Revision:
0:8f0d870509fe
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/doc/csv/alarm_codes_en_US.csv	Mon Sep 04 12:04:13 2017 +0000
@@ -0,0 +1,10 @@
+"Alarm Code in v1.1+"," Alarm Message in v1.0-"," Alarm Description"
+"1","Hard limit","Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
+"2","Soft limit","Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked."
+"3","Abort during cycle","Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
+"4","Probe fail","Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered."
+"5","Probe fail","Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4."
+"6","Homing fail","Homing fail. The active homing cycle was reset."
+"7","Homing fail","Homing fail. Safety door was opened during homing cycle."
+"8","Homing fail","Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring."
+"9","Homing fail","Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring."