@@ -0,0 +1,273 @@
+/******************************************************************************
+ * Copyright (c) 2019, STMicroelectronics - All Rights Reserved
+
+ This file is part of VL53LX Core and is dual licensed,
+ either 'STMicroelectronics Proprietary license'
+ or 'BSD 3-clause "New" or "Revised" License' , at your option.
+
+ ******************************************************************************
+
+ 'STMicroelectronics Proprietary license'
+
+ *******************************************************************************
+
+ License terms: STMicroelectronics Proprietary in accordance with licensing
+ terms at www.st.com/sla0081
+
+ STMicroelectronics confidential
+ Reproduction and Communication of this document is strictly prohibited unless
+ specifically authorized in writing by STMicroelectronics.
+
+
+ *******************************************************************************
+
+ Alternatively, VL53LX Core may be distributed under the terms of
+ 'BSD 3-clause "New" or "Revised" License', in which case the following
+ provisions apply instead of the ones mentioned above :
+
+ *******************************************************************************
+
+ License terms: BSD 3-clause "New" or "Revised" License.
+
+ Redistribution and use in source and binary forms, with or without
+ modification, are permitted provided that the following conditions are met:
+
+ 1. Redistributions of source code must retain the above copyright notice, this
+ list of conditions and the following disclaimer.
+
+ 2. Redistributions in binary form must reproduce the above copyright notice,
+ this list of conditions and the following disclaimer in the documentation
+ and/or other materials provided with the distribution.
+
+ 3. Neither the name of the copyright holder nor the names of its contributors
+ may be used to endorse or promote products derived from this software
+ without specific prior written permission.
+
+ THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
+ AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
+ IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
+ DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE
+ FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
+ DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
+ SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
+ CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
+ OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
+ OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+
+
+ *******************************************************************************
+ */
+
+/**
+ * @file vl53lx_error_codes.h
+ *
+ * @brief Error Code definitions for VL53LX API.
+ *
+ */
+
+#ifndef _VL53LX_ERROR_CODES_H_
+#define _VL53LX_ERROR_CODES_H_
+
+#include "vl53lx_types.h"
+
+#ifdef __cplusplus
+extern "C" {
+#endif
+
+
+/*
+ ****************************************
+ * PRIVATE define do not edit
+ ***************************************
+ */
+
+/*
+ * @defgroup VL53LX_define_Error_group Error and Warning code returned by API
+ * The following DEFINE are used to identify the PAL ERROR
+ * @{
+ */
+
+typedef int8_t VL53LX_Error;
+
+#define VL53LX_ERROR_NONE ((VL53LX_Error) 0)
+#define VL53LX_ERROR_CALIBRATION_WARNING ((VL53LX_Error) - 1)
+ /*!< Warning invalid calibration data may be in used
+ * \a VL53LX_InitData()
+ * \a VL53LX_GetOffsetCalibrationData
+ * \a VL53LX_SetOffsetCalibrationData
+ */
+#define VL53LX_ERROR_MIN_CLIPPED ((VL53LX_Error) - 2)
+ /*!< Warning parameter passed was clipped to min before to be applied */
+
+#define VL53LX_ERROR_UNDEFINED ((VL53LX_Error) - 3)
+ /*!< Unqualified error */
+#define VL53LX_ERROR_INVALID_PARAMS ((VL53LX_Error) - 4)
+ /*!< Parameter passed is invalid or out of range */
+#define VL53LX_ERROR_NOT_SUPPORTED ((VL53LX_Error) - 5)
+ /*!< Function is not supported in current mode or configuration */
+#define VL53LX_ERROR_RANGE_ERROR ((VL53LX_Error) - 6)
+ /*!< Device report a ranging error interrupt status */
+#define VL53LX_ERROR_TIME_OUT ((VL53LX_Error) - 7)
+ /*!< Aborted due to time out */
+#define VL53LX_ERROR_MODE_NOT_SUPPORTED ((VL53LX_Error) - 8)
+ /*!< Asked mode is not supported by the device */
+#define VL53LX_ERROR_BUFFER_TOO_SMALL ((VL53LX_Error) - 9)
+ /*!< ... */
+#define VL53LX_ERROR_COMMS_BUFFER_TOO_SMALL ((VL53LX_Error) - 10)
+ /*!< Supplied buffer is larger than I2C supports */
+#define VL53LX_ERROR_GPIO_NOT_EXISTING ((VL53LX_Error) - 11)
+ /*!< User tried to setup a non-existing GPIO pin */
+#define VL53LX_ERROR_GPIO_FUNCTIONALITY_NOT_SUPPORTED ((VL53LX_Error) - 12)
+ /*!< unsupported GPIO functionality */
+#define VL53LX_ERROR_CONTROL_INTERFACE ((VL53LX_Error) - 13)
+ /*!< error reported from IO functions */
+#define VL53LX_ERROR_INVALID_COMMAND ((VL53LX_Error) - 14)
+ /*!< The command is not allowed in the current device state
+ * (power down)
+ */
+#define VL53LX_ERROR_DIVISION_BY_ZERO ((VL53LX_Error) - 15)
+ /*!< In the function a division by zero occurs */
+#define VL53LX_ERROR_REF_SPAD_INIT ((VL53LX_Error) - 16)
+ /*!< Error during reference SPAD initialization */
+#define VL53LX_ERROR_GPH_SYNC_CHECK_FAIL ((VL53LX_Error) - 17)
+ /*!< GPH sync interrupt check fail - API out of sync with device*/
+#define VL53LX_ERROR_STREAM_COUNT_CHECK_FAIL ((VL53LX_Error) - 18)
+ /*!< Stream count check fail - API out of sync with device */
+#define VL53LX_ERROR_GPH_ID_CHECK_FAIL ((VL53LX_Error) - 19)
+ /*!< GPH ID check fail - API out of sync with device */
+#define VL53LX_ERROR_ZONE_STREAM_COUNT_CHECK_FAIL ((VL53LX_Error) - 20)
+ /*!< Zone dynamic config stream count check failed - API out of sync */
+#define VL53LX_ERROR_ZONE_GPH_ID_CHECK_FAIL ((VL53LX_Error) - 21)
+ /*!< Zone dynamic config GPH ID check failed - API out of sync */
+
+#define VL53LX_ERROR_XTALK_EXTRACTION_NO_SAMPLE_FAIL ((VL53LX_Error) - 22)
+ /*!< Thrown when run_xtalk_extraction fn has 0 succesful samples
+ * when using the full array to sample the xtalk. In this case there is
+ * not enough information to generate new Xtalk parm info. The function
+ * will exit and leave the current xtalk parameters unaltered
+ */
+#define VL53LX_ERROR_XTALK_EXTRACTION_SIGMA_LIMIT_FAIL ((VL53LX_Error) - 23)
+ /*!< Thrown when run_xtalk_extraction fn has found that the
+ * avg sigma estimate of the full array xtalk sample is > than the
+ * maximal limit allowed. In this case the xtalk sample is too noisy for
+ * measurement. The function will exit and leave the current xtalk
+ * parameters unaltered.
+ */
+
+
+#define VL53LX_ERROR_OFFSET_CAL_NO_SAMPLE_FAIL ((VL53LX_Error) - 24)
+ /*!< Thrown if there one of stages has no valid offset calibration
+ * samples. A fatal error calibration not valid
+ */
+#define VL53LX_ERROR_OFFSET_CAL_NO_SPADS_ENABLED_FAIL ((VL53LX_Error) - 25)
+ /*!< Thrown if there one of stages has zero effective SPADS
+ * Traps the case when MM1 SPADs is zero.
+ * A fatal error calibration not valid
+ */
+#define VL53LX_ERROR_ZONE_CAL_NO_SAMPLE_FAIL ((VL53LX_Error) - 26)
+ /*!< Thrown if then some of the zones have no valid samples
+ * A fatal error calibration not valid
+ */
+
+#define VL53LX_ERROR_TUNING_PARM_KEY_MISMATCH ((VL53LX_Error) - 27)
+ /*!< Thrown if the tuning file key table version does not match with
+ * expected value. The driver expects the key table version to match
+ * the compiled default version number in the define
+ * #VL53LX_TUNINGPARM_KEY_TABLE_VERSION_DEFAULT
+ */
+
+#define VL53LX_WARNING_REF_SPAD_CHAR_NOT_ENOUGH_SPADS ((VL53LX_Error) - 28)
+ /*!< Thrown if there are less than 5 good SPADs are available. */
+#define VL53LX_WARNING_REF_SPAD_CHAR_RATE_TOO_HIGH ((VL53LX_Error) - 29)
+ /*!< Thrown if the final reference rate is greater than
+ * the upper reference rate limit - default is 40 Mcps.
+ * Implies a minimum Q3 (x10) SPAD (5) selected
+ */
+#define VL53LX_WARNING_REF_SPAD_CHAR_RATE_TOO_LOW ((VL53LX_Error) - 30)
+ /*!< Thrown if the final reference rate is less than
+ * the lower reference rate limit - default is 10 Mcps.
+ * Implies maximum Q1 (x1) SPADs selected
+ */
+
+
+#define VL53LX_WARNING_OFFSET_CAL_MISSING_SAMPLES ((VL53LX_Error) - 31)
+ /*!< Thrown if there is less than the requested number of
+ * valid samples.
+ */
+#define VL53LX_WARNING_OFFSET_CAL_SIGMA_TOO_HIGH ((VL53LX_Error) - 32)
+ /*!< Thrown if the offset calibration range sigma estimate is greater
+ * than 8.0 mm. This is the recommended min value to yield a stable
+ * offset measurement
+ */
+#define VL53LX_WARNING_OFFSET_CAL_RATE_TOO_HIGH ((VL53LX_Error) - 33)
+ /*!< Thrown when VL53LX_run_offset_calibration() peak rate is greater
+ * than that 50.0Mcps. This is the recommended max rate to avoid
+ * pile-up influencing the offset measurement
+ */
+#define VL53LX_WARNING_OFFSET_CAL_SPAD_COUNT_TOO_LOW ((VL53LX_Error) - 34)
+ /*!< Thrown when VL53LX_run_offset_calibration() when one of stages
+ * range has less that 5.0 effective SPADS. This is the recommended
+ * min value to yield a stable offset
+ */
+
+
+#define VL53LX_WARNING_ZONE_CAL_MISSING_SAMPLES ((VL53LX_Error) - 35)
+ /*!< Thrown if one of more of the zones have less than
+ * the requested number of valid samples
+ */
+#define VL53LX_WARNING_ZONE_CAL_SIGMA_TOO_HIGH ((VL53LX_Error) - 36)
+ /*!< Thrown if one or more zones have sigma estimate value greater
+ * than 8.0 mm. This is the recommended min value to yield a stable
+ * offset measurement
+ */
+#define VL53LX_WARNING_ZONE_CAL_RATE_TOO_HIGH ((VL53LX_Error) - 37)
+ /*!< Thrown if one of more zones have peak rate higher than
+ * that 50.0Mcps. This is the recommended max rate to avoid
+ * pile-up influencing the offset measurement
+ */
+
+
+#define VL53LX_WARNING_XTALK_MISSING_SAMPLES ((VL53LX_Error) - 38)
+ /*!< Thrown to notify that some of the xtalk samples did not yield
+ * valid ranging pulse data while attempting to measure
+ * the xtalk signal in vl53lx_run_xtalk_extract(). This can signify any
+ * of the zones are missing samples, for further debug information the
+ * xtalk_results struct should be referred to. This warning is for
+ * notification only, xtalk pulse and shape have still been generated
+ */
+#define VL53LX_WARNING_XTALK_NO_SAMPLES_FOR_GRADIENT ((VL53LX_Error) - 39)
+ /*!< Thrown to notify that some of teh xtalk samples used for gradient
+ * generation did not yield valid ranging pulse data while attempting to
+ * measure the xtalk signal in vl53lx_run_xtalk_extract(). This can
+ * signify that any one of the zones 0-3 yielded no successful samples.
+ * xtalk_results struct should be referred to for further debug info.
+ * This warning is for notification only, the xtalk pulse and shape
+ * have still been generated.
+ */
+#define VL53LX_WARNING_XTALK_SIGMA_LIMIT_FOR_GRADIENT ((VL53LX_Error) - 40)
+ /*!< Thrown to notify that some of the xtalk samples used for gradient
+ * generation did not pass the sigma limit check while attempting to
+ * measure the xtalk signal in vl53lx_run_xtalk_extract(). This can
+ * signify that any one of the zones 0-3 yielded an avg sigma_mm
+ * value > the limit. The xtalk_results struct should be referred to for
+ * further debug info.
+ * This warning is for notification only, the xtalk pulse and shape
+ * have still been generated.
+ */
+
+#define VL53LX_ERROR_NOT_IMPLEMENTED ((VL53LX_Error) - 41)
+ /*!< Tells requested functionality has not been implemented yet or
+ * not compatible with the device
+ */
+#define VL53LX_ERROR_PLATFORM_SPECIFIC_START ((VL53LX_Error) - 60)
+ /*!< Tells the starting code for platform */
+/** @} VL53LX_define_Error_group */
+
+
+#ifdef __cplusplus
+}
+#endif
+
+