doc/csv/alarm_codes_en_US.csv@0:8f0d870509fe, 2017-09-04 (annotated)
- Committer:
- Sergunb
- Date:
- Mon Sep 04 12:04:13 2017 +0000
- Revision:
- 0:8f0d870509fe
Initial commit
Who changed what in which revision?
User | Revision | Line number | New contents of line |
---|---|---|---|
Sergunb | 0:8f0d870509fe | 1 | "Alarm Code in v1.1+"," Alarm Message in v1.0-"," Alarm Description" |
Sergunb | 0:8f0d870509fe | 2 | "1","Hard limit","Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended." |
Sergunb | 0:8f0d870509fe | 3 | "2","Soft limit","Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked." |
Sergunb | 0:8f0d870509fe | 4 | "3","Abort during cycle","Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended." |
Sergunb | 0:8f0d870509fe | 5 | "4","Probe fail","Probe fail. Probe is not in the expected initial state before starting probe cycle when G38.2 and G38.3 is not triggered and G38.4 and G38.5 is triggered." |
Sergunb | 0:8f0d870509fe | 6 | "5","Probe fail","Probe fail. Probe did not contact the workpiece within the programmed travel for G38.2 and G38.4." |
Sergunb | 0:8f0d870509fe | 7 | "6","Homing fail","Homing fail. The active homing cycle was reset." |
Sergunb | 0:8f0d870509fe | 8 | "7","Homing fail","Homing fail. Safety door was opened during homing cycle." |
Sergunb | 0:8f0d870509fe | 9 | "8","Homing fail","Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring." |
Sergunb | 0:8f0d870509fe | 10 | "9","Homing fail","Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring." |