Library that implements the CellularInterface using PPP and LWIP on the mbed MCU. May be used on the C027 and C030 (non-N2xx flavour) boards from mbed 5.5 onwards.
Dependents: example-ublox-cellular-interface HelloMQTT example-ublox-cellular-interface_r410M example-ublox-mbed-client
TESTS/unit_tests/default/template_mbed_app.txt
- Committer:
- rob.meades@u-blox.com
- Date:
- 2017-06-15
- Revision:
- 1:80ec3fccad9e
- Parent:
- 0:44dd95724bc2
File content as of revision 1:80ec3fccad9e:
{ "config": { "debug-on": { "help": "Set to true to get AT interface debug", "value": false }, "run-sim-pin-change-tests": { "help": "If 1, run the SIM PIN change tests, for which default-pin must be defined", "value": 0 }, "default-pin": { "help": "The current value of the SIM PIN as a string; if PIN is enabled on your SIM, or you wish to run the SIM PIN change tests, you must put the PIN for your SIM here", "value": "\"1234\"" }, "apn": { "help": "The APN string to use for this SIM/network, set to 0 if none", "value": 0 }, "username": { "help": "The user name string to use for this APN, set to zero if none", "value": 0 }, "password": { "help": "The password string to use for this APN, set to 0 if none", "value": 0 }, "alt-pin": { "help": "The SIM PIN (as a string) that will be used for SIM PIN change tests (the SIM PIN will be changed back to default-pin afterwards)", "value": "\"9876\"" }, "incorrect-pin": { "help": "A SIM PIN (as a string) that should not be the same as default-pin or alt-pin", "value": "\"1530\"" }, "echo-server": { "help": "The URL string of the UDP/TCP echo server to use during testing; if this is not defined, no echo tests will be run", "value": "\"yourechoserver.com\"" }, "echo-udp-port": { "help": "The port to connect to on echo-server for UDP testing", "value": 7 }, "echo-tcp-port": { "help": "The port to connect to on echo-server for TCP testing", "value": 7 }, "ntp-server": { "help": "The URL string of the NTP server to use during testing", "value": "\"2.pool.ntp.org\"" }, "ntp-port": { "help": "The port to connect to on ntp-server", "value": 123 }, "local-port": { "help": "The local port to use when testing sock.bind()", "value": 16 }, "udp-max-packet-size": { "help": "The maximum UDP packet size to use when testing; 1024 bytes is the limit at the AT interface but 508 bytes is considered more reliable for the public internet", "value": 508 }, "tcp-max-packet-size": { "help": "The maximum TCP packet size to use when testing", "value": 1500 } }, "target_overrides": { "*": { "target.features_add": ["LWIP", "COMMON_PAL"], "platform.stdio-convert-newlines": true, "lwip.ipv4-enabled": true, "lwip.ipv6-enabled": false, "lwip.ethernet-enabled": false, "lwip.ppp-enabled": true, "lwip.tcp-enabled": true, "lwip.debug-enabled": false, "lwip.enable-ppp-trace": false, "lwip.use-mbed-trace": false, "mbed-trace.enable": 1 } } }