planning to not exceed motor torque and lose steps."
+"130","X-axis maximum travel","millimeters","Maximum X-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
+"131","Y-axis maximum travel","millimeters","Maximum Y-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."
+"132","Z-axis maximum travel","millimeters","Maximum Z-axis travel distance from homing switch. Determines valid machine space for soft-limits and homing search distances."