diff -r 000000000000 -r 2c1dce3543ae CCS811.h
--- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/CCS811.h Mon Sep 06 09:17:14 2021 +0000
@@ -0,0 +1,75 @@
+#ifndef CCS811_H
+#define CCS811_H
+
+//CCS811 register define
+#define CCS811_I2C_ADDR 0xB6 //This is already left shifted 0x5B, if using other address, should be 0xB4 which is 0x5A left shifted.
+#define CCS811_REG_STATUS 0x00 //Status.
+#define CCS811_REG_MEAS_MODE 0x01 //Mesurement mode and conditions register.
+#define CCS811_REG_ALG_RESULT_DATA 0x02 //Algorithm result. 2 bytes co2 ppm next 2 bytes ppb VOC level.
+#define CCS811_REG_RAW_DATA 0x03 //Raw ADC data.
+#define CCS811_REG_ENV_DATA 0x05 //Temperature and humidity data can be write to enavle compensation.
+#define CCS811_REG_NTC 0x06 //Provides the voltage across the reference registor and the voltage across the NTC resistor.
+#define CCS811_REG_THRESHOLDS 0x10 //Thresholds for operation when interrupts are only generated when eCO2 ppm crosses a threshold.
+#define CCS811_REG_BASELINE 0x11 //The encoded current baseline value can be read.A previously saved encoded baseline can be written.
+#define CCS811_REG_HW_ID 0x20 //Hardware ID. The value is 0x81.
+#define CCS811_REG_HW_VERSION 0x21 //Hardware version. The value is 0x1X.
+#define CCS811_REG_BOOT_VERSION 0x23 //Firmware boot version. The First 2 bytes contain the firmware version number for the boot code.
+#define CCS811_REG_APP_VERSION 0x24 //Firmware application version. The first 2 bytes contain the firmware version number for the application code.
+#define CCS811_REG_ERROR_ID 0xE0 //Error ID. When the status register reports and error its source is lcated in this register.
+#define CCS811_REG_APP_START 0xF4 //Application start. Used to transition the CCS811 state from boot to application mode, a write with no data is required. Before performing a write to APP_START the Status register should be accessed to check if there is a valid application present.
+#define CCS811_REG_SW_RESET 0xFF //If the correct 4 byres (0x11, 0xE5, 0x72, 0x8A)are written to this register in a single sequence the device will reset and return to BOOT bode.
+
+//mode setting
+#define CCS811_MEASUREMENT_MODE0 0x00 //Idle(Measurements are disabled in this mode).
+#define CCS811_MEASUREMENT_MODE1 0x10 //Constant power mode, IAQ measurement every second.
+#define CCS811_MEASUREMENT_MODE2 0x20 //Pulse heating mode IAQ measurement every 10 seconds.
+
+//CCS811 register define
+#define CCS811_I2C_ADDR 0xB6 //This is already left shifted 0x5B, if using other address, should be 0xB4 which is 0x5A left shifted.
+#define CCS811_REG_STATUS 0x00 //Status.
+#define CCS811_REG_MEAS_MODE 0x01 //Mesurement mode and conditions register.
+#define CCS811_REG_ALG_RESULT_DATA 0x02 //Algorithm result. 2 bytes co2 ppm next 2 bytes ppb VOC level.
+#define CCS811_REG_RAW_DATA 0x03 //Raw ADC data.
+#define CCS811_REG_ENV_DATA 0x05 //Temperature and humidity data can be write to enavle compensation.
+#define CCS811_REG_NTC 0x06 //Provides the voltage across the reference registor and the voltage across the NTC resistor.
+#define CCS811_REG_THRESHOLDS 0x10 //Thresholds for operation when interrupts are only generated when eCO2 ppm crosses a threshold.
+#define CCS811_REG_BASELINE 0x11 //The encoded current baseline value can be read.A previously saved encoded baseline can be written.
+#define CCS811_REG_HW_ID 0x20 //Hardware ID. The value is 0x81.
+#define CCS811_REG_HW_VERSION 0x21 //Hardware version. The value is 0x1X.
+#define CCS811_REG_BOOT_VERSION 0x23 //Firmware boot version. The First 2 bytes contain the firmware version number for the boot code.
+#define CCS811_REG_APP_VERSION 0x24 //Firmware application version. The first 2 bytes contain the firmware version number for the application code.
+#define CCS811_REG_ERROR_ID 0xE0 //Error ID. When the status register reports and error its source is lcated in this register.
+#define CCS811_REG_APP_START 0xF4 //Application start. Used to transition the CCS811 state from boot to application mode, a write with no data is required. Before performing a write to APP_START the Status register should be accessed to check if there is a valid application present.
+#define CCS811_REG_SW_RESET 0xFF //If the correct 4 byres (0x11, 0xE5, 0x72, 0x8A)are written to this register in a single sequence the device will reset and return to BOOT bode.
+
+//mode setting
+#define CCS811_MEASUREMENT_MODE0 0x00 //Idle(Measurements are disabled in this mode).
+#define CCS811_MEASUREMENT_MODE1 0x10 //Constant power mode, IAQ measurement every second.
+#define CCS811_MEASUREMENT_MODE2 0x20 //Pulse heating mode IAQ measurement every 10 seconds.
+#define CCS811_MEASUREMENT_MODE3 0x30 //Low power pulse heating mode IAQ measurement every 60 seconds.
+#define CCS811_MEASUREMENT_MODE4 0x40 //Constant power mode, sensor measurement every 250ms. 1xx: Reserved modes (For future use).
+
+//Interrupt control
+#define CCS811_INT_DATARDY 0x08 //At the end of each measurement cycle (250ms, 1s, 10s, 60s) a flag is set in the STATUS register regardless of the setting of this bit.
+#define CCS811_INT_THRESH 0x04 //0: Interrupt mode (if enabled) operates normally 1: Interrupt mode (if enabled) only asserts the nINT signal (driven low) if the new ALG_RESULT_DATA crosses one of the thresholds set in the THRESHOLDS register by more than the hysteresis value (also in the THRESHOLDS register).
+
+#include "mbed.h"
+
+class CCS811 {
+ public:
+ CCS811(PinName sda, PinName scl); // Créer une instance CCS811 connectée aux pin I2C sda et scl
+ void init(); // Initialisation capteur CCS811
+ int setMeasureMode(char mode);
+ int readData(uint16_t *ECO2, uint16_t *TVOC);
+ bool checkHW();
+ bool softRest();
+ bool readstatus();
+ bool readmeas();
+ bool readerror();
+ protected:
+ I2C _i2c;
+ private:
+};
+
+
+ #endif