Sergunb 0:8f0d870509fe 1 "Alarm Code in v1.1+"," Alarm Message in v1.0-"," Alarm Description"
Sergunb 0:8f0d870509fe 2 "1","Hard limit","Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
Sergunb 0:8f0d870509fe 3 "2","Soft limit","Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked."
Sergunb 0:8f0d870509fe 4 "3","Abort during cycle","Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended."
Sergunb 0:8f0d870509fe 5 "4","Probe fail","Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered."
Sergunb 0:8f0d870509fe 6 "5","Probe fail","Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4."
Sergunb 0:8f0d870509fe 7 "6","Homing fail","Homing fail. The active homing cycle was reset."
Sergunb 0:8f0d870509fe 8 "7","Homing fail","Homing fail. Safety door was opened during homing cycle."
Sergunb 0:8f0d870509fe 9 "8","Homing fail","Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring."
Sergunb 0:8f0d870509fe 10 "9","Homing fail","Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring."