A small memory footprint AMQP implimentation
Dependents: iothub_client_sample_amqp remote_monitoring simplesample_amqp
amqp_management.c@41:0e723f9cbd89, 2018-03-20 (annotated)
- Committer:
- AzureIoTClient
- Date:
- Tue Mar 20 10:29:38 2018 -0700
- Revision:
- 41:0e723f9cbd89
- Parent:
- 40:f0ceafa8d570
- Child:
- 43:4c1e4e94cdd3
1.2.1
Who changed what in which revision?
User | Revision | Line number | New contents of line |
---|---|---|---|
Azure.IoT Build | 0:6ae2f7bca550 | 1 | // Copyright (c) Microsoft. All rights reserved. |
Azure.IoT Build | 0:6ae2f7bca550 | 2 | // Licensed under the MIT license. See LICENSE file in the project root for full license information. |
Azure.IoT Build | 0:6ae2f7bca550 | 3 | |
Azure.IoT Build | 0:6ae2f7bca550 | 4 | #include <stdlib.h> |
Azure.IoT Build | 0:6ae2f7bca550 | 5 | #include <stdio.h> |
AzureIoTClient | 6:641a9672db08 | 6 | #include <stdbool.h> |
Azure.IoT Build | 0:6ae2f7bca550 | 7 | #include <string.h> |
AzureIoTClient | 19:000ab4e6a2c1 | 8 | #include "azure_c_shared_utility/optimize_size.h" |
AzureIoTClient | 21:f9c433d8e6ca | 9 | #include "azure_c_shared_utility/gballoc.h" |
AzureIoTClient | 23:1111ee8bcba4 | 10 | #include "azure_c_shared_utility/singlylinkedlist.h" |
AzureIoTClient | 27:d74f1cea23e1 | 11 | #include "azure_c_shared_utility/xlogging.h" |
AzureIoTClient | 39:e7c983378f41 | 12 | #include "azure_c_shared_utility/crt_abstractions.h" |
Azure.IoT Build | 0:6ae2f7bca550 | 13 | #include "azure_uamqp_c/amqp_management.h" |
Azure.IoT Build | 0:6ae2f7bca550 | 14 | #include "azure_uamqp_c/link.h" |
Azure.IoT Build | 0:6ae2f7bca550 | 15 | #include "azure_uamqp_c/message_sender.h" |
Azure.IoT Build | 0:6ae2f7bca550 | 16 | #include "azure_uamqp_c/message_receiver.h" |
Azure.IoT Build | 0:6ae2f7bca550 | 17 | #include "azure_uamqp_c/messaging.h" |
AzureIoTClient | 40:f0ceafa8d570 | 18 | #include "azure_uamqp_c/amqp_definitions.h" |
Azure.IoT Build | 0:6ae2f7bca550 | 19 | |
AzureIoTClient | 23:1111ee8bcba4 | 20 | static const char sender_suffix[] = "-sender"; |
AzureIoTClient | 23:1111ee8bcba4 | 21 | static const char receiver_suffix[] = "-receiver"; |
AzureIoTClient | 23:1111ee8bcba4 | 22 | |
AzureIoTClient | 23:1111ee8bcba4 | 23 | #define COUNT_CHARS(str) (sizeof(str) / sizeof((str)[0]) - 1) |
Azure.IoT Build | 0:6ae2f7bca550 | 24 | |
Azure.IoT Build | 0:6ae2f7bca550 | 25 | typedef struct OPERATION_MESSAGE_INSTANCE_TAG |
Azure.IoT Build | 0:6ae2f7bca550 | 26 | { |
AzureIoTClient | 22:524bded3f7a8 | 27 | ON_AMQP_MANAGEMENT_EXECUTE_OPERATION_COMPLETE on_execute_operation_complete; |
AzureIoTClient | 6:641a9672db08 | 28 | void* callback_context; |
AzureIoTClient | 23:1111ee8bcba4 | 29 | uint64_t message_id; |
AzureIoTClient | 41:0e723f9cbd89 | 30 | AMQP_MANAGEMENT_HANDLE amqp_management; |
Azure.IoT Build | 0:6ae2f7bca550 | 31 | } OPERATION_MESSAGE_INSTANCE; |
Azure.IoT Build | 0:6ae2f7bca550 | 32 | |
AzureIoTClient | 22:524bded3f7a8 | 33 | typedef enum AMQP_MANAGEMENT_STATE_TAG |
AzureIoTClient | 22:524bded3f7a8 | 34 | { |
AzureIoTClient | 22:524bded3f7a8 | 35 | AMQP_MANAGEMENT_STATE_IDLE, |
AzureIoTClient | 22:524bded3f7a8 | 36 | AMQP_MANAGEMENT_STATE_OPENING, |
AzureIoTClient | 41:0e723f9cbd89 | 37 | AMQP_MANAGEMENT_STATE_CLOSING, |
AzureIoTClient | 22:524bded3f7a8 | 38 | AMQP_MANAGEMENT_STATE_OPEN, |
AzureIoTClient | 22:524bded3f7a8 | 39 | AMQP_MANAGEMENT_STATE_ERROR |
AzureIoTClient | 22:524bded3f7a8 | 40 | } AMQP_MANAGEMENT_STATE; |
AzureIoTClient | 22:524bded3f7a8 | 41 | |
Azure.IoT Build | 0:6ae2f7bca550 | 42 | typedef struct AMQP_MANAGEMENT_INSTANCE_TAG |
Azure.IoT Build | 0:6ae2f7bca550 | 43 | { |
AzureIoTClient | 6:641a9672db08 | 44 | LINK_HANDLE sender_link; |
AzureIoTClient | 6:641a9672db08 | 45 | LINK_HANDLE receiver_link; |
AzureIoTClient | 6:641a9672db08 | 46 | MESSAGE_SENDER_HANDLE message_sender; |
AzureIoTClient | 6:641a9672db08 | 47 | MESSAGE_RECEIVER_HANDLE message_receiver; |
AzureIoTClient | 23:1111ee8bcba4 | 48 | SINGLYLINKEDLIST_HANDLE pending_operations; |
AzureIoTClient | 23:1111ee8bcba4 | 49 | uint64_t next_message_id; |
AzureIoTClient | 22:524bded3f7a8 | 50 | ON_AMQP_MANAGEMENT_OPEN_COMPLETE on_amqp_management_open_complete; |
AzureIoTClient | 22:524bded3f7a8 | 51 | void* on_amqp_management_open_complete_context; |
AzureIoTClient | 22:524bded3f7a8 | 52 | ON_AMQP_MANAGEMENT_ERROR on_amqp_management_error; |
AzureIoTClient | 22:524bded3f7a8 | 53 | void* on_amqp_management_error_context; |
AzureIoTClient | 6:641a9672db08 | 54 | AMQP_MANAGEMENT_STATE amqp_management_state; |
AzureIoTClient | 39:e7c983378f41 | 55 | char* status_code_key_name; |
AzureIoTClient | 39:e7c983378f41 | 56 | char* status_description_key_name; |
AzureIoTClient | 6:641a9672db08 | 57 | int sender_connected : 1; |
AzureIoTClient | 6:641a9672db08 | 58 | int receiver_connected : 1; |
Azure.IoT Build | 0:6ae2f7bca550 | 59 | } AMQP_MANAGEMENT_INSTANCE; |
Azure.IoT Build | 0:6ae2f7bca550 | 60 | |
AzureIoTClient | 23:1111ee8bcba4 | 61 | static AMQP_VALUE on_message_received(const void* context, MESSAGE_HANDLE message) |
Azure.IoT Build | 0:6ae2f7bca550 | 62 | { |
AzureIoTClient | 23:1111ee8bcba4 | 63 | AMQP_VALUE result; |
Azure.IoT Build | 0:6ae2f7bca550 | 64 | |
AzureIoTClient | 23:1111ee8bcba4 | 65 | if (context == NULL) |
AzureIoTClient | 6:641a9672db08 | 66 | { |
AzureIoTClient | 23:1111ee8bcba4 | 67 | /* Codes_SRS_AMQP_MANAGEMENT_01_108: [ When `on_message_received` is called with a NULL context, it shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 68 | LogError("NULL context in on_message_received"); |
AzureIoTClient | 23:1111ee8bcba4 | 69 | result = NULL; |
AzureIoTClient | 6:641a9672db08 | 70 | } |
AzureIoTClient | 6:641a9672db08 | 71 | else |
AzureIoTClient | 6:641a9672db08 | 72 | { |
AzureIoTClient | 23:1111ee8bcba4 | 73 | AMQP_MANAGEMENT_HANDLE amqp_management = (AMQP_MANAGEMENT_HANDLE)context; |
AzureIoTClient | 23:1111ee8bcba4 | 74 | AMQP_VALUE application_properties; |
Azure.IoT Build | 0:6ae2f7bca550 | 75 | |
AzureIoTClient | 23:1111ee8bcba4 | 76 | /* Codes_SRS_AMQP_MANAGEMENT_01_109: [ `on_message_received` shall obtain the application properties from the message by calling `message_get_application_properties`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 77 | if (message_get_application_properties(message, &application_properties) != 0) |
AzureIoTClient | 6:641a9672db08 | 78 | { |
AzureIoTClient | 23:1111ee8bcba4 | 79 | /* Codes_SRS_AMQP_MANAGEMENT_01_113: [ If obtaining the application properties or message properties fails, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 80 | LogError("Could not retrieve application properties"); |
AzureIoTClient | 23:1111ee8bcba4 | 81 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 82 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 83 | result = messaging_delivery_rejected("amqp:internal-error", "Could not get application properties on AMQP management response."); |
AzureIoTClient | 6:641a9672db08 | 84 | } |
AzureIoTClient | 6:641a9672db08 | 85 | else |
AzureIoTClient | 6:641a9672db08 | 86 | { |
AzureIoTClient | 23:1111ee8bcba4 | 87 | PROPERTIES_HANDLE response_properties; |
Azure.IoT Build | 0:6ae2f7bca550 | 88 | |
AzureIoTClient | 23:1111ee8bcba4 | 89 | /* Codes_SRS_AMQP_MANAGEMENT_01_110: [ `on_message_received` shall obtain the message properties from the message by calling `message_get_properties`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 90 | if (message_get_properties(message, &response_properties) != 0) |
AzureIoTClient | 6:641a9672db08 | 91 | { |
AzureIoTClient | 23:1111ee8bcba4 | 92 | /* Codes_SRS_AMQP_MANAGEMENT_01_113: [ If obtaining the application properties or message properties fails, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 93 | LogError("Could not retrieve message properties"); |
AzureIoTClient | 23:1111ee8bcba4 | 94 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 95 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 96 | result = messaging_delivery_rejected("amqp:internal-error", "Could not get message properties on AMQP management response."); |
AzureIoTClient | 6:641a9672db08 | 97 | } |
AzureIoTClient | 6:641a9672db08 | 98 | else |
AzureIoTClient | 6:641a9672db08 | 99 | { |
AzureIoTClient | 23:1111ee8bcba4 | 100 | AMQP_VALUE key; |
AzureIoTClient | 23:1111ee8bcba4 | 101 | AMQP_VALUE value; |
AzureIoTClient | 23:1111ee8bcba4 | 102 | AMQP_VALUE desc_key; |
AzureIoTClient | 23:1111ee8bcba4 | 103 | AMQP_VALUE desc_value; |
AzureIoTClient | 23:1111ee8bcba4 | 104 | AMQP_VALUE map; |
AzureIoTClient | 23:1111ee8bcba4 | 105 | AMQP_VALUE correlation_id_value; |
AzureIoTClient | 23:1111ee8bcba4 | 106 | uint64_t correlation_id; |
AzureIoTClient | 23:1111ee8bcba4 | 107 | |
AzureIoTClient | 23:1111ee8bcba4 | 108 | /* Codes_SRS_AMQP_MANAGEMENT_01_111: [ `on_message_received` shall obtain the correlation Id from the message properties by using `properties_get_correlation_id`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 109 | if (properties_get_correlation_id(response_properties, &correlation_id_value) != 0) |
AzureIoTClient | 6:641a9672db08 | 110 | { |
AzureIoTClient | 23:1111ee8bcba4 | 111 | /* Codes_SRS_AMQP_MANAGEMENT_01_114: [ If obtaining the correlation Id fails, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ] */ |
AzureIoTClient | 23:1111ee8bcba4 | 112 | LogError("Could not retrieve correlation Id"); |
AzureIoTClient | 23:1111ee8bcba4 | 113 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 114 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 115 | result = messaging_delivery_rejected("amqp:internal-error", "Could not get correlation Id from AMQP management response."); |
AzureIoTClient | 6:641a9672db08 | 116 | } |
AzureIoTClient | 6:641a9672db08 | 117 | else |
AzureIoTClient | 6:641a9672db08 | 118 | { |
AzureIoTClient | 23:1111ee8bcba4 | 119 | if (amqpvalue_get_ulong(correlation_id_value, &correlation_id) != 0) |
AzureIoTClient | 6:641a9672db08 | 120 | { |
AzureIoTClient | 23:1111ee8bcba4 | 121 | /* Codes_SRS_AMQP_MANAGEMENT_01_132: [ If any functions manipulating AMQP values, application properties, etc., fail, an error shall be indicated to the consumer by calling the `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 122 | LogError("Could not retrieve correlation Id ulong value"); |
AzureIoTClient | 23:1111ee8bcba4 | 123 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 124 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 125 | result = messaging_delivery_rejected("amqp:internal-error", "Could not get correlation Id from AMQP management response."); |
AzureIoTClient | 6:641a9672db08 | 126 | } |
AzureIoTClient | 6:641a9672db08 | 127 | else |
AzureIoTClient | 6:641a9672db08 | 128 | { |
AzureIoTClient | 23:1111ee8bcba4 | 129 | /* Codes_SRS_AMQP_MANAGEMENT_01_119: [ `on_message_received` shall obtain the application properties map by calling `amqpvalue_get_inplace_described_value`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 130 | /* Codes_SRS_AMQP_MANAGEMENT_01_070: [ Response messages have the following application-properties: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 131 | map = amqpvalue_get_inplace_described_value(application_properties); |
AzureIoTClient | 23:1111ee8bcba4 | 132 | if (map == NULL) |
AzureIoTClient | 6:641a9672db08 | 133 | { |
AzureIoTClient | 23:1111ee8bcba4 | 134 | /* Codes_SRS_AMQP_MANAGEMENT_01_132: [ If any functions manipulating AMQP values, application properties, etc., fail, an error shall be indicated to the consumer by calling the `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 135 | LogError("Could not retrieve application property map"); |
AzureIoTClient | 23:1111ee8bcba4 | 136 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 137 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 138 | result = messaging_delivery_rejected("amqp:internal-error", "Could not get application property map from the application properties in the AMQP management response."); |
AzureIoTClient | 6:641a9672db08 | 139 | } |
AzureIoTClient | 6:641a9672db08 | 140 | else |
AzureIoTClient | 6:641a9672db08 | 141 | { |
AzureIoTClient | 39:e7c983378f41 | 142 | /* Codes_SRS_AMQP_MANAGEMENT_01_120: [ An AMQP value used to lookup the status code shall be created by calling `amqpvalue_create_string` with the status code key name (`statusCode`) as argument. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 143 | /* Codes_SRS_AMQP_MANAGEMENT_01_071: [ statusCode integer Yes HTTP response code [RFC2616] ]*/ |
AzureIoTClient | 39:e7c983378f41 | 144 | key = amqpvalue_create_string(amqp_management->status_code_key_name); |
AzureIoTClient | 23:1111ee8bcba4 | 145 | if (key == NULL) |
AzureIoTClient | 6:641a9672db08 | 146 | { |
AzureIoTClient | 23:1111ee8bcba4 | 147 | /* Codes_SRS_AMQP_MANAGEMENT_01_132: [ If any functions manipulating AMQP values, application properties, etc., fail, an error shall be indicated to the consumer by calling the `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 148 | LogError("Could not create status-code amqp value"); |
AzureIoTClient | 23:1111ee8bcba4 | 149 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 150 | /* Codes_SRS_AMQP_MANAGEMENT_01_135: [ When an error occurs in creating AMQP values (for status code, etc.) `on_message_received` shall call `messaging_delivery_released` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 151 | result = messaging_delivery_released(); |
AzureIoTClient | 6:641a9672db08 | 152 | } |
AzureIoTClient | 1:eab586236bfe | 153 | else |
AzureIoTClient | 1:eab586236bfe | 154 | { |
AzureIoTClient | 23:1111ee8bcba4 | 155 | /* Codes_SRS_AMQP_MANAGEMENT_01_121: [ The status code shall be looked up in the application properties by using `amqpvalue_get_map_value`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 156 | value = amqpvalue_get_map_value(map, key); |
AzureIoTClient | 23:1111ee8bcba4 | 157 | if (value == NULL) |
AzureIoTClient | 1:eab586236bfe | 158 | { |
AzureIoTClient | 23:1111ee8bcba4 | 159 | /* Codes_SRS_AMQP_MANAGEMENT_01_122: [ If status code is not found an error shall be indicated to the consumer by calling the `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 160 | LogError("Could not retrieve status code from application properties"); |
AzureIoTClient | 23:1111ee8bcba4 | 161 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 162 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 163 | result = messaging_delivery_rejected("amqp:internal-error", "Could not retrieve status code from the application properties in the AMQP management response."); |
AzureIoTClient | 1:eab586236bfe | 164 | } |
AzureIoTClient | 1:eab586236bfe | 165 | else |
AzureIoTClient | 1:eab586236bfe | 166 | { |
AzureIoTClient | 23:1111ee8bcba4 | 167 | int32_t status_code; |
AzureIoTClient | 23:1111ee8bcba4 | 168 | /* Codes_SRS_AMQP_MANAGEMENT_01_133: [ The status code value shall be extracted from the value found in the map by using `amqpvalue_get_int`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 169 | if (amqpvalue_get_int(value, &status_code) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 170 | { |
AzureIoTClient | 23:1111ee8bcba4 | 171 | /* Codes_SRS_AMQP_MANAGEMENT_01_132: [ If any functions manipulating AMQP values, application properties, etc., fail, an error shall be indicated to the consumer by calling the `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 172 | LogError("Could not retrieve status code int value"); |
AzureIoTClient | 23:1111ee8bcba4 | 173 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 174 | /* Codes_SRS_AMQP_MANAGEMENT_01_136: [ When `on_message_received` fails due to errors in parsing the response message `on_message_received` shall call `messaging_delivery_rejected` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 175 | result = messaging_delivery_rejected("amqp:internal-error", "Could not retrieve status code value from the application properties in the AMQP management response."); |
AzureIoTClient | 23:1111ee8bcba4 | 176 | } |
AzureIoTClient | 23:1111ee8bcba4 | 177 | else |
AzureIoTClient | 1:eab586236bfe | 178 | { |
AzureIoTClient | 39:e7c983378f41 | 179 | /* Codes_SRS_AMQP_MANAGEMENT_01_123: [ An AMQP value used to lookup the status description shall be created by calling `amqpvalue_create_string` with the status description key name (`statusDescription`) as argument. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 180 | /* Codes_SRS_AMQP_MANAGEMENT_01_072: [ statusDescription string No Description of the status. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 181 | desc_key = amqpvalue_create_string(amqp_management->status_description_key_name); |
AzureIoTClient | 23:1111ee8bcba4 | 182 | if (desc_key == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 183 | { |
AzureIoTClient | 23:1111ee8bcba4 | 184 | /* Codes_SRS_AMQP_MANAGEMENT_01_132: [ If any functions manipulating AMQP values, application properties, etc., fail, an error shall be indicated to the consumer by calling the `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 185 | LogError("Could not create status-description amqp value"); |
AzureIoTClient | 23:1111ee8bcba4 | 186 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 187 | /* Codes_SRS_AMQP_MANAGEMENT_01_135: [ When an error occurs in creating AMQP values (for status code, etc.) `on_message_received` shall call `messaging_delivery_released` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 188 | result = messaging_delivery_released(); |
AzureIoTClient | 23:1111ee8bcba4 | 189 | } |
AzureIoTClient | 23:1111ee8bcba4 | 190 | else |
AzureIoTClient | 23:1111ee8bcba4 | 191 | { |
AzureIoTClient | 23:1111ee8bcba4 | 192 | const char* status_description = NULL; |
AzureIoTClient | 23:1111ee8bcba4 | 193 | LIST_ITEM_HANDLE list_item_handle; |
AzureIoTClient | 23:1111ee8bcba4 | 194 | bool found = false; |
AzureIoTClient | 23:1111ee8bcba4 | 195 | bool is_error = false; |
AzureIoTClient | 1:eab586236bfe | 196 | |
AzureIoTClient | 23:1111ee8bcba4 | 197 | /* Codes_SRS_AMQP_MANAGEMENT_01_124: [ The status description shall be looked up in the application properties by using `amqpvalue_get_map_value`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 198 | desc_value = amqpvalue_get_map_value(map, desc_key); |
AzureIoTClient | 23:1111ee8bcba4 | 199 | if (desc_value != NULL) |
AzureIoTClient | 1:eab586236bfe | 200 | { |
AzureIoTClient | 23:1111ee8bcba4 | 201 | /* Codes_SRS_AMQP_MANAGEMENT_01_134: [ The status description value shall be extracted from the value found in the map by using `amqpvalue_get_string`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 202 | if (amqpvalue_get_string(desc_value, &status_description) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 203 | { |
AzureIoTClient | 23:1111ee8bcba4 | 204 | /* Codes_SRS_AMQP_MANAGEMENT_01_125: [ If status description is not found, NULL shall be passed to the user callback as `status_description` argument. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 205 | status_description = NULL; |
AzureIoTClient | 23:1111ee8bcba4 | 206 | } |
AzureIoTClient | 1:eab586236bfe | 207 | } |
AzureIoTClient | 1:eab586236bfe | 208 | else |
AzureIoTClient | 1:eab586236bfe | 209 | { |
AzureIoTClient | 23:1111ee8bcba4 | 210 | /* Codes_SRS_AMQP_MANAGEMENT_01_125: [ If status description is not found, NULL shall be passed to the user callback as `status_description` argument. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 211 | status_description = NULL; |
AzureIoTClient | 23:1111ee8bcba4 | 212 | } |
AzureIoTClient | 23:1111ee8bcba4 | 213 | |
AzureIoTClient | 23:1111ee8bcba4 | 214 | list_item_handle = singlylinkedlist_get_head_item(amqp_management->pending_operations); |
AzureIoTClient | 23:1111ee8bcba4 | 215 | while (list_item_handle != NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 216 | { |
AzureIoTClient | 23:1111ee8bcba4 | 217 | /* Codes_SRS_AMQP_MANAGEMENT_01_116: [ Each pending operation item value shall be obtained by calling `singlylinkedlist_item_get_value`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 218 | OPERATION_MESSAGE_INSTANCE* operation_message = (OPERATION_MESSAGE_INSTANCE*)singlylinkedlist_item_get_value(list_item_handle); |
AzureIoTClient | 23:1111ee8bcba4 | 219 | if (operation_message == NULL) |
AzureIoTClient | 1:eab586236bfe | 220 | { |
AzureIoTClient | 23:1111ee8bcba4 | 221 | /* Codes_SRS_AMQP_MANAGEMENT_01_117: [ If iterating through the pending operations list fails, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 222 | LogError("Could not create status-description amqp value"); |
AzureIoTClient | 23:1111ee8bcba4 | 223 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 224 | /* Codes_SRS_AMQP_MANAGEMENT_01_135: [ When an error occurs in creating AMQP values (for status code, etc.) `on_message_received` shall call `messaging_delivery_released` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 225 | result = messaging_delivery_released(); |
AzureIoTClient | 1:eab586236bfe | 226 | break; |
AzureIoTClient | 1:eab586236bfe | 227 | } |
AzureIoTClient | 1:eab586236bfe | 228 | else |
AzureIoTClient | 1:eab586236bfe | 229 | { |
AzureIoTClient | 23:1111ee8bcba4 | 230 | AMQP_MANAGEMENT_EXECUTE_OPERATION_RESULT execute_operation_result; |
AzureIoTClient | 23:1111ee8bcba4 | 231 | |
AzureIoTClient | 23:1111ee8bcba4 | 232 | /* Codes_SRS_AMQP_MANAGEMENT_01_112: [ `on_message_received` shall check if the correlation Id matches the stored message Id of any pending operation. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 233 | /* Codes_SRS_AMQP_MANAGEMENT_01_068: [ The correlation-id of the response message MUST be the correlation-id from the request message (if present) ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 234 | /* Codes_SRS_AMQP_MANAGEMENT_01_069: [ else the message-id from the request message. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 235 | if (correlation_id == operation_message->message_id) |
AzureIoTClient | 23:1111ee8bcba4 | 236 | { |
AzureIoTClient | 23:1111ee8bcba4 | 237 | /* Codes_SRS_AMQP_MANAGEMENT_01_074: [ Successful operations MUST result in a statusCode in the 2xx range as defined in Section 10.2 of [RFC2616]. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 238 | if ((status_code < 200) || (status_code > 299)) |
AzureIoTClient | 23:1111ee8bcba4 | 239 | { |
AzureIoTClient | 23:1111ee8bcba4 | 240 | /* Codes_SRS_AMQP_MANAGEMENT_01_128: [ If the status indicates that the operation failed, the result callback argument shall be `AMQP_MANAGEMENT_EXECUTE_OPERATION_FAILED_BAD_STATUS`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 241 | /* Codes_SRS_AMQP_MANAGEMENT_01_075: [ Unsuccessful operations MUST NOT result in a statusCode in the 2xx range as defined in Section 10.2 of [RFC2616]. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 242 | execute_operation_result = AMQP_MANAGEMENT_EXECUTE_OPERATION_FAILED_BAD_STATUS; |
AzureIoTClient | 23:1111ee8bcba4 | 243 | } |
AzureIoTClient | 23:1111ee8bcba4 | 244 | else |
AzureIoTClient | 23:1111ee8bcba4 | 245 | { |
AzureIoTClient | 23:1111ee8bcba4 | 246 | /* Codes_SRS_AMQP_MANAGEMENT_01_127: [ If the operation succeeded the result callback argument shall be `AMQP_MANAGEMENT_EXECUTE_OPERATION_OK`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 247 | execute_operation_result = AMQP_MANAGEMENT_EXECUTE_OPERATION_OK; |
AzureIoTClient | 23:1111ee8bcba4 | 248 | } |
AzureIoTClient | 23:1111ee8bcba4 | 249 | |
AzureIoTClient | 23:1111ee8bcba4 | 250 | /* Codes_SRS_AMQP_MANAGEMENT_01_126: [ If a corresponding correlation Id is found in the pending operations list, the callback associated with the pending operation shall be called. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 251 | /* Codes_SRS_AMQP_MANAGEMENT_01_166: [ The `message` shall be passed as argument to the callback. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 252 | operation_message->on_execute_operation_complete(operation_message->callback_context, execute_operation_result, status_code, status_description, message); |
AzureIoTClient | 23:1111ee8bcba4 | 253 | |
AzureIoTClient | 23:1111ee8bcba4 | 254 | free(operation_message); |
AzureIoTClient | 23:1111ee8bcba4 | 255 | |
AzureIoTClient | 23:1111ee8bcba4 | 256 | /* Codes_SRS_AMQP_MANAGEMENT_01_129: [ After calling the callback, the pending operation shall be removed from the pending operations list by calling `singlylinkedlist_remove`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 257 | if (singlylinkedlist_remove(amqp_management->pending_operations, list_item_handle) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 258 | { |
AzureIoTClient | 23:1111ee8bcba4 | 259 | LogError("Cannot remove pending operation"); |
AzureIoTClient | 23:1111ee8bcba4 | 260 | is_error = true; |
AzureIoTClient | 23:1111ee8bcba4 | 261 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 262 | } |
AzureIoTClient | 23:1111ee8bcba4 | 263 | else |
AzureIoTClient | 23:1111ee8bcba4 | 264 | { |
AzureIoTClient | 23:1111ee8bcba4 | 265 | found = true; |
AzureIoTClient | 23:1111ee8bcba4 | 266 | } |
AzureIoTClient | 23:1111ee8bcba4 | 267 | |
AzureIoTClient | 23:1111ee8bcba4 | 268 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 269 | } |
AzureIoTClient | 1:eab586236bfe | 270 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 271 | |
AzureIoTClient | 23:1111ee8bcba4 | 272 | /* Codes_SRS_AMQP_MANAGEMENT_01_115: [ Iterating through the pending operations shall be done by using `singlylinkedlist_get_head_item` and `singlylinkedlist_get_next_item` until the enm of the pending operations singly linked list is reached. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 273 | /* Codes_SRS_AMQP_MANAGEMENT_01_117: [ If iterating through the pending operations list fails, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 274 | list_item_handle = singlylinkedlist_get_next_item(list_item_handle); |
AzureIoTClient | 23:1111ee8bcba4 | 275 | } |
AzureIoTClient | 23:1111ee8bcba4 | 276 | |
AzureIoTClient | 23:1111ee8bcba4 | 277 | if (is_error) |
AzureIoTClient | 23:1111ee8bcba4 | 278 | { |
AzureIoTClient | 23:1111ee8bcba4 | 279 | /* Codes_SRS_AMQP_MANAGEMENT_01_117: [ If iterating through the pending operations list fails, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 280 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 281 | /* Codes_SRS_AMQP_MANAGEMENT_01_135: [ When an error occurs in creating AMQP values (for status code, etc.) `on_message_received` shall call `messaging_delivery_released` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 282 | result = messaging_delivery_released(); |
AzureIoTClient | 1:eab586236bfe | 283 | } |
AzureIoTClient | 23:1111ee8bcba4 | 284 | else |
AzureIoTClient | 23:1111ee8bcba4 | 285 | { |
AzureIoTClient | 23:1111ee8bcba4 | 286 | if (!found) |
AzureIoTClient | 23:1111ee8bcba4 | 287 | { |
AzureIoTClient | 23:1111ee8bcba4 | 288 | /* Codes_SRS_AMQP_MANAGEMENT_01_118: [ If no pending operation is found matching the correlation Id, an error shall be indicated by calling `on_amqp_management_error` and passing the `on_amqp_management_error_context` to it. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 289 | LogError("Could not match AMQP management response to request"); |
AzureIoTClient | 23:1111ee8bcba4 | 290 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 291 | /* Codes_SRS_AMQP_MANAGEMENT_01_135: [ When an error occurs in creating AMQP values (for status code, etc.) `on_message_received` shall call `messaging_delivery_released` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 292 | result = messaging_delivery_rejected("amqp:internal-error", "Could not match AMQP management response to request"); |
AzureIoTClient | 23:1111ee8bcba4 | 293 | } |
AzureIoTClient | 23:1111ee8bcba4 | 294 | else |
AzureIoTClient | 23:1111ee8bcba4 | 295 | { |
AzureIoTClient | 23:1111ee8bcba4 | 296 | /* Codes_SRS_AMQP_MANAGEMENT_01_130: [ The `on_message_received` shall call `messaging_delivery_accepted` and return the created delivery AMQP value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 297 | result = messaging_delivery_accepted(); |
AzureIoTClient | 23:1111ee8bcba4 | 298 | } |
AzureIoTClient | 23:1111ee8bcba4 | 299 | } |
AzureIoTClient | 23:1111ee8bcba4 | 300 | |
AzureIoTClient | 23:1111ee8bcba4 | 301 | if (desc_value != NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 302 | { |
AzureIoTClient | 23:1111ee8bcba4 | 303 | /* Codes_SRS_AMQP_MANAGEMENT_01_131: [ All temporary values like AMQP values used as keys shall be freed before exiting the callback. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 304 | amqpvalue_destroy(desc_value); |
AzureIoTClient | 23:1111ee8bcba4 | 305 | } |
AzureIoTClient | 23:1111ee8bcba4 | 306 | |
AzureIoTClient | 23:1111ee8bcba4 | 307 | /* Codes_SRS_AMQP_MANAGEMENT_01_131: [ All temporary values like AMQP values used as keys shall be freed before exiting the callback. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 308 | amqpvalue_destroy(desc_key); |
AzureIoTClient | 1:eab586236bfe | 309 | } |
AzureIoTClient | 1:eab586236bfe | 310 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 311 | |
AzureIoTClient | 23:1111ee8bcba4 | 312 | /* Codes_SRS_AMQP_MANAGEMENT_01_131: [ All temporary values like AMQP values used as keys shall be freed before exiting the callback. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 313 | amqpvalue_destroy(value); |
AzureIoTClient | 6:641a9672db08 | 314 | } |
AzureIoTClient | 23:1111ee8bcba4 | 315 | |
AzureIoTClient | 23:1111ee8bcba4 | 316 | /* Codes_SRS_AMQP_MANAGEMENT_01_131: [ All temporary values like AMQP values used as keys shall be freed before exiting the callback. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 317 | amqpvalue_destroy(key); |
AzureIoTClient | 6:641a9672db08 | 318 | } |
AzureIoTClient | 6:641a9672db08 | 319 | } |
AzureIoTClient | 6:641a9672db08 | 320 | } |
AzureIoTClient | 6:641a9672db08 | 321 | } |
AzureIoTClient | 23:1111ee8bcba4 | 322 | |
AzureIoTClient | 23:1111ee8bcba4 | 323 | /* Codes_SRS_AMQP_MANAGEMENT_01_131: [ All temporary values like AMQP values used as keys shall be freed before exiting the callback. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 324 | properties_destroy(response_properties); |
AzureIoTClient | 6:641a9672db08 | 325 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 326 | |
AzureIoTClient | 23:1111ee8bcba4 | 327 | /* Codes_SRS_AMQP_MANAGEMENT_01_131: [ All temporary values like AMQP values used as keys shall be freed before exiting the callback. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 328 | application_properties_destroy(application_properties); |
AzureIoTClient | 6:641a9672db08 | 329 | } |
AzureIoTClient | 6:641a9672db08 | 330 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 331 | |
AzureIoTClient | 6:641a9672db08 | 332 | return result; |
Azure.IoT Build | 0:6ae2f7bca550 | 333 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 334 | |
AzureIoTClient | 41:0e723f9cbd89 | 335 | static void on_message_send_complete(void* context, MESSAGE_SEND_RESULT send_result) |
AzureIoTClient | 41:0e723f9cbd89 | 336 | { |
AzureIoTClient | 41:0e723f9cbd89 | 337 | if (context == NULL) |
AzureIoTClient | 41:0e723f9cbd89 | 338 | { |
AzureIoTClient | 41:0e723f9cbd89 | 339 | /* Codes_SRS_AMQP_MANAGEMENT_01_167: [ When `on_message_send_complete` is called with a NULL context it shall return. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 340 | LogError("NULL context"); |
AzureIoTClient | 41:0e723f9cbd89 | 341 | } |
AzureIoTClient | 41:0e723f9cbd89 | 342 | else |
AzureIoTClient | 41:0e723f9cbd89 | 343 | { |
AzureIoTClient | 41:0e723f9cbd89 | 344 | if (send_result == MESSAGE_SEND_OK) |
AzureIoTClient | 41:0e723f9cbd89 | 345 | { |
AzureIoTClient | 41:0e723f9cbd89 | 346 | /* Codes_SRS_AMQP_MANAGEMENT_01_170: [ If `send_result` is `MESSAGE_SEND_OK`, `on_message_send_complete` shall return. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 347 | } |
AzureIoTClient | 41:0e723f9cbd89 | 348 | else |
AzureIoTClient | 41:0e723f9cbd89 | 349 | { |
AzureIoTClient | 41:0e723f9cbd89 | 350 | /* Codes_SRS_AMQP_MANAGEMENT_01_172: [ If `send_result` is different then `MESSAGE_SEND_OK`: ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 351 | /* Codes_SRS_AMQP_MANAGEMENT_01_168: [ - `context` shall be used as a LIST_ITEM_HANDLE containing the pending operation. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 352 | LIST_ITEM_HANDLE pending_operation_list_item_handle = (LIST_ITEM_HANDLE)context; |
AzureIoTClient | 41:0e723f9cbd89 | 353 | |
AzureIoTClient | 41:0e723f9cbd89 | 354 | /* Codes_SRS_AMQP_MANAGEMENT_01_169: [ - `on_message_send_complete` shall obtain the pending operation by calling `singlylinkedlist_item_get_value`. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 355 | OPERATION_MESSAGE_INSTANCE* pending_operation_message = (OPERATION_MESSAGE_INSTANCE*)singlylinkedlist_item_get_value(pending_operation_list_item_handle); |
AzureIoTClient | 41:0e723f9cbd89 | 356 | AMQP_MANAGEMENT_HANDLE amqp_management = pending_operation_message->amqp_management; |
AzureIoTClient | 41:0e723f9cbd89 | 357 | |
AzureIoTClient | 41:0e723f9cbd89 | 358 | /* Codes_SRS_AMQP_MANAGEMENT_01_171: [ - `on_message_send_complete` shall removed the pending operation from the pending operations list. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 359 | if (singlylinkedlist_remove(amqp_management->pending_operations, pending_operation_list_item_handle) != 0) |
AzureIoTClient | 41:0e723f9cbd89 | 360 | { |
AzureIoTClient | 41:0e723f9cbd89 | 361 | /* Tests_SRS_AMQP_MANAGEMENT_01_174: [ If any error occurs in removing the pending operation from the list `on_amqp_management_error` callback shall be invoked while passing the `on_amqp_management_error_context` as argument. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 362 | amqp_management->on_amqp_management_error(amqp_management->on_amqp_management_error_context); |
AzureIoTClient | 41:0e723f9cbd89 | 363 | LogError("Cannot remove pending operation"); |
AzureIoTClient | 41:0e723f9cbd89 | 364 | } |
AzureIoTClient | 41:0e723f9cbd89 | 365 | else |
AzureIoTClient | 41:0e723f9cbd89 | 366 | { |
AzureIoTClient | 41:0e723f9cbd89 | 367 | /* Codes_SRS_AMQP_MANAGEMENT_01_173: [ - The callback associated with the pending operation shall be called with `AMQP_MANAGEMENT_EXECUTE_OPERATION_ERROR`. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 368 | pending_operation_message->on_execute_operation_complete(pending_operation_message->callback_context, AMQP_MANAGEMENT_EXECUTE_OPERATION_ERROR, 0, NULL, NULL); |
AzureIoTClient | 41:0e723f9cbd89 | 369 | free(pending_operation_message); |
AzureIoTClient | 41:0e723f9cbd89 | 370 | } |
AzureIoTClient | 41:0e723f9cbd89 | 371 | } |
AzureIoTClient | 41:0e723f9cbd89 | 372 | } |
AzureIoTClient | 41:0e723f9cbd89 | 373 | } |
AzureIoTClient | 41:0e723f9cbd89 | 374 | |
Azure.IoT Build | 0:6ae2f7bca550 | 375 | static void on_message_sender_state_changed(void* context, MESSAGE_SENDER_STATE new_state, MESSAGE_SENDER_STATE previous_state) |
Azure.IoT Build | 0:6ae2f7bca550 | 376 | { |
AzureIoTClient | 23:1111ee8bcba4 | 377 | if (context == NULL) |
AzureIoTClient | 6:641a9672db08 | 378 | { |
AzureIoTClient | 23:1111ee8bcba4 | 379 | /* Codes_SRS_AMQP_MANAGEMENT_01_137: [ When `on_message_sender_state_changed` is called with NULL `context`, it shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 380 | LogError("on_message_sender_state_changed called with NULL context"); |
AzureIoTClient | 23:1111ee8bcba4 | 381 | } |
AzureIoTClient | 23:1111ee8bcba4 | 382 | else |
AzureIoTClient | 23:1111ee8bcba4 | 383 | { |
AzureIoTClient | 23:1111ee8bcba4 | 384 | /* Codes_SRS_AMQP_MANAGEMENT_01_138: [ When `on_message_sender_state_changed` is called and the `new_state` is different than `previous_state`, the following actions shall be taken: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 385 | /* Codes_SRS_AMQP_MANAGEMENT_01_148: [ When no state change is detected, `on_message_sender_state_changed` shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 386 | if (new_state != previous_state) |
AzureIoTClient | 22:524bded3f7a8 | 387 | { |
AzureIoTClient | 23:1111ee8bcba4 | 388 | AMQP_MANAGEMENT_INSTANCE* amqp_management_instance = (AMQP_MANAGEMENT_INSTANCE*)context; |
AzureIoTClient | 23:1111ee8bcba4 | 389 | switch (amqp_management_instance->amqp_management_state) |
AzureIoTClient | 23:1111ee8bcba4 | 390 | { |
AzureIoTClient | 23:1111ee8bcba4 | 391 | default: |
AzureIoTClient | 23:1111ee8bcba4 | 392 | break; |
AzureIoTClient | 22:524bded3f7a8 | 393 | |
AzureIoTClient | 23:1111ee8bcba4 | 394 | /* Codes_SRS_AMQP_MANAGEMENT_01_139: [ For the current state of AMQP management being `OPENING`: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 395 | case AMQP_MANAGEMENT_STATE_OPENING: |
AzureIoTClient | 22:524bded3f7a8 | 396 | { |
AzureIoTClient | 23:1111ee8bcba4 | 397 | switch (new_state) |
AzureIoTClient | 23:1111ee8bcba4 | 398 | { |
AzureIoTClient | 23:1111ee8bcba4 | 399 | case MESSAGE_SENDER_STATE_OPENING: |
AzureIoTClient | 23:1111ee8bcba4 | 400 | /* Codes_SRS_AMQP_MANAGEMENT_01_165: [ - If `new_state` is `MESSAGE_SENDER_STATE_OPEING` the transition shall be ignored. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 401 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 402 | |
AzureIoTClient | 23:1111ee8bcba4 | 403 | default: |
AzureIoTClient | 23:1111ee8bcba4 | 404 | /* Codes_SRS_AMQP_MANAGEMENT_01_140: [ - If `new_state` is `MESSAGE_SENDER_STATE_IDLE`, `MESSAGE_SENDER_STATE_CLOSING` or `MESSAGE_SENDER_STATE_ERROR`, the `on_amqp_management_open_complete` callback shall be called with `AMQP_MANAGEMENT_OPEN_ERROR`, while also passing the context passed in `amqp_management_open_async`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 405 | case MESSAGE_SENDER_STATE_IDLE: |
AzureIoTClient | 23:1111ee8bcba4 | 406 | case MESSAGE_SENDER_STATE_CLOSING: |
AzureIoTClient | 23:1111ee8bcba4 | 407 | case MESSAGE_SENDER_STATE_ERROR: |
AzureIoTClient | 23:1111ee8bcba4 | 408 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_IDLE; |
AzureIoTClient | 23:1111ee8bcba4 | 409 | amqp_management_instance->on_amqp_management_open_complete(amqp_management_instance->on_amqp_management_open_complete_context, AMQP_MANAGEMENT_OPEN_ERROR); |
AzureIoTClient | 23:1111ee8bcba4 | 410 | break; |
AzureIoTClient | 22:524bded3f7a8 | 411 | |
AzureIoTClient | 23:1111ee8bcba4 | 412 | case MESSAGE_SENDER_STATE_OPEN: |
AzureIoTClient | 23:1111ee8bcba4 | 413 | amqp_management_instance->sender_connected = -1; |
AzureIoTClient | 23:1111ee8bcba4 | 414 | /* Codes_SRS_AMQP_MANAGEMENT_01_142: [ - If `new_state` is `MESSAGE_SENDER_STATE_OPEN` and the message receiver did not yet indicate its state as `MESSAGE_RECEIVER_STATE_OPEN`, the `on_amqp_management_open_complete` callback shall not be called.]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 415 | if (amqp_management_instance->receiver_connected != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 416 | { |
AzureIoTClient | 23:1111ee8bcba4 | 417 | /* Codes_SRS_AMQP_MANAGEMENT_01_141: [ - If `new_state` is `MESSAGE_SENDER_STATE_OPEN` and the message receiver already indicated its state as `MESSAGE_RECEIVER_STATE_OPEN`, the `on_amqp_management_open_complete` callback shall be called with `AMQP_MANAGEMENT_OPEN_OK`, while also passing the context passed in `amqp_management_open_async`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 418 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_OPEN; |
AzureIoTClient | 23:1111ee8bcba4 | 419 | amqp_management_instance->on_amqp_management_open_complete(amqp_management_instance->on_amqp_management_open_complete_context, AMQP_MANAGEMENT_OPEN_OK); |
AzureIoTClient | 23:1111ee8bcba4 | 420 | } |
AzureIoTClient | 23:1111ee8bcba4 | 421 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 422 | } |
AzureIoTClient | 23:1111ee8bcba4 | 423 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 424 | } |
AzureIoTClient | 23:1111ee8bcba4 | 425 | /* Codes_SRS_AMQP_MANAGEMENT_01_144: [ For the current state of AMQP management being `OPEN`: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 426 | case AMQP_MANAGEMENT_STATE_OPEN: |
AzureIoTClient | 23:1111ee8bcba4 | 427 | { |
AzureIoTClient | 23:1111ee8bcba4 | 428 | switch (new_state) |
AzureIoTClient | 23:1111ee8bcba4 | 429 | { |
AzureIoTClient | 23:1111ee8bcba4 | 430 | default: |
AzureIoTClient | 23:1111ee8bcba4 | 431 | /* Codes_SRS_AMQP_MANAGEMENT_01_143: [ - If `new_state` is `MESSAGE_SENDER_STATE_IDLE`, `MESSAGE_SENDER_STATE_OPENING`, `MESSAGE_SENDER_STATE_CLOSING` or `MESSAGE_SENDER_STATE_ERROR` the `on_amqp_management_error` callback shall be invoked while passing the `on_amqp_management_error_context` as argument. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 432 | case MESSAGE_SENDER_STATE_IDLE: |
AzureIoTClient | 23:1111ee8bcba4 | 433 | case MESSAGE_SENDER_STATE_CLOSING: |
AzureIoTClient | 23:1111ee8bcba4 | 434 | case MESSAGE_SENDER_STATE_ERROR: |
AzureIoTClient | 23:1111ee8bcba4 | 435 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_ERROR; |
AzureIoTClient | 23:1111ee8bcba4 | 436 | amqp_management_instance->on_amqp_management_error(amqp_management_instance->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 437 | break; |
Azure.IoT Build | 0:6ae2f7bca550 | 438 | |
AzureIoTClient | 23:1111ee8bcba4 | 439 | case MESSAGE_SENDER_STATE_OPEN: |
AzureIoTClient | 23:1111ee8bcba4 | 440 | /* Codes_SRS_AMQP_MANAGEMENT_01_145: [ - If `new_state` is `MESSAGE_SENDER_STATE_OPEN`, `on_message_sender_state_changed` shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 441 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 442 | } |
AzureIoTClient | 23:1111ee8bcba4 | 443 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 444 | } |
AzureIoTClient | 41:0e723f9cbd89 | 445 | /* Codes_SRS_AMQP_MANAGEMENT_09_001: [ For the current state of AMQP management being `CLOSING`: ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 446 | case AMQP_MANAGEMENT_STATE_CLOSING: |
AzureIoTClient | 41:0e723f9cbd89 | 447 | { |
AzureIoTClient | 41:0e723f9cbd89 | 448 | switch (new_state) |
AzureIoTClient | 41:0e723f9cbd89 | 449 | { |
AzureIoTClient | 41:0e723f9cbd89 | 450 | default: |
AzureIoTClient | 41:0e723f9cbd89 | 451 | /* Codes_SRS_AMQP_MANAGEMENT_09_002: [ - If `new_state` is `MESSAGE_SENDER_STATE_OPEN`, `MESSAGE_SENDER_STATE_OPENING`, `MESSAGE_SENDER_STATE_ERROR` the `on_amqp_management_error` callback shall be invoked while passing the `on_amqp_management_error_context` as argument. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 452 | case MESSAGE_SENDER_STATE_OPEN: |
AzureIoTClient | 41:0e723f9cbd89 | 453 | case MESSAGE_SENDER_STATE_OPENING: |
AzureIoTClient | 41:0e723f9cbd89 | 454 | case MESSAGE_SENDER_STATE_ERROR: |
AzureIoTClient | 41:0e723f9cbd89 | 455 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_ERROR; |
AzureIoTClient | 41:0e723f9cbd89 | 456 | amqp_management_instance->on_amqp_management_error(amqp_management_instance->on_amqp_management_error_context); |
AzureIoTClient | 41:0e723f9cbd89 | 457 | break; |
AzureIoTClient | 41:0e723f9cbd89 | 458 | case MESSAGE_SENDER_STATE_IDLE: |
AzureIoTClient | 41:0e723f9cbd89 | 459 | case MESSAGE_SENDER_STATE_CLOSING: |
AzureIoTClient | 41:0e723f9cbd89 | 460 | /* Codes_SRS_AMQP_MANAGEMENT_09_003: [ - If `new_state` is `MESSAGE_SENDER_STATE_CLOSING` or `MESSAGE_SENDER_STATE_IDLE`, `on_message_sender_state_changed` shall do nothing. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 461 | break; |
AzureIoTClient | 41:0e723f9cbd89 | 462 | } |
AzureIoTClient | 41:0e723f9cbd89 | 463 | break; |
AzureIoTClient | 41:0e723f9cbd89 | 464 | } |
AzureIoTClient | 23:1111ee8bcba4 | 465 | /* Codes_SRS_AMQP_MANAGEMENT_01_146: [ For the current state of AMQP management being `ERROR`: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 466 | case AMQP_MANAGEMENT_STATE_ERROR: |
AzureIoTClient | 23:1111ee8bcba4 | 467 | /* Codes_SRS_AMQP_MANAGEMENT_01_147: [ - All state transitions shall be ignored. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 468 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 469 | } |
AzureIoTClient | 22:524bded3f7a8 | 470 | } |
AzureIoTClient | 6:641a9672db08 | 471 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 472 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 473 | |
Azure.IoT Build | 0:6ae2f7bca550 | 474 | static void on_message_receiver_state_changed(const void* context, MESSAGE_RECEIVER_STATE new_state, MESSAGE_RECEIVER_STATE previous_state) |
Azure.IoT Build | 0:6ae2f7bca550 | 475 | { |
AzureIoTClient | 23:1111ee8bcba4 | 476 | if (context == NULL) |
AzureIoTClient | 6:641a9672db08 | 477 | { |
AzureIoTClient | 23:1111ee8bcba4 | 478 | /* Codes_SRS_AMQP_MANAGEMENT_01_149: [ When `on_message_receiver_state_changed` is called with NULL `context`, it shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 479 | LogError("on_message_receiver_state_changed called with NULL context"); |
AzureIoTClient | 23:1111ee8bcba4 | 480 | } |
AzureIoTClient | 23:1111ee8bcba4 | 481 | else |
AzureIoTClient | 23:1111ee8bcba4 | 482 | { |
AzureIoTClient | 23:1111ee8bcba4 | 483 | /* Codes_SRS_AMQP_MANAGEMENT_01_150: [ When `on_message_receiver_state_changed` is called and the `new_state` is different than `previous_state`, the following actions shall be taken: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 484 | /* Codes_SRS_AMQP_MANAGEMENT_01_160: [ When no state change is detected, `on_message_receiver_state_changed` shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 485 | if (new_state != previous_state) |
AzureIoTClient | 22:524bded3f7a8 | 486 | { |
AzureIoTClient | 23:1111ee8bcba4 | 487 | AMQP_MANAGEMENT_INSTANCE* amqp_management_instance = (AMQP_MANAGEMENT_INSTANCE*)context; |
AzureIoTClient | 23:1111ee8bcba4 | 488 | switch (amqp_management_instance->amqp_management_state) |
AzureIoTClient | 23:1111ee8bcba4 | 489 | { |
AzureIoTClient | 23:1111ee8bcba4 | 490 | default: |
AzureIoTClient | 23:1111ee8bcba4 | 491 | break; |
AzureIoTClient | 22:524bded3f7a8 | 492 | |
AzureIoTClient | 23:1111ee8bcba4 | 493 | /* Codes_SRS_AMQP_MANAGEMENT_01_151: [ For the current state of AMQP management being `OPENING`: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 494 | case AMQP_MANAGEMENT_STATE_OPENING: |
AzureIoTClient | 22:524bded3f7a8 | 495 | { |
AzureIoTClient | 23:1111ee8bcba4 | 496 | switch (new_state) |
AzureIoTClient | 23:1111ee8bcba4 | 497 | { |
AzureIoTClient | 23:1111ee8bcba4 | 498 | case MESSAGE_RECEIVER_STATE_OPENING: |
AzureIoTClient | 23:1111ee8bcba4 | 499 | /* Codes_SRS_AMQP_MANAGEMENT_01_164: [ - If `new_state` is `MESSAGE_RECEIVER_STATE_OPEING` the transition shall be ignored. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 500 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 501 | |
AzureIoTClient | 23:1111ee8bcba4 | 502 | default: |
AzureIoTClient | 23:1111ee8bcba4 | 503 | /* Codes_SRS_AMQP_MANAGEMENT_01_152: [ - If `new_state` is `MESSAGE_RECEIVER_STATE_IDLE`, `MESSAGE_RECEIVER_STATE_CLOSING` or `MESSAGE_RECEIVER_STATE_ERROR`, the `on_amqp_management_open_complete` callback shall be called with `AMQP_MANAGEMENT_OPEN_ERROR`, while also passing the context passed in `amqp_management_open_async`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 504 | case MESSAGE_RECEIVER_STATE_IDLE: |
AzureIoTClient | 23:1111ee8bcba4 | 505 | case MESSAGE_RECEIVER_STATE_CLOSING: |
AzureIoTClient | 23:1111ee8bcba4 | 506 | case MESSAGE_RECEIVER_STATE_ERROR: |
AzureIoTClient | 23:1111ee8bcba4 | 507 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_IDLE; |
AzureIoTClient | 23:1111ee8bcba4 | 508 | amqp_management_instance->on_amqp_management_open_complete(amqp_management_instance->on_amqp_management_open_complete_context, AMQP_MANAGEMENT_OPEN_ERROR); |
AzureIoTClient | 23:1111ee8bcba4 | 509 | break; |
AzureIoTClient | 22:524bded3f7a8 | 510 | |
AzureIoTClient | 23:1111ee8bcba4 | 511 | case MESSAGE_RECEIVER_STATE_OPEN: |
AzureIoTClient | 23:1111ee8bcba4 | 512 | amqp_management_instance->receiver_connected = -1; |
AzureIoTClient | 23:1111ee8bcba4 | 513 | /* Codes_SRS_AMQP_MANAGEMENT_01_154: [ - If `new_state` is `MESSAGE_RECEIVER_STATE_OPEN` and the message sender did not yet indicate its state as `MESSAGE_RECEIVER_STATE_OPEN`, the `on_amqp_management_open_complete` callback shall not be called. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 514 | if (amqp_management_instance->sender_connected != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 515 | { |
AzureIoTClient | 23:1111ee8bcba4 | 516 | /* Codes_SRS_AMQP_MANAGEMENT_01_153: [ - If `new_state` is `MESSAGE_RECEIVER_STATE_OPEN` and the message sender already indicated its state as `MESSAGE_RECEIVER_STATE_OPEN`, the `on_amqp_management_open_complete` callback shall be called with `AMQP_MANAGEMENT_OPEN_OK`, while also passing the context passed in `amqp_management_open_async`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 517 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_OPEN; |
AzureIoTClient | 23:1111ee8bcba4 | 518 | amqp_management_instance->on_amqp_management_open_complete(amqp_management_instance->on_amqp_management_open_complete_context, AMQP_MANAGEMENT_OPEN_OK); |
AzureIoTClient | 23:1111ee8bcba4 | 519 | } |
AzureIoTClient | 23:1111ee8bcba4 | 520 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 521 | } |
AzureIoTClient | 23:1111ee8bcba4 | 522 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 523 | } |
AzureIoTClient | 23:1111ee8bcba4 | 524 | /* Codes_SRS_AMQP_MANAGEMENT_01_155: [ For the current state of AMQP management being `OPEN`: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 525 | case AMQP_MANAGEMENT_STATE_OPEN: |
AzureIoTClient | 23:1111ee8bcba4 | 526 | { |
AzureIoTClient | 23:1111ee8bcba4 | 527 | switch (new_state) |
AzureIoTClient | 23:1111ee8bcba4 | 528 | { |
AzureIoTClient | 23:1111ee8bcba4 | 529 | default: |
AzureIoTClient | 23:1111ee8bcba4 | 530 | /* Codes_SRS_AMQP_MANAGEMENT_01_156: [ - If `new_state` is `MESSAGE_RECEIVER_STATE_IDLE`, `MESSAGE_RECEIVER_STATE_OPENING`, `MESSAGE_RECEIVER_STATE_CLOSING` or `MESSAGE_RECEIVER_STATE_ERROR` the `on_amqp_management_error` callback shall be invoked while passing the `on_amqp_management_error_context` as argument. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 531 | case MESSAGE_RECEIVER_STATE_IDLE: |
AzureIoTClient | 23:1111ee8bcba4 | 532 | case MESSAGE_RECEIVER_STATE_CLOSING: |
AzureIoTClient | 23:1111ee8bcba4 | 533 | case MESSAGE_RECEIVER_STATE_ERROR: |
AzureIoTClient | 23:1111ee8bcba4 | 534 | amqp_management_instance->amqp_management_state = AMQP_MANAGEMENT_STATE_ERROR; |
AzureIoTClient | 23:1111ee8bcba4 | 535 | amqp_management_instance->on_amqp_management_error(amqp_management_instance->on_amqp_management_error_context); |
AzureIoTClient | 23:1111ee8bcba4 | 536 | break; |
Azure.IoT Build | 0:6ae2f7bca550 | 537 | |
AzureIoTClient | 23:1111ee8bcba4 | 538 | case MESSAGE_RECEIVER_STATE_OPEN: |
AzureIoTClient | 23:1111ee8bcba4 | 539 | /* Codes_SRS_AMQP_MANAGEMENT_01_157: [ - If `new_state` is `MESSAGE_RECEIVER_STATE_OPEN`, `on_message_receiver_state_changed` shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 540 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 541 | } |
AzureIoTClient | 23:1111ee8bcba4 | 542 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 543 | } |
AzureIoTClient | 23:1111ee8bcba4 | 544 | /* Codes_SRS_AMQP_MANAGEMENT_01_158: [ For the current state of AMQP management being `ERROR`: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 545 | case AMQP_MANAGEMENT_STATE_ERROR: |
AzureIoTClient | 23:1111ee8bcba4 | 546 | /* Codes_SRS_AMQP_MANAGEMENT_01_159: [ - All state transitions shall be ignored. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 547 | break; |
AzureIoTClient | 23:1111ee8bcba4 | 548 | } |
AzureIoTClient | 22:524bded3f7a8 | 549 | } |
AzureIoTClient | 6:641a9672db08 | 550 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 551 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 552 | |
AzureIoTClient | 23:1111ee8bcba4 | 553 | static int set_message_id(MESSAGE_HANDLE message, uint64_t next_message_id) |
Azure.IoT Build | 0:6ae2f7bca550 | 554 | { |
AzureIoTClient | 23:1111ee8bcba4 | 555 | int result; |
AzureIoTClient | 23:1111ee8bcba4 | 556 | PROPERTIES_HANDLE properties; |
Azure.IoT Build | 0:6ae2f7bca550 | 557 | |
AzureIoTClient | 23:1111ee8bcba4 | 558 | /* Codes_SRS_AMQP_MANAGEMENT_01_094: [ In order to set the message Id on the message, the properties shall be obtained by calling `message_get_properties`. ]*/ |
AzureIoTClient | 6:641a9672db08 | 559 | if (message_get_properties(message, &properties) != 0) |
AzureIoTClient | 6:641a9672db08 | 560 | { |
AzureIoTClient | 23:1111ee8bcba4 | 561 | /* Codes_SRS_AMQP_MANAGEMENT_01_098: [ If any API fails while setting the message Id, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 562 | LogError("Could not retrieve message properties"); |
AzureIoTClient | 19:000ab4e6a2c1 | 563 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 564 | } |
AzureIoTClient | 6:641a9672db08 | 565 | else |
AzureIoTClient | 6:641a9672db08 | 566 | { |
AzureIoTClient | 23:1111ee8bcba4 | 567 | /* Codes_SRS_AMQP_MANAGEMENT_01_099: [ If the properties were not set on the message, a new properties instance shall be created by calling `properties_create`. ]*/ |
AzureIoTClient | 21:f9c433d8e6ca | 568 | if (properties == NULL) |
AzureIoTClient | 21:f9c433d8e6ca | 569 | { |
AzureIoTClient | 21:f9c433d8e6ca | 570 | properties = properties_create(); |
AzureIoTClient | 21:f9c433d8e6ca | 571 | } |
AzureIoTClient | 21:f9c433d8e6ca | 572 | |
AzureIoTClient | 21:f9c433d8e6ca | 573 | if (properties == NULL) |
AzureIoTClient | 6:641a9672db08 | 574 | { |
AzureIoTClient | 23:1111ee8bcba4 | 575 | /* Codes_SRS_AMQP_MANAGEMENT_01_098: [ If any API fails while setting the message Id, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 576 | LogError("Could not create message properties"); |
AzureIoTClient | 19:000ab4e6a2c1 | 577 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 578 | } |
AzureIoTClient | 6:641a9672db08 | 579 | else |
AzureIoTClient | 6:641a9672db08 | 580 | { |
AzureIoTClient | 23:1111ee8bcba4 | 581 | /* Codes_SRS_AMQP_MANAGEMENT_01_095: [ A message Id with the next ulong value to be used shall be created by calling `amqpvalue_create_message_id_ulong`. ]*/ |
AzureIoTClient | 21:f9c433d8e6ca | 582 | AMQP_VALUE message_id = amqpvalue_create_message_id_ulong(next_message_id); |
AzureIoTClient | 21:f9c433d8e6ca | 583 | if (message_id == NULL) |
AzureIoTClient | 21:f9c433d8e6ca | 584 | { |
AzureIoTClient | 23:1111ee8bcba4 | 585 | /* Codes_SRS_AMQP_MANAGEMENT_01_098: [ If any API fails while setting the message Id, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 586 | LogError("Could not create message id value"); |
AzureIoTClient | 21:f9c433d8e6ca | 587 | result = __FAILURE__; |
AzureIoTClient | 21:f9c433d8e6ca | 588 | } |
AzureIoTClient | 21:f9c433d8e6ca | 589 | else |
AzureIoTClient | 21:f9c433d8e6ca | 590 | { |
AzureIoTClient | 23:1111ee8bcba4 | 591 | /* Codes_SRS_AMQP_MANAGEMENT_01_096: [ The message Id value shall be set on the properties by calling `properties_set_message_id`. ]*/ |
AzureIoTClient | 21:f9c433d8e6ca | 592 | if (properties_set_message_id(properties, message_id) != 0) |
AzureIoTClient | 21:f9c433d8e6ca | 593 | { |
AzureIoTClient | 23:1111ee8bcba4 | 594 | /* Codes_SRS_AMQP_MANAGEMENT_01_098: [ If any API fails while setting the message Id, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 595 | LogError("Could not set message Id on the properties"); |
AzureIoTClient | 21:f9c433d8e6ca | 596 | result = __FAILURE__; |
AzureIoTClient | 21:f9c433d8e6ca | 597 | } |
AzureIoTClient | 23:1111ee8bcba4 | 598 | /* Codes_SRS_AMQP_MANAGEMENT_01_097: [ The properties thus modified to contain the message Id shall be set on the message by calling `message_set_properties`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 599 | else if (message_set_properties(message, properties) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 600 | { |
AzureIoTClient | 23:1111ee8bcba4 | 601 | /* Codes_SRS_AMQP_MANAGEMENT_01_098: [ If any API fails while setting the message Id, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 602 | LogError("Could not set message properties"); |
AzureIoTClient | 23:1111ee8bcba4 | 603 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 604 | } |
AzureIoTClient | 23:1111ee8bcba4 | 605 | else |
AzureIoTClient | 23:1111ee8bcba4 | 606 | { |
AzureIoTClient | 23:1111ee8bcba4 | 607 | result = 0; |
AzureIoTClient | 23:1111ee8bcba4 | 608 | } |
AzureIoTClient | 21:f9c433d8e6ca | 609 | |
AzureIoTClient | 21:f9c433d8e6ca | 610 | amqpvalue_destroy(message_id); |
AzureIoTClient | 21:f9c433d8e6ca | 611 | } |
AzureIoTClient | 21:f9c433d8e6ca | 612 | |
AzureIoTClient | 23:1111ee8bcba4 | 613 | /* Codes_SRS_AMQP_MANAGEMENT_01_100: [ After setting the properties, the properties instance shall be freed by `properties_destroy`. ]*/ |
AzureIoTClient | 21:f9c433d8e6ca | 614 | properties_destroy(properties); |
AzureIoTClient | 6:641a9672db08 | 615 | } |
AzureIoTClient | 6:641a9672db08 | 616 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 617 | |
AzureIoTClient | 6:641a9672db08 | 618 | return result; |
Azure.IoT Build | 0:6ae2f7bca550 | 619 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 620 | |
Azure.IoT Build | 0:6ae2f7bca550 | 621 | static int add_string_key_value_pair_to_map(AMQP_VALUE map, const char* key, const char* value) |
Azure.IoT Build | 0:6ae2f7bca550 | 622 | { |
AzureIoTClient | 6:641a9672db08 | 623 | int result; |
Azure.IoT Build | 0:6ae2f7bca550 | 624 | |
AzureIoTClient | 23:1111ee8bcba4 | 625 | /* Codes_SRS_AMQP_MANAGEMENT_01_084: [ For each of the arguments `operation`, `type` and `locales` an AMQP value of type string shall be created by calling `amqpvalue_create_string` in order to be used as key in the application properties map. ]*/ |
AzureIoTClient | 6:641a9672db08 | 626 | AMQP_VALUE key_value = amqpvalue_create_string(key); |
AzureIoTClient | 23:1111ee8bcba4 | 627 | if (key_value == NULL) |
AzureIoTClient | 6:641a9672db08 | 628 | { |
AzureIoTClient | 23:1111ee8bcba4 | 629 | /* Codes_SRS_AMQP_MANAGEMENT_01_090: [ If any APIs used to create and set the application properties on the message fails, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 630 | LogError("Could not create key value for %s", key); |
AzureIoTClient | 19:000ab4e6a2c1 | 631 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 632 | } |
AzureIoTClient | 6:641a9672db08 | 633 | else |
AzureIoTClient | 6:641a9672db08 | 634 | { |
AzureIoTClient | 23:1111ee8bcba4 | 635 | /* Codes_SRS_AMQP_MANAGEMENT_01_085: [ For each of the arguments `operation`, `type` and `locales` an AMQP value of type string containing the argument value shall be created by calling `amqpvalue_create_string` in order to be used as value in the application properties map. ]*/ |
AzureIoTClient | 6:641a9672db08 | 636 | AMQP_VALUE value_value = amqpvalue_create_string(value); |
AzureIoTClient | 6:641a9672db08 | 637 | if (value_value == NULL) |
AzureIoTClient | 6:641a9672db08 | 638 | { |
AzureIoTClient | 23:1111ee8bcba4 | 639 | /* Codes_SRS_AMQP_MANAGEMENT_01_090: [ If any APIs used to create and set the application properties on the message fails, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 640 | LogError("Could not create value for key %s", key); |
AzureIoTClient | 19:000ab4e6a2c1 | 641 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 642 | } |
AzureIoTClient | 6:641a9672db08 | 643 | else |
AzureIoTClient | 6:641a9672db08 | 644 | { |
AzureIoTClient | 23:1111ee8bcba4 | 645 | /* Codes_SRS_AMQP_MANAGEMENT_01_086: [ The key/value pairs for `operation`, `type` and `locales` shall be added to the application properties map by calling `amqpvalue_set_map_value`. ]*/ |
AzureIoTClient | 6:641a9672db08 | 646 | if (amqpvalue_set_map_value(map, key_value, value_value) != 0) |
AzureIoTClient | 6:641a9672db08 | 647 | { |
AzureIoTClient | 23:1111ee8bcba4 | 648 | /* Codes_SRS_AMQP_MANAGEMENT_01_090: [ If any APIs used to create and set the application properties on the message fails, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 649 | LogError("Could not set the value in the map for key %s", key); |
AzureIoTClient | 19:000ab4e6a2c1 | 650 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 651 | } |
AzureIoTClient | 6:641a9672db08 | 652 | else |
AzureIoTClient | 6:641a9672db08 | 653 | { |
AzureIoTClient | 6:641a9672db08 | 654 | result = 0; |
AzureIoTClient | 6:641a9672db08 | 655 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 656 | |
AzureIoTClient | 23:1111ee8bcba4 | 657 | amqpvalue_destroy(value_value); |
AzureIoTClient | 6:641a9672db08 | 658 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 659 | |
AzureIoTClient | 23:1111ee8bcba4 | 660 | amqpvalue_destroy(key_value); |
AzureIoTClient | 6:641a9672db08 | 661 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 662 | |
AzureIoTClient | 6:641a9672db08 | 663 | return result; |
Azure.IoT Build | 0:6ae2f7bca550 | 664 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 665 | |
AzureIoTClient | 39:e7c983378f41 | 666 | static int internal_set_status_code_key_name(AMQP_MANAGEMENT_HANDLE amqp_management, const char* status_code_key_name) |
AzureIoTClient | 39:e7c983378f41 | 667 | { |
AzureIoTClient | 39:e7c983378f41 | 668 | int result; |
AzureIoTClient | 39:e7c983378f41 | 669 | char* copied_status_code_key_name; |
AzureIoTClient | 39:e7c983378f41 | 670 | if (mallocAndStrcpy_s(&copied_status_code_key_name, status_code_key_name) != 0) |
AzureIoTClient | 39:e7c983378f41 | 671 | { |
AzureIoTClient | 39:e7c983378f41 | 672 | LogError("Cannot copy status code key name"); |
AzureIoTClient | 39:e7c983378f41 | 673 | result = __FAILURE__; |
AzureIoTClient | 39:e7c983378f41 | 674 | } |
AzureIoTClient | 39:e7c983378f41 | 675 | else |
AzureIoTClient | 39:e7c983378f41 | 676 | { |
AzureIoTClient | 39:e7c983378f41 | 677 | if (amqp_management->status_code_key_name != NULL) |
AzureIoTClient | 39:e7c983378f41 | 678 | { |
AzureIoTClient | 39:e7c983378f41 | 679 | free(amqp_management->status_code_key_name); |
AzureIoTClient | 39:e7c983378f41 | 680 | } |
AzureIoTClient | 39:e7c983378f41 | 681 | |
AzureIoTClient | 39:e7c983378f41 | 682 | amqp_management->status_code_key_name = copied_status_code_key_name; |
AzureIoTClient | 39:e7c983378f41 | 683 | result = 0; |
AzureIoTClient | 39:e7c983378f41 | 684 | } |
AzureIoTClient | 39:e7c983378f41 | 685 | |
AzureIoTClient | 39:e7c983378f41 | 686 | return result; |
AzureIoTClient | 39:e7c983378f41 | 687 | } |
AzureIoTClient | 39:e7c983378f41 | 688 | |
AzureIoTClient | 39:e7c983378f41 | 689 | static int internal_set_status_description_key_name(AMQP_MANAGEMENT_HANDLE amqp_management, const char* status_description_key_name) |
AzureIoTClient | 39:e7c983378f41 | 690 | { |
AzureIoTClient | 39:e7c983378f41 | 691 | int result; |
AzureIoTClient | 39:e7c983378f41 | 692 | char* copied_status_description_key_name; |
AzureIoTClient | 39:e7c983378f41 | 693 | if (mallocAndStrcpy_s(&copied_status_description_key_name, status_description_key_name) != 0) |
AzureIoTClient | 39:e7c983378f41 | 694 | { |
AzureIoTClient | 39:e7c983378f41 | 695 | LogError("Cannot copy status description key name"); |
AzureIoTClient | 39:e7c983378f41 | 696 | result = __FAILURE__; |
AzureIoTClient | 39:e7c983378f41 | 697 | } |
AzureIoTClient | 39:e7c983378f41 | 698 | else |
AzureIoTClient | 39:e7c983378f41 | 699 | { |
AzureIoTClient | 39:e7c983378f41 | 700 | if (amqp_management->status_description_key_name != NULL) |
AzureIoTClient | 39:e7c983378f41 | 701 | { |
AzureIoTClient | 39:e7c983378f41 | 702 | free(amqp_management->status_description_key_name); |
AzureIoTClient | 39:e7c983378f41 | 703 | } |
AzureIoTClient | 39:e7c983378f41 | 704 | |
AzureIoTClient | 39:e7c983378f41 | 705 | amqp_management->status_description_key_name = copied_status_description_key_name; |
AzureIoTClient | 39:e7c983378f41 | 706 | result = 0; |
AzureIoTClient | 39:e7c983378f41 | 707 | } |
AzureIoTClient | 39:e7c983378f41 | 708 | |
AzureIoTClient | 39:e7c983378f41 | 709 | return result; |
AzureIoTClient | 39:e7c983378f41 | 710 | } |
AzureIoTClient | 39:e7c983378f41 | 711 | |
AzureIoTClient | 22:524bded3f7a8 | 712 | AMQP_MANAGEMENT_HANDLE amqp_management_create(SESSION_HANDLE session, const char* management_node) |
Azure.IoT Build | 0:6ae2f7bca550 | 713 | { |
AzureIoTClient | 39:e7c983378f41 | 714 | AMQP_MANAGEMENT_INSTANCE* amqp_management; |
Azure.IoT Build | 0:6ae2f7bca550 | 715 | |
AzureIoTClient | 23:1111ee8bcba4 | 716 | if ((session == NULL) || |
AzureIoTClient | 23:1111ee8bcba4 | 717 | (management_node == NULL)) |
AzureIoTClient | 6:641a9672db08 | 718 | { |
AzureIoTClient | 23:1111ee8bcba4 | 719 | /* Codes_SRS_AMQP_MANAGEMENT_01_002: [ If `session` or `management_node` is NULL then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 720 | LogError("Bad arguments: session = %p, management_node = %p", session, management_node); |
AzureIoTClient | 39:e7c983378f41 | 721 | amqp_management = NULL; |
AzureIoTClient | 23:1111ee8bcba4 | 722 | } |
AzureIoTClient | 23:1111ee8bcba4 | 723 | else if (strlen(management_node) == 0) |
AzureIoTClient | 23:1111ee8bcba4 | 724 | { |
AzureIoTClient | 23:1111ee8bcba4 | 725 | /* Codes_SRS_AMQP_MANAGEMENT_01_030: [ If `management_node` is an empty string, then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 726 | LogError("Empty string management node"); |
AzureIoTClient | 39:e7c983378f41 | 727 | amqp_management = NULL; |
AzureIoTClient | 6:641a9672db08 | 728 | } |
AzureIoTClient | 6:641a9672db08 | 729 | else |
AzureIoTClient | 6:641a9672db08 | 730 | { |
AzureIoTClient | 23:1111ee8bcba4 | 731 | /* Codes_SRS_AMQP_MANAGEMENT_01_001: [ `amqp_management_create` shall create a new CBS instance and on success return a non-NULL handle to it. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 732 | amqp_management = (AMQP_MANAGEMENT_INSTANCE*)malloc(sizeof(AMQP_MANAGEMENT_INSTANCE)); |
AzureIoTClient | 39:e7c983378f41 | 733 | if (amqp_management == NULL) |
AzureIoTClient | 6:641a9672db08 | 734 | { |
AzureIoTClient | 23:1111ee8bcba4 | 735 | /* Codes_SRS_AMQP_MANAGEMENT_01_005: [ If allocating memory for the new handle fails, `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 736 | LogError("Cannot allocate memory for AMQP management handle"); |
AzureIoTClient | 23:1111ee8bcba4 | 737 | } |
AzureIoTClient | 23:1111ee8bcba4 | 738 | else |
AzureIoTClient | 23:1111ee8bcba4 | 739 | { |
AzureIoTClient | 39:e7c983378f41 | 740 | amqp_management->sender_connected = 0; |
AzureIoTClient | 39:e7c983378f41 | 741 | amqp_management->receiver_connected = 0; |
AzureIoTClient | 39:e7c983378f41 | 742 | amqp_management->on_amqp_management_open_complete = NULL; |
AzureIoTClient | 39:e7c983378f41 | 743 | amqp_management->on_amqp_management_open_complete_context = NULL; |
AzureIoTClient | 39:e7c983378f41 | 744 | amqp_management->on_amqp_management_error = NULL; |
AzureIoTClient | 39:e7c983378f41 | 745 | amqp_management->on_amqp_management_error_context = NULL; |
AzureIoTClient | 39:e7c983378f41 | 746 | amqp_management->amqp_management_state = AMQP_MANAGEMENT_STATE_IDLE; |
AzureIoTClient | 39:e7c983378f41 | 747 | amqp_management->status_code_key_name = NULL; |
AzureIoTClient | 39:e7c983378f41 | 748 | amqp_management->status_description_key_name = NULL; |
Azure.IoT Build | 0:6ae2f7bca550 | 749 | |
AzureIoTClient | 23:1111ee8bcba4 | 750 | /* Codes_SRS_AMQP_MANAGEMENT_01_003: [ `amqp_management_create` shall create a singly linked list for pending operations by calling `singlylinkedlist_create`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 751 | amqp_management->pending_operations = singlylinkedlist_create(); |
AzureIoTClient | 39:e7c983378f41 | 752 | if (amqp_management->pending_operations == NULL) |
AzureIoTClient | 6:641a9672db08 | 753 | { |
AzureIoTClient | 23:1111ee8bcba4 | 754 | /* Codes_SRS_AMQP_MANAGEMENT_01_004: [ If `singlylinkedlist_create` fails, `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 755 | LogError("Cannot create pending operations list"); |
AzureIoTClient | 6:641a9672db08 | 756 | } |
AzureIoTClient | 6:641a9672db08 | 757 | else |
AzureIoTClient | 6:641a9672db08 | 758 | { |
AzureIoTClient | 39:e7c983378f41 | 759 | /* Codes_SRS_AMQP_MANAGEMENT_01_181: [ `amqp_management_create` shall set the status code key name to be used for parsing the status code to `statusCode`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 760 | if (internal_set_status_code_key_name(amqp_management, "statusCode") != 0) |
AzureIoTClient | 6:641a9672db08 | 761 | { |
AzureIoTClient | 39:e7c983378f41 | 762 | LogError("Cannot set status code key name"); |
AzureIoTClient | 6:641a9672db08 | 763 | } |
AzureIoTClient | 6:641a9672db08 | 764 | else |
AzureIoTClient | 6:641a9672db08 | 765 | { |
AzureIoTClient | 39:e7c983378f41 | 766 | /* Codes_SRS_AMQP_MANAGEMENT_01_182: [ `amqp_management_create` shall set the status description key name to be used for parsing the status description to `statusDescription`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 767 | if (internal_set_status_description_key_name(amqp_management, "statusDescription") != 0) |
AzureIoTClient | 6:641a9672db08 | 768 | { |
AzureIoTClient | 39:e7c983378f41 | 769 | LogError("Cannot set status description key name"); |
AzureIoTClient | 6:641a9672db08 | 770 | } |
AzureIoTClient | 6:641a9672db08 | 771 | else |
AzureIoTClient | 6:641a9672db08 | 772 | { |
AzureIoTClient | 39:e7c983378f41 | 773 | /* Codes_SRS_AMQP_MANAGEMENT_01_010: [ The `source` argument shall be a value created by calling `messaging_create_source` with `management_node` as argument. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 774 | AMQP_VALUE source = messaging_create_source(management_node); |
AzureIoTClient | 39:e7c983378f41 | 775 | if (source == NULL) |
AzureIoTClient | 6:641a9672db08 | 776 | { |
AzureIoTClient | 39:e7c983378f41 | 777 | /* Codes_SRS_AMQP_MANAGEMENT_01_012: [ If `messaging_create_source` fails then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 778 | LogError("Failed creating source AMQP value"); |
AzureIoTClient | 6:641a9672db08 | 779 | } |
AzureIoTClient | 6:641a9672db08 | 780 | else |
AzureIoTClient | 6:641a9672db08 | 781 | { |
AzureIoTClient | 39:e7c983378f41 | 782 | /* Codes_SRS_AMQP_MANAGEMENT_01_011: [ The `target` argument shall be a value created by calling `messaging_create_target` with `management_node` as argument. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 783 | AMQP_VALUE target = messaging_create_target(management_node); |
AzureIoTClient | 39:e7c983378f41 | 784 | if (target == NULL) |
AzureIoTClient | 6:641a9672db08 | 785 | { |
AzureIoTClient | 39:e7c983378f41 | 786 | /* Codes_SRS_AMQP_MANAGEMENT_01_013: [ If `messaging_create_target` fails then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 787 | LogError("Failed creating target AMQP value"); |
AzureIoTClient | 6:641a9672db08 | 788 | } |
AzureIoTClient | 6:641a9672db08 | 789 | else |
AzureIoTClient | 6:641a9672db08 | 790 | { |
AzureIoTClient | 39:e7c983378f41 | 791 | size_t management_node_length = strlen(management_node); |
AzureIoTClient | 23:1111ee8bcba4 | 792 | |
AzureIoTClient | 39:e7c983378f41 | 793 | char* sender_link_name = (char*)malloc(management_node_length + COUNT_CHARS(sender_suffix) + 1); |
AzureIoTClient | 39:e7c983378f41 | 794 | if (sender_link_name == NULL) |
AzureIoTClient | 6:641a9672db08 | 795 | { |
AzureIoTClient | 39:e7c983378f41 | 796 | /* Codes_SRS_AMQP_MANAGEMENT_01_033: [ If any other error occurs `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 797 | LogError("Failed allocating memory for sender link name"); |
AzureIoTClient | 6:641a9672db08 | 798 | } |
AzureIoTClient | 6:641a9672db08 | 799 | else |
AzureIoTClient | 6:641a9672db08 | 800 | { |
AzureIoTClient | 39:e7c983378f41 | 801 | char* receiver_link_name; |
AzureIoTClient | 39:e7c983378f41 | 802 | |
AzureIoTClient | 39:e7c983378f41 | 803 | (void)memcpy(sender_link_name, management_node, management_node_length); |
AzureIoTClient | 39:e7c983378f41 | 804 | (void)memcpy(sender_link_name + management_node_length, sender_suffix, COUNT_CHARS(sender_suffix) + 1); |
AzureIoTClient | 39:e7c983378f41 | 805 | |
AzureIoTClient | 39:e7c983378f41 | 806 | receiver_link_name = (char*)malloc(management_node_length + COUNT_CHARS(receiver_suffix) + 1); |
AzureIoTClient | 39:e7c983378f41 | 807 | if (receiver_link_name == NULL) |
AzureIoTClient | 6:641a9672db08 | 808 | { |
AzureIoTClient | 39:e7c983378f41 | 809 | /* Codes_SRS_AMQP_MANAGEMENT_01_033: [ If any other error occurs `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 810 | LogError("Failed allocating memory for receiver link name"); |
AzureIoTClient | 6:641a9672db08 | 811 | } |
AzureIoTClient | 6:641a9672db08 | 812 | else |
AzureIoTClient | 6:641a9672db08 | 813 | { |
AzureIoTClient | 39:e7c983378f41 | 814 | (void)memcpy(receiver_link_name, management_node, management_node_length); |
AzureIoTClient | 39:e7c983378f41 | 815 | (void)memcpy(receiver_link_name + management_node_length, receiver_suffix, COUNT_CHARS(receiver_suffix) + 1); |
AzureIoTClient | 39:e7c983378f41 | 816 | |
AzureIoTClient | 39:e7c983378f41 | 817 | /* Codes_SRS_AMQP_MANAGEMENT_01_006: [ `amqp_management_create` shall create a sender link by calling `link_create`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 818 | /* Codes_SRS_AMQP_MANAGEMENT_01_007: [ The `session` argument shall be set to `session`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 819 | /* Codes_SRS_AMQP_MANAGEMENT_01_008: [ The `name` argument shall be constructed by concatenating the `management_node` value with `-sender`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 820 | /* Codes_SRS_AMQP_MANAGEMENT_01_009: [ The `role` argument shall be `role_sender`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 821 | /* Codes_SRS_AMQP_MANAGEMENT_01_019: [ The `source` argument shall be the value created by calling `messaging_create_source`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 822 | /* Codes_SRS_AMQP_MANAGEMENT_01_020: [ The `target` argument shall be the value created by calling `messaging_create_target`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 823 | amqp_management->sender_link = link_create(session, sender_link_name, role_sender, source, target); |
AzureIoTClient | 39:e7c983378f41 | 824 | if (amqp_management->sender_link == NULL) |
AzureIoTClient | 6:641a9672db08 | 825 | { |
AzureIoTClient | 39:e7c983378f41 | 826 | /* Codes_SRS_AMQP_MANAGEMENT_01_014: [ If `link_create` fails when creating the sender link then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 827 | LogError("Failed creating sender link"); |
AzureIoTClient | 6:641a9672db08 | 828 | } |
AzureIoTClient | 6:641a9672db08 | 829 | else |
AzureIoTClient | 6:641a9672db08 | 830 | { |
AzureIoTClient | 39:e7c983378f41 | 831 | /* Codes_SRS_AMQP_MANAGEMENT_01_015: [ `amqp_management_create` shall create a receiver link by calling `link_create`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 832 | /* Codes_SRS_AMQP_MANAGEMENT_01_016: [ The `session` argument shall be set to `session`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 833 | /* Codes_SRS_AMQP_MANAGEMENT_01_017: [ The `name` argument shall be constructed by concatenating the `management_node` value with `-receiver`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 834 | /* Codes_SRS_AMQP_MANAGEMENT_01_018: [ The `role` argument shall be `role_receiver`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 835 | /* Codes_SRS_AMQP_MANAGEMENT_01_019: [ The `source` argument shall be the value created by calling `messaging_create_source`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 836 | /* Codes_SRS_AMQP_MANAGEMENT_01_020: [ The `target` argument shall be the value created by calling `messaging_create_target`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 837 | amqp_management->receiver_link = link_create(session, receiver_link_name, role_receiver, source, target); |
AzureIoTClient | 39:e7c983378f41 | 838 | if (amqp_management->receiver_link == NULL) |
AzureIoTClient | 6:641a9672db08 | 839 | { |
AzureIoTClient | 39:e7c983378f41 | 840 | /* Codes_SRS_AMQP_MANAGEMENT_01_021: [ If `link_create` fails when creating the receiver link then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 841 | LogError("Failed creating receiver link"); |
AzureIoTClient | 6:641a9672db08 | 842 | } |
AzureIoTClient | 6:641a9672db08 | 843 | else |
AzureIoTClient | 6:641a9672db08 | 844 | { |
AzureIoTClient | 39:e7c983378f41 | 845 | /* Codes_SRS_AMQP_MANAGEMENT_01_022: [ `amqp_management_create` shall create a message sender by calling `messagesender_create` and passing to it the sender link handle. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 846 | amqp_management->message_sender = messagesender_create(amqp_management->sender_link, on_message_sender_state_changed, amqp_management); |
AzureIoTClient | 39:e7c983378f41 | 847 | if (amqp_management->message_sender == NULL) |
AzureIoTClient | 39:e7c983378f41 | 848 | { |
AzureIoTClient | 39:e7c983378f41 | 849 | /* Codes_SRS_AMQP_MANAGEMENT_01_031: [ If `messagesender_create` fails then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 850 | LogError("Failed creating message sender"); |
AzureIoTClient | 39:e7c983378f41 | 851 | } |
AzureIoTClient | 39:e7c983378f41 | 852 | else |
AzureIoTClient | 39:e7c983378f41 | 853 | { |
AzureIoTClient | 39:e7c983378f41 | 854 | /* Codes_SRS_AMQP_MANAGEMENT_01_023: [ `amqp_management_create` shall create a message receiver by calling `messagereceiver_create` and passing to it the receiver link handle. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 855 | amqp_management->message_receiver = messagereceiver_create(amqp_management->receiver_link, on_message_receiver_state_changed, amqp_management); |
AzureIoTClient | 39:e7c983378f41 | 856 | if (amqp_management->message_receiver == NULL) |
AzureIoTClient | 39:e7c983378f41 | 857 | { |
AzureIoTClient | 39:e7c983378f41 | 858 | /* Codes_SRS_AMQP_MANAGEMENT_01_032: [ If `messagereceiver_create` fails then `amqp_management_create` shall fail and return NULL. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 859 | LogError("Failed creating message receiver"); |
AzureIoTClient | 39:e7c983378f41 | 860 | link_destroy(amqp_management->receiver_link); |
AzureIoTClient | 39:e7c983378f41 | 861 | } |
AzureIoTClient | 39:e7c983378f41 | 862 | else |
AzureIoTClient | 39:e7c983378f41 | 863 | { |
AzureIoTClient | 39:e7c983378f41 | 864 | free(receiver_link_name); |
AzureIoTClient | 39:e7c983378f41 | 865 | free(sender_link_name); |
AzureIoTClient | 39:e7c983378f41 | 866 | amqpvalue_destroy(target); |
AzureIoTClient | 39:e7c983378f41 | 867 | amqpvalue_destroy(source); |
AzureIoTClient | 39:e7c983378f41 | 868 | |
AzureIoTClient | 39:e7c983378f41 | 869 | /* Codes_SRS_AMQP_MANAGEMENT_01_106: [ The message Id set on the message properties shall start at 0. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 870 | amqp_management->next_message_id = 0; |
AzureIoTClient | 39:e7c983378f41 | 871 | |
AzureIoTClient | 39:e7c983378f41 | 872 | goto all_ok; |
AzureIoTClient | 39:e7c983378f41 | 873 | } |
AzureIoTClient | 39:e7c983378f41 | 874 | |
AzureIoTClient | 39:e7c983378f41 | 875 | messagesender_destroy(amqp_management->message_sender); |
AzureIoTClient | 39:e7c983378f41 | 876 | } |
AzureIoTClient | 39:e7c983378f41 | 877 | |
AzureIoTClient | 39:e7c983378f41 | 878 | link_destroy(amqp_management->receiver_link); |
AzureIoTClient | 6:641a9672db08 | 879 | } |
AzureIoTClient | 39:e7c983378f41 | 880 | |
AzureIoTClient | 39:e7c983378f41 | 881 | link_destroy(amqp_management->sender_link); |
AzureIoTClient | 6:641a9672db08 | 882 | } |
AzureIoTClient | 39:e7c983378f41 | 883 | |
AzureIoTClient | 39:e7c983378f41 | 884 | free(receiver_link_name); |
AzureIoTClient | 6:641a9672db08 | 885 | } |
AzureIoTClient | 39:e7c983378f41 | 886 | |
AzureIoTClient | 39:e7c983378f41 | 887 | free(sender_link_name); |
AzureIoTClient | 6:641a9672db08 | 888 | } |
AzureIoTClient | 23:1111ee8bcba4 | 889 | |
AzureIoTClient | 39:e7c983378f41 | 890 | amqpvalue_destroy(target); |
AzureIoTClient | 6:641a9672db08 | 891 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 892 | |
AzureIoTClient | 39:e7c983378f41 | 893 | amqpvalue_destroy(source); |
AzureIoTClient | 6:641a9672db08 | 894 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 895 | |
AzureIoTClient | 39:e7c983378f41 | 896 | free(amqp_management->status_description_key_name); |
AzureIoTClient | 6:641a9672db08 | 897 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 898 | |
AzureIoTClient | 39:e7c983378f41 | 899 | free(amqp_management->status_code_key_name); |
AzureIoTClient | 6:641a9672db08 | 900 | } |
AzureIoTClient | 39:e7c983378f41 | 901 | |
AzureIoTClient | 39:e7c983378f41 | 902 | singlylinkedlist_destroy(amqp_management->pending_operations); |
AzureIoTClient | 6:641a9672db08 | 903 | } |
AzureIoTClient | 39:e7c983378f41 | 904 | |
AzureIoTClient | 39:e7c983378f41 | 905 | free(amqp_management); |
AzureIoTClient | 39:e7c983378f41 | 906 | amqp_management = NULL; |
AzureIoTClient | 6:641a9672db08 | 907 | } |
AzureIoTClient | 6:641a9672db08 | 908 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 909 | |
AzureIoTClient | 39:e7c983378f41 | 910 | all_ok: |
AzureIoTClient | 39:e7c983378f41 | 911 | return amqp_management; |
Azure.IoT Build | 0:6ae2f7bca550 | 912 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 913 | |
AzureIoTClient | 22:524bded3f7a8 | 914 | void amqp_management_destroy(AMQP_MANAGEMENT_HANDLE amqp_management) |
Azure.IoT Build | 0:6ae2f7bca550 | 915 | { |
AzureIoTClient | 23:1111ee8bcba4 | 916 | if (amqp_management == NULL) |
AzureIoTClient | 6:641a9672db08 | 917 | { |
AzureIoTClient | 23:1111ee8bcba4 | 918 | /* Codes_SRS_AMQP_MANAGEMENT_01_025: [ If `amqp_management` is NULL, `amqp_management_destroy` shall do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 919 | LogError("NULL amqp_management"); |
AzureIoTClient | 23:1111ee8bcba4 | 920 | } |
AzureIoTClient | 23:1111ee8bcba4 | 921 | else |
AzureIoTClient | 23:1111ee8bcba4 | 922 | { |
AzureIoTClient | 23:1111ee8bcba4 | 923 | /* Codes_SRS_AMQP_MANAGEMENT_01_024: [ `amqp_management_destroy` shall free all the resources allocated by `amqp_management_create`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 924 | if (amqp_management->amqp_management_state != AMQP_MANAGEMENT_STATE_IDLE) |
AzureIoTClient | 6:641a9672db08 | 925 | { |
AzureIoTClient | 23:1111ee8bcba4 | 926 | (void)amqp_management_close(amqp_management); |
AzureIoTClient | 6:641a9672db08 | 927 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 928 | |
AzureIoTClient | 23:1111ee8bcba4 | 929 | /* Codes_SRS_AMQP_MANAGEMENT_01_028: [ `amqp_management_destroy` shall free the message sender by calling `messagesender_destroy`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 930 | messagesender_destroy(amqp_management->message_sender); |
AzureIoTClient | 23:1111ee8bcba4 | 931 | /* Codes_SRS_AMQP_MANAGEMENT_01_029: [ `amqp_management_destroy` shall free the message receiver by calling `messagereceiver_destroy`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 932 | messagereceiver_destroy(amqp_management->message_receiver); |
AzureIoTClient | 23:1111ee8bcba4 | 933 | /* Codes_SRS_AMQP_MANAGEMENT_01_027: [ `amqp_management_destroy` shall free the sender and receiver links by calling `link_destroy`. ]*/ |
AzureIoTClient | 6:641a9672db08 | 934 | link_destroy(amqp_management->sender_link); |
AzureIoTClient | 6:641a9672db08 | 935 | link_destroy(amqp_management->receiver_link); |
AzureIoTClient | 39:e7c983378f41 | 936 | free(amqp_management->status_code_key_name); |
AzureIoTClient | 39:e7c983378f41 | 937 | free(amqp_management->status_description_key_name); |
AzureIoTClient | 23:1111ee8bcba4 | 938 | /* Codes_SRS_AMQP_MANAGEMENT_01_026: [ `amqp_management_destroy` shall free the singly linked list by calling `singlylinkedlist_destroy`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 939 | singlylinkedlist_destroy(amqp_management->pending_operations); |
AzureIoTClient | 21:f9c433d8e6ca | 940 | free(amqp_management); |
AzureIoTClient | 6:641a9672db08 | 941 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 942 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 943 | |
AzureIoTClient | 22:524bded3f7a8 | 944 | int amqp_management_open_async(AMQP_MANAGEMENT_HANDLE amqp_management, ON_AMQP_MANAGEMENT_OPEN_COMPLETE on_amqp_management_open_complete, void* on_amqp_management_open_complete_context, ON_AMQP_MANAGEMENT_ERROR on_amqp_management_error, void* on_amqp_management_error_context) |
Azure.IoT Build | 0:6ae2f7bca550 | 945 | { |
AzureIoTClient | 6:641a9672db08 | 946 | int result; |
Azure.IoT Build | 0:6ae2f7bca550 | 947 | |
AzureIoTClient | 23:1111ee8bcba4 | 948 | /* Codes_SRS_AMQP_MANAGEMENT_01_044: [ `on_amqp_management_open_complete_context` and `on_amqp_management_error_context` shall be allowed to be NULL. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 949 | if ((amqp_management == NULL) || |
AzureIoTClient | 23:1111ee8bcba4 | 950 | (on_amqp_management_open_complete == NULL) || |
AzureIoTClient | 23:1111ee8bcba4 | 951 | (on_amqp_management_error == NULL)) |
AzureIoTClient | 6:641a9672db08 | 952 | { |
AzureIoTClient | 23:1111ee8bcba4 | 953 | /* Codes_SRS_AMQP_MANAGEMENT_01_038: [ If `amqp_management`, `on_amqp_management_open_complete` or `on_amqp_management_error` is NULL, `amqp_management_open_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 954 | LogError("Bad arguments: amqp_management = %p, on_amqp_management_open_complete = %p, on_amqp_management_error = %p", |
AzureIoTClient | 23:1111ee8bcba4 | 955 | amqp_management, |
AzureIoTClient | 23:1111ee8bcba4 | 956 | on_amqp_management_open_complete, |
AzureIoTClient | 23:1111ee8bcba4 | 957 | on_amqp_management_error); |
AzureIoTClient | 23:1111ee8bcba4 | 958 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 959 | } |
AzureIoTClient | 23:1111ee8bcba4 | 960 | else if (amqp_management->amqp_management_state != AMQP_MANAGEMENT_STATE_IDLE) |
AzureIoTClient | 23:1111ee8bcba4 | 961 | { |
AzureIoTClient | 23:1111ee8bcba4 | 962 | /* Codes_SRS_AMQP_MANAGEMENT_01_043: [ If the AMQP management instance is already OPEN or OPENING, `amqp_management_open_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 963 | LogError("AMQP management instance already OPEN"); |
AzureIoTClient | 19:000ab4e6a2c1 | 964 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 965 | } |
AzureIoTClient | 6:641a9672db08 | 966 | else |
AzureIoTClient | 6:641a9672db08 | 967 | { |
AzureIoTClient | 23:1111ee8bcba4 | 968 | /* Codes_SRS_AMQP_MANAGEMENT_01_036: [ `amqp_management_open_async` shall start opening the AMQP management instance and save the callbacks so that they can be called when opening is complete. ]*/ |
AzureIoTClient | 22:524bded3f7a8 | 969 | amqp_management->on_amqp_management_open_complete = on_amqp_management_open_complete; |
AzureIoTClient | 22:524bded3f7a8 | 970 | amqp_management->on_amqp_management_open_complete_context = on_amqp_management_open_complete_context; |
AzureIoTClient | 22:524bded3f7a8 | 971 | amqp_management->on_amqp_management_error = on_amqp_management_error; |
AzureIoTClient | 22:524bded3f7a8 | 972 | amqp_management->on_amqp_management_error_context = on_amqp_management_error_context; |
AzureIoTClient | 22:524bded3f7a8 | 973 | amqp_management->amqp_management_state = AMQP_MANAGEMENT_STATE_OPENING; |
AzureIoTClient | 22:524bded3f7a8 | 974 | |
AzureIoTClient | 23:1111ee8bcba4 | 975 | /* Codes_SRS_AMQP_MANAGEMENT_01_040: [ `amqp_management_open_async` shall open the message receiver by calling `messagereceiver_open`. ]*/ |
AzureIoTClient | 6:641a9672db08 | 976 | if (messagereceiver_open(amqp_management->message_receiver, on_message_received, amqp_management) != 0) |
AzureIoTClient | 6:641a9672db08 | 977 | { |
AzureIoTClient | 23:1111ee8bcba4 | 978 | /* Codes_SRS_AMQP_MANAGEMENT_01_042: [ If `messagereceiver_open` fails, `amqp_management_open_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 979 | LogError("Failed opening message receiver"); |
AzureIoTClient | 22:524bded3f7a8 | 980 | amqp_management->amqp_management_state = AMQP_MANAGEMENT_STATE_IDLE; |
AzureIoTClient | 19:000ab4e6a2c1 | 981 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 982 | } |
AzureIoTClient | 6:641a9672db08 | 983 | else |
AzureIoTClient | 6:641a9672db08 | 984 | { |
AzureIoTClient | 23:1111ee8bcba4 | 985 | /* Codes_SRS_AMQP_MANAGEMENT_01_039: [ `amqp_management_open_async` shall open the message sender by calling `messagesender_open`. ]*/ |
AzureIoTClient | 6:641a9672db08 | 986 | if (messagesender_open(amqp_management->message_sender) != 0) |
AzureIoTClient | 6:641a9672db08 | 987 | { |
AzureIoTClient | 23:1111ee8bcba4 | 988 | /* Codes_SRS_AMQP_MANAGEMENT_01_041: [ If `messagesender_open` fails, `amqp_management_open_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 989 | LogError("Failed opening message sender"); |
AzureIoTClient | 22:524bded3f7a8 | 990 | amqp_management->amqp_management_state = AMQP_MANAGEMENT_STATE_IDLE; |
AzureIoTClient | 23:1111ee8bcba4 | 991 | (void)messagereceiver_close(amqp_management->message_receiver); |
AzureIoTClient | 19:000ab4e6a2c1 | 992 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 993 | } |
AzureIoTClient | 6:641a9672db08 | 994 | else |
AzureIoTClient | 6:641a9672db08 | 995 | { |
AzureIoTClient | 23:1111ee8bcba4 | 996 | /* Codes_SRS_AMQP_MANAGEMENT_01_037: [ On success it shall return 0. ]*/ |
AzureIoTClient | 6:641a9672db08 | 997 | result = 0; |
AzureIoTClient | 6:641a9672db08 | 998 | } |
AzureIoTClient | 6:641a9672db08 | 999 | } |
AzureIoTClient | 6:641a9672db08 | 1000 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1001 | |
AzureIoTClient | 6:641a9672db08 | 1002 | return result; |
Azure.IoT Build | 0:6ae2f7bca550 | 1003 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1004 | |
AzureIoTClient | 22:524bded3f7a8 | 1005 | int amqp_management_close(AMQP_MANAGEMENT_HANDLE amqp_management) |
Azure.IoT Build | 0:6ae2f7bca550 | 1006 | { |
AzureIoTClient | 6:641a9672db08 | 1007 | int result; |
Azure.IoT Build | 0:6ae2f7bca550 | 1008 | |
AzureIoTClient | 6:641a9672db08 | 1009 | if (amqp_management == NULL) |
AzureIoTClient | 6:641a9672db08 | 1010 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1011 | /* Codes_SRS_AMQP_MANAGEMENT_01_047: [ If `amqp_management` is NULL, `amqp_management_close` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1012 | LogError("NULL amqp_management"); |
AzureIoTClient | 23:1111ee8bcba4 | 1013 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 1014 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1015 | else if (amqp_management->amqp_management_state == AMQP_MANAGEMENT_STATE_IDLE) |
AzureIoTClient | 23:1111ee8bcba4 | 1016 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1017 | /* Codes_SRS_AMQP_MANAGEMENT_01_049: [ `amqp_management_close` on an AMQP management instance that is not OPEN, shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1018 | LogError("AMQP management instance not open"); |
AzureIoTClient | 19:000ab4e6a2c1 | 1019 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1020 | } |
AzureIoTClient | 6:641a9672db08 | 1021 | else |
AzureIoTClient | 6:641a9672db08 | 1022 | { |
AzureIoTClient | 41:0e723f9cbd89 | 1023 | AMQP_MANAGEMENT_STATE previous_state = amqp_management->amqp_management_state; |
AzureIoTClient | 41:0e723f9cbd89 | 1024 | |
AzureIoTClient | 41:0e723f9cbd89 | 1025 | amqp_management->amqp_management_state = AMQP_MANAGEMENT_STATE_CLOSING; |
AzureIoTClient | 41:0e723f9cbd89 | 1026 | |
AzureIoTClient | 41:0e723f9cbd89 | 1027 | if (previous_state == AMQP_MANAGEMENT_STATE_OPENING) |
AzureIoTClient | 41:0e723f9cbd89 | 1028 | { |
AzureIoTClient | 41:0e723f9cbd89 | 1029 | /* Codes_SRS_AMQP_MANAGEMENT_01_048: [ `amqp_management_close` on an AMQP management instance that is OPENING shall trigger the `on_amqp_management_open_complete` callback with `AMQP_MANAGEMENT_OPEN_CANCELLED`, while also passing the context passed in `amqp_management_open_async`. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 1030 | amqp_management->on_amqp_management_open_complete(amqp_management->on_amqp_management_open_complete_context, AMQP_MANAGEMENT_OPEN_CANCELLED); |
AzureIoTClient | 41:0e723f9cbd89 | 1031 | } |
AzureIoTClient | 41:0e723f9cbd89 | 1032 | |
AzureIoTClient | 41:0e723f9cbd89 | 1033 | |
AzureIoTClient | 23:1111ee8bcba4 | 1034 | /* Codes_SRS_AMQP_MANAGEMENT_01_045: [ `amqp_management_close` shall close the AMQP management instance. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1035 | /* Codes_SRS_AMQP_MANAGEMENT_01_050: [ `amqp_management_close` shall close the message sender by calling `messagesender_close`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1036 | if (messagesender_close(amqp_management->message_sender) != 0) |
AzureIoTClient | 6:641a9672db08 | 1037 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1038 | /* Codes_SRS_AMQP_MANAGEMENT_01_052: [ If `messagesender_close` fails, `amqp_management_close` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1039 | LogError("messagesender_close failed"); |
AzureIoTClient | 23:1111ee8bcba4 | 1040 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 1041 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1042 | /* Codes_SRS_AMQP_MANAGEMENT_01_051: [ `amqp_management_close` shall close the message receiver by calling `messagereceiver_close`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1043 | else if (messagereceiver_close(amqp_management->message_receiver) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 1044 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1045 | /* Codes_SRS_AMQP_MANAGEMENT_01_053: [ If `messagereceiver_close` fails, `amqp_management_close` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1046 | LogError("messagereceiver_close failed"); |
AzureIoTClient | 19:000ab4e6a2c1 | 1047 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1048 | } |
AzureIoTClient | 6:641a9672db08 | 1049 | else |
AzureIoTClient | 6:641a9672db08 | 1050 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1051 | LIST_ITEM_HANDLE list_item_handle = singlylinkedlist_get_head_item(amqp_management->pending_operations); |
AzureIoTClient | 23:1111ee8bcba4 | 1052 | while (list_item_handle != NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1053 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1054 | OPERATION_MESSAGE_INSTANCE* operation_message = (OPERATION_MESSAGE_INSTANCE*)singlylinkedlist_item_get_value(list_item_handle); |
AzureIoTClient | 23:1111ee8bcba4 | 1055 | if (operation_message == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1056 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1057 | LogError("Cannot obtain pending operation"); |
AzureIoTClient | 23:1111ee8bcba4 | 1058 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1059 | else |
AzureIoTClient | 23:1111ee8bcba4 | 1060 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1061 | /* Codes_SRS_AMQP_MANAGEMENT_01_054: [ All pending operations shall be indicated complete with the code `AMQP_MANAGEMENT_EXECUTE_OPERATION_INSTANCE_CLOSED`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1062 | operation_message->on_execute_operation_complete(operation_message->callback_context, AMQP_MANAGEMENT_EXECUTE_OPERATION_INSTANCE_CLOSED, 0, NULL, NULL); |
AzureIoTClient | 23:1111ee8bcba4 | 1063 | free(operation_message); |
AzureIoTClient | 23:1111ee8bcba4 | 1064 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1065 | |
AzureIoTClient | 23:1111ee8bcba4 | 1066 | if (singlylinkedlist_remove(amqp_management->pending_operations, list_item_handle) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 1067 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1068 | LogError("Cannot remove item"); |
AzureIoTClient | 23:1111ee8bcba4 | 1069 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1070 | |
AzureIoTClient | 23:1111ee8bcba4 | 1071 | list_item_handle = singlylinkedlist_get_head_item(amqp_management->pending_operations); |
AzureIoTClient | 23:1111ee8bcba4 | 1072 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1073 | |
AzureIoTClient | 22:524bded3f7a8 | 1074 | amqp_management->amqp_management_state = AMQP_MANAGEMENT_STATE_IDLE; |
AzureIoTClient | 23:1111ee8bcba4 | 1075 | |
AzureIoTClient | 23:1111ee8bcba4 | 1076 | /* Codes_SRS_AMQP_MANAGEMENT_01_046: [ On success it shall return 0. ]*/ |
AzureIoTClient | 6:641a9672db08 | 1077 | result = 0; |
AzureIoTClient | 6:641a9672db08 | 1078 | } |
AzureIoTClient | 6:641a9672db08 | 1079 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1080 | |
AzureIoTClient | 6:641a9672db08 | 1081 | return result; |
Azure.IoT Build | 0:6ae2f7bca550 | 1082 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1083 | |
AzureIoTClient | 22:524bded3f7a8 | 1084 | int amqp_management_execute_operation_async(AMQP_MANAGEMENT_HANDLE amqp_management, const char* operation, const char* type, const char* locales, MESSAGE_HANDLE message, ON_AMQP_MANAGEMENT_EXECUTE_OPERATION_COMPLETE on_execute_operation_complete, void* on_execute_operation_complete_context) |
Azure.IoT Build | 0:6ae2f7bca550 | 1085 | { |
AzureIoTClient | 6:641a9672db08 | 1086 | int result; |
AzureIoTClient | 6:641a9672db08 | 1087 | |
AzureIoTClient | 6:641a9672db08 | 1088 | if ((amqp_management == NULL) || |
AzureIoTClient | 23:1111ee8bcba4 | 1089 | (operation == NULL) || |
AzureIoTClient | 23:1111ee8bcba4 | 1090 | (type == NULL) || |
AzureIoTClient | 23:1111ee8bcba4 | 1091 | (on_execute_operation_complete == NULL)) |
AzureIoTClient | 6:641a9672db08 | 1092 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1093 | /* Codes_SRS_AMQP_MANAGEMENT_01_057: [ If `amqp_management`, `operation`, `type` or `on_execute_operation_complete` is NULL, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1094 | LogError("Bad arguments: amqp_management = %p, operation = %p, type = %p", |
AzureIoTClient | 23:1111ee8bcba4 | 1095 | amqp_management, operation, type); |
AzureIoTClient | 23:1111ee8bcba4 | 1096 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 1097 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1098 | /* Codes_SRS_AMQP_MANAGEMENT_01_081: [ If `amqp_management_execute_operation_async` is called when not OPEN, it shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1099 | else if ((amqp_management->amqp_management_state == AMQP_MANAGEMENT_STATE_IDLE) || |
AzureIoTClient | 23:1111ee8bcba4 | 1100 | /* Codes_SRS_AMQP_MANAGEMENT_01_104: [ If `amqp_management_execute_operation_async` is called when the AMQP management is in error, it shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1101 | (amqp_management->amqp_management_state == AMQP_MANAGEMENT_STATE_ERROR)) |
AzureIoTClient | 23:1111ee8bcba4 | 1102 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1103 | LogError("amqp_management_execute_operation_async called while not open or in error"); |
AzureIoTClient | 19:000ab4e6a2c1 | 1104 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1105 | } |
AzureIoTClient | 6:641a9672db08 | 1106 | else |
AzureIoTClient | 6:641a9672db08 | 1107 | { |
AzureIoTClient | 6:641a9672db08 | 1108 | AMQP_VALUE application_properties; |
AzureIoTClient | 23:1111ee8bcba4 | 1109 | MESSAGE_HANDLE cloned_message; |
AzureIoTClient | 23:1111ee8bcba4 | 1110 | |
AzureIoTClient | 23:1111ee8bcba4 | 1111 | if (message == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1112 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1113 | /* Codes_SRS_AMQP_MANAGEMENT_01_102: [ If `message` is NULL, a new message shall be created by calling `message_create`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1114 | cloned_message = message_create(); |
AzureIoTClient | 23:1111ee8bcba4 | 1115 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1116 | else |
AzureIoTClient | 23:1111ee8bcba4 | 1117 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1118 | /* Codes_SRS_AMQP_MANAGEMENT_01_103: [ Otherwise the existing message shall be cloned by using `message_clone` before being modified accordingly and used for the pending operation. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1119 | cloned_message = message_clone(message); |
AzureIoTClient | 23:1111ee8bcba4 | 1120 | if (cloned_message == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1121 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1122 | LogError("Could not clone message"); |
AzureIoTClient | 23:1111ee8bcba4 | 1123 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1124 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1125 | |
AzureIoTClient | 23:1111ee8bcba4 | 1126 | if (cloned_message == NULL) |
AzureIoTClient | 6:641a9672db08 | 1127 | { |
AzureIoTClient | 19:000ab4e6a2c1 | 1128 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1129 | } |
AzureIoTClient | 6:641a9672db08 | 1130 | else |
AzureIoTClient | 6:641a9672db08 | 1131 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1132 | /* Codes_SRS_AMQP_MANAGEMENT_01_055: [ `amqp_management_execute_operation_async` shall start an AMQP management operation. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1133 | /* Codes_SRS_AMQP_MANAGEMENT_01_082: [ `amqp_management_execute_operation_async` shall obtain the application properties from the message by calling `message_get_application_properties`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1134 | if (message_get_application_properties(cloned_message, &application_properties) != 0) |
AzureIoTClient | 6:641a9672db08 | 1135 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1136 | LogError("Could not get application properties"); |
AzureIoTClient | 19:000ab4e6a2c1 | 1137 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1138 | } |
AzureIoTClient | 6:641a9672db08 | 1139 | else |
AzureIoTClient | 6:641a9672db08 | 1140 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1141 | if (application_properties == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1142 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1143 | /* Codes_SRS_AMQP_MANAGEMENT_01_083: [ If no application properties were set on the message, a new application properties instance shall be created by calling `amqpvalue_create_map`; ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1144 | application_properties = amqpvalue_create_map(); |
AzureIoTClient | 23:1111ee8bcba4 | 1145 | if (application_properties == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1146 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1147 | LogError("Could not create application properties"); |
AzureIoTClient | 23:1111ee8bcba4 | 1148 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1149 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1150 | |
AzureIoTClient | 23:1111ee8bcba4 | 1151 | if (application_properties == NULL) |
AzureIoTClient | 6:641a9672db08 | 1152 | { |
AzureIoTClient | 19:000ab4e6a2c1 | 1153 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1154 | } |
AzureIoTClient | 6:641a9672db08 | 1155 | else |
AzureIoTClient | 6:641a9672db08 | 1156 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1157 | /* Codes_SRS_AMQP_MANAGEMENT_01_084: [ For each of the arguments `operation`, `type` and `locales` an AMQP value of type string shall be created by calling `amqpvalue_create_string` in order to be used as key in the application properties map. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1158 | /* Codes_SRS_AMQP_MANAGEMENT_01_085: [ For each of the arguments `operation`, `type` and `locales` an AMQP value of type string containing the argument value shall be created by calling `amqpvalue_create_string` in order to be used as value in the application properties map. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1159 | /* Codes_SRS_AMQP_MANAGEMENT_01_058: [ Request messages have the following application-properties: ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1160 | /* Codes_SRS_AMQP_MANAGEMENT_01_059: [ operation string Yes The management operation to be performed. ] */ |
AzureIoTClient | 23:1111ee8bcba4 | 1161 | if ((add_string_key_value_pair_to_map(application_properties, "operation", operation) != 0) || |
AzureIoTClient | 23:1111ee8bcba4 | 1162 | /* Codes_SRS_AMQP_MANAGEMENT_01_061: [ type string Yes The Manageable Entity Type of the Manageable Entity to be managed. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1163 | (add_string_key_value_pair_to_map(application_properties, "type", type) != 0) || |
AzureIoTClient | 23:1111ee8bcba4 | 1164 | /* Codes_SRS_AMQP_MANAGEMENT_01_093: [ If `locales` is NULL, no key/value pair shall be added for it in the application properties map. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1165 | /* Codes_SRS_AMQP_MANAGEMENT_01_063: [ locales string No A list of locales that the sending peer permits for incoming informational text in response messages. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1166 | ((locales != NULL) && (add_string_key_value_pair_to_map(application_properties, "locales", locales) != 0))) |
AzureIoTClient | 6:641a9672db08 | 1167 | { |
AzureIoTClient | 19:000ab4e6a2c1 | 1168 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1169 | } |
AzureIoTClient | 6:641a9672db08 | 1170 | else |
AzureIoTClient | 6:641a9672db08 | 1171 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1172 | /* Codes_SRS_AMQP_MANAGEMENT_01_087: [ The application properties obtained after adding the key/value pairs shall be set on the message by calling `message_set_application_properties`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1173 | if (message_set_application_properties(cloned_message, application_properties) != 0) |
AzureIoTClient | 6:641a9672db08 | 1174 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1175 | /* Codes_SRS_AMQP_MANAGEMENT_01_090: [ If any APIs used to create and set the application properties on the message fails, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1176 | LogError("Could not set application properties"); |
AzureIoTClient | 23:1111ee8bcba4 | 1177 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 1178 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1179 | else if (set_message_id(cloned_message, amqp_management->next_message_id) != 0) |
AzureIoTClient | 23:1111ee8bcba4 | 1180 | { |
AzureIoTClient | 19:000ab4e6a2c1 | 1181 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1182 | } |
AzureIoTClient | 6:641a9672db08 | 1183 | else |
AzureIoTClient | 6:641a9672db08 | 1184 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1185 | OPERATION_MESSAGE_INSTANCE* pending_operation_message = (OPERATION_MESSAGE_INSTANCE*)malloc(sizeof(OPERATION_MESSAGE_INSTANCE)); |
AzureIoTClient | 23:1111ee8bcba4 | 1186 | if (pending_operation_message == NULL) |
AzureIoTClient | 6:641a9672db08 | 1187 | { |
AzureIoTClient | 19:000ab4e6a2c1 | 1188 | result = __FAILURE__; |
AzureIoTClient | 6:641a9672db08 | 1189 | } |
AzureIoTClient | 6:641a9672db08 | 1190 | else |
AzureIoTClient | 6:641a9672db08 | 1191 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1192 | LIST_ITEM_HANDLE added_item; |
AzureIoTClient | 23:1111ee8bcba4 | 1193 | pending_operation_message->callback_context = on_execute_operation_complete_context; |
AzureIoTClient | 23:1111ee8bcba4 | 1194 | pending_operation_message->on_execute_operation_complete = on_execute_operation_complete; |
AzureIoTClient | 23:1111ee8bcba4 | 1195 | pending_operation_message->message_id = amqp_management->next_message_id; |
AzureIoTClient | 41:0e723f9cbd89 | 1196 | pending_operation_message->amqp_management = amqp_management; |
AzureIoTClient | 23:1111ee8bcba4 | 1197 | |
AzureIoTClient | 23:1111ee8bcba4 | 1198 | /* Codes_SRS_AMQP_MANAGEMENT_01_091: [ Once the request message has been sent, an entry shall be stored in the pending operations list by calling `singlylinkedlist_add`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1199 | added_item = singlylinkedlist_add(amqp_management->pending_operations, pending_operation_message); |
AzureIoTClient | 23:1111ee8bcba4 | 1200 | if (added_item == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1201 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1202 | /* Codes_SRS_AMQP_MANAGEMENT_01_092: [ If `singlylinkedlist_add` fails then `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1203 | LogError("Could not add the operation to the pending operations list."); |
AzureIoTClient | 23:1111ee8bcba4 | 1204 | free(pending_operation_message); |
AzureIoTClient | 23:1111ee8bcba4 | 1205 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 1206 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1207 | else |
AzureIoTClient | 23:1111ee8bcba4 | 1208 | { |
AzureIoTClient | 41:0e723f9cbd89 | 1209 | /* Codes_SRS_AMQP_MANAGEMENT_01_088: [ `amqp_management_execute_operation_async` shall send the message by calling `messagesender_send_async`. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 1210 | /* Codes_SRS_AMQP_MANAGEMENT_01_166: [ The `on_message_send_complete` callback shall be passed to the `messagesender_send_async` call. ]*/ |
AzureIoTClient | 41:0e723f9cbd89 | 1211 | if (messagesender_send_async(amqp_management->message_sender, cloned_message, on_message_send_complete, added_item, 0) == NULL) |
AzureIoTClient | 23:1111ee8bcba4 | 1212 | { |
AzureIoTClient | 34:6be9c2058664 | 1213 | /* Codes_SRS_AMQP_MANAGEMENT_01_089: [ If `messagesender_send_async` fails, `amqp_management_execute_operation_async` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1214 | LogError("Could not send request message"); |
AzureIoTClient | 23:1111ee8bcba4 | 1215 | (void)singlylinkedlist_remove(amqp_management->pending_operations, added_item); |
AzureIoTClient | 23:1111ee8bcba4 | 1216 | free(pending_operation_message); |
AzureIoTClient | 23:1111ee8bcba4 | 1217 | result = __FAILURE__; |
AzureIoTClient | 23:1111ee8bcba4 | 1218 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1219 | else |
AzureIoTClient | 23:1111ee8bcba4 | 1220 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1221 | /* Codes_SRS_AMQP_MANAGEMENT_01_107: [ The message Id set on the message properties shall be incremented with each operation. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1222 | amqp_management->next_message_id++; |
AzureIoTClient | 23:1111ee8bcba4 | 1223 | |
AzureIoTClient | 23:1111ee8bcba4 | 1224 | /* Codes_SRS_AMQP_MANAGEMENT_01_056: [ On success it shall return 0. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1225 | result = 0; |
AzureIoTClient | 23:1111ee8bcba4 | 1226 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1227 | } |
AzureIoTClient | 6:641a9672db08 | 1228 | } |
AzureIoTClient | 6:641a9672db08 | 1229 | } |
AzureIoTClient | 6:641a9672db08 | 1230 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1231 | |
AzureIoTClient | 23:1111ee8bcba4 | 1232 | /* Codes_SRS_AMQP_MANAGEMENT_01_101: [ After setting the application properties, the application properties instance shall be freed by `amqpvalue_destroy`. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1233 | amqpvalue_destroy(application_properties); |
AzureIoTClient | 6:641a9672db08 | 1234 | } |
AzureIoTClient | 6:641a9672db08 | 1235 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1236 | |
AzureIoTClient | 23:1111ee8bcba4 | 1237 | message_destroy(cloned_message); |
AzureIoTClient | 6:641a9672db08 | 1238 | } |
AzureIoTClient | 6:641a9672db08 | 1239 | } |
AzureIoTClient | 6:641a9672db08 | 1240 | return result; |
AzureIoTClient | 6:641a9672db08 | 1241 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1242 | |
AzureIoTClient | 23:1111ee8bcba4 | 1243 | void amqp_management_set_trace(AMQP_MANAGEMENT_HANDLE amqp_management, bool trace_on) |
AzureIoTClient | 6:641a9672db08 | 1244 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1245 | if (amqp_management == NULL) |
AzureIoTClient | 6:641a9672db08 | 1246 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1247 | /* Codes_SRS_AMQP_MANAGEMENT_01_163: [ If `amqp_management` is NULL, `amqp_management_set_trace` shal do nothing. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1248 | LogError("NULL amqp_management"); |
AzureIoTClient | 23:1111ee8bcba4 | 1249 | } |
AzureIoTClient | 23:1111ee8bcba4 | 1250 | else |
AzureIoTClient | 23:1111ee8bcba4 | 1251 | { |
AzureIoTClient | 23:1111ee8bcba4 | 1252 | /* Codes_SRS_AMQP_MANAGEMENT_01_161: [ `amqp_management_set_trace` shall call `messagesender_set_trace` to enable/disable tracing on the message sender. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1253 | messagesender_set_trace(amqp_management->message_sender, trace_on); |
AzureIoTClient | 23:1111ee8bcba4 | 1254 | /* Codes_SRS_AMQP_MANAGEMENT_01_162: [ `amqp_management_set_trace` shall call `messagereceiver_set_trace` to enable/disable tracing on the message receiver. ]*/ |
AzureIoTClient | 23:1111ee8bcba4 | 1255 | messagereceiver_set_trace(amqp_management->message_receiver, trace_on); |
AzureIoTClient | 6:641a9672db08 | 1256 | } |
Azure.IoT Build | 0:6ae2f7bca550 | 1257 | } |
AzureIoTClient | 39:e7c983378f41 | 1258 | |
AzureIoTClient | 39:e7c983378f41 | 1259 | int amqp_management_set_override_status_code_key_name(AMQP_MANAGEMENT_HANDLE amqp_management, const char* override_status_code_key_name) |
AzureIoTClient | 39:e7c983378f41 | 1260 | { |
AzureIoTClient | 39:e7c983378f41 | 1261 | int result; |
AzureIoTClient | 39:e7c983378f41 | 1262 | |
AzureIoTClient | 39:e7c983378f41 | 1263 | /* Codes_SRS_AMQP_MANAGEMENT_01_171: [ If `amqp_management` is NULL, `amqp_management_set_override_status_code_key_name` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1264 | if ((amqp_management == NULL) || |
AzureIoTClient | 39:e7c983378f41 | 1265 | /* Codes_SRS_AMQP_MANAGEMENT_01_172: [ If `override_status_code_key_name` is NULL, `amqp_management_set_override_status_code_key_name` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1266 | (override_status_code_key_name == NULL)) |
AzureIoTClient | 39:e7c983378f41 | 1267 | { |
AzureIoTClient | 39:e7c983378f41 | 1268 | LogError("Bad arguments: amqp_management = %p, override_status_code_key_name = %s", |
AzureIoTClient | 39:e7c983378f41 | 1269 | amqp_management, P_OR_NULL(override_status_code_key_name)); |
AzureIoTClient | 39:e7c983378f41 | 1270 | result = __FAILURE__; |
AzureIoTClient | 39:e7c983378f41 | 1271 | } |
AzureIoTClient | 39:e7c983378f41 | 1272 | else |
AzureIoTClient | 39:e7c983378f41 | 1273 | { |
AzureIoTClient | 39:e7c983378f41 | 1274 | /* Codes_SRS_AMQP_MANAGEMENT_01_167: [ `amqp_management_set_override_status_code_key_name` shall set the status code key name used to parse the status code from the reply messages to `override_status_code_key_name`. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1275 | /* Codes_SRS_AMQP_MANAGEMENT_01_168: [ `amqp_management_set_override_status_code_key_name` shall copy the `override_status_code_key_name` string. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1276 | /* Codes_SRS_AMQP_MANAGEMENT_01_169: [ `amqp_management_set_override_status_code_key_name` shall free any string previously used for the status code key name. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1277 | if (internal_set_status_code_key_name(amqp_management, override_status_code_key_name) != 0) |
AzureIoTClient | 39:e7c983378f41 | 1278 | { |
AzureIoTClient | 39:e7c983378f41 | 1279 | /* Codes_SRS_AMQP_MANAGEMENT_01_173: [ If any error occurs in copying the `override_status_code_key_name` string, `amqp_management_set_override_status_code_key_name` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1280 | LogError("Cannot set status code key name"); |
AzureIoTClient | 39:e7c983378f41 | 1281 | result = __FAILURE__; |
AzureIoTClient | 39:e7c983378f41 | 1282 | } |
AzureIoTClient | 39:e7c983378f41 | 1283 | else |
AzureIoTClient | 39:e7c983378f41 | 1284 | { |
AzureIoTClient | 39:e7c983378f41 | 1285 | /* Codes_SRS_AMQP_MANAGEMENT_01_170: [ On success, `amqp_management_set_override_status_code_key_name` shall return 0. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1286 | result = 0; |
AzureIoTClient | 39:e7c983378f41 | 1287 | } |
AzureIoTClient | 39:e7c983378f41 | 1288 | } |
AzureIoTClient | 39:e7c983378f41 | 1289 | |
AzureIoTClient | 39:e7c983378f41 | 1290 | return result; |
AzureIoTClient | 39:e7c983378f41 | 1291 | } |
AzureIoTClient | 39:e7c983378f41 | 1292 | |
AzureIoTClient | 39:e7c983378f41 | 1293 | int amqp_management_set_override_status_description_key_name(AMQP_MANAGEMENT_HANDLE amqp_management, const char* override_status_description_key_name) |
AzureIoTClient | 39:e7c983378f41 | 1294 | { |
AzureIoTClient | 39:e7c983378f41 | 1295 | int result; |
AzureIoTClient | 39:e7c983378f41 | 1296 | |
AzureIoTClient | 39:e7c983378f41 | 1297 | /* Codes_SRS_AMQP_MANAGEMENT_01_178: [ If `amqp_management` is NULL, `amqp_management_set_override_status_description_key_name` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1298 | if ((amqp_management == NULL) || |
AzureIoTClient | 39:e7c983378f41 | 1299 | /* Tests_SRS_AMQP_MANAGEMENT_01_179: [ If `override_status_description_key_name` is NULL, `amqp_management_set_override_status_description_key_name` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1300 | (override_status_description_key_name == NULL)) |
AzureIoTClient | 39:e7c983378f41 | 1301 | { |
AzureIoTClient | 39:e7c983378f41 | 1302 | LogError("Bad arguments: amqp_management = %p, override_status_description_key_name = %s", |
AzureIoTClient | 39:e7c983378f41 | 1303 | amqp_management, P_OR_NULL(override_status_description_key_name)); |
AzureIoTClient | 39:e7c983378f41 | 1304 | result = __FAILURE__; |
AzureIoTClient | 39:e7c983378f41 | 1305 | } |
AzureIoTClient | 39:e7c983378f41 | 1306 | else |
AzureIoTClient | 39:e7c983378f41 | 1307 | { |
AzureIoTClient | 39:e7c983378f41 | 1308 | /* Codes_SRS_AMQP_MANAGEMENT_01_174: [ `amqp_management_set_override_status_description_key_name` shall set the status description key name used to parse the status description from the reply messages to `over ride_status_description_key_name`.]*/ |
AzureIoTClient | 39:e7c983378f41 | 1309 | /* Codes_SRS_AMQP_MANAGEMENT_01_175: [ `amqp_management_set_override_status_description_key_name` shall copy the `override_status_description_key_name` string. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1310 | /* Codes_SRS_AMQP_MANAGEMENT_01_176: [ `amqp_management_set_override_status_description_key_name` shall free any string previously used for the status description key name. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1311 | /* Codes_SRS_AMQP_MANAGEMENT_01_177: [ On success, `amqp_management_set_override_status_description_key_name` shall return 0. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1312 | if (internal_set_status_description_key_name(amqp_management, override_status_description_key_name) != 0) |
AzureIoTClient | 39:e7c983378f41 | 1313 | { |
AzureIoTClient | 39:e7c983378f41 | 1314 | /* Codes_SRS_AMQP_MANAGEMENT_01_180: [ If any error occurs in copying the `override_status_description_key_name` string, `amqp_management_set_override_status_description_key_name` shall fail and return a non-zero value. ]*/ |
AzureIoTClient | 39:e7c983378f41 | 1315 | LogError("Cannot set status description key name"); |
AzureIoTClient | 39:e7c983378f41 | 1316 | result = __FAILURE__; |
AzureIoTClient | 39:e7c983378f41 | 1317 | } |
AzureIoTClient | 39:e7c983378f41 | 1318 | else |
AzureIoTClient | 39:e7c983378f41 | 1319 | { |
AzureIoTClient | 39:e7c983378f41 | 1320 | result = 0; |
AzureIoTClient | 39:e7c983378f41 | 1321 | } |
AzureIoTClient | 39:e7c983378f41 | 1322 | } |
AzureIoTClient | 39:e7c983378f41 | 1323 | |
AzureIoTClient | 39:e7c983378f41 | 1324 | return result; |
AzureIoTClient | 39:e7c983378f41 | 1325 | } |