Azure.IoT Build 0:6ae2f7bca550 1 // Copyright (c) Microsoft. All rights reserved.
Azure.IoT Build 0:6ae2f7bca550 2 // Licensed under the MIT license. See LICENSE file in the project root for full license information.
Azure.IoT Build 0:6ae2f7bca550 3
Azure.IoT Build 0:6ae2f7bca550 4 #include <stdlib.h>
Azure.IoT Build 0:6ae2f7bca550 5 #include <string.h>
AzureIoTClient 24:2c59c2d43ebf 6 #include <stdint.h>
AzureIoTClient 19:000ab4e6a2c1 7 #include "azure_c_shared_utility/optimize_size.h"
AzureIoTClient 20:206846c14c80 8 #include "azure_c_shared_utility/gballoc.h"
AzureIoTClient 24:2c59c2d43ebf 9 #include "azure_c_shared_utility/xlogging.h"
AzureIoTClient 40:f0ceafa8d570 10 #include "azure_uamqp_c/amqp_definitions.h"
Azure.IoT Build 0:6ae2f7bca550 11 #include "azure_uamqp_c/message.h"
Azure.IoT Build 0:6ae2f7bca550 12 #include "azure_uamqp_c/amqpvalue.h"
Azure.IoT Build 0:6ae2f7bca550 13
Azure.IoT Build 0:6ae2f7bca550 14 typedef struct BODY_AMQP_DATA_TAG
Azure.IoT Build 0:6ae2f7bca550 15 {
AzureIoTClient 28:add19eb7defa 16 unsigned char* body_data_section_bytes;
AzureIoTClient 28:add19eb7defa 17 size_t body_data_section_length;
Azure.IoT Build 0:6ae2f7bca550 18 } BODY_AMQP_DATA;
Azure.IoT Build 0:6ae2f7bca550 19
Azure.IoT Build 0:6ae2f7bca550 20 typedef struct MESSAGE_INSTANCE_TAG
Azure.IoT Build 0:6ae2f7bca550 21 {
AzureIoTClient 28:add19eb7defa 22 BODY_AMQP_DATA* body_amqp_data_items;
AzureIoTClient 28:add19eb7defa 23 size_t body_amqp_data_count;
AzureIoTClient 28:add19eb7defa 24 AMQP_VALUE* body_amqp_sequence_items;
AzureIoTClient 28:add19eb7defa 25 size_t body_amqp_sequence_count;
AzureIoTClient 28:add19eb7defa 26 AMQP_VALUE body_amqp_value;
AzureIoTClient 28:add19eb7defa 27 HEADER_HANDLE header;
AzureIoTClient 28:add19eb7defa 28 delivery_annotations delivery_annotations;
AzureIoTClient 28:add19eb7defa 29 message_annotations message_annotations;
AzureIoTClient 28:add19eb7defa 30 PROPERTIES_HANDLE properties;
AzureIoTClient 28:add19eb7defa 31 application_properties application_properties;
AzureIoTClient 28:add19eb7defa 32 annotations footer;
Azure.IoT Build 0:6ae2f7bca550 33 uint32_t message_format;
Azure.IoT Build 0:6ae2f7bca550 34 } MESSAGE_INSTANCE;
Azure.IoT Build 0:6ae2f7bca550 35
AzureIoTClient 28:add19eb7defa 36 MESSAGE_BODY_TYPE internal_get_body_type(MESSAGE_HANDLE message)
AzureIoTClient 28:add19eb7defa 37 {
AzureIoTClient 28:add19eb7defa 38 MESSAGE_BODY_TYPE result;
AzureIoTClient 28:add19eb7defa 39
AzureIoTClient 28:add19eb7defa 40 if (message->body_amqp_value != NULL)
AzureIoTClient 28:add19eb7defa 41 {
AzureIoTClient 28:add19eb7defa 42 result = MESSAGE_BODY_TYPE_VALUE;
AzureIoTClient 28:add19eb7defa 43 }
AzureIoTClient 28:add19eb7defa 44 else if (message->body_amqp_data_count > 0)
AzureIoTClient 28:add19eb7defa 45 {
AzureIoTClient 28:add19eb7defa 46 result = MESSAGE_BODY_TYPE_DATA;
AzureIoTClient 28:add19eb7defa 47 }
AzureIoTClient 28:add19eb7defa 48 else if (message->body_amqp_sequence_count > 0)
AzureIoTClient 28:add19eb7defa 49 {
AzureIoTClient 28:add19eb7defa 50 result = MESSAGE_BODY_TYPE_SEQUENCE;
AzureIoTClient 28:add19eb7defa 51 }
AzureIoTClient 28:add19eb7defa 52 else
AzureIoTClient 28:add19eb7defa 53 {
AzureIoTClient 28:add19eb7defa 54 result = MESSAGE_BODY_TYPE_NONE;
AzureIoTClient 28:add19eb7defa 55 }
AzureIoTClient 28:add19eb7defa 56
AzureIoTClient 28:add19eb7defa 57 return result;
AzureIoTClient 28:add19eb7defa 58 }
AzureIoTClient 28:add19eb7defa 59
AzureIoTClient 24:2c59c2d43ebf 60 static void free_all_body_data_items(MESSAGE_HANDLE message)
Azure.IoT Build 0:6ae2f7bca550 61 {
AzureIoTClient 28:add19eb7defa 62 size_t i;
Azure.IoT Build 0:6ae2f7bca550 63
AzureIoTClient 28:add19eb7defa 64 for (i = 0; i < message->body_amqp_data_count; i++)
AzureIoTClient 28:add19eb7defa 65 {
AzureIoTClient 28:add19eb7defa 66 if (message->body_amqp_data_items[i].body_data_section_bytes != NULL)
AzureIoTClient 28:add19eb7defa 67 {
AzureIoTClient 28:add19eb7defa 68 free(message->body_amqp_data_items[i].body_data_section_bytes);
AzureIoTClient 28:add19eb7defa 69 }
AzureIoTClient 28:add19eb7defa 70 }
Azure.IoT Build 0:6ae2f7bca550 71
AzureIoTClient 28:add19eb7defa 72 if (message->body_amqp_data_items != NULL)
AzureIoTClient 28:add19eb7defa 73 {
AzureIoTClient 28:add19eb7defa 74 free(message->body_amqp_data_items);
AzureIoTClient 28:add19eb7defa 75 }
AzureIoTClient 28:add19eb7defa 76 message->body_amqp_data_count = 0;
AzureIoTClient 28:add19eb7defa 77 message->body_amqp_data_items = NULL;
Azure.IoT Build 0:6ae2f7bca550 78 }
Azure.IoT Build 0:6ae2f7bca550 79
AzureIoTClient 24:2c59c2d43ebf 80 static void free_all_body_sequence_items(MESSAGE_HANDLE message)
Azure.IoT Build 0:6ae2f7bca550 81 {
AzureIoTClient 28:add19eb7defa 82 size_t i;
Azure.IoT Build 0:6ae2f7bca550 83
AzureIoTClient 28:add19eb7defa 84 for (i = 0; i < message->body_amqp_sequence_count; i++)
AzureIoTClient 28:add19eb7defa 85 {
AzureIoTClient 28:add19eb7defa 86 if (message->body_amqp_sequence_items[i] != NULL)
AzureIoTClient 28:add19eb7defa 87 {
AzureIoTClient 28:add19eb7defa 88 /* Codes_SRS_MESSAGE_01_137: [ Each sequence shall be freed by calling `amqpvalue_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 89 amqpvalue_destroy(message->body_amqp_sequence_items[i]);
AzureIoTClient 28:add19eb7defa 90 }
AzureIoTClient 28:add19eb7defa 91 }
Azure.IoT Build 0:6ae2f7bca550 92
AzureIoTClient 28:add19eb7defa 93 if (message->body_amqp_sequence_items != NULL)
AzureIoTClient 28:add19eb7defa 94 {
AzureIoTClient 28:add19eb7defa 95 free(message->body_amqp_sequence_items);
AzureIoTClient 28:add19eb7defa 96 }
AzureIoTClient 28:add19eb7defa 97 message->body_amqp_sequence_count = 0;
AzureIoTClient 28:add19eb7defa 98 message->body_amqp_sequence_items = NULL;
Azure.IoT Build 0:6ae2f7bca550 99 }
Azure.IoT Build 0:6ae2f7bca550 100
Azure.IoT Build 0:6ae2f7bca550 101 MESSAGE_HANDLE message_create(void)
Azure.IoT Build 0:6ae2f7bca550 102 {
AzureIoTClient 28:add19eb7defa 103 MESSAGE_HANDLE result = (MESSAGE_HANDLE)malloc(sizeof(MESSAGE_INSTANCE));
AzureIoTClient 28:add19eb7defa 104 if (result == NULL)
AzureIoTClient 28:add19eb7defa 105 {
AzureIoTClient 28:add19eb7defa 106 /* Codes_SRS_MESSAGE_01_002: [If allocating memory for the message fails, `message_create` shall fail and return NULL.] */
AzureIoTClient 28:add19eb7defa 107 LogError("Cannot allocate memory for message");
AzureIoTClient 28:add19eb7defa 108 }
AzureIoTClient 28:add19eb7defa 109 else
AzureIoTClient 28:add19eb7defa 110 {
AzureIoTClient 28:add19eb7defa 111 result->header = NULL;
AzureIoTClient 28:add19eb7defa 112 result->delivery_annotations = NULL;
AzureIoTClient 28:add19eb7defa 113 result->message_annotations = NULL;
AzureIoTClient 28:add19eb7defa 114 result->properties = NULL;
AzureIoTClient 28:add19eb7defa 115 result->application_properties = NULL;
AzureIoTClient 28:add19eb7defa 116 result->footer = NULL;
AzureIoTClient 28:add19eb7defa 117 result->body_amqp_data_items = NULL;
AzureIoTClient 28:add19eb7defa 118 result->body_amqp_data_count = 0;
AzureIoTClient 28:add19eb7defa 119 result->body_amqp_value = NULL;
AzureIoTClient 28:add19eb7defa 120 result->body_amqp_sequence_items = NULL;
AzureIoTClient 28:add19eb7defa 121 result->body_amqp_sequence_count = 0;
AzureIoTClient 28:add19eb7defa 122
AzureIoTClient 28:add19eb7defa 123 /* Codes_SRS_MESSAGE_01_135: [ By default a message on which `message_set_message_format` was not called shall have message format set to 0. ]*/
Azure.IoT Build 0:6ae2f7bca550 124 result->message_format = 0;
AzureIoTClient 28:add19eb7defa 125 }
Azure.IoT Build 0:6ae2f7bca550 126
AzureIoTClient 28:add19eb7defa 127 /* Codes_SRS_MESSAGE_01_001: [`message_create` shall create a new AMQP message instance and on success it shall return a non-NULL handle for the newly created message instance.] */
AzureIoTClient 28:add19eb7defa 128 return result;
Azure.IoT Build 0:6ae2f7bca550 129 }
Azure.IoT Build 0:6ae2f7bca550 130
Azure.IoT Build 0:6ae2f7bca550 131 MESSAGE_HANDLE message_clone(MESSAGE_HANDLE source_message)
Azure.IoT Build 0:6ae2f7bca550 132 {
AzureIoTClient 28:add19eb7defa 133 MESSAGE_HANDLE result;
Azure.IoT Build 0:6ae2f7bca550 134
AzureIoTClient 28:add19eb7defa 135 if (source_message == NULL)
AzureIoTClient 28:add19eb7defa 136 {
AzureIoTClient 28:add19eb7defa 137 /* Codes_SRS_MESSAGE_01_062: [If `source_message` is NULL, `message_clone` shall fail and return NULL.] */
AzureIoTClient 28:add19eb7defa 138 LogError("NULL source_message");
AzureIoTClient 28:add19eb7defa 139 result = NULL;
AzureIoTClient 28:add19eb7defa 140 }
AzureIoTClient 28:add19eb7defa 141 else
AzureIoTClient 28:add19eb7defa 142 {
AzureIoTClient 28:add19eb7defa 143 /* Codes_SRS_MESSAGE_01_003: [`message_clone` shall clone a message entirely and on success return a non-NULL handle to the cloned message.] */
AzureIoTClient 28:add19eb7defa 144 result = (MESSAGE_HANDLE)message_create();
AzureIoTClient 28:add19eb7defa 145 if (result == NULL)
AzureIoTClient 28:add19eb7defa 146 {
AzureIoTClient 28:add19eb7defa 147 /* Codes_SRS_MESSAGE_01_004: [If allocating memory for the new cloned message fails, `message_clone` shall fail and return NULL.] */
AzureIoTClient 28:add19eb7defa 148 LogError("Cannot clone message");
AzureIoTClient 28:add19eb7defa 149 }
AzureIoTClient 28:add19eb7defa 150 else
AzureIoTClient 28:add19eb7defa 151 {
AzureIoTClient 24:2c59c2d43ebf 152 result->message_format = source_message->message_format;
Azure.IoT Build 0:6ae2f7bca550 153
AzureIoTClient 28:add19eb7defa 154 if (source_message->header != NULL)
AzureIoTClient 28:add19eb7defa 155 {
AzureIoTClient 28:add19eb7defa 156 /* Codes_SRS_MESSAGE_01_005: [If a header exists on the source message it shall be cloned by using `header_clone`.] */
AzureIoTClient 28:add19eb7defa 157 result->header = header_clone(source_message->header);
AzureIoTClient 28:add19eb7defa 158 if (result->header == NULL)
AzureIoTClient 28:add19eb7defa 159 {
AzureIoTClient 28:add19eb7defa 160 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 161 LogError("Cannot clone message header");
AzureIoTClient 28:add19eb7defa 162 message_destroy(result);
AzureIoTClient 28:add19eb7defa 163 result = NULL;
AzureIoTClient 28:add19eb7defa 164 }
AzureIoTClient 28:add19eb7defa 165 }
Azure.IoT Build 0:6ae2f7bca550 166
AzureIoTClient 28:add19eb7defa 167 if ((result != NULL) && (source_message->delivery_annotations != NULL))
AzureIoTClient 28:add19eb7defa 168 {
AzureIoTClient 28:add19eb7defa 169 /* Codes_SRS_MESSAGE_01_006: [If delivery annotations exist on the source message they shall be cloned by using `annotations_clone`.] */
AzureIoTClient 28:add19eb7defa 170 result->delivery_annotations = annotations_clone(source_message->delivery_annotations);
AzureIoTClient 28:add19eb7defa 171 if (result->delivery_annotations == NULL)
AzureIoTClient 28:add19eb7defa 172 {
AzureIoTClient 28:add19eb7defa 173 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 174 LogError("Cannot clone delivery annotations");
AzureIoTClient 28:add19eb7defa 175 message_destroy(result);
AzureIoTClient 28:add19eb7defa 176 result = NULL;
AzureIoTClient 28:add19eb7defa 177 }
AzureIoTClient 28:add19eb7defa 178 }
Azure.IoT Build 0:6ae2f7bca550 179
AzureIoTClient 28:add19eb7defa 180 if ((result != NULL) && (source_message->message_annotations != NULL))
AzureIoTClient 28:add19eb7defa 181 {
AzureIoTClient 28:add19eb7defa 182 /* Codes_SRS_MESSAGE_01_007: [If message annotations exist on the source message they shall be cloned by using `annotations_clone`.] */
AzureIoTClient 28:add19eb7defa 183 result->message_annotations = annotations_clone(source_message->message_annotations);
AzureIoTClient 28:add19eb7defa 184 if (result->message_annotations == NULL)
AzureIoTClient 28:add19eb7defa 185 {
AzureIoTClient 28:add19eb7defa 186 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 187 LogError("Cannot clone message annotations");
AzureIoTClient 28:add19eb7defa 188 message_destroy(result);
AzureIoTClient 28:add19eb7defa 189 result = NULL;
AzureIoTClient 28:add19eb7defa 190 }
AzureIoTClient 28:add19eb7defa 191 }
Azure.IoT Build 0:6ae2f7bca550 192
AzureIoTClient 28:add19eb7defa 193 if ((result != NULL) && (source_message->properties != NULL))
AzureIoTClient 28:add19eb7defa 194 {
AzureIoTClient 28:add19eb7defa 195 /* Codes_SRS_MESSAGE_01_008: [If message properties exist on the source message they shall be cloned by using `properties_clone`.] */
AzureIoTClient 28:add19eb7defa 196 result->properties = properties_clone(source_message->properties);
AzureIoTClient 28:add19eb7defa 197 if (result->properties == NULL)
AzureIoTClient 28:add19eb7defa 198 {
AzureIoTClient 28:add19eb7defa 199 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 200 LogError("Cannot clone message properties");
AzureIoTClient 28:add19eb7defa 201 message_destroy(result);
AzureIoTClient 28:add19eb7defa 202 result = NULL;
AzureIoTClient 28:add19eb7defa 203 }
AzureIoTClient 28:add19eb7defa 204 }
Azure.IoT Build 0:6ae2f7bca550 205
AzureIoTClient 28:add19eb7defa 206 if ((result != NULL) && (source_message->application_properties != NULL))
AzureIoTClient 28:add19eb7defa 207 {
AzureIoTClient 28:add19eb7defa 208 /* Codes_SRS_MESSAGE_01_009: [If application properties exist on the source message they shall be cloned by using `amqpvalue_clone`.] */
AzureIoTClient 28:add19eb7defa 209 result->application_properties = amqpvalue_clone(source_message->application_properties);
AzureIoTClient 28:add19eb7defa 210 if (result->application_properties == NULL)
AzureIoTClient 28:add19eb7defa 211 {
AzureIoTClient 28:add19eb7defa 212 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 213 LogError("Cannot clone application annotations");
AzureIoTClient 28:add19eb7defa 214 message_destroy(result);
AzureIoTClient 28:add19eb7defa 215 result = NULL;
AzureIoTClient 28:add19eb7defa 216 }
AzureIoTClient 28:add19eb7defa 217 }
Azure.IoT Build 0:6ae2f7bca550 218
AzureIoTClient 28:add19eb7defa 219 if ((result != NULL) && (source_message->footer != NULL))
AzureIoTClient 28:add19eb7defa 220 {
AzureIoTClient 28:add19eb7defa 221 /* Codes_SRS_MESSAGE_01_010: [If a footer exists on the source message it shall be cloned by using `annotations_clone`.] */
AzureIoTClient 28:add19eb7defa 222 result->footer = amqpvalue_clone(source_message->footer);
AzureIoTClient 28:add19eb7defa 223 if (result->footer == NULL)
AzureIoTClient 28:add19eb7defa 224 {
AzureIoTClient 28:add19eb7defa 225 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 226 LogError("Cannot clone message footer");
AzureIoTClient 28:add19eb7defa 227 message_destroy(result);
AzureIoTClient 28:add19eb7defa 228 result = NULL;
AzureIoTClient 28:add19eb7defa 229 }
AzureIoTClient 28:add19eb7defa 230 }
Azure.IoT Build 0:6ae2f7bca550 231
AzureIoTClient 28:add19eb7defa 232 if ((result != NULL) && (source_message->body_amqp_data_count > 0))
AzureIoTClient 28:add19eb7defa 233 {
AzureIoTClient 28:add19eb7defa 234 size_t i;
Azure.IoT Build 0:6ae2f7bca550 235
AzureIoTClient 28:add19eb7defa 236 result->body_amqp_data_items = (BODY_AMQP_DATA*)malloc(source_message->body_amqp_data_count * sizeof(BODY_AMQP_DATA));
AzureIoTClient 28:add19eb7defa 237 if (result->body_amqp_data_items == NULL)
AzureIoTClient 28:add19eb7defa 238 {
AzureIoTClient 28:add19eb7defa 239 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 240 LogError("Cannot allocate memory for body data sections");
AzureIoTClient 28:add19eb7defa 241 message_destroy(result);
AzureIoTClient 28:add19eb7defa 242 result = NULL;
AzureIoTClient 28:add19eb7defa 243 }
AzureIoTClient 28:add19eb7defa 244 else
AzureIoTClient 28:add19eb7defa 245 {
AzureIoTClient 28:add19eb7defa 246 for (i = 0; i < source_message->body_amqp_data_count; i++)
AzureIoTClient 28:add19eb7defa 247 {
AzureIoTClient 28:add19eb7defa 248 result->body_amqp_data_items[i].body_data_section_length = source_message->body_amqp_data_items[i].body_data_section_length;
Azure.IoT Build 0:6ae2f7bca550 249
AzureIoTClient 28:add19eb7defa 250 /* Codes_SRS_MESSAGE_01_011: [If an AMQP data has been set as message body on the source message it shall be cloned by allocating memory for the binary payload.] */
AzureIoTClient 28:add19eb7defa 251 result->body_amqp_data_items[i].body_data_section_bytes = (unsigned char*)malloc(source_message->body_amqp_data_items[i].body_data_section_length);
AzureIoTClient 28:add19eb7defa 252 if (result->body_amqp_data_items[i].body_data_section_bytes == NULL)
AzureIoTClient 28:add19eb7defa 253 {
AzureIoTClient 28:add19eb7defa 254 LogError("Cannot allocate memory for body data section %u", (unsigned int)i);
AzureIoTClient 28:add19eb7defa 255 break;
AzureIoTClient 28:add19eb7defa 256 }
AzureIoTClient 28:add19eb7defa 257 else
AzureIoTClient 28:add19eb7defa 258 {
AzureIoTClient 28:add19eb7defa 259 (void)memcpy(result->body_amqp_data_items[i].body_data_section_bytes, source_message->body_amqp_data_items[i].body_data_section_bytes, result->body_amqp_data_items[i].body_data_section_length);
AzureIoTClient 28:add19eb7defa 260 }
AzureIoTClient 28:add19eb7defa 261 }
Azure.IoT Build 0:6ae2f7bca550 262
AzureIoTClient 28:add19eb7defa 263 result->body_amqp_data_count = i;
AzureIoTClient 28:add19eb7defa 264 if (i < source_message->body_amqp_data_count)
AzureIoTClient 28:add19eb7defa 265 {
AzureIoTClient 28:add19eb7defa 266 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 267 message_destroy(result);
AzureIoTClient 28:add19eb7defa 268 result = NULL;
AzureIoTClient 28:add19eb7defa 269 }
AzureIoTClient 28:add19eb7defa 270 }
AzureIoTClient 28:add19eb7defa 271 }
Azure.IoT Build 0:6ae2f7bca550 272
AzureIoTClient 28:add19eb7defa 273 if ((result != NULL) && (source_message->body_amqp_sequence_count > 0))
AzureIoTClient 28:add19eb7defa 274 {
AzureIoTClient 28:add19eb7defa 275 size_t i;
Azure.IoT Build 0:6ae2f7bca550 276
AzureIoTClient 28:add19eb7defa 277 result->body_amqp_sequence_items = (AMQP_VALUE*)malloc(source_message->body_amqp_sequence_count * sizeof(AMQP_VALUE));
AzureIoTClient 28:add19eb7defa 278 if (result->body_amqp_sequence_items == NULL)
AzureIoTClient 28:add19eb7defa 279 {
AzureIoTClient 28:add19eb7defa 280 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 281 LogError("Cannot allocate memory for body AMQP sequences");
AzureIoTClient 28:add19eb7defa 282 message_destroy(result);
AzureIoTClient 28:add19eb7defa 283 result = NULL;
AzureIoTClient 28:add19eb7defa 284 }
AzureIoTClient 28:add19eb7defa 285 else
AzureIoTClient 28:add19eb7defa 286 {
AzureIoTClient 28:add19eb7defa 287 for (i = 0; i < source_message->body_amqp_sequence_count; i++)
AzureIoTClient 28:add19eb7defa 288 {
AzureIoTClient 28:add19eb7defa 289 /* Codes_SRS_MESSAGE_01_160: [ If AMQP sequences are set as AMQP body they shall be cloned by calling `amqpvalue_clone`. ] */
AzureIoTClient 28:add19eb7defa 290 result->body_amqp_sequence_items[i] = amqpvalue_clone(source_message->body_amqp_sequence_items[i]);
AzureIoTClient 28:add19eb7defa 291 if (result->body_amqp_sequence_items[i] == NULL)
AzureIoTClient 28:add19eb7defa 292 {
AzureIoTClient 28:add19eb7defa 293 LogError("Cannot clone AMQP sequence %u", (unsigned int)i);
AzureIoTClient 28:add19eb7defa 294 break;
AzureIoTClient 28:add19eb7defa 295 }
AzureIoTClient 28:add19eb7defa 296 }
Azure.IoT Build 0:6ae2f7bca550 297
AzureIoTClient 28:add19eb7defa 298 result->body_amqp_sequence_count = i;
AzureIoTClient 28:add19eb7defa 299 if (i < source_message->body_amqp_sequence_count)
AzureIoTClient 28:add19eb7defa 300 {
AzureIoTClient 28:add19eb7defa 301 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 302 message_destroy(result);
AzureIoTClient 28:add19eb7defa 303 result = NULL;
AzureIoTClient 28:add19eb7defa 304 }
AzureIoTClient 28:add19eb7defa 305 }
AzureIoTClient 28:add19eb7defa 306 }
Azure.IoT Build 0:6ae2f7bca550 307
AzureIoTClient 28:add19eb7defa 308 if ((result != NULL) && (source_message->body_amqp_value != NULL))
AzureIoTClient 28:add19eb7defa 309 {
AzureIoTClient 28:add19eb7defa 310 /* Codes_SRS_MESSAGE_01_159: [If an AMQP value has been set as message body on the source message it shall be cloned by calling `amqpvalue_clone`. ]*/
AzureIoTClient 28:add19eb7defa 311 result->body_amqp_value = amqpvalue_clone(source_message->body_amqp_value);
AzureIoTClient 28:add19eb7defa 312 if (result->body_amqp_value == NULL)
AzureIoTClient 28:add19eb7defa 313 {
AzureIoTClient 28:add19eb7defa 314 /* Codes_SRS_MESSAGE_01_012: [ If any cloning operation for the members of the source message fails, then `message_clone` shall fail and return NULL. ]*/
AzureIoTClient 28:add19eb7defa 315 LogError("Cannot clone body AMQP value");
AzureIoTClient 28:add19eb7defa 316 message_destroy(result);
AzureIoTClient 28:add19eb7defa 317 result = NULL;
AzureIoTClient 28:add19eb7defa 318 }
AzureIoTClient 28:add19eb7defa 319 }
AzureIoTClient 28:add19eb7defa 320 }
AzureIoTClient 28:add19eb7defa 321 }
Azure.IoT Build 0:6ae2f7bca550 322
AzureIoTClient 28:add19eb7defa 323 return result;
Azure.IoT Build 0:6ae2f7bca550 324 }
Azure.IoT Build 0:6ae2f7bca550 325
Azure.IoT Build 0:6ae2f7bca550 326 void message_destroy(MESSAGE_HANDLE message)
Azure.IoT Build 0:6ae2f7bca550 327 {
AzureIoTClient 28:add19eb7defa 328 if (message == NULL)
AzureIoTClient 28:add19eb7defa 329 {
AzureIoTClient 28:add19eb7defa 330 /* Codes_SRS_MESSAGE_01_014: [ If `message` is NULL, `message_destroy` shall do nothing. ]*/
AzureIoTClient 28:add19eb7defa 331 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 332 }
AzureIoTClient 28:add19eb7defa 333 else
AzureIoTClient 28:add19eb7defa 334 {
AzureIoTClient 28:add19eb7defa 335 /* Codes_SRS_MESSAGE_01_013: [ `message_destroy` shall free all resources allocated by the message instance identified by the `message` argument. ]*/
AzureIoTClient 28:add19eb7defa 336 if (message->header != NULL)
AzureIoTClient 28:add19eb7defa 337 {
AzureIoTClient 28:add19eb7defa 338 /* Codes_SRS_MESSAGE_01_015: [ The message header shall be freed by calling `header_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 339 header_destroy(message->header);
AzureIoTClient 28:add19eb7defa 340 }
AzureIoTClient 28:add19eb7defa 341
AzureIoTClient 28:add19eb7defa 342 if (message->delivery_annotations != NULL)
AzureIoTClient 28:add19eb7defa 343 {
AzureIoTClient 28:add19eb7defa 344 /* Codes_SRS_MESSAGE_01_016: [ The delivery annotations shall be freed by calling `annotations_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 345 annotations_destroy(message->delivery_annotations);
AzureIoTClient 28:add19eb7defa 346 }
AzureIoTClient 28:add19eb7defa 347
AzureIoTClient 24:2c59c2d43ebf 348 if (message->message_annotations != NULL)
Azure.IoT Build 0:6ae2f7bca550 349 {
AzureIoTClient 28:add19eb7defa 350 /* Codes_SRS_MESSAGE_01_017: [ The message annotations shall be freed by calling `annotations_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 351 annotations_destroy(message->message_annotations);
AzureIoTClient 28:add19eb7defa 352 }
AzureIoTClient 28:add19eb7defa 353
AzureIoTClient 28:add19eb7defa 354 if (message->properties != NULL)
AzureIoTClient 28:add19eb7defa 355 {
AzureIoTClient 28:add19eb7defa 356 /* Codes_SRS_MESSAGE_01_018: [ The message properties shall be freed by calling `properties_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 357 properties_destroy(message->properties);
AzureIoTClient 28:add19eb7defa 358 }
AzureIoTClient 28:add19eb7defa 359
AzureIoTClient 28:add19eb7defa 360 if (message->application_properties != NULL)
AzureIoTClient 28:add19eb7defa 361 {
AzureIoTClient 28:add19eb7defa 362 /* Codes_SRS_MESSAGE_01_019: [ The application properties shall be freed by calling `amqpvalue_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 363 application_properties_destroy(message->application_properties);
Azure.IoT Build 0:6ae2f7bca550 364 }
Azure.IoT Build 0:6ae2f7bca550 365
AzureIoTClient 28:add19eb7defa 366 if (message->footer != NULL)
AzureIoTClient 28:add19eb7defa 367 {
AzureIoTClient 28:add19eb7defa 368 /* Codes_SRS_MESSAGE_01_020: [ The message footer shall be freed by calling `annotations_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 369 annotations_destroy(message->footer);
AzureIoTClient 28:add19eb7defa 370 }
AzureIoTClient 28:add19eb7defa 371
AzureIoTClient 28:add19eb7defa 372 if (message->body_amqp_value != NULL)
AzureIoTClient 28:add19eb7defa 373 {
AzureIoTClient 28:add19eb7defa 374 /* Codes_SRS_MESSAGE_01_021: [ If the message body is made of an AMQP value, the value shall be freed by calling `amqpvalue_destroy`. ]*/
AzureIoTClient 28:add19eb7defa 375 amqpvalue_destroy(message->body_amqp_value);
AzureIoTClient 28:add19eb7defa 376 }
AzureIoTClient 28:add19eb7defa 377
AzureIoTClient 28:add19eb7defa 378 /* Codes_SRS_MESSAGE_01_136: [ If the message body is made of several AMQP data items, they shall all be freed. ]*/
AzureIoTClient 28:add19eb7defa 379 free_all_body_data_items(message);
AzureIoTClient 28:add19eb7defa 380
AzureIoTClient 28:add19eb7defa 381 /* Codes_SRS_MESSAGE_01_136: [ If the message body is made of several AMQP sequences, they shall all be freed. ]*/
AzureIoTClient 28:add19eb7defa 382 free_all_body_sequence_items(message);
AzureIoTClient 28:add19eb7defa 383 free(message);
AzureIoTClient 28:add19eb7defa 384 }
Azure.IoT Build 0:6ae2f7bca550 385 }
Azure.IoT Build 0:6ae2f7bca550 386
Azure.IoT Build 0:6ae2f7bca550 387 int message_set_header(MESSAGE_HANDLE message, HEADER_HANDLE header)
Azure.IoT Build 0:6ae2f7bca550 388 {
AzureIoTClient 28:add19eb7defa 389 int result;
Azure.IoT Build 0:6ae2f7bca550 390
AzureIoTClient 28:add19eb7defa 391 if (message == NULL)
AzureIoTClient 28:add19eb7defa 392 {
AzureIoTClient 28:add19eb7defa 393 /* Codes_SRS_MESSAGE_01_024: [ If `message` is NULL, `message_set_header` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 394 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 395 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 396 }
AzureIoTClient 28:add19eb7defa 397 else
AzureIoTClient 28:add19eb7defa 398 {
AzureIoTClient 28:add19eb7defa 399 HEADER_HANDLE new_header;
AzureIoTClient 28:add19eb7defa 400
AzureIoTClient 28:add19eb7defa 401 if (header == NULL)
AzureIoTClient 28:add19eb7defa 402 {
AzureIoTClient 28:add19eb7defa 403 /* Codes_SRS_MESSAGE_01_139: [ If `message_header` is NULL, the previously stored header associated with `message` shall be freed. ]*/
AzureIoTClient 28:add19eb7defa 404 if (message->header != NULL)
AzureIoTClient 28:add19eb7defa 405 {
AzureIoTClient 28:add19eb7defa 406 header_destroy(message->header);
AzureIoTClient 28:add19eb7defa 407 message->header = NULL;
AzureIoTClient 28:add19eb7defa 408 }
Azure.IoT Build 0:6ae2f7bca550 409
AzureIoTClient 28:add19eb7defa 410 /* Codes_SRS_MESSAGE_01_023: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 411 result = 0;
AzureIoTClient 28:add19eb7defa 412 }
AzureIoTClient 28:add19eb7defa 413 else
AzureIoTClient 28:add19eb7defa 414 {
AzureIoTClient 28:add19eb7defa 415 /* Codes_SRS_MESSAGE_01_022: [ `message_set_header` shall copy the contents of `message_header` as the header for the message instance identified by message. ]*/
AzureIoTClient 28:add19eb7defa 416 /* Codes_SRS_MESSAGE_01_025: [ Cloning the header shall be done by calling `header_clone`. ]*/
AzureIoTClient 28:add19eb7defa 417 new_header = header_clone(header);
AzureIoTClient 28:add19eb7defa 418 if (new_header == NULL)
AzureIoTClient 28:add19eb7defa 419 {
AzureIoTClient 28:add19eb7defa 420 /* Codes_SRS_MESSAGE_01_026: [ If `header_clone` fails, `message_set_header` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 421 LogError("Cannot clone message header");
AzureIoTClient 28:add19eb7defa 422 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 423 }
AzureIoTClient 28:add19eb7defa 424 else
AzureIoTClient 28:add19eb7defa 425 {
AzureIoTClient 28:add19eb7defa 426 /* Codes_SRS_MESSAGE_01_138: [ If setting the header fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 427 /* Only do the free of the previous value if we could clone the new one*/
AzureIoTClient 28:add19eb7defa 428 if (message->header != NULL)
AzureIoTClient 28:add19eb7defa 429 {
AzureIoTClient 28:add19eb7defa 430 header_destroy(message->header);
AzureIoTClient 28:add19eb7defa 431 }
Azure.IoT Build 0:6ae2f7bca550 432
AzureIoTClient 28:add19eb7defa 433 message->header = new_header;
Azure.IoT Build 0:6ae2f7bca550 434
AzureIoTClient 28:add19eb7defa 435 /* Codes_SRS_MESSAGE_01_023: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 436 result = 0;
AzureIoTClient 28:add19eb7defa 437 }
AzureIoTClient 28:add19eb7defa 438 }
AzureIoTClient 28:add19eb7defa 439 }
AzureIoTClient 28:add19eb7defa 440
AzureIoTClient 28:add19eb7defa 441 return result;
Azure.IoT Build 0:6ae2f7bca550 442 }
Azure.IoT Build 0:6ae2f7bca550 443
Azure.IoT Build 0:6ae2f7bca550 444 int message_get_header(MESSAGE_HANDLE message, HEADER_HANDLE* header)
Azure.IoT Build 0:6ae2f7bca550 445 {
AzureIoTClient 28:add19eb7defa 446 int result;
AzureIoTClient 28:add19eb7defa 447
AzureIoTClient 28:add19eb7defa 448 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 449 (header == NULL))
AzureIoTClient 28:add19eb7defa 450 {
AzureIoTClient 28:add19eb7defa 451 /* Codes_SRS_MESSAGE_01_029: [ If `message` or `message_header` is NULL, `message_get_header` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 452 LogError("Bad arguments: message = %p, header = %p",
AzureIoTClient 28:add19eb7defa 453 message, header);
AzureIoTClient 28:add19eb7defa 454 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 455 }
AzureIoTClient 28:add19eb7defa 456 else
AzureIoTClient 28:add19eb7defa 457 {
AzureIoTClient 28:add19eb7defa 458 if (message->header == NULL)
AzureIoTClient 28:add19eb7defa 459 {
AzureIoTClient 28:add19eb7defa 460 /* Codes_SRS_MESSAGE_01_143: [ If no header has been set, `message_get_header` shall set `message_header` to NULL. ]*/
AzureIoTClient 28:add19eb7defa 461 *header = NULL;
Azure.IoT Build 0:6ae2f7bca550 462
AzureIoTClient 28:add19eb7defa 463 /* Codes_SRS_MESSAGE_01_028: [ On success, `message_get_header` shall return 0.]*/
AzureIoTClient 28:add19eb7defa 464 result = 0;
AzureIoTClient 28:add19eb7defa 465 }
AzureIoTClient 28:add19eb7defa 466 else
AzureIoTClient 28:add19eb7defa 467 {
AzureIoTClient 28:add19eb7defa 468 /* Codes_SRS_MESSAGE_01_027: [ `message_get_header` shall copy the contents of header for the message instance identified by `message` into the argument `message_header`. ]*/
AzureIoTClient 28:add19eb7defa 469 /* Codes_SRS_MESSAGE_01_030: [ Cloning the header shall be done by calling `header_clone`. ]*/
AzureIoTClient 28:add19eb7defa 470 *header = header_clone(message->header);
AzureIoTClient 28:add19eb7defa 471 if (*header == NULL)
AzureIoTClient 28:add19eb7defa 472 {
AzureIoTClient 28:add19eb7defa 473 /* Codes_SRS_MESSAGE_01_031: [ If `header_clone` fails, `message_get_header` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 474 LogError("Cannot clone message header");
AzureIoTClient 28:add19eb7defa 475 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 476 }
AzureIoTClient 28:add19eb7defa 477 else
AzureIoTClient 28:add19eb7defa 478 {
AzureIoTClient 28:add19eb7defa 479 /* Codes_SRS_MESSAGE_01_028: [ On success, `message_get_header` shall return 0.]*/
AzureIoTClient 28:add19eb7defa 480 result = 0;
AzureIoTClient 28:add19eb7defa 481 }
AzureIoTClient 28:add19eb7defa 482 }
AzureIoTClient 28:add19eb7defa 483 }
Azure.IoT Build 0:6ae2f7bca550 484
AzureIoTClient 28:add19eb7defa 485 return result;
Azure.IoT Build 0:6ae2f7bca550 486 }
Azure.IoT Build 0:6ae2f7bca550 487
AzureIoTClient 28:add19eb7defa 488 int message_set_delivery_annotations(MESSAGE_HANDLE message, delivery_annotations annotations)
Azure.IoT Build 0:6ae2f7bca550 489 {
AzureIoTClient 28:add19eb7defa 490 int result;
Azure.IoT Build 0:6ae2f7bca550 491
AzureIoTClient 28:add19eb7defa 492 if (message == NULL)
AzureIoTClient 28:add19eb7defa 493 {
AzureIoTClient 28:add19eb7defa 494 /* Codes_SRS_MESSAGE_01_034: [ If `message` is NULL, `message_set_delivery_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 495 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 496 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 497 }
AzureIoTClient 28:add19eb7defa 498 else
AzureIoTClient 28:add19eb7defa 499 {
AzureIoTClient 28:add19eb7defa 500 delivery_annotations new_delivery_annotations;
Azure.IoT Build 0:6ae2f7bca550 501
AzureIoTClient 28:add19eb7defa 502 if (annotations == NULL)
AzureIoTClient 28:add19eb7defa 503 {
AzureIoTClient 28:add19eb7defa 504 /* Codes_SRS_MESSAGE_01_141: [ If `annotations` is NULL, the previously stored delivery annotations associated with `message` shall be freed. ]*/
AzureIoTClient 28:add19eb7defa 505 if (message->delivery_annotations != NULL)
AzureIoTClient 28:add19eb7defa 506 {
AzureIoTClient 28:add19eb7defa 507 annotations_destroy(message->delivery_annotations);
AzureIoTClient 28:add19eb7defa 508 message->delivery_annotations = NULL;
AzureIoTClient 28:add19eb7defa 509 }
AzureIoTClient 46:01f7ca900e07 510
AzureIoTClient 28:add19eb7defa 511 /* Codes_SRS_MESSAGE_01_033: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 512 result = 0;
AzureIoTClient 28:add19eb7defa 513 }
AzureIoTClient 28:add19eb7defa 514 else
AzureIoTClient 28:add19eb7defa 515 {
AzureIoTClient 28:add19eb7defa 516 /* Codes_SRS_MESSAGE_01_032: [ `message_set_delivery_annotations` shall copy the contents of `annotations` as the delivery annotations for the message instance identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 517 /* Codes_SRS_MESSAGE_01_035: [ Cloning the delivery annotations shall be done by calling `annotations_clone`. ]*/
AzureIoTClient 28:add19eb7defa 518 new_delivery_annotations = annotations_clone(annotations);
AzureIoTClient 28:add19eb7defa 519 if (new_delivery_annotations == NULL)
AzureIoTClient 28:add19eb7defa 520 {
AzureIoTClient 28:add19eb7defa 521 /* Codes_SRS_MESSAGE_01_036: [ If `annotations_clone` fails, `message_set_delivery_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 522 LogError("Cannot clone delivery annotations");
AzureIoTClient 28:add19eb7defa 523 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 524 }
AzureIoTClient 28:add19eb7defa 525 else
AzureIoTClient 28:add19eb7defa 526 {
AzureIoTClient 28:add19eb7defa 527 /* Codes_SRS_MESSAGE_01_140: [** If setting the delivery annotations fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 528 /* Only do the free of the previous value if we could clone the new one*/
AzureIoTClient 28:add19eb7defa 529 if (message->delivery_annotations != NULL)
AzureIoTClient 28:add19eb7defa 530 {
AzureIoTClient 28:add19eb7defa 531 annotations_destroy(message->delivery_annotations);
AzureIoTClient 28:add19eb7defa 532 }
AzureIoTClient 24:2c59c2d43ebf 533
AzureIoTClient 28:add19eb7defa 534 message->delivery_annotations = new_delivery_annotations;
Azure.IoT Build 0:6ae2f7bca550 535
AzureIoTClient 28:add19eb7defa 536 /* Codes_SRS_MESSAGE_01_033: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 537 result = 0;
AzureIoTClient 28:add19eb7defa 538 }
AzureIoTClient 28:add19eb7defa 539 }
AzureIoTClient 28:add19eb7defa 540 }
AzureIoTClient 28:add19eb7defa 541
AzureIoTClient 28:add19eb7defa 542 return result;
Azure.IoT Build 0:6ae2f7bca550 543 }
Azure.IoT Build 0:6ae2f7bca550 544
AzureIoTClient 28:add19eb7defa 545 int message_get_delivery_annotations(MESSAGE_HANDLE message, delivery_annotations* annotations)
Azure.IoT Build 0:6ae2f7bca550 546 {
AzureIoTClient 28:add19eb7defa 547 int result;
AzureIoTClient 28:add19eb7defa 548
AzureIoTClient 28:add19eb7defa 549 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 550 (annotations == NULL))
AzureIoTClient 28:add19eb7defa 551 {
AzureIoTClient 28:add19eb7defa 552 /* Codes_SRS_MESSAGE_01_039: [ If `message` or `annotations` is NULL, `message_get_delivery_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 553 LogError("Bad arguments: message = %p, annotations = %p",
AzureIoTClient 28:add19eb7defa 554 message, annotations);
AzureIoTClient 28:add19eb7defa 555 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 556 }
AzureIoTClient 28:add19eb7defa 557 else
AzureIoTClient 28:add19eb7defa 558 {
AzureIoTClient 28:add19eb7defa 559 if (message->delivery_annotations == NULL)
AzureIoTClient 28:add19eb7defa 560 {
AzureIoTClient 28:add19eb7defa 561 /* Codes_SRS_MESSAGE_01_142: [ If no delivery annotations have been set, `message_get_delivery_annotations` shall set `annotations` to NULL. ]*/
AzureIoTClient 28:add19eb7defa 562 *annotations = NULL;
Azure.IoT Build 0:6ae2f7bca550 563
AzureIoTClient 28:add19eb7defa 564 /* Codes_SRS_MESSAGE_01_038: [ On success, `message_get_delivery_annotations` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 565 result = 0;
AzureIoTClient 28:add19eb7defa 566 }
AzureIoTClient 28:add19eb7defa 567 else
AzureIoTClient 28:add19eb7defa 568 {
AzureIoTClient 28:add19eb7defa 569 /* Codes_SRS_MESSAGE_01_037: [ `message_get_delivery_annotations` shall copy the contents of delivery annotations for the message instance identified by `message` into the argument `annotations`. ]*/
AzureIoTClient 28:add19eb7defa 570 /* Codes_SRS_MESSAGE_01_040: [ Cloning the delivery annotations shall be done by calling `annotations_clone`. ]*/
AzureIoTClient 28:add19eb7defa 571 *annotations = annotations_clone(message->delivery_annotations);
AzureIoTClient 28:add19eb7defa 572 if (*annotations == NULL)
AzureIoTClient 28:add19eb7defa 573 {
AzureIoTClient 28:add19eb7defa 574 /* Codes_SRS_MESSAGE_01_041: [ If `annotations_clone` fails, `message_get_delivery_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 575 LogError("Cannot clone delivery annotations");
AzureIoTClient 28:add19eb7defa 576 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 577 }
AzureIoTClient 28:add19eb7defa 578 else
AzureIoTClient 28:add19eb7defa 579 {
AzureIoTClient 28:add19eb7defa 580 /* Codes_SRS_MESSAGE_01_038: [ On success, `message_get_delivery_annotations` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 581 result = 0;
AzureIoTClient 28:add19eb7defa 582 }
AzureIoTClient 28:add19eb7defa 583 }
AzureIoTClient 28:add19eb7defa 584 }
Azure.IoT Build 0:6ae2f7bca550 585
AzureIoTClient 28:add19eb7defa 586 return result;
Azure.IoT Build 0:6ae2f7bca550 587 }
Azure.IoT Build 0:6ae2f7bca550 588
AzureIoTClient 28:add19eb7defa 589 int message_set_message_annotations(MESSAGE_HANDLE message, message_annotations annotations)
Azure.IoT Build 0:6ae2f7bca550 590 {
AzureIoTClient 28:add19eb7defa 591 int result;
Azure.IoT Build 0:6ae2f7bca550 592
AzureIoTClient 28:add19eb7defa 593 if (message == NULL)
AzureIoTClient 28:add19eb7defa 594 {
AzureIoTClient 28:add19eb7defa 595 /* Codes_SRS_MESSAGE_01_044: [ If `message` is NULL, `message_set_message_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 596 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 597 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 598 }
AzureIoTClient 28:add19eb7defa 599 else
AzureIoTClient 28:add19eb7defa 600 {
AzureIoTClient 28:add19eb7defa 601 if (annotations == NULL)
AzureIoTClient 28:add19eb7defa 602 {
AzureIoTClient 28:add19eb7defa 603 /* Codes_SRS_MESSAGE_01_145: [ If `annotations` is NULL, the previously stored message annotations associated with `message` shall be freed. ]*/
AzureIoTClient 28:add19eb7defa 604 if (message->message_annotations != NULL)
AzureIoTClient 28:add19eb7defa 605 {
AzureIoTClient 28:add19eb7defa 606 annotations_destroy(message->message_annotations);
AzureIoTClient 28:add19eb7defa 607 message->message_annotations = NULL;
AzureIoTClient 28:add19eb7defa 608 }
AzureIoTClient 28:add19eb7defa 609
AzureIoTClient 28:add19eb7defa 610 /* Codes_SRS_MESSAGE_01_043: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 611 result = 0;
AzureIoTClient 28:add19eb7defa 612 }
AzureIoTClient 28:add19eb7defa 613 else
AzureIoTClient 28:add19eb7defa 614 {
AzureIoTClient 28:add19eb7defa 615 message_annotations new_message_annotations;
Azure.IoT Build 0:6ae2f7bca550 616
AzureIoTClient 28:add19eb7defa 617 /* Codes_SRS_MESSAGE_01_042: [ `message_set_message_annotations` shall copy the contents of `annotations` as the message annotations for the message instance identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 618 /* Codes_SRS_MESSAGE_01_045: [ Cloning the message annotations shall be done by calling `annotations_clone`. ]*/
AzureIoTClient 28:add19eb7defa 619 new_message_annotations = annotations_clone(annotations);
AzureIoTClient 28:add19eb7defa 620 if (new_message_annotations == NULL)
AzureIoTClient 28:add19eb7defa 621 {
AzureIoTClient 28:add19eb7defa 622 /* Codes_SRS_MESSAGE_01_046: [ If `annotations_clone` fails, `message_set_message_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 623 LogError("Cannot clone message annotations");
AzureIoTClient 28:add19eb7defa 624 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 625 }
AzureIoTClient 28:add19eb7defa 626 else
AzureIoTClient 28:add19eb7defa 627 {
AzureIoTClient 28:add19eb7defa 628 /* Codes_SRS_MESSAGE_01_144: [ If setting the message annotations fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 629 /* Only do the free of the previous value if we could clone the new one*/
AzureIoTClient 28:add19eb7defa 630 if (message->message_annotations != NULL)
AzureIoTClient 28:add19eb7defa 631 {
AzureIoTClient 28:add19eb7defa 632 annotations_destroy(message->message_annotations);
AzureIoTClient 28:add19eb7defa 633 }
Azure.IoT Build 0:6ae2f7bca550 634
AzureIoTClient 28:add19eb7defa 635 message->message_annotations = new_message_annotations;
Azure.IoT Build 0:6ae2f7bca550 636
AzureIoTClient 28:add19eb7defa 637 /* Codes_SRS_MESSAGE_01_043: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 638 result = 0;
AzureIoTClient 28:add19eb7defa 639 }
AzureIoTClient 28:add19eb7defa 640 }
AzureIoTClient 28:add19eb7defa 641 }
AzureIoTClient 28:add19eb7defa 642
AzureIoTClient 28:add19eb7defa 643 return result;
Azure.IoT Build 0:6ae2f7bca550 644 }
Azure.IoT Build 0:6ae2f7bca550 645
Azure.IoT Build 0:6ae2f7bca550 646 int message_get_message_annotations(MESSAGE_HANDLE message, annotations* message_annotations)
Azure.IoT Build 0:6ae2f7bca550 647 {
AzureIoTClient 28:add19eb7defa 648 int result;
AzureIoTClient 28:add19eb7defa 649
AzureIoTClient 28:add19eb7defa 650 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 651 (message_annotations == NULL))
AzureIoTClient 28:add19eb7defa 652 {
AzureIoTClient 28:add19eb7defa 653 /* Codes_SRS_MESSAGE_01_049: [ If `message` or `annotations` is NULL, `message_get_message_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 654 LogError("Bad arguments: message = %p, message_annotations = %p",
AzureIoTClient 28:add19eb7defa 655 message, message_annotations);
AzureIoTClient 28:add19eb7defa 656 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 657 }
AzureIoTClient 28:add19eb7defa 658 else
AzureIoTClient 28:add19eb7defa 659 {
AzureIoTClient 28:add19eb7defa 660 if (message->message_annotations == NULL)
AzureIoTClient 28:add19eb7defa 661 {
AzureIoTClient 28:add19eb7defa 662 /* Codes_SRS_MESSAGE_01_146: [ If no message annotations have been set, `message_get_message_annotations` shall set `annotations` to NULL. ]*/
AzureIoTClient 28:add19eb7defa 663 *message_annotations = NULL;
Azure.IoT Build 0:6ae2f7bca550 664
AzureIoTClient 28:add19eb7defa 665 /* Codes_SRS_MESSAGE_01_048: [ On success, `message_get_message_annotations` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 666 result = 0;
AzureIoTClient 28:add19eb7defa 667 }
AzureIoTClient 28:add19eb7defa 668 else
AzureIoTClient 28:add19eb7defa 669 {
AzureIoTClient 28:add19eb7defa 670 /* Codes_SRS_MESSAGE_01_047: [ `message_get_message_annotations` shall copy the contents of message annotations for the message instance identified by `message` into the argument `annotations`. ]*/
AzureIoTClient 28:add19eb7defa 671 /* Codes_SRS_MESSAGE_01_050: [ Cloning the message annotations shall be done by calling `annotations_clone`. ]*/
AzureIoTClient 28:add19eb7defa 672 *message_annotations = annotations_clone(message->message_annotations);
AzureIoTClient 28:add19eb7defa 673 if (*message_annotations == NULL)
AzureIoTClient 28:add19eb7defa 674 {
AzureIoTClient 28:add19eb7defa 675 /* Codes_SRS_MESSAGE_01_051: [ If `annotations_clone` fails, `message_get_message_annotations` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 676 LogError("Cannot clone message annotations");
AzureIoTClient 28:add19eb7defa 677 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 678 }
AzureIoTClient 28:add19eb7defa 679 else
AzureIoTClient 28:add19eb7defa 680 {
AzureIoTClient 28:add19eb7defa 681 /* Codes_SRS_MESSAGE_01_048: [ On success, `message_get_message_annotations` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 682 result = 0;
AzureIoTClient 28:add19eb7defa 683 }
AzureIoTClient 28:add19eb7defa 684 }
AzureIoTClient 28:add19eb7defa 685 }
Azure.IoT Build 0:6ae2f7bca550 686
AzureIoTClient 28:add19eb7defa 687 return result;
Azure.IoT Build 0:6ae2f7bca550 688 }
Azure.IoT Build 0:6ae2f7bca550 689
Azure.IoT Build 0:6ae2f7bca550 690 int message_set_properties(MESSAGE_HANDLE message, PROPERTIES_HANDLE properties)
Azure.IoT Build 0:6ae2f7bca550 691 {
AzureIoTClient 28:add19eb7defa 692 int result;
Azure.IoT Build 0:6ae2f7bca550 693
AzureIoTClient 28:add19eb7defa 694 if (message == NULL)
AzureIoTClient 28:add19eb7defa 695 {
AzureIoTClient 28:add19eb7defa 696 /* Codes_SRS_MESSAGE_01_054: [ If `message` is NULL, `message_set_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 697 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 698 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 699 }
AzureIoTClient 28:add19eb7defa 700 else
AzureIoTClient 28:add19eb7defa 701 {
AzureIoTClient 28:add19eb7defa 702 if (properties == NULL)
AzureIoTClient 28:add19eb7defa 703 {
AzureIoTClient 28:add19eb7defa 704 /* Codes_SRS_MESSAGE_01_147: [ If `properties` is NULL, the previously stored message properties associated with `message` shall be freed. ]*/
AzureIoTClient 28:add19eb7defa 705 if (message->properties != NULL)
AzureIoTClient 28:add19eb7defa 706 {
AzureIoTClient 28:add19eb7defa 707 properties_destroy(message->properties);
AzureIoTClient 28:add19eb7defa 708 message->properties = NULL;
AzureIoTClient 28:add19eb7defa 709 }
AzureIoTClient 28:add19eb7defa 710
AzureIoTClient 28:add19eb7defa 711 /* Codes_SRS_MESSAGE_01_053: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 712 result = 0;
AzureIoTClient 28:add19eb7defa 713 }
AzureIoTClient 28:add19eb7defa 714 else
AzureIoTClient 28:add19eb7defa 715 {
AzureIoTClient 28:add19eb7defa 716 PROPERTIES_HANDLE new_properties;
Azure.IoT Build 0:6ae2f7bca550 717
AzureIoTClient 28:add19eb7defa 718 /* Codes_SRS_MESSAGE_01_052: [ `message_set_properties` shall copy the contents of `properties` as the message properties for the message instance identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 719 /* Codes_SRS_MESSAGE_01_055: [ Cloning the message properties shall be done by calling `properties_clone`. ]*/
AzureIoTClient 28:add19eb7defa 720 new_properties = properties_clone(properties);
AzureIoTClient 28:add19eb7defa 721 if (new_properties == NULL)
AzureIoTClient 28:add19eb7defa 722 {
AzureIoTClient 28:add19eb7defa 723 /* Codes_SRS_MESSAGE_01_056: [ If `properties_clone` fails, `message_set_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 724 LogError("Cannot clone message properties");
AzureIoTClient 28:add19eb7defa 725 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 726 }
AzureIoTClient 28:add19eb7defa 727 else
AzureIoTClient 28:add19eb7defa 728 {
AzureIoTClient 28:add19eb7defa 729 /* Codes_SRS_MESSAGE_01_063: [ If setting the message properties fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 730 /* Only do the free of the previous value if we could clone the new one*/
AzureIoTClient 28:add19eb7defa 731 if (message->properties != NULL)
AzureIoTClient 28:add19eb7defa 732 {
AzureIoTClient 28:add19eb7defa 733 properties_destroy(message->properties);
AzureIoTClient 28:add19eb7defa 734 }
Azure.IoT Build 0:6ae2f7bca550 735
AzureIoTClient 28:add19eb7defa 736 message->properties = new_properties;
Azure.IoT Build 0:6ae2f7bca550 737
AzureIoTClient 28:add19eb7defa 738 /* Codes_SRS_MESSAGE_01_053: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 739 result = 0;
AzureIoTClient 28:add19eb7defa 740 }
AzureIoTClient 28:add19eb7defa 741 }
AzureIoTClient 28:add19eb7defa 742 }
AzureIoTClient 28:add19eb7defa 743
AzureIoTClient 28:add19eb7defa 744 return result;
Azure.IoT Build 0:6ae2f7bca550 745 }
Azure.IoT Build 0:6ae2f7bca550 746
Azure.IoT Build 0:6ae2f7bca550 747 int message_get_properties(MESSAGE_HANDLE message, PROPERTIES_HANDLE* properties)
Azure.IoT Build 0:6ae2f7bca550 748 {
AzureIoTClient 28:add19eb7defa 749 int result;
AzureIoTClient 28:add19eb7defa 750
AzureIoTClient 28:add19eb7defa 751 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 752 (properties == NULL))
AzureIoTClient 28:add19eb7defa 753 {
AzureIoTClient 28:add19eb7defa 754 /* Codes_SRS_MESSAGE_01_059: [ If `message` or `properties` is NULL, `message_get_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 755 LogError("Bad arguments: message = %p, properties = %p",
AzureIoTClient 28:add19eb7defa 756 message, properties);
AzureIoTClient 28:add19eb7defa 757 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 758 }
AzureIoTClient 28:add19eb7defa 759 else
AzureIoTClient 28:add19eb7defa 760 {
AzureIoTClient 28:add19eb7defa 761 if (message->properties == NULL)
AzureIoTClient 28:add19eb7defa 762 {
AzureIoTClient 28:add19eb7defa 763 /* Codes_SRS_MESSAGE_01_148: [ If no message properties have been set, `message_get_properties` shall set `properties` to NULL. ]*/
AzureIoTClient 28:add19eb7defa 764 *properties = NULL;
Azure.IoT Build 0:6ae2f7bca550 765
AzureIoTClient 28:add19eb7defa 766 /* Codes_SRS_MESSAGE_01_058: [ On success, `message_get_properties` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 767 result = 0;
AzureIoTClient 28:add19eb7defa 768 }
AzureIoTClient 28:add19eb7defa 769 else
AzureIoTClient 28:add19eb7defa 770 {
AzureIoTClient 28:add19eb7defa 771 /* Codes_SRS_MESSAGE_01_057: [ `message_get_properties` shall copy the contents of message properties for the message instance identified by `message` into the argument `properties`. ]*/
AzureIoTClient 28:add19eb7defa 772 /* Codes_SRS_MESSAGE_01_060: [ Cloning the message properties shall be done by calling `properties_clone`. ]*/
AzureIoTClient 28:add19eb7defa 773 *properties = properties_clone(message->properties);
AzureIoTClient 28:add19eb7defa 774 if (*properties == NULL)
AzureIoTClient 28:add19eb7defa 775 {
AzureIoTClient 28:add19eb7defa 776 /* Codes_SRS_MESSAGE_01_061: [ If `properties_clone` fails, `message_get_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 777 LogError("Cannot clone message properties");
AzureIoTClient 28:add19eb7defa 778 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 779 }
AzureIoTClient 28:add19eb7defa 780 else
AzureIoTClient 28:add19eb7defa 781 {
AzureIoTClient 28:add19eb7defa 782 /* Codes_SRS_MESSAGE_01_058: [ On success, `message_get_properties` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 783 result = 0;
AzureIoTClient 28:add19eb7defa 784 }
AzureIoTClient 28:add19eb7defa 785 }
AzureIoTClient 28:add19eb7defa 786 }
Azure.IoT Build 0:6ae2f7bca550 787
AzureIoTClient 28:add19eb7defa 788 return result;
Azure.IoT Build 0:6ae2f7bca550 789 }
Azure.IoT Build 0:6ae2f7bca550 790
Azure.IoT Build 0:6ae2f7bca550 791 int message_set_application_properties(MESSAGE_HANDLE message, AMQP_VALUE application_properties)
Azure.IoT Build 0:6ae2f7bca550 792 {
AzureIoTClient 28:add19eb7defa 793 int result;
Azure.IoT Build 0:6ae2f7bca550 794
AzureIoTClient 28:add19eb7defa 795 if (message == NULL)
AzureIoTClient 28:add19eb7defa 796 {
AzureIoTClient 28:add19eb7defa 797 /* Codes_SRS_MESSAGE_01_066: [ If `message` is NULL, `message_set_application_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 798 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 799 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 800 }
AzureIoTClient 28:add19eb7defa 801 else
AzureIoTClient 28:add19eb7defa 802 {
AzureIoTClient 28:add19eb7defa 803 AMQP_VALUE new_application_properties;
AzureIoTClient 28:add19eb7defa 804
AzureIoTClient 28:add19eb7defa 805 /* Tests_SRS_MESSAGE_01_149: [ If `application_properties` is NULL, the previously stored application properties associated with `message` shall be freed. ]*/
AzureIoTClient 28:add19eb7defa 806 if (application_properties == NULL)
AzureIoTClient 28:add19eb7defa 807 {
AzureIoTClient 28:add19eb7defa 808 if (message->application_properties != NULL)
AzureIoTClient 28:add19eb7defa 809 {
AzureIoTClient 28:add19eb7defa 810 amqpvalue_destroy(message->application_properties);
AzureIoTClient 28:add19eb7defa 811 message->application_properties = NULL;
AzureIoTClient 28:add19eb7defa 812 }
Azure.IoT Build 0:6ae2f7bca550 813
AzureIoTClient 28:add19eb7defa 814 /* Codes_SRS_MESSAGE_01_065: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 815 result = 0;
AzureIoTClient 28:add19eb7defa 816 }
AzureIoTClient 28:add19eb7defa 817 else
AzureIoTClient 28:add19eb7defa 818 {
AzureIoTClient 28:add19eb7defa 819 /* Codes_SRS_MESSAGE_01_064: [ `message_set_application_properties` shall copy the contents of `application_properties` as the application properties for the message instance identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 820 /* Codes_SRS_MESSAGE_01_067: [ Cloning the message properties shall be done by calling `application_properties_clone`. ]*/
AzureIoTClient 28:add19eb7defa 821 new_application_properties = application_properties_clone(application_properties);
AzureIoTClient 28:add19eb7defa 822 if (new_application_properties == NULL)
AzureIoTClient 28:add19eb7defa 823 {
AzureIoTClient 28:add19eb7defa 824 /* Codes_SRS_MESSAGE_01_068: [ If `application_properties_clone` fails, `message_set_application_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 825 LogError("Cannot clone application properties");
AzureIoTClient 28:add19eb7defa 826 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 827 }
AzureIoTClient 28:add19eb7defa 828 else
AzureIoTClient 28:add19eb7defa 829 {
AzureIoTClient 28:add19eb7defa 830 /* Codes_SRS_MESSAGE_01_069: [ If setting the application properties fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 831 /* Only do the free of the previous value if we could clone the new one*/
AzureIoTClient 28:add19eb7defa 832 if (message->application_properties != NULL)
AzureIoTClient 28:add19eb7defa 833 {
AzureIoTClient 28:add19eb7defa 834 amqpvalue_destroy(message->application_properties);
AzureIoTClient 28:add19eb7defa 835 }
Azure.IoT Build 0:6ae2f7bca550 836
AzureIoTClient 28:add19eb7defa 837 message->application_properties = new_application_properties;
Azure.IoT Build 0:6ae2f7bca550 838
AzureIoTClient 28:add19eb7defa 839 /* Codes_SRS_MESSAGE_01_065: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 840 result = 0;
AzureIoTClient 28:add19eb7defa 841 }
AzureIoTClient 28:add19eb7defa 842 }
AzureIoTClient 28:add19eb7defa 843 }
AzureIoTClient 28:add19eb7defa 844
AzureIoTClient 28:add19eb7defa 845 return result;
Azure.IoT Build 0:6ae2f7bca550 846 }
Azure.IoT Build 0:6ae2f7bca550 847
Azure.IoT Build 0:6ae2f7bca550 848 int message_get_application_properties(MESSAGE_HANDLE message, AMQP_VALUE* application_properties)
Azure.IoT Build 0:6ae2f7bca550 849 {
AzureIoTClient 28:add19eb7defa 850 int result;
AzureIoTClient 28:add19eb7defa 851
AzureIoTClient 28:add19eb7defa 852 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 853 (application_properties == NULL))
AzureIoTClient 28:add19eb7defa 854 {
AzureIoTClient 28:add19eb7defa 855 /* Codes_SRS_MESSAGE_01_072: [ If `message` or `application_properties` is NULL, `message_get_application_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 856 LogError("Bad arguments: message = %p, application_properties = %p",
AzureIoTClient 28:add19eb7defa 857 message, application_properties);
AzureIoTClient 28:add19eb7defa 858 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 859 }
AzureIoTClient 28:add19eb7defa 860 else
AzureIoTClient 28:add19eb7defa 861 {
AzureIoTClient 28:add19eb7defa 862 if (message->application_properties == NULL)
AzureIoTClient 28:add19eb7defa 863 {
AzureIoTClient 28:add19eb7defa 864 /* Codes_SRS_MESSAGE_01_150: [ If no application properties have been set, `message_get_application_properties` shall set `application_properties` to NULL. ]*/
AzureIoTClient 28:add19eb7defa 865 *application_properties = NULL;
Azure.IoT Build 0:6ae2f7bca550 866
AzureIoTClient 28:add19eb7defa 867 /* Codes_SRS_MESSAGE_01_071: [ On success, `message_get_application_properties` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 868 result = 0;
AzureIoTClient 28:add19eb7defa 869 }
AzureIoTClient 28:add19eb7defa 870 else
AzureIoTClient 28:add19eb7defa 871 {
AzureIoTClient 28:add19eb7defa 872 /* Codes_SRS_MESSAGE_01_070: [ `message_get_application_properties` shall copy the contents of application message properties for the message instance identified by `message` into the argument `application_properties`. ]*/
AzureIoTClient 28:add19eb7defa 873 /* Codes_SRS_MESSAGE_01_073: [ Cloning the application properties shall be done by calling `application_properties_clone`. ]*/
AzureIoTClient 28:add19eb7defa 874 *application_properties = application_properties_clone(message->application_properties);
AzureIoTClient 28:add19eb7defa 875 if (*application_properties == NULL)
AzureIoTClient 28:add19eb7defa 876 {
AzureIoTClient 28:add19eb7defa 877 /* Codes_SRS_MESSAGE_01_074: [ If `application_properties_clone` fails, `message_get_application_properties` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 878 LogError("Cannot clone application properties");
AzureIoTClient 28:add19eb7defa 879 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 880 }
AzureIoTClient 28:add19eb7defa 881 else
AzureIoTClient 28:add19eb7defa 882 {
AzureIoTClient 28:add19eb7defa 883 /* Codes_SRS_MESSAGE_01_071: [ On success, `message_get_application_properties` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 884 result = 0;
AzureIoTClient 28:add19eb7defa 885 }
AzureIoTClient 28:add19eb7defa 886 }
AzureIoTClient 28:add19eb7defa 887 }
Azure.IoT Build 0:6ae2f7bca550 888
AzureIoTClient 28:add19eb7defa 889 return result;
Azure.IoT Build 0:6ae2f7bca550 890 }
Azure.IoT Build 0:6ae2f7bca550 891
Azure.IoT Build 0:6ae2f7bca550 892 int message_set_footer(MESSAGE_HANDLE message, annotations footer)
Azure.IoT Build 0:6ae2f7bca550 893 {
AzureIoTClient 28:add19eb7defa 894 int result;
Azure.IoT Build 0:6ae2f7bca550 895
AzureIoTClient 28:add19eb7defa 896 if (message == NULL)
AzureIoTClient 28:add19eb7defa 897 {
AzureIoTClient 28:add19eb7defa 898 /* Codes_SRS_MESSAGE_01_077: [ If `message` is NULL, `message_set_footer` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 899 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 900 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 901 }
AzureIoTClient 28:add19eb7defa 902 else
AzureIoTClient 28:add19eb7defa 903 {
AzureIoTClient 28:add19eb7defa 904 if (footer == NULL)
AzureIoTClient 28:add19eb7defa 905 {
AzureIoTClient 28:add19eb7defa 906 /* Codes_SRS_MESSAGE_01_151: [ If `footer` is NULL, the previously stored footer associated with `message` shall be freed. ]*/
AzureIoTClient 28:add19eb7defa 907 if (message->footer != NULL)
AzureIoTClient 28:add19eb7defa 908 {
AzureIoTClient 28:add19eb7defa 909 annotations_destroy(message->footer);
AzureIoTClient 28:add19eb7defa 910 message->footer = NULL;
AzureIoTClient 28:add19eb7defa 911 }
AzureIoTClient 28:add19eb7defa 912
AzureIoTClient 28:add19eb7defa 913 /* Codes_SRS_MESSAGE_01_076: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 914 result = 0;
AzureIoTClient 28:add19eb7defa 915 }
AzureIoTClient 28:add19eb7defa 916 else
AzureIoTClient 28:add19eb7defa 917 {
AzureIoTClient 28:add19eb7defa 918 annotations new_footer;
Azure.IoT Build 0:6ae2f7bca550 919
AzureIoTClient 28:add19eb7defa 920 /* Codes_SRS_MESSAGE_01_075: [ `message_set_footer` shall copy the contents of `footer` as the footer contents for the message instance identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 921 /* Codes_SRS_MESSAGE_01_078: [ Cloning the footer shall be done by calling `annotations_clone`. ]*/
AzureIoTClient 28:add19eb7defa 922 new_footer = annotations_clone(footer);
AzureIoTClient 28:add19eb7defa 923 if (new_footer == NULL)
AzureIoTClient 28:add19eb7defa 924 {
AzureIoTClient 28:add19eb7defa 925 /* Codes_SRS_MESSAGE_01_079: [ If `annotations_clone` fails, `message_set_footer` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 926 LogError("Cannot clone message footer");
AzureIoTClient 28:add19eb7defa 927 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 928 }
AzureIoTClient 28:add19eb7defa 929 else
AzureIoTClient 28:add19eb7defa 930 {
AzureIoTClient 28:add19eb7defa 931 /* Codes_SRS_MESSAGE_01_080: [ If setting the footer fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 932 /* Only do the free of the previous value if we could clone the new one*/
AzureIoTClient 28:add19eb7defa 933 if (message->footer != NULL)
AzureIoTClient 28:add19eb7defa 934 {
AzureIoTClient 28:add19eb7defa 935 annotations_destroy(message->footer);
AzureIoTClient 28:add19eb7defa 936 }
Azure.IoT Build 0:6ae2f7bca550 937
AzureIoTClient 28:add19eb7defa 938 message->footer = new_footer;
Azure.IoT Build 0:6ae2f7bca550 939
AzureIoTClient 28:add19eb7defa 940 /* Codes_SRS_MESSAGE_01_076: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 941 result = 0;
AzureIoTClient 28:add19eb7defa 942 }
AzureIoTClient 28:add19eb7defa 943 }
AzureIoTClient 28:add19eb7defa 944 }
AzureIoTClient 28:add19eb7defa 945
AzureIoTClient 28:add19eb7defa 946 return result;
Azure.IoT Build 0:6ae2f7bca550 947 }
Azure.IoT Build 0:6ae2f7bca550 948
Azure.IoT Build 0:6ae2f7bca550 949 int message_get_footer(MESSAGE_HANDLE message, annotations* footer)
Azure.IoT Build 0:6ae2f7bca550 950 {
AzureIoTClient 28:add19eb7defa 951 int result;
AzureIoTClient 28:add19eb7defa 952
AzureIoTClient 28:add19eb7defa 953 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 954 (footer == NULL))
AzureIoTClient 28:add19eb7defa 955 {
AzureIoTClient 28:add19eb7defa 956 /* Codes_SRS_MESSAGE_01_083: [ If `message` or `footer` is NULL, `message_get_footer` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 957 LogError("Bad arguments: message = %p, footer = %p",
AzureIoTClient 28:add19eb7defa 958 message, footer);
AzureIoTClient 28:add19eb7defa 959 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 960 }
AzureIoTClient 28:add19eb7defa 961 else
AzureIoTClient 28:add19eb7defa 962 {
AzureIoTClient 28:add19eb7defa 963 if (message->footer == NULL)
AzureIoTClient 28:add19eb7defa 964 {
AzureIoTClient 28:add19eb7defa 965 /* Codes_SRS_MESSAGE_01_152: [ If no footer has been set, `message_get_footer` shall set `footer` to NULL. ]*/
AzureIoTClient 28:add19eb7defa 966 *footer = NULL;
Azure.IoT Build 0:6ae2f7bca550 967
AzureIoTClient 28:add19eb7defa 968 /* Codes_SRS_MESSAGE_01_082: [ On success, `message_get_footer` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 969 result = 0;
AzureIoTClient 28:add19eb7defa 970 }
AzureIoTClient 28:add19eb7defa 971 else
AzureIoTClient 28:add19eb7defa 972 {
AzureIoTClient 28:add19eb7defa 973 /* Codes_SRS_MESSAGE_01_081: [ `message_get_footer` shall copy the contents of footer for the message instance identified by `message` into the argument `footer`. ]*/
AzureIoTClient 28:add19eb7defa 974 /* Codes_SRS_MESSAGE_01_084: [ Cloning the footer shall be done by calling `annotations_clone`. ]*/
AzureIoTClient 28:add19eb7defa 975 *footer = annotations_clone(message->footer);
AzureIoTClient 28:add19eb7defa 976 if (*footer == NULL)
AzureIoTClient 28:add19eb7defa 977 {
AzureIoTClient 28:add19eb7defa 978 /* Codes_SRS_MESSAGE_01_085: [ If `annotations_clone` fails, `message_get_footer` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 979 LogError("Cannot clone message footer");
AzureIoTClient 28:add19eb7defa 980 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 981 }
AzureIoTClient 28:add19eb7defa 982 else
AzureIoTClient 28:add19eb7defa 983 {
AzureIoTClient 28:add19eb7defa 984 /* Codes_SRS_MESSAGE_01_082: [ On success, `message_get_footer` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 985 result = 0;
AzureIoTClient 28:add19eb7defa 986 }
AzureIoTClient 28:add19eb7defa 987 }
AzureIoTClient 28:add19eb7defa 988 }
Azure.IoT Build 0:6ae2f7bca550 989
AzureIoTClient 28:add19eb7defa 990 return result;
Azure.IoT Build 0:6ae2f7bca550 991 }
Azure.IoT Build 0:6ae2f7bca550 992
AzureIoTClient 24:2c59c2d43ebf 993 int message_add_body_amqp_data(MESSAGE_HANDLE message, BINARY_DATA amqp_data)
Azure.IoT Build 0:6ae2f7bca550 994 {
AzureIoTClient 28:add19eb7defa 995 int result;
Azure.IoT Build 0:6ae2f7bca550 996
AzureIoTClient 28:add19eb7defa 997 /* Codes_SRS_MESSAGE_01_088: [ If `message` is NULL, `message_add_body_amqp_data` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 998 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 999 /* Tests_SRS_MESSAGE_01_089: [ If the `bytes` member of `amqp_data` is NULL and the `size` member is non-zero, `message_add_body_amqp_data` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1000 ((amqp_data.bytes == NULL) &&
AzureIoTClient 28:add19eb7defa 1001 (amqp_data.length != 0)))
AzureIoTClient 28:add19eb7defa 1002 {
AzureIoTClient 28:add19eb7defa 1003 LogError("Bad arguments: message = %p, bytes = %p, length = %u",
AzureIoTClient 28:add19eb7defa 1004 message, amqp_data.bytes, (unsigned int)amqp_data.length);
AzureIoTClient 28:add19eb7defa 1005 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1006 }
AzureIoTClient 28:add19eb7defa 1007 else
AzureIoTClient 28:add19eb7defa 1008 {
AzureIoTClient 28:add19eb7defa 1009 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1010 if ((body_type == MESSAGE_BODY_TYPE_SEQUENCE) ||
AzureIoTClient 28:add19eb7defa 1011 (body_type == MESSAGE_BODY_TYPE_VALUE))
AzureIoTClient 28:add19eb7defa 1012 {
AzureIoTClient 28:add19eb7defa 1013 /* Codes_SRS_MESSAGE_01_091: [ If the body was already set to an AMQP value or a list of AMQP sequences, `message_add_body_amqp_data` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1014 LogError("Body type already set");
AzureIoTClient 28:add19eb7defa 1015 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1016 }
AzureIoTClient 28:add19eb7defa 1017 else
AzureIoTClient 28:add19eb7defa 1018 {
AzureIoTClient 28:add19eb7defa 1019 /* Codes_SRS_MESSAGE_01_086: [ `message_add_body_amqp_data` shall add the contents of `amqp_data` to the list of AMQP data values for the body of the message identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 1020 BODY_AMQP_DATA* new_body_amqp_data_items = (BODY_AMQP_DATA*)realloc(message->body_amqp_data_items, sizeof(BODY_AMQP_DATA) * (message->body_amqp_data_count + 1));
AzureIoTClient 28:add19eb7defa 1021 if (new_body_amqp_data_items == NULL)
AzureIoTClient 28:add19eb7defa 1022 {
AzureIoTClient 28:add19eb7defa 1023 /* Codes_SRS_MESSAGE_01_153: [ If allocating memory to store the added AMQP data fails, `message_add_body_amqp_data` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1024 LogError("Cannot allocate memory for body AMQP data items");
AzureIoTClient 28:add19eb7defa 1025 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1026 }
AzureIoTClient 28:add19eb7defa 1027 else
AzureIoTClient 28:add19eb7defa 1028 {
AzureIoTClient 28:add19eb7defa 1029 message->body_amqp_data_items = new_body_amqp_data_items;
Azure.IoT Build 0:6ae2f7bca550 1030
AzureIoTClient 40:f0ceafa8d570 1031 if (amqp_data.length == 0)
AzureIoTClient 28:add19eb7defa 1032 {
AzureIoTClient 40:f0ceafa8d570 1033 message->body_amqp_data_items[message->body_amqp_data_count].body_data_section_bytes = NULL;
AzureIoTClient 40:f0ceafa8d570 1034 message->body_amqp_data_items[message->body_amqp_data_count].body_data_section_length = 0;
AzureIoTClient 28:add19eb7defa 1035 message->body_amqp_data_count++;
Azure.IoT Build 0:6ae2f7bca550 1036
AzureIoTClient 28:add19eb7defa 1037 /* Codes_SRS_MESSAGE_01_087: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1038 result = 0;
AzureIoTClient 28:add19eb7defa 1039 }
AzureIoTClient 40:f0ceafa8d570 1040 else
AzureIoTClient 40:f0ceafa8d570 1041 {
AzureIoTClient 40:f0ceafa8d570 1042 message->body_amqp_data_items[message->body_amqp_data_count].body_data_section_bytes = (unsigned char*)malloc(amqp_data.length);
AzureIoTClient 40:f0ceafa8d570 1043 if (message->body_amqp_data_items[message->body_amqp_data_count].body_data_section_bytes == NULL)
AzureIoTClient 40:f0ceafa8d570 1044 {
AzureIoTClient 40:f0ceafa8d570 1045 /* Codes_SRS_MESSAGE_01_153: [ If allocating memory to store the added AMQP data fails, `message_add_body_amqp_data` shall fail and return a non-zero value. ]*/
AzureIoTClient 40:f0ceafa8d570 1046 LogError("Cannot allocate memory for body AMQP data to be added");
AzureIoTClient 40:f0ceafa8d570 1047 result = __FAILURE__;
AzureIoTClient 40:f0ceafa8d570 1048 }
AzureIoTClient 40:f0ceafa8d570 1049 else
AzureIoTClient 40:f0ceafa8d570 1050 {
AzureIoTClient 40:f0ceafa8d570 1051 message->body_amqp_data_items[message->body_amqp_data_count].body_data_section_length = amqp_data.length;
AzureIoTClient 40:f0ceafa8d570 1052 (void)memcpy(message->body_amqp_data_items[message->body_amqp_data_count].body_data_section_bytes, amqp_data.bytes, amqp_data.length);
AzureIoTClient 40:f0ceafa8d570 1053 message->body_amqp_data_count++;
AzureIoTClient 40:f0ceafa8d570 1054
AzureIoTClient 40:f0ceafa8d570 1055 /* Codes_SRS_MESSAGE_01_087: [ On success it shall return 0. ]*/
AzureIoTClient 40:f0ceafa8d570 1056 result = 0;
AzureIoTClient 40:f0ceafa8d570 1057 }
AzureIoTClient 40:f0ceafa8d570 1058 }
AzureIoTClient 28:add19eb7defa 1059 }
AzureIoTClient 28:add19eb7defa 1060 }
AzureIoTClient 28:add19eb7defa 1061 }
Azure.IoT Build 0:6ae2f7bca550 1062
AzureIoTClient 28:add19eb7defa 1063 return result;
Azure.IoT Build 0:6ae2f7bca550 1064 }
Azure.IoT Build 0:6ae2f7bca550 1065
AzureIoTClient 28:add19eb7defa 1066 int message_get_body_amqp_data_in_place(MESSAGE_HANDLE message, size_t index, BINARY_DATA* amqp_data)
Azure.IoT Build 0:6ae2f7bca550 1067 {
AzureIoTClient 28:add19eb7defa 1068 int result;
Azure.IoT Build 0:6ae2f7bca550 1069
AzureIoTClient 28:add19eb7defa 1070 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1071 (amqp_data == NULL))
AzureIoTClient 28:add19eb7defa 1072 {
AzureIoTClient 28:add19eb7defa 1073 /* Codes_SRS_MESSAGE_01_094: [ If `message` or `amqp_data` is NULL, `message_get_body_amqp_data_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1074 LogError("Bad arguments: message = %p, amqp_data = %p",
AzureIoTClient 28:add19eb7defa 1075 message, amqp_data);
AzureIoTClient 28:add19eb7defa 1076 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1077 }
AzureIoTClient 28:add19eb7defa 1078 else
AzureIoTClient 28:add19eb7defa 1079 {
AzureIoTClient 28:add19eb7defa 1080 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1081 if (body_type != MESSAGE_BODY_TYPE_DATA)
AzureIoTClient 28:add19eb7defa 1082 {
AzureIoTClient 28:add19eb7defa 1083 /* Codes_SRS_MESSAGE_01_096: [ If the body for `message` is not of type `MESSAGE_BODY_TYPE_DATA`, `message_get_body_amqp_data_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1084 LogError("Body type is not AMQP data");
AzureIoTClient 28:add19eb7defa 1085 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1086 }
AzureIoTClient 28:add19eb7defa 1087 else if (index >= message->body_amqp_data_count)
AzureIoTClient 28:add19eb7defa 1088 {
AzureIoTClient 28:add19eb7defa 1089 /* Codes_SRS_MESSAGE_01_095: [ If `index` indicates an AMQP data entry that is out of bounds, `message_get_body_amqp_data_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1090 LogError("Index too high for AMQP data (%u), number of AMQP data entries is %u",
AzureIoTClient 28:add19eb7defa 1091 index, message->body_amqp_data_count);
AzureIoTClient 28:add19eb7defa 1092 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1093 }
AzureIoTClient 28:add19eb7defa 1094 else
AzureIoTClient 28:add19eb7defa 1095 {
AzureIoTClient 28:add19eb7defa 1096 /* Codes_SRS_MESSAGE_01_092: [ `message_get_body_amqp_data_in_place` shall place the contents of the `index`th AMQP data for the message instance identified by `message` into the argument `amqp_data`, without copying the binary payload memory. ]*/
AzureIoTClient 28:add19eb7defa 1097 amqp_data->bytes = message->body_amqp_data_items[index].body_data_section_bytes;
AzureIoTClient 28:add19eb7defa 1098 amqp_data->length = message->body_amqp_data_items[index].body_data_section_length;
Azure.IoT Build 0:6ae2f7bca550 1099
AzureIoTClient 28:add19eb7defa 1100 /* Codes_SRS_MESSAGE_01_093: [ On success, `message_get_body_amqp_data_in_place` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1101 result = 0;
AzureIoTClient 28:add19eb7defa 1102 }
AzureIoTClient 28:add19eb7defa 1103 }
Azure.IoT Build 0:6ae2f7bca550 1104
AzureIoTClient 28:add19eb7defa 1105 return result;
Azure.IoT Build 0:6ae2f7bca550 1106 }
Azure.IoT Build 0:6ae2f7bca550 1107
Azure.IoT Build 0:6ae2f7bca550 1108 int message_get_body_amqp_data_count(MESSAGE_HANDLE message, size_t* count)
Azure.IoT Build 0:6ae2f7bca550 1109 {
AzureIoTClient 28:add19eb7defa 1110 int result;
AzureIoTClient 28:add19eb7defa 1111
AzureIoTClient 28:add19eb7defa 1112 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1113 (count == NULL))
AzureIoTClient 28:add19eb7defa 1114 {
AzureIoTClient 28:add19eb7defa 1115 /* Codes_SRS_MESSAGE_01_099: [ If `message` or `count` is NULL, `message_get_body_amqp_data_count` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1116 LogError("Bad arguments: message = %p, count = %p",
AzureIoTClient 28:add19eb7defa 1117 message, count);
AzureIoTClient 28:add19eb7defa 1118 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1119 }
AzureIoTClient 28:add19eb7defa 1120 else
AzureIoTClient 28:add19eb7defa 1121 {
AzureIoTClient 28:add19eb7defa 1122 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1123 if (body_type != MESSAGE_BODY_TYPE_DATA)
AzureIoTClient 28:add19eb7defa 1124 {
AzureIoTClient 28:add19eb7defa 1125 /* Codes_SRS_MESSAGE_01_100: [ If the body for `message` is not of type `MESSAGE_BODY_TYPE_DATA`, `message_get_body_amqp_data_count` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1126 LogError("Body type is not AMQP data");
AzureIoTClient 28:add19eb7defa 1127 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1128 }
AzureIoTClient 28:add19eb7defa 1129 else
AzureIoTClient 28:add19eb7defa 1130 {
AzureIoTClient 28:add19eb7defa 1131 /* Codes_SRS_MESSAGE_01_097: [ `message_get_body_amqp_data_count` shall fill in `count` the number of AMQP data chunks that are stored by the message identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 1132 *count = message->body_amqp_data_count;
AzureIoTClient 28:add19eb7defa 1133
AzureIoTClient 28:add19eb7defa 1134 /* Codes_SRS_MESSAGE_01_098: [ On success, `message_get_body_amqp_data_count` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1135 result = 0;
AzureIoTClient 28:add19eb7defa 1136 }
AzureIoTClient 28:add19eb7defa 1137 }
AzureIoTClient 28:add19eb7defa 1138
AzureIoTClient 28:add19eb7defa 1139 return result;
AzureIoTClient 28:add19eb7defa 1140 }
AzureIoTClient 28:add19eb7defa 1141
AzureIoTClient 28:add19eb7defa 1142 int message_set_body_amqp_value(MESSAGE_HANDLE message, AMQP_VALUE body_amqp_value)
AzureIoTClient 28:add19eb7defa 1143 {
AzureIoTClient 28:add19eb7defa 1144 int result;
Azure.IoT Build 0:6ae2f7bca550 1145
AzureIoTClient 28:add19eb7defa 1146 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1147 (body_amqp_value == NULL))
AzureIoTClient 28:add19eb7defa 1148 {
AzureIoTClient 28:add19eb7defa 1149 /* Codes_SRS_MESSAGE_01_103: [ If `message` or `body_amqp_value` is NULL, `message_set_body_amqp_value` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1150 LogError("Bad arguments: message = %p, body_amqp_value = %p",
AzureIoTClient 28:add19eb7defa 1151 message, body_amqp_value);
AzureIoTClient 28:add19eb7defa 1152 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1153 }
AzureIoTClient 28:add19eb7defa 1154 else
AzureIoTClient 28:add19eb7defa 1155 {
AzureIoTClient 28:add19eb7defa 1156 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1157 if ((body_type == MESSAGE_BODY_TYPE_DATA) ||
AzureIoTClient 28:add19eb7defa 1158 (body_type == MESSAGE_BODY_TYPE_SEQUENCE))
AzureIoTClient 28:add19eb7defa 1159 {
AzureIoTClient 28:add19eb7defa 1160 /* Codes_SRS_MESSAGE_01_105: [ If the body was already set to an AMQP data list or a list of AMQP sequences, `message_set_body_amqp_value` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1161 LogError("Body is already set to another body type");
AzureIoTClient 28:add19eb7defa 1162 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1163 }
AzureIoTClient 28:add19eb7defa 1164 else
AzureIoTClient 28:add19eb7defa 1165 {
AzureIoTClient 28:add19eb7defa 1166 /* Codes_SRS_MESSAGE_01_154: [ Cloning the amqp value shall be done by calling `amqpvalue_clone`. ]*/
AzureIoTClient 28:add19eb7defa 1167 AMQP_VALUE new_amqp_value = amqpvalue_clone(body_amqp_value);
AzureIoTClient 28:add19eb7defa 1168 if (new_amqp_value == NULL)
AzureIoTClient 28:add19eb7defa 1169 {
AzureIoTClient 28:add19eb7defa 1170 LogError("Cannot clone body AMQP value",
AzureIoTClient 28:add19eb7defa 1171 message, body_amqp_value);
AzureIoTClient 28:add19eb7defa 1172 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1173 }
AzureIoTClient 28:add19eb7defa 1174 else
AzureIoTClient 28:add19eb7defa 1175 {
AzureIoTClient 28:add19eb7defa 1176 /* Codes_SRS_MESSAGE_01_104: [ If setting the body AMQP value fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 1177 /* Only free the previous value when cloning is succesfull */
AzureIoTClient 28:add19eb7defa 1178 if (message->body_amqp_value != NULL)
AzureIoTClient 28:add19eb7defa 1179 {
AzureIoTClient 28:add19eb7defa 1180 amqpvalue_destroy(body_amqp_value);
AzureIoTClient 28:add19eb7defa 1181 }
AzureIoTClient 28:add19eb7defa 1182
AzureIoTClient 28:add19eb7defa 1183 /* Codes_SRS_MESSAGE_01_101: [ `message_set_body_amqp_value` shall set the contents of body as being the AMQP value indicate by `body_amqp_value`. ]*/
AzureIoTClient 28:add19eb7defa 1184 message->body_amqp_value = new_amqp_value;
Azure.IoT Build 0:6ae2f7bca550 1185
AzureIoTClient 28:add19eb7defa 1186 /* Codes_SRS_MESSAGE_01_102: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1187 result = 0;
AzureIoTClient 28:add19eb7defa 1188 }
AzureIoTClient 28:add19eb7defa 1189 }
AzureIoTClient 28:add19eb7defa 1190 }
AzureIoTClient 28:add19eb7defa 1191
AzureIoTClient 28:add19eb7defa 1192 return result;
AzureIoTClient 28:add19eb7defa 1193 }
AzureIoTClient 28:add19eb7defa 1194
AzureIoTClient 28:add19eb7defa 1195 int message_get_body_amqp_value_in_place(MESSAGE_HANDLE message, AMQP_VALUE* body_amqp_value)
AzureIoTClient 28:add19eb7defa 1196 {
AzureIoTClient 28:add19eb7defa 1197 int result;
AzureIoTClient 28:add19eb7defa 1198
AzureIoTClient 28:add19eb7defa 1199 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1200 (body_amqp_value == NULL))
AzureIoTClient 28:add19eb7defa 1201 {
AzureIoTClient 28:add19eb7defa 1202 /* Codes_SRS_MESSAGE_01_108: [ If `message` or `body_amqp_value` is NULL, `message_get_body_amqp_value_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1203 LogError("Bad arguments: message = %p, body_amqp_value = %p",
AzureIoTClient 28:add19eb7defa 1204 message, body_amqp_value);
AzureIoTClient 28:add19eb7defa 1205 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1206 }
AzureIoTClient 28:add19eb7defa 1207 else
AzureIoTClient 28:add19eb7defa 1208 {
AzureIoTClient 28:add19eb7defa 1209 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1210 if (body_type != MESSAGE_BODY_TYPE_VALUE)
AzureIoTClient 28:add19eb7defa 1211 {
AzureIoTClient 28:add19eb7defa 1212 /* Codes_SRS_MESSAGE_01_109: [ If the body for `message` is not of type `MESSAGE_BODY_TYPE_VALUE`, `message_get_body_amqp_value_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1213 LogError("Body is not of type AMQP value");
AzureIoTClient 28:add19eb7defa 1214 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1215 }
AzureIoTClient 28:add19eb7defa 1216 else
AzureIoTClient 28:add19eb7defa 1217 {
AzureIoTClient 28:add19eb7defa 1218 /* Codes_SRS_MESSAGE_01_106: [ `message_get_body_amqp_value_in_place` shall get the body AMQP value for the message instance identified by `message` in place (not cloning) into the `body_amqp_value` argument. ]*/
AzureIoTClient 28:add19eb7defa 1219 *body_amqp_value = message->body_amqp_value;
AzureIoTClient 28:add19eb7defa 1220
AzureIoTClient 28:add19eb7defa 1221 /* Codes_SRS_MESSAGE_01_107: [ On success, `message_get_body_amqp_value_in_place` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1222 result = 0;
AzureIoTClient 28:add19eb7defa 1223 }
AzureIoTClient 28:add19eb7defa 1224 }
AzureIoTClient 28:add19eb7defa 1225
AzureIoTClient 28:add19eb7defa 1226 return result;
Azure.IoT Build 0:6ae2f7bca550 1227 }
Azure.IoT Build 0:6ae2f7bca550 1228
Azure.IoT Build 0:6ae2f7bca550 1229 int message_add_body_amqp_sequence(MESSAGE_HANDLE message, AMQP_VALUE sequence_list)
Azure.IoT Build 0:6ae2f7bca550 1230 {
AzureIoTClient 28:add19eb7defa 1231 int result;
Azure.IoT Build 0:6ae2f7bca550 1232
AzureIoTClient 28:add19eb7defa 1233 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1234 (sequence_list == NULL))
AzureIoTClient 28:add19eb7defa 1235 {
AzureIoTClient 28:add19eb7defa 1236 /* Codes_SRS_MESSAGE_01_112: [ If `message` or `sequence` is NULL, `message_add_body_amqp_sequence` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1237 LogError("Bad arguments: message = %p, sequence_list = %p",
AzureIoTClient 28:add19eb7defa 1238 message, sequence_list);
AzureIoTClient 28:add19eb7defa 1239 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1240 }
AzureIoTClient 28:add19eb7defa 1241 else
AzureIoTClient 28:add19eb7defa 1242 {
AzureIoTClient 28:add19eb7defa 1243 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1244 if ((body_type == MESSAGE_BODY_TYPE_DATA) ||
AzureIoTClient 28:add19eb7defa 1245 (body_type == MESSAGE_BODY_TYPE_VALUE))
AzureIoTClient 28:add19eb7defa 1246 {
AzureIoTClient 28:add19eb7defa 1247 /* Codes_SRS_MESSAGE_01_115: [ If the body was already set to an AMQP data list or an AMQP value, `message_add_body_amqp_sequence` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1248 LogError("Body is already set to another body type");
AzureIoTClient 28:add19eb7defa 1249 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1250 }
AzureIoTClient 28:add19eb7defa 1251 else
AzureIoTClient 28:add19eb7defa 1252 {
AzureIoTClient 28:add19eb7defa 1253 AMQP_VALUE* new_body_amqp_sequence_items = (AMQP_VALUE*)realloc(message->body_amqp_sequence_items, sizeof(AMQP_VALUE) * (message->body_amqp_sequence_count + 1));
AzureIoTClient 28:add19eb7defa 1254 if (new_body_amqp_sequence_items == NULL)
AzureIoTClient 28:add19eb7defa 1255 {
AzureIoTClient 28:add19eb7defa 1256 /* Codes_SRS_MESSAGE_01_158: [ If allocating memory in order to store the sequence fails, `message_add_body_amqp_sequence` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1257 LogError("Cannot allocate enough memory for sequence items");
AzureIoTClient 28:add19eb7defa 1258 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1259 }
AzureIoTClient 28:add19eb7defa 1260 else
AzureIoTClient 28:add19eb7defa 1261 {
AzureIoTClient 28:add19eb7defa 1262 message->body_amqp_sequence_items = new_body_amqp_sequence_items;
Azure.IoT Build 0:6ae2f7bca550 1263
AzureIoTClient 28:add19eb7defa 1264 /* Codes_SRS_MESSAGE_01_110: [ `message_add_body_amqp_sequence` shall add the contents of `sequence` to the list of AMQP sequences for the body of the message identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 1265 /* Codes_SRS_MESSAGE_01_156: [ The AMQP sequence shall be cloned by calling `amqpvalue_clone`. ]*/
AzureIoTClient 28:add19eb7defa 1266 message->body_amqp_sequence_items[message->body_amqp_sequence_count] = amqpvalue_clone(sequence_list);
AzureIoTClient 28:add19eb7defa 1267 if (message->body_amqp_sequence_items[message->body_amqp_sequence_count] == NULL)
AzureIoTClient 28:add19eb7defa 1268 {
AzureIoTClient 28:add19eb7defa 1269 /* Codes_SRS_MESSAGE_01_157: [ If `amqpvalue_clone` fails, `message_add_body_amqp_sequence` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1270 LogError("Cloning sequence failed");
AzureIoTClient 28:add19eb7defa 1271 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1272 }
AzureIoTClient 28:add19eb7defa 1273 else
AzureIoTClient 28:add19eb7defa 1274 {
AzureIoTClient 28:add19eb7defa 1275 /* Codes_SRS_MESSAGE_01_114: [ If adding the AMQP sequence fails, the previous value shall be preserved. ]*/
AzureIoTClient 28:add19eb7defa 1276 message->body_amqp_sequence_count++;
Azure.IoT Build 0:6ae2f7bca550 1277
AzureIoTClient 28:add19eb7defa 1278 /* Codes_SRS_MESSAGE_01_111: [ On success it shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1279 result = 0;
AzureIoTClient 28:add19eb7defa 1280 }
AzureIoTClient 28:add19eb7defa 1281 }
AzureIoTClient 28:add19eb7defa 1282 }
AzureIoTClient 28:add19eb7defa 1283 }
Azure.IoT Build 0:6ae2f7bca550 1284
AzureIoTClient 28:add19eb7defa 1285 return result;
Azure.IoT Build 0:6ae2f7bca550 1286 }
Azure.IoT Build 0:6ae2f7bca550 1287
AzureIoTClient 28:add19eb7defa 1288 int message_get_body_amqp_sequence_in_place(MESSAGE_HANDLE message, size_t index, AMQP_VALUE* sequence)
Azure.IoT Build 0:6ae2f7bca550 1289 {
AzureIoTClient 28:add19eb7defa 1290 int result;
Azure.IoT Build 0:6ae2f7bca550 1291
AzureIoTClient 28:add19eb7defa 1292 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1293 (sequence == NULL))
AzureIoTClient 28:add19eb7defa 1294 {
AzureIoTClient 28:add19eb7defa 1295 /* Codes_SRS_MESSAGE_01_118: [ If `message` or `sequence` is NULL, `message_get_body_amqp_sequence_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1296 LogError("Bad arguments: message = %p, sequence = %p",
AzureIoTClient 28:add19eb7defa 1297 message, sequence);
AzureIoTClient 28:add19eb7defa 1298 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1299 }
AzureIoTClient 28:add19eb7defa 1300 else
AzureIoTClient 28:add19eb7defa 1301 {
AzureIoTClient 28:add19eb7defa 1302 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1303 if (body_type != MESSAGE_BODY_TYPE_SEQUENCE)
AzureIoTClient 28:add19eb7defa 1304 {
AzureIoTClient 28:add19eb7defa 1305 /* Codes_SRS_MESSAGE_01_120: [ If the body for `message` is not of type `MESSAGE_BODY_TYPE_SEQUENCE`, `message_get_body_amqp_sequence_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1306 LogError("Body is not of type SEQUENCE");
AzureIoTClient 28:add19eb7defa 1307 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1308 }
AzureIoTClient 28:add19eb7defa 1309 else
AzureIoTClient 28:add19eb7defa 1310 {
AzureIoTClient 28:add19eb7defa 1311 if (index >= message->body_amqp_sequence_count)
AzureIoTClient 28:add19eb7defa 1312 {
AzureIoTClient 28:add19eb7defa 1313 /* Codes_SRS_MESSAGE_01_119: [ If `index` indicates an AMQP sequence entry that is out of bounds, `message_get_body_amqp_sequence_in_place` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1314 LogError("Index too high for AMQP sequence (%u), maximum is %u",
AzureIoTClient 28:add19eb7defa 1315 index, message->body_amqp_sequence_count);
AzureIoTClient 28:add19eb7defa 1316 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1317 }
AzureIoTClient 28:add19eb7defa 1318 else
AzureIoTClient 28:add19eb7defa 1319 {
AzureIoTClient 28:add19eb7defa 1320 /* Codes_SRS_MESSAGE_01_116: [ `message_get_body_amqp_sequence_in_place` shall return in `sequence` the content of the `index`th AMQP seuquence entry for the message instance identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 1321 *sequence = message->body_amqp_sequence_items[index];
Azure.IoT Build 0:6ae2f7bca550 1322
AzureIoTClient 28:add19eb7defa 1323 /* Codes_SRS_MESSAGE_01_117: [ On success, `message_get_body_amqp_sequence_in_place` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1324 result = 0;
AzureIoTClient 28:add19eb7defa 1325 }
AzureIoTClient 28:add19eb7defa 1326 }
AzureIoTClient 28:add19eb7defa 1327 }
AzureIoTClient 28:add19eb7defa 1328
AzureIoTClient 28:add19eb7defa 1329 return result;
Azure.IoT Build 0:6ae2f7bca550 1330 }
Azure.IoT Build 0:6ae2f7bca550 1331
Azure.IoT Build 0:6ae2f7bca550 1332 int message_get_body_amqp_sequence_count(MESSAGE_HANDLE message, size_t* count)
Azure.IoT Build 0:6ae2f7bca550 1333 {
AzureIoTClient 28:add19eb7defa 1334 int result;
Azure.IoT Build 0:6ae2f7bca550 1335
AzureIoTClient 28:add19eb7defa 1336 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1337 (count == NULL))
AzureIoTClient 28:add19eb7defa 1338 {
AzureIoTClient 28:add19eb7defa 1339 /* Codes_SRS_MESSAGE_01_123: [ If `message` or `count` is NULL, `message_get_body_amqp_sequence_count` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1340 LogError("Bad arguments: message = %p, count = %p",
AzureIoTClient 28:add19eb7defa 1341 message, count);
AzureIoTClient 28:add19eb7defa 1342 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1343 }
AzureIoTClient 28:add19eb7defa 1344 else
AzureIoTClient 28:add19eb7defa 1345 {
AzureIoTClient 28:add19eb7defa 1346 MESSAGE_BODY_TYPE body_type = internal_get_body_type(message);
AzureIoTClient 28:add19eb7defa 1347 if (body_type != MESSAGE_BODY_TYPE_SEQUENCE)
AzureIoTClient 28:add19eb7defa 1348 {
AzureIoTClient 28:add19eb7defa 1349 /* Codes_SRS_MESSAGE_01_124: [ If the body for `message` is not of type `MESSAGE_BODY_TYPE_SEQUENCE`, `message_get_body_amqp_sequence_count` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1350 LogError("Body is not of type SEQUENCE");
AzureIoTClient 28:add19eb7defa 1351 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1352 }
AzureIoTClient 28:add19eb7defa 1353 else
AzureIoTClient 28:add19eb7defa 1354 {
AzureIoTClient 28:add19eb7defa 1355 /* Codes_SRS_MESSAGE_01_121: [ `message_get_body_amqp_sequence_count` shall fill in `count` the number of AMQP sequences that are stored by the message identified by `message`. ]*/
AzureIoTClient 28:add19eb7defa 1356 *count = message->body_amqp_sequence_count;
Azure.IoT Build 0:6ae2f7bca550 1357
AzureIoTClient 28:add19eb7defa 1358 /* Codes_SRS_MESSAGE_01_122: [ On success, `message_get_body_amqp_sequence_count` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1359 result = 0;
AzureIoTClient 28:add19eb7defa 1360 }
AzureIoTClient 28:add19eb7defa 1361 }
Azure.IoT Build 0:6ae2f7bca550 1362
AzureIoTClient 28:add19eb7defa 1363 return result;
Azure.IoT Build 0:6ae2f7bca550 1364 }
Azure.IoT Build 0:6ae2f7bca550 1365
Azure.IoT Build 0:6ae2f7bca550 1366 int message_get_body_type(MESSAGE_HANDLE message, MESSAGE_BODY_TYPE* body_type)
Azure.IoT Build 0:6ae2f7bca550 1367 {
AzureIoTClient 28:add19eb7defa 1368 int result;
Azure.IoT Build 0:6ae2f7bca550 1369
AzureIoTClient 28:add19eb7defa 1370 if ((message == NULL) ||
AzureIoTClient 28:add19eb7defa 1371 (body_type == NULL))
AzureIoTClient 28:add19eb7defa 1372 {
AzureIoTClient 28:add19eb7defa 1373 /* Codes_SRS_MESSAGE_01_127: [ If `message` or `body_type` is NULL, `message_get_body_type` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1374 LogError("Bad arguments: message = %p, body_type = %p",
AzureIoTClient 28:add19eb7defa 1375 message, body_type);
AzureIoTClient 28:add19eb7defa 1376 result = __FAILURE__;
AzureIoTClient 28:add19eb7defa 1377 }
AzureIoTClient 28:add19eb7defa 1378 else
AzureIoTClient 28:add19eb7defa 1379 {
AzureIoTClient 28:add19eb7defa 1380 /* Codes_SRS_MESSAGE_01_125: [ `message_get_body_type` shall fill in `body_type` the AMQP message body type. ]*/
AzureIoTClient 28:add19eb7defa 1381 if (message->body_amqp_value != NULL)
AzureIoTClient 28:add19eb7defa 1382 {
AzureIoTClient 28:add19eb7defa 1383 *body_type = MESSAGE_BODY_TYPE_VALUE;
AzureIoTClient 28:add19eb7defa 1384 }
AzureIoTClient 28:add19eb7defa 1385 else if (message->body_amqp_data_count > 0)
AzureIoTClient 28:add19eb7defa 1386 {
AzureIoTClient 28:add19eb7defa 1387 *body_type = MESSAGE_BODY_TYPE_DATA;
AzureIoTClient 28:add19eb7defa 1388 }
AzureIoTClient 28:add19eb7defa 1389 else if (message->body_amqp_sequence_count > 0)
AzureIoTClient 28:add19eb7defa 1390 {
AzureIoTClient 28:add19eb7defa 1391 *body_type = MESSAGE_BODY_TYPE_SEQUENCE;
AzureIoTClient 28:add19eb7defa 1392 }
AzureIoTClient 28:add19eb7defa 1393 else
AzureIoTClient 28:add19eb7defa 1394 {
AzureIoTClient 28:add19eb7defa 1395 /* Codes_SRS_MESSAGE_01_128: [ If no body has been set on the message, `body_type` shall be `MESSAGE_BODY_TYPE_NONE`. ]*/
AzureIoTClient 28:add19eb7defa 1396 *body_type = MESSAGE_BODY_TYPE_NONE;
AzureIoTClient 28:add19eb7defa 1397 }
Azure.IoT Build 0:6ae2f7bca550 1398
AzureIoTClient 28:add19eb7defa 1399 /* Codes_SRS_MESSAGE_01_126: [ On success, `message_get_body_type` shall return 0. ]*/
AzureIoTClient 28:add19eb7defa 1400 result = 0;
AzureIoTClient 28:add19eb7defa 1401 }
Azure.IoT Build 0:6ae2f7bca550 1402
AzureIoTClient 28:add19eb7defa 1403 return result;
Azure.IoT Build 0:6ae2f7bca550 1404 }
Azure.IoT Build 0:6ae2f7bca550 1405
Azure.IoT Build 0:6ae2f7bca550 1406 int message_set_message_format(MESSAGE_HANDLE message, uint32_t message_format)
Azure.IoT Build 0:6ae2f7bca550 1407 {
Azure.IoT Build 0:6ae2f7bca550 1408 int result;
Azure.IoT Build 0:6ae2f7bca550 1409
Azure.IoT Build 0:6ae2f7bca550 1410 if (message == NULL)
Azure.IoT Build 0:6ae2f7bca550 1411 {
AzureIoTClient 28:add19eb7defa 1412 /* Codes_SRS_MESSAGE_01_131: [ If `message` is NULL, `message_set_message_format` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1413 LogError("NULL message");
AzureIoTClient 28:add19eb7defa 1414 result = __FAILURE__;
Azure.IoT Build 0:6ae2f7bca550 1415 }
Azure.IoT Build 0:6ae2f7bca550 1416 else
Azure.IoT Build 0:6ae2f7bca550 1417 {
AzureIoTClient 28:add19eb7defa 1418 /* Codes_SRS_MESSAGE_01_129: [ `message_set_message_format` shall set the message format for the message identified by `message`. ]*/
AzureIoTClient 24:2c59c2d43ebf 1419 message->message_format = message_format;
AzureIoTClient 28:add19eb7defa 1420
AzureIoTClient 28:add19eb7defa 1421 /* Codes_SRS_MESSAGE_01_130: [ On success, `message_set_message_format` shall return 0. ]*/
Azure.IoT Build 0:6ae2f7bca550 1422 result = 0;
Azure.IoT Build 0:6ae2f7bca550 1423 }
Azure.IoT Build 0:6ae2f7bca550 1424
Azure.IoT Build 0:6ae2f7bca550 1425 return result;
Azure.IoT Build 0:6ae2f7bca550 1426 }
Azure.IoT Build 0:6ae2f7bca550 1427
Azure.IoT Build 0:6ae2f7bca550 1428 int message_get_message_format(MESSAGE_HANDLE message, uint32_t *message_format)
Azure.IoT Build 0:6ae2f7bca550 1429 {
Azure.IoT Build 0:6ae2f7bca550 1430 int result;
Azure.IoT Build 0:6ae2f7bca550 1431
Azure.IoT Build 0:6ae2f7bca550 1432 if ((message == NULL) ||
Azure.IoT Build 0:6ae2f7bca550 1433 (message_format == NULL))
Azure.IoT Build 0:6ae2f7bca550 1434 {
AzureIoTClient 28:add19eb7defa 1435 /* Codes_SRS_MESSAGE_01_134: [ If `message` or `message_format` is NULL, `message_get_message_format` shall fail and return a non-zero value. ]*/
AzureIoTClient 28:add19eb7defa 1436 LogError("Bad arguments: message = %p, message_format = %p",
AzureIoTClient 28:add19eb7defa 1437 message, message_format);
AzureIoTClient 28:add19eb7defa 1438 result = __FAILURE__;
Azure.IoT Build 0:6ae2f7bca550 1439 }
Azure.IoT Build 0:6ae2f7bca550 1440 else
Azure.IoT Build 0:6ae2f7bca550 1441 {
AzureIoTClient 28:add19eb7defa 1442 /* Codes_SRS_MESSAGE_01_132: [ `message_get_message_format` shall get the message format for the message identified by `message` and return it in the `message_fomrat` argument. ]*/
AzureIoTClient 24:2c59c2d43ebf 1443 *message_format = message->message_format;
AzureIoTClient 28:add19eb7defa 1444
AzureIoTClient 28:add19eb7defa 1445 /* Codes_SRS_MESSAGE_01_133: [ On success, `message_get_message_format` shall return 0. ]*/
Azure.IoT Build 0:6ae2f7bca550 1446 result = 0;
Azure.IoT Build 0:6ae2f7bca550 1447 }
Azure.IoT Build 0:6ae2f7bca550 1448
Azure.IoT Build 0:6ae2f7bca550 1449 return result;
Azure.IoT Build 0:6ae2f7bca550 1450 }