BLE FOTA APP

Dependencies:   BLE_API mbed

It doesn't work with the default FOTA bootloader. It use NVIC_SystemReset() to enter a bootloader.

Revision:
1:a607cd9655d7
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/nRF51822/nordic/nrf-sdk/ble/ble_services/ble_hts.h	Fri Oct 10 03:36:28 2014 +0000
@@ -0,0 +1,160 @@
+/* Copyright (c) 2012 Nordic Semiconductor. All Rights Reserved.
+ *
+ * The information contained herein is property of Nordic Semiconductor ASA.
+ * Terms and conditions of usage are described in detail in NORDIC
+ * SEMICONDUCTOR STANDARD SOFTWARE LICENSE AGREEMENT.
+ *
+ * Licensees are granted free, non-transferable use of the information. NO
+ * WARRANTY of ANY KIND is provided. This heading must NOT be removed from
+ * the file.
+ */
+
+/** @file
+ *
+ * @defgroup ble_sdk_srv_hts Health Thermometer Service
+ * @{
+ * @ingroup ble_sdk_srv
+ * @brief Health Thermometer Service module.
+ *
+ * @details This module implements the Health Thermometer Service.
+ *
+ *          If an event handler is supplied by the application, the Health Thermometer 
+ *          Service will generate Health Thermometer Service events to the application.
+ *
+ * @note The application must propagate BLE stack events to the Health Thermometer Service
+ *       module by calling ble_hts_on_ble_evt() from the from the @ref ble_stack_handler function.
+ *
+ * @note Attention! 
+ *  To maintain compliance with Nordic Semiconductor ASA Bluetooth profile 
+ *  qualification listings, this section of source code must not be modified.
+ */
+
+#ifndef BLE_HTS_H__
+#define BLE_HTS_H__
+
+#include <stdint.h>
+#include <stdbool.h>
+#include "ble.h"
+#include "ble_srv_common.h"
+#include "ble_date_time.h"
+
+// Temperature Type measurement locations
+#define BLE_HTS_TEMP_TYPE_ARMPIT      1
+#define BLE_HTS_TEMP_TYPE_BODY        2
+#define BLE_HTS_TEMP_TYPE_EAR         3
+#define BLE_HTS_TEMP_TYPE_FINGER      4
+#define BLE_HTS_TEMP_TYPE_GI_TRACT    5
+#define BLE_HTS_TEMP_TYPE_MOUTH       6
+#define BLE_HTS_TEMP_TYPE_RECTUM      7
+#define BLE_HTS_TEMP_TYPE_TOE         8
+#define BLE_HTS_TEMP_TYPE_EAR_DRUM    9
+
+/**@brief Health Thermometer Service event type. */
+typedef enum
+{
+    BLE_HTS_EVT_INDICATION_ENABLED,                                         /**< Health Thermometer value indication enabled event. */
+    BLE_HTS_EVT_INDICATION_DISABLED,                                        /**< Health Thermometer value indication disabled event. */
+    BLE_HTS_EVT_INDICATION_CONFIRMED                                        /**< Confirmation of a temperature measurement indication has been received. */
+} ble_hts_evt_type_t;
+
+/**@brief Health Thermometer Service event. */
+typedef struct
+{
+    ble_hts_evt_type_t evt_type;                                            /**< Type of event. */
+} ble_hts_evt_t;
+
+// Forward declaration of the ble_hts_t type. 
+typedef struct ble_hts_s ble_hts_t;
+
+/**@brief Health Thermometer Service event handler type. */
+typedef void (*ble_hts_evt_handler_t) (ble_hts_t * p_hts, ble_hts_evt_t * p_evt);
+
+/**@brief FLOAT format (IEEE-11073 32-bit FLOAT, defined as a 32-bit value with a 24-bit mantissa
+ *        and an 8-bit exponent. */
+typedef struct
+{
+  int8_t  exponent;                                                         /**< Base 10 exponent */
+  int32_t mantissa;                                                         /**< Mantissa, should be using only 24 bits */
+} ieee_float32_t;
+
+/**@brief Health Thermometer Service init structure. This contains all options and data
+ *        needed for initialization of the service. */
+typedef struct
+{
+    ble_hts_evt_handler_t        evt_handler;                               /**< Event handler to be called for handling events in the Health Thermometer Service. */
+    ble_srv_cccd_security_mode_t hts_meas_attr_md;                          /**< Initial security level for health thermometer measurement attribute */
+    ble_srv_security_mode_t      hts_temp_type_attr_md;                     /**< Initial security level for health thermometer tempearture type attribute */
+    uint8_t                      temp_type_as_characteristic;               /**< Set non-zero if temp type given as characteristic */
+    uint8_t                      temp_type;                                 /**< Temperature type if temperature characteristic is used */
+} ble_hts_init_t;
+
+/**@brief Health Thermometer Service structure. This contains various status information for
+ *        the service. */
+typedef struct ble_hts_s
+{
+    ble_hts_evt_handler_t        evt_handler;                               /**< Event handler to be called for handling events in the Health Thermometer Service. */
+    uint16_t                     service_handle;                            /**< Handle of Health Thermometer Service (as provided by the BLE stack). */
+    ble_gatts_char_handles_t     meas_handles;                              /**< Handles related to the Health Thermometer Measurement characteristic. */
+    ble_gatts_char_handles_t     temp_type_handles;                         /**< Handles related to the Health Thermometer Temperature Type characteristic. */
+    uint16_t                     conn_handle;                               /**< Handle of the current connection (as provided by the BLE stack, is BLE_CONN_HANDLE_INVALID if not in a connection). */
+    uint8_t                      temp_type;                                 /**< Temperature type indicates where the measurement was taken. */
+} ble_hts_t;
+
+/**@brief Health Thermometer Service measurement structure. This contains a Health Thermometer
+ *        measurement. */
+typedef struct ble_hts_meas_s
+{
+    bool                         temp_in_fahr_units;                        /**< True if Temperature is in Fahrenheit units, Celcius otherwise. */
+    bool                         time_stamp_present;                        /**< True if Time Stamp is present. */
+    bool                         temp_type_present;                         /**< True if Temperature Type is present. */
+    ieee_float32_t               temp_in_celcius;                           /**< Temperature Measurement Value (Celcius). */
+    ieee_float32_t               temp_in_fahr;                              /**< Temperature Measurement Value (Fahrenheit). */
+    ble_date_time_t              time_stamp;                                /**< Time Stamp. */
+    uint8_t                      temp_type;                                 /**< Temperature Type. */
+} ble_hts_meas_t;
+
+/**@brief Function for initializing the Health Thermometer Service.
+ *
+ * @param[out]  p_hts       Health Thermometer Service structure. This structure will have to
+ *                          be supplied by the application. It will be initialized by this function,
+ *                          and will later be used to identify this particular service instance.
+ * @param[in]   p_hts_init  Information needed to initialize the service.
+ *
+ * @return      NRF_SUCCESS on successful initialization of service, otherwise an error code.
+ */
+uint32_t ble_hts_init(ble_hts_t * p_hts, const ble_hts_init_t * p_hts_init);
+
+/**@brief Function for handling the Application's BLE Stack events.
+ *
+ * @details Handles all events from the BLE stack of interest to the Health Thermometer Service.
+ *
+ * @param[in]   p_hts      Health Thermometer Service structure.
+ * @param[in]   p_ble_evt  Event received from the BLE stack.
+ */
+void ble_hts_on_ble_evt(ble_hts_t * p_hts, ble_evt_t * p_ble_evt);
+
+/**@brief Function for sending health thermometer measurement if indication has been enabled.
+ *
+ * @details The application calls this function after having performed a Health Thermometer
+ *          measurement. If indication has been enabled, the measurement data is encoded and
+ *          sent to the client.
+ *
+ * @param[in]   p_hts       Health Thermometer Service structure.
+ * @param[in]   p_hts_meas  Pointer to new health thermometer measurement.
+ *
+ * @return      NRF_SUCCESS on success, otherwise an error code.
+ */
+uint32_t ble_hts_measurement_send(ble_hts_t * p_hts, ble_hts_meas_t * p_hts_meas);
+
+/**@brief Function for checking if indication of Temperature Measurement is currently enabled.
+ *
+ * @param[in]   p_hts                  Health Thermometer Service structure.
+ * @param[out]  p_indication_enabled   TRUE if indication is enabled, FALSE otherwise.
+ *
+ * @return      NRF_SUCCESS on success, otherwise an error code.
+ */
+uint32_t ble_hts_is_indication_enabled(ble_hts_t * p_hts, bool * p_indication_enabled);
+
+#endif // BLE_HTS_H__
+
+/** @} */