Jens Schmidt / MicrobitIAQ

Dependencies:   microbit

Changes

RevisionDateWhoCommit message
60:6b21ca38ee7c 2022-06-03 jsa1969 cleanup default tip
59:1ca41f08b6a4 2022-06-03 jsa1969 send less data to partner microbit
58:4f6061b6f65a 2022-06-03 jsa1969 fix overflow issue in radio
57:1687d6e37410 2022-03-09 jsa1969 more output
56:6a7142c84db5 2022-01-21 jsa1969 allow setting SGP30 baselins directly by sending a micro:bit radio command
55:f135f5e73273 2022-01-20 jsa1969 fix non volatile storage test
54:7a73502d5308 2022-01-20 jsa1969 some more tests
53:d560c097f1b4 2022-01-20 jsa1969 fix storage of SGP30 baseline
52:112eaa5282c6 2022-01-20 jsa1969 transmit more information
51:133f2fb8a7c5 2022-01-17 jsa1969 more delays when sending, had problems when distance was large
50:63442fd5e709 2022-01-17 jsa1969 fixed possible buffer overflow in radio module and wrong replies in base line set
49:bbb506b58e6e 2022-01-16 jsa1969 support switching light levels via btn B
48:52cad865a84f 2019-03-21 jsa1969 code cleanup (removed comments)
47:881bfe77a00a 2019-02-17 jsa1969 show bme680 gas res linear, not exponential
46:2fed2865a0f3 2019-02-15 jsa1969 finally up and running again, next steps: split nvstore into general and app specific functions, split ui from main, more tests
45:d6a9fd9c8200 2019-02-13 jsa1969 more unit tests
44:67a19da5f269 2019-02-13 jsa1969 more bme tweaking
43:f968ca84d4ed 2019-02-13 jsa1969 seems the stray values resulting from delay problems have finally been solved
42:ce269f988ac8 2019-02-13 jsa1969 apparently when working both chips parallel we do not have an i2c issue (buses had been separated) but a delay issue with bme680 -> first attempt to fix that
41:8f891ea56b0d 2019-02-13 jsa1969 cleanup 2nd i2c Bus if not required
40:a67a880cb538 2019-02-13 jsa1969 for the moment: seperate the i2c busses of the chips and remove all locking
39:efe22f143e47 2019-02-13 jsa1969 moved debugging information
38:0f29a0ea64ca 2019-02-12 jsa1969 attempt to attack on the parrallel influence problem
37:9e15c0120f76 2019-02-12 jsa1969 fixup reasonable average logic
36:ea1d6572314e 2019-02-12 jsa1969 only use reasonable range checks on bme gas resistance for max value
35:5f9566f22a2a 2019-02-12 jsa1969 bugfix a return statement, next I need tests for nvstore
34:069c4f6d5b2c 2019-02-12 jsa1969 code cleanup
33:af2dfab24ca9 2019-02-12 jsa1969 tests and usage of moving average for bme gas resistence
32:2c923405660c 2019-02-03 jsa1969 use english terms for and in MovingAverage
31:3284adaf4804 2019-02-02 jsa1969 implements math function: gleitender Durchschnitt
30:2958c6c803b9 2018-12-15 jsa1969 do not store SGP30 min values in microbit.storage, because they are always 0/400
29:7b5a600b24d6 2018-12-15 jsa1969 comment on the number of values we store in microbit.storage
28:56273b8282ca 2018-12-14 jsa1969 no point displaying sgp300 min values, they are always 0/400
27:cb75a0c5c52a 2018-12-14 jsa1969 store bme680 gas resistance indexed by humidity
26:6138698d4e6b 2018-12-06 jsa1969 more sensitive reaction to measurement differences
25:ab53abf41a9e 2018-12-05 jsa1969 update readme
24:07a1d2e6914e 2018-12-05 jsa1969 release fibers when loops have finished
23:051e0add6516 2018-12-05 jsa1969 inserted readme
22:5a8bec9862db 2018-12-05 jsa1969 updated comments
21:01914186ee1d 2018-12-05 jsa1969 added license files for 3rd party open source libs
20:2f11b93f4cbf 2018-12-05 jsa1969 use btn B to change display state (bright, low, off)
19:52e19461e867 2018-12-05 jsa1969 fix data log wipe
18:c4ac93e01027 2018-12-05 jsa1969 data logging for sgp30
17:a2c4dd192146 2018-12-05 jsa1969 more logging
16:3a4b9a3ef2bb 2018-12-05 jsa1969 mention GitHub sources for bme680 and sgp30 code
15:8bb5c580d453 2018-12-05 jsa1969 more const nes
14:71060505061e 2018-12-05 jsa1969 more flexible nvstore
13:996026828be7 2018-12-05 jsa1969 update status of sgp onmeasurements
12:96eb06e837f4 2018-12-05 jsa1969 independent fibres/loops for bme and agp measuring
11:6844a5578b4f 2018-12-04 jsa1969 code cleanup / smaller functions
10:8e6b71a46871 2018-12-04 jsa1969 store bme680 max gas resistence
9:5150afa50eb6 2018-12-04 jsa1969 re-init sensors on btn AB
8:1bdb50e03d39 2018-12-04 jsa1969 display more data on btn B
7:80429cbd095f 2018-12-04 jsa1969 properly schedule measure loop at start
6:fc6f2f08724b 2018-12-04 jsa1969 fixup sgp30 self test
5:9a04d6d0c2ff 2018-12-04 jsa1969 cleanup UI (less text, more dots)
4:aef0bddcdf50 2018-12-04 jsa1969 less display.scroll / more information in dots
3:6084ab9ff0c9 2018-12-04 jsa1969 handle cases where only one sensor is present
2:544117df8c65 2018-12-04 jsa1969 sgp30
1:f9245fb53737 2018-12-03 jsa1969 add humidity physics