Jeon byungchul
/
aws-iot-example
this is fork and i will modify for STM32
Fork of AWS-test by
aws-iot/src/aws_iot_mqtt_client_subscribe.cpp@2:db59f45ad3d3, 2017-08-04 (annotated)
- Committer:
- bcjun@aname.co.kr
- Date:
- Fri Aug 04 14:06:06 2017 +0900
- Revision:
- 2:db59f45ad3d3
- Parent:
- 0:cd5404401c2f
'SUCCESS' is already defined at stm32 hal.
so changed 'IOT_SUCCESS'
Who changed what in which revision?
User | Revision | Line number | New contents of line |
---|---|---|---|
peyo |
0:cd5404401c2f | 1 | /* |
peyo |
0:cd5404401c2f | 2 | * Copyright 2015-2016 Amazon.com, Inc. or its affiliates. All Rights Reserved. |
peyo |
0:cd5404401c2f | 3 | * |
peyo |
0:cd5404401c2f | 4 | * Licensed under the Apache License, Version 2.0 (the "License"). |
peyo |
0:cd5404401c2f | 5 | * You may not use this file except in compliance with the License. |
peyo |
0:cd5404401c2f | 6 | * A copy of the License is located at |
peyo |
0:cd5404401c2f | 7 | * |
peyo |
0:cd5404401c2f | 8 | * http://aws.amazon.com/apache2.0 |
peyo |
0:cd5404401c2f | 9 | * |
peyo |
0:cd5404401c2f | 10 | * or in the "license" file accompanying this file. This file is distributed |
peyo |
0:cd5404401c2f | 11 | * on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either |
peyo |
0:cd5404401c2f | 12 | * express or implied. See the License for the specific language governing |
peyo |
0:cd5404401c2f | 13 | * permissions and limitations under the License. |
peyo |
0:cd5404401c2f | 14 | */ |
peyo |
0:cd5404401c2f | 15 | |
peyo |
0:cd5404401c2f | 16 | // Based on Eclipse Paho. |
peyo |
0:cd5404401c2f | 17 | /******************************************************************************* |
peyo |
0:cd5404401c2f | 18 | * Copyright (c) 2014 IBM Corp. |
peyo |
0:cd5404401c2f | 19 | * |
peyo |
0:cd5404401c2f | 20 | * All rights reserved. This program and the accompanying materials |
peyo |
0:cd5404401c2f | 21 | * are made available under the terms of the Eclipse Public License v1.0 |
peyo |
0:cd5404401c2f | 22 | * and Eclipse Distribution License v1.0 which accompany this distribution. |
peyo |
0:cd5404401c2f | 23 | * |
peyo |
0:cd5404401c2f | 24 | * The Eclipse Public License is available at |
peyo |
0:cd5404401c2f | 25 | * http://www.eclipse.org/legal/epl-v10.html |
peyo |
0:cd5404401c2f | 26 | * and the Eclipse Distribution License is available at |
peyo |
0:cd5404401c2f | 27 | * http://www.eclipse.org/org/documents/edl-v10.php. |
peyo |
0:cd5404401c2f | 28 | * |
peyo |
0:cd5404401c2f | 29 | * Contributors: |
peyo |
0:cd5404401c2f | 30 | * Ian Craggs - initial API and implementation and/or initial documentation |
peyo |
0:cd5404401c2f | 31 | *******************************************************************************/ |
peyo |
0:cd5404401c2f | 32 | |
peyo |
0:cd5404401c2f | 33 | /** |
peyo |
0:cd5404401c2f | 34 | * @file aws_iot_mqtt_client_subscribe.c |
peyo |
0:cd5404401c2f | 35 | * @brief MQTT client subscribe API definitions |
peyo |
0:cd5404401c2f | 36 | */ |
peyo |
0:cd5404401c2f | 37 | |
peyo |
0:cd5404401c2f | 38 | #ifdef __cplusplus |
peyo |
0:cd5404401c2f | 39 | extern "C" { |
peyo |
0:cd5404401c2f | 40 | #endif |
peyo |
0:cd5404401c2f | 41 | |
peyo |
0:cd5404401c2f | 42 | #include "aws_iot_mqtt_client_common_internal.h" |
peyo |
0:cd5404401c2f | 43 | |
peyo |
0:cd5404401c2f | 44 | /** |
peyo |
0:cd5404401c2f | 45 | * Serializes the supplied subscribe data into the supplied buffer, ready for sending |
peyo |
0:cd5404401c2f | 46 | * @param pTxBuf the buffer into which the packet will be serialized |
peyo |
0:cd5404401c2f | 47 | * @param txBufLen the length in bytes of the supplied buffer |
peyo |
0:cd5404401c2f | 48 | * @param dup unsigned char - the MQTT dup flag |
peyo |
0:cd5404401c2f | 49 | * @param packetId uint16_t - the MQTT packet identifier |
peyo |
0:cd5404401c2f | 50 | * @param topicCount - number of members in the topicFilters and reqQos arrays |
peyo |
0:cd5404401c2f | 51 | * @param pTopicNameList - array of topic filter names |
peyo |
0:cd5404401c2f | 52 | * @param pTopicNameLenList - array of length of topic filter names |
peyo |
0:cd5404401c2f | 53 | * @param pRequestedQoSs - array of requested QoS |
peyo |
0:cd5404401c2f | 54 | * @param pSerializedLen - the length of the serialized data |
peyo |
0:cd5404401c2f | 55 | * |
peyo |
0:cd5404401c2f | 56 | * @return An IoT Error Type defining successful/failed operation |
peyo |
0:cd5404401c2f | 57 | */ |
peyo |
0:cd5404401c2f | 58 | static IoT_Error_t _aws_iot_mqtt_serialize_subscribe(unsigned char *pTxBuf, size_t txBufLen, |
peyo |
0:cd5404401c2f | 59 | unsigned char dup, uint16_t packetId, uint32_t topicCount, |
peyo |
0:cd5404401c2f | 60 | const char **pTopicNameList, uint16_t *pTopicNameLenList, |
peyo |
0:cd5404401c2f | 61 | QoS *pRequestedQoSs, uint32_t *pSerializedLen) { |
peyo |
0:cd5404401c2f | 62 | unsigned char *ptr; |
peyo |
0:cd5404401c2f | 63 | uint32_t itr, rem_len; |
peyo |
0:cd5404401c2f | 64 | IoT_Error_t rc; |
peyo |
0:cd5404401c2f | 65 | MQTTHeader header = {0}; |
peyo |
0:cd5404401c2f | 66 | |
peyo |
0:cd5404401c2f | 67 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 68 | if(NULL == pTxBuf || NULL == pSerializedLen) { |
peyo |
0:cd5404401c2f | 69 | FUNC_EXIT_RC(NULL_VALUE_ERROR); |
peyo |
0:cd5404401c2f | 70 | } |
peyo |
0:cd5404401c2f | 71 | |
peyo |
0:cd5404401c2f | 72 | ptr = pTxBuf; |
peyo |
0:cd5404401c2f | 73 | rem_len = 2; /* packetId */ |
peyo |
0:cd5404401c2f | 74 | |
peyo |
0:cd5404401c2f | 75 | for(itr = 0; itr < topicCount; ++itr) { |
peyo |
0:cd5404401c2f | 76 | rem_len += (uint32_t) (pTopicNameLenList[itr] + 2 + 1); /* topic + length + req_qos */ |
peyo |
0:cd5404401c2f | 77 | } |
peyo |
0:cd5404401c2f | 78 | |
peyo |
0:cd5404401c2f | 79 | if(aws_iot_mqtt_internal_get_final_packet_length_from_remaining_length(rem_len) > txBufLen) { |
peyo |
0:cd5404401c2f | 80 | FUNC_EXIT_RC(MQTT_TX_BUFFER_TOO_SHORT_ERROR); |
peyo |
0:cd5404401c2f | 81 | } |
peyo |
0:cd5404401c2f | 82 | |
peyo |
0:cd5404401c2f | 83 | rc = aws_iot_mqtt_internal_init_header(&header, SUBSCRIBE, QOS1, dup, 0); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 84 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 85 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 86 | } |
peyo |
0:cd5404401c2f | 87 | /* write header */ |
peyo |
0:cd5404401c2f | 88 | aws_iot_mqtt_internal_write_char(&ptr, header.byte); |
peyo |
0:cd5404401c2f | 89 | |
peyo |
0:cd5404401c2f | 90 | /* write remaining length */ |
peyo |
0:cd5404401c2f | 91 | ptr += aws_iot_mqtt_internal_write_len_to_buffer(ptr, rem_len); |
peyo |
0:cd5404401c2f | 92 | |
peyo |
0:cd5404401c2f | 93 | aws_iot_mqtt_internal_write_uint_16(&ptr, packetId); |
peyo |
0:cd5404401c2f | 94 | |
peyo |
0:cd5404401c2f | 95 | for(itr = 0; itr < topicCount; ++itr) { |
peyo |
0:cd5404401c2f | 96 | aws_iot_mqtt_internal_write_utf8_string(&ptr, pTopicNameList[itr], pTopicNameLenList[itr]); |
peyo |
0:cd5404401c2f | 97 | aws_iot_mqtt_internal_write_char(&ptr, (unsigned char) pRequestedQoSs[itr]); |
peyo |
0:cd5404401c2f | 98 | } |
peyo |
0:cd5404401c2f | 99 | |
peyo |
0:cd5404401c2f | 100 | *pSerializedLen = (uint32_t) (ptr - pTxBuf); |
peyo |
0:cd5404401c2f | 101 | |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 102 | FUNC_EXIT_RC(IOT_SUCCESS); |
peyo |
0:cd5404401c2f | 103 | } |
peyo |
0:cd5404401c2f | 104 | |
peyo |
0:cd5404401c2f | 105 | /** |
peyo |
0:cd5404401c2f | 106 | * Deserializes the supplied (wire) buffer into suback data |
peyo |
0:cd5404401c2f | 107 | * @param pPacketId returned integer - the MQTT packet identifier |
peyo |
0:cd5404401c2f | 108 | * @param maxExpectedQoSCount - the maximum number of members allowed in the grantedQoSs array |
peyo |
0:cd5404401c2f | 109 | * @param pGrantedQoSCount returned uint32_t - number of members in the grantedQoSs array |
peyo |
0:cd5404401c2f | 110 | * @param pGrantedQoSs returned array of QoS type - the granted qualities of service |
peyo |
0:cd5404401c2f | 111 | * @param pRxBuf the raw buffer data, of the correct length determined by the remaining length field |
peyo |
0:cd5404401c2f | 112 | * @param rxBufLen the length in bytes of the data in the supplied buffer |
peyo |
0:cd5404401c2f | 113 | * |
peyo |
0:cd5404401c2f | 114 | * @return An IoT Error Type defining successful/failed operation |
peyo |
0:cd5404401c2f | 115 | */ |
peyo |
0:cd5404401c2f | 116 | static IoT_Error_t _aws_iot_mqtt_deserialize_suback(uint16_t *pPacketId, uint32_t maxExpectedQoSCount, |
peyo |
0:cd5404401c2f | 117 | uint32_t *pGrantedQoSCount, QoS *pGrantedQoSs, |
peyo |
0:cd5404401c2f | 118 | unsigned char *pRxBuf, size_t rxBufLen) { |
peyo |
0:cd5404401c2f | 119 | unsigned char *curData, *endData; |
peyo |
0:cd5404401c2f | 120 | uint32_t decodedLen, readBytesLen; |
peyo |
0:cd5404401c2f | 121 | IoT_Error_t decodeRc; |
peyo |
0:cd5404401c2f | 122 | MQTTHeader header = {0}; |
peyo |
0:cd5404401c2f | 123 | |
peyo |
0:cd5404401c2f | 124 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 125 | if(NULL == pPacketId || NULL == pGrantedQoSCount || NULL == pGrantedQoSs) { |
peyo |
0:cd5404401c2f | 126 | FUNC_EXIT_RC(NULL_VALUE_ERROR); |
peyo |
0:cd5404401c2f | 127 | } |
peyo |
0:cd5404401c2f | 128 | |
peyo |
0:cd5404401c2f | 129 | curData = pRxBuf; |
peyo |
0:cd5404401c2f | 130 | endData = NULL; |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 131 | decodeRc = IOT_FAILURE; |
peyo |
0:cd5404401c2f | 132 | decodedLen = 0; |
peyo |
0:cd5404401c2f | 133 | readBytesLen = 0; |
peyo |
0:cd5404401c2f | 134 | |
peyo |
0:cd5404401c2f | 135 | /* SUBACK header size is 4 bytes for header and at least one byte for QoS payload |
peyo |
0:cd5404401c2f | 136 | * Need at least a 5 bytes buffer. MQTT3.1.1 specification 3.9 |
peyo |
0:cd5404401c2f | 137 | */ |
peyo |
0:cd5404401c2f | 138 | if(5 > rxBufLen) { |
peyo |
0:cd5404401c2f | 139 | FUNC_EXIT_RC(MQTT_RX_BUFFER_TOO_SHORT_ERROR); |
peyo |
0:cd5404401c2f | 140 | } |
peyo |
0:cd5404401c2f | 141 | |
peyo |
0:cd5404401c2f | 142 | header.byte = aws_iot_mqtt_internal_read_char(&curData); |
peyo |
0:cd5404401c2f | 143 | if(SUBACK != header.bits.type) { |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 144 | FUNC_EXIT_RC(IOT_FAILURE); |
peyo |
0:cd5404401c2f | 145 | } |
peyo |
0:cd5404401c2f | 146 | |
peyo |
0:cd5404401c2f | 147 | /* read remaining length */ |
peyo |
0:cd5404401c2f | 148 | decodeRc = aws_iot_mqtt_internal_decode_remaining_length_from_buffer(curData, &decodedLen, &readBytesLen); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 149 | if(IOT_SUCCESS != decodeRc) { |
peyo |
0:cd5404401c2f | 150 | FUNC_EXIT_RC(decodeRc); |
peyo |
0:cd5404401c2f | 151 | } |
peyo |
0:cd5404401c2f | 152 | |
peyo |
0:cd5404401c2f | 153 | curData += (readBytesLen); |
peyo |
0:cd5404401c2f | 154 | endData = curData + decodedLen; |
peyo |
0:cd5404401c2f | 155 | if(endData - curData < 2) { |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 156 | FUNC_EXIT_RC(IOT_FAILURE); |
peyo |
0:cd5404401c2f | 157 | } |
peyo |
0:cd5404401c2f | 158 | |
peyo |
0:cd5404401c2f | 159 | *pPacketId = aws_iot_mqtt_internal_read_uint16_t(&curData); |
peyo |
0:cd5404401c2f | 160 | |
peyo |
0:cd5404401c2f | 161 | *pGrantedQoSCount = 0; |
peyo |
0:cd5404401c2f | 162 | while(curData < endData) { |
peyo |
0:cd5404401c2f | 163 | if(*pGrantedQoSCount > maxExpectedQoSCount) { |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 164 | FUNC_EXIT_RC(IOT_FAILURE); |
peyo |
0:cd5404401c2f | 165 | } |
peyo |
0:cd5404401c2f | 166 | pGrantedQoSs[(*pGrantedQoSCount)++] = (QoS) aws_iot_mqtt_internal_read_char(&curData); |
peyo |
0:cd5404401c2f | 167 | } |
peyo |
0:cd5404401c2f | 168 | |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 169 | FUNC_EXIT_RC(IOT_SUCCESS); |
peyo |
0:cd5404401c2f | 170 | } |
peyo |
0:cd5404401c2f | 171 | |
peyo |
0:cd5404401c2f | 172 | /* Returns MAX_MESSAGE_HANDLERS value if no free index is available */ |
peyo |
0:cd5404401c2f | 173 | static uint32_t _aws_iot_mqtt_get_free_message_handler_index(AWS_IoT_Client *pClient) { |
peyo |
0:cd5404401c2f | 174 | uint32_t itr; |
peyo |
0:cd5404401c2f | 175 | |
peyo |
0:cd5404401c2f | 176 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 177 | |
peyo |
0:cd5404401c2f | 178 | for(itr = 0; itr < AWS_IOT_MQTT_NUM_SUBSCRIBE_HANDLERS; itr++) { |
peyo |
0:cd5404401c2f | 179 | if(pClient->clientData.messageHandlers[itr].topicName == NULL) { |
peyo |
0:cd5404401c2f | 180 | break; |
peyo |
0:cd5404401c2f | 181 | } |
peyo |
0:cd5404401c2f | 182 | } |
peyo |
0:cd5404401c2f | 183 | |
peyo |
0:cd5404401c2f | 184 | FUNC_EXIT_RC(itr); |
peyo |
0:cd5404401c2f | 185 | } |
peyo |
0:cd5404401c2f | 186 | |
peyo |
0:cd5404401c2f | 187 | /** |
peyo |
0:cd5404401c2f | 188 | * @brief Subscribe to an MQTT topic. |
peyo |
0:cd5404401c2f | 189 | * |
peyo |
0:cd5404401c2f | 190 | * Called to send a subscribe message to the broker requesting a subscription |
peyo |
0:cd5404401c2f | 191 | * to an MQTT topic. This is the internal function which is called by the |
peyo |
0:cd5404401c2f | 192 | * subscribe API to perform the operation. Not meant to be called directly as |
peyo |
0:cd5404401c2f | 193 | * it doesn't do validations or client state changes |
peyo |
0:cd5404401c2f | 194 | * @note Call is blocking. The call returns after the receipt of the SUBACK control packet. |
peyo |
0:cd5404401c2f | 195 | * |
peyo |
0:cd5404401c2f | 196 | * @param pClient Reference to the IoT Client |
peyo |
0:cd5404401c2f | 197 | * @param pTopicName Topic Name to publish to |
peyo |
0:cd5404401c2f | 198 | * @param topicNameLen Length of the topic name |
peyo |
0:cd5404401c2f | 199 | * @param pApplicationHandler_t Reference to the handler function for this subscription |
peyo |
0:cd5404401c2f | 200 | * |
peyo |
0:cd5404401c2f | 201 | * @return An IoT Error Type defining successful/failed subscription |
peyo |
0:cd5404401c2f | 202 | */ |
peyo |
0:cd5404401c2f | 203 | static IoT_Error_t _aws_iot_mqtt_internal_subscribe(AWS_IoT_Client *pClient, const char *pTopicName, |
peyo |
0:cd5404401c2f | 204 | uint16_t topicNameLen, QoS qos, |
peyo |
0:cd5404401c2f | 205 | pApplicationHandler_t pApplicationHandler, |
peyo |
0:cd5404401c2f | 206 | void *pApplicationHandlerData) { |
peyo |
0:cd5404401c2f | 207 | uint16_t txPacketId, rxPacketId; |
peyo |
0:cd5404401c2f | 208 | uint32_t serializedLen, indexOfFreeMessageHandler, count; |
peyo |
0:cd5404401c2f | 209 | IoT_Error_t rc; |
peyo |
0:cd5404401c2f | 210 | TimerAWS timer; |
peyo |
0:cd5404401c2f | 211 | QoS grantedQoS[3] = {QOS0, QOS0, QOS0}; |
peyo |
0:cd5404401c2f | 212 | |
peyo |
0:cd5404401c2f | 213 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 214 | init_timer(&timer); |
peyo |
0:cd5404401c2f | 215 | countdown_ms(&timer, pClient->clientData.commandTimeoutMs); |
peyo |
0:cd5404401c2f | 216 | |
peyo |
0:cd5404401c2f | 217 | serializedLen = 0; |
peyo |
0:cd5404401c2f | 218 | count = 0; |
peyo |
0:cd5404401c2f | 219 | txPacketId = aws_iot_mqtt_get_next_packet_id(pClient); |
peyo |
0:cd5404401c2f | 220 | rxPacketId = 0; |
peyo |
0:cd5404401c2f | 221 | |
peyo |
0:cd5404401c2f | 222 | rc = _aws_iot_mqtt_serialize_subscribe(pClient->clientData.writeBuf, pClient->clientData.writeBufSize, 0, |
peyo |
0:cd5404401c2f | 223 | txPacketId, 1, &pTopicName, &topicNameLen, &qos, &serializedLen); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 224 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 225 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 226 | } |
peyo |
0:cd5404401c2f | 227 | |
peyo |
0:cd5404401c2f | 228 | indexOfFreeMessageHandler = _aws_iot_mqtt_get_free_message_handler_index(pClient); |
peyo |
0:cd5404401c2f | 229 | if(AWS_IOT_MQTT_NUM_SUBSCRIBE_HANDLERS <= indexOfFreeMessageHandler) { |
peyo |
0:cd5404401c2f | 230 | FUNC_EXIT_RC(MQTT_MAX_SUBSCRIPTIONS_REACHED_ERROR); |
peyo |
0:cd5404401c2f | 231 | } |
peyo |
0:cd5404401c2f | 232 | |
peyo |
0:cd5404401c2f | 233 | /* send the subscribe packet */ |
peyo |
0:cd5404401c2f | 234 | rc = aws_iot_mqtt_internal_send_packet(pClient, serializedLen, &timer); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 235 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 236 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 237 | } |
peyo |
0:cd5404401c2f | 238 | |
peyo |
0:cd5404401c2f | 239 | /* wait for suback */ |
peyo |
0:cd5404401c2f | 240 | rc = aws_iot_mqtt_internal_wait_for_read(pClient, SUBACK, &timer); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 241 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 242 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 243 | } |
peyo |
0:cd5404401c2f | 244 | |
peyo |
0:cd5404401c2f | 245 | /* Granted QoS can be 0, 1 or 2 */ |
peyo |
0:cd5404401c2f | 246 | rc = _aws_iot_mqtt_deserialize_suback(&rxPacketId, 1, &count, grantedQoS, pClient->clientData.readBuf, |
peyo |
0:cd5404401c2f | 247 | pClient->clientData.readBufSize); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 248 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 249 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 250 | } |
peyo |
0:cd5404401c2f | 251 | |
peyo |
0:cd5404401c2f | 252 | /* TODO : Figure out how to test this before activating this check */ |
peyo |
0:cd5404401c2f | 253 | //if(txPacketId != rxPacketId) { |
peyo |
0:cd5404401c2f | 254 | /* Different SUBACK received than expected. Return error |
peyo |
0:cd5404401c2f | 255 | * This can cause issues if the request timeout value is too small */ |
peyo |
0:cd5404401c2f | 256 | // return RX_MESSAGE_INVALID_ERROR; |
peyo |
0:cd5404401c2f | 257 | //} |
peyo |
0:cd5404401c2f | 258 | |
peyo |
0:cd5404401c2f | 259 | pClient->clientData.messageHandlers[indexOfFreeMessageHandler].topicName = |
peyo |
0:cd5404401c2f | 260 | pTopicName; |
peyo |
0:cd5404401c2f | 261 | pClient->clientData.messageHandlers[indexOfFreeMessageHandler].topicNameLen = |
peyo |
0:cd5404401c2f | 262 | topicNameLen; |
peyo |
0:cd5404401c2f | 263 | pClient->clientData.messageHandlers[indexOfFreeMessageHandler].pApplicationHandler = |
peyo |
0:cd5404401c2f | 264 | pApplicationHandler; |
peyo |
0:cd5404401c2f | 265 | pClient->clientData.messageHandlers[indexOfFreeMessageHandler].pApplicationHandlerData = |
peyo |
0:cd5404401c2f | 266 | pApplicationHandlerData; |
peyo |
0:cd5404401c2f | 267 | pClient->clientData.messageHandlers[indexOfFreeMessageHandler].qos = qos; |
peyo |
0:cd5404401c2f | 268 | |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 269 | FUNC_EXIT_RC(IOT_SUCCESS); |
peyo |
0:cd5404401c2f | 270 | } |
peyo |
0:cd5404401c2f | 271 | |
peyo |
0:cd5404401c2f | 272 | /** |
peyo |
0:cd5404401c2f | 273 | * @brief Subscribe to an MQTT topic. |
peyo |
0:cd5404401c2f | 274 | * |
peyo |
0:cd5404401c2f | 275 | * Called to send a subscribe message to the broker requesting a subscription |
peyo |
0:cd5404401c2f | 276 | * to an MQTT topic. This is the outer function which does the validations and |
peyo |
0:cd5404401c2f | 277 | * calls the internal subscribe above to perform the actual operation. |
peyo |
0:cd5404401c2f | 278 | * It is also responsible for client state changes |
peyo |
0:cd5404401c2f | 279 | * @note Call is blocking. The call returns after the receipt of the SUBACK control packet. |
peyo |
0:cd5404401c2f | 280 | * |
peyo |
0:cd5404401c2f | 281 | * @param pClient Reference to the IoT Client |
peyo |
0:cd5404401c2f | 282 | * @param pTopicName Topic Name to publish to |
peyo |
0:cd5404401c2f | 283 | * @param topicNameLen Length of the topic name |
peyo |
0:cd5404401c2f | 284 | * @param pApplicationHandler_t Reference to the handler function for this subscription |
peyo |
0:cd5404401c2f | 285 | * |
peyo |
0:cd5404401c2f | 286 | * @return An IoT Error Type defining successful/failed subscription |
peyo |
0:cd5404401c2f | 287 | */ |
peyo |
0:cd5404401c2f | 288 | IoT_Error_t aws_iot_mqtt_subscribe(AWS_IoT_Client *pClient, const char *pTopicName, uint16_t topicNameLen, |
peyo |
0:cd5404401c2f | 289 | QoS qos, pApplicationHandler_t pApplicationHandler, void *pApplicationHandlerData) { |
peyo |
0:cd5404401c2f | 290 | ClientState clientState; |
peyo |
0:cd5404401c2f | 291 | IoT_Error_t rc, subRc; |
peyo |
0:cd5404401c2f | 292 | |
peyo |
0:cd5404401c2f | 293 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 294 | |
peyo |
0:cd5404401c2f | 295 | if(NULL == pClient || NULL == pTopicName || NULL == pApplicationHandler) { |
peyo |
0:cd5404401c2f | 296 | FUNC_EXIT_RC(NULL_VALUE_ERROR); |
peyo |
0:cd5404401c2f | 297 | } |
peyo |
0:cd5404401c2f | 298 | |
peyo |
0:cd5404401c2f | 299 | if(!aws_iot_mqtt_is_client_connected(pClient)) { |
peyo |
0:cd5404401c2f | 300 | FUNC_EXIT_RC(NETWORK_DISCONNECTED_ERROR); |
peyo |
0:cd5404401c2f | 301 | } |
peyo |
0:cd5404401c2f | 302 | |
peyo |
0:cd5404401c2f | 303 | clientState = aws_iot_mqtt_get_client_state(pClient); |
peyo |
0:cd5404401c2f | 304 | if(CLIENT_STATE_CONNECTED_IDLE != clientState && CLIENT_STATE_CONNECTED_WAIT_FOR_CB_RETURN != clientState) { |
peyo |
0:cd5404401c2f | 305 | FUNC_EXIT_RC(MQTT_CLIENT_NOT_IDLE_ERROR); |
peyo |
0:cd5404401c2f | 306 | } |
peyo |
0:cd5404401c2f | 307 | |
peyo |
0:cd5404401c2f | 308 | rc = aws_iot_mqtt_set_client_state(pClient, clientState, CLIENT_STATE_CONNECTED_SUBSCRIBE_IN_PROGRESS); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 309 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 310 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 311 | } |
peyo |
0:cd5404401c2f | 312 | |
peyo |
0:cd5404401c2f | 313 | subRc = _aws_iot_mqtt_internal_subscribe(pClient, pTopicName, topicNameLen, qos, |
peyo |
0:cd5404401c2f | 314 | pApplicationHandler, pApplicationHandlerData); |
peyo |
0:cd5404401c2f | 315 | |
peyo |
0:cd5404401c2f | 316 | rc = aws_iot_mqtt_set_client_state(pClient, CLIENT_STATE_CONNECTED_SUBSCRIBE_IN_PROGRESS, clientState); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 317 | if(IOT_SUCCESS == subRc && IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 318 | subRc = rc; |
peyo |
0:cd5404401c2f | 319 | } |
peyo |
0:cd5404401c2f | 320 | |
peyo |
0:cd5404401c2f | 321 | FUNC_EXIT_RC(subRc); |
peyo |
0:cd5404401c2f | 322 | } |
peyo |
0:cd5404401c2f | 323 | |
peyo |
0:cd5404401c2f | 324 | /** |
peyo |
0:cd5404401c2f | 325 | * @brief Subscribe to an MQTT topic. |
peyo |
0:cd5404401c2f | 326 | * |
peyo |
0:cd5404401c2f | 327 | * Called to send a subscribe message to the broker requesting a subscription |
peyo |
0:cd5404401c2f | 328 | * to an MQTT topic. |
peyo |
0:cd5404401c2f | 329 | * This is the internal function which is called by the resubscribe API to perform the operation. |
peyo |
0:cd5404401c2f | 330 | * Not meant to be called directly as it doesn't do validations or client state changes |
peyo |
0:cd5404401c2f | 331 | * @note Call is blocking. The call returns after the receipt of the SUBACK control packet. |
peyo |
0:cd5404401c2f | 332 | * |
peyo |
0:cd5404401c2f | 333 | * @param pClient Reference to the IoT Client |
peyo |
0:cd5404401c2f | 334 | * |
peyo |
0:cd5404401c2f | 335 | * @return An IoT Error Type defining successful/failed subscription |
peyo |
0:cd5404401c2f | 336 | */ |
peyo |
0:cd5404401c2f | 337 | static IoT_Error_t _aws_iot_mqtt_internal_resubscribe(AWS_IoT_Client *pClient) { |
peyo |
0:cd5404401c2f | 338 | uint16_t packetId; |
peyo |
0:cd5404401c2f | 339 | uint32_t len, count, existingSubCount, itr; |
peyo |
0:cd5404401c2f | 340 | IoT_Error_t rc; |
peyo |
0:cd5404401c2f | 341 | TimerAWS timer; |
peyo |
0:cd5404401c2f | 342 | QoS grantedQoS[3] = {QOS0, QOS0, QOS0}; |
peyo |
0:cd5404401c2f | 343 | |
peyo |
0:cd5404401c2f | 344 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 345 | |
peyo |
0:cd5404401c2f | 346 | packetId = 0; |
peyo |
0:cd5404401c2f | 347 | len = 0; |
peyo |
0:cd5404401c2f | 348 | count = 0; |
peyo |
0:cd5404401c2f | 349 | existingSubCount = _aws_iot_mqtt_get_free_message_handler_index(pClient); |
peyo |
0:cd5404401c2f | 350 | |
peyo |
0:cd5404401c2f | 351 | for(itr = 0; itr < existingSubCount; itr++) { |
peyo |
0:cd5404401c2f | 352 | init_timer(&timer); |
peyo |
0:cd5404401c2f | 353 | countdown_ms(&timer, pClient->clientData.commandTimeoutMs); |
peyo |
0:cd5404401c2f | 354 | |
peyo |
0:cd5404401c2f | 355 | rc = _aws_iot_mqtt_serialize_subscribe(pClient->clientData.writeBuf, pClient->clientData.writeBufSize, 0, |
peyo |
0:cd5404401c2f | 356 | aws_iot_mqtt_get_next_packet_id(pClient), 1, |
peyo |
0:cd5404401c2f | 357 | &(pClient->clientData.messageHandlers[itr].topicName), |
peyo |
0:cd5404401c2f | 358 | &(pClient->clientData.messageHandlers[itr].topicNameLen), |
peyo |
0:cd5404401c2f | 359 | &(pClient->clientData.messageHandlers[itr].qos), &len); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 360 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 361 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 362 | } |
peyo |
0:cd5404401c2f | 363 | |
peyo |
0:cd5404401c2f | 364 | /* send the subscribe packet */ |
peyo |
0:cd5404401c2f | 365 | rc = aws_iot_mqtt_internal_send_packet(pClient, len, &timer); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 366 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 367 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 368 | } |
peyo |
0:cd5404401c2f | 369 | |
peyo |
0:cd5404401c2f | 370 | /* wait for suback */ |
peyo |
0:cd5404401c2f | 371 | rc = aws_iot_mqtt_internal_wait_for_read(pClient, SUBACK, &timer); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 372 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 373 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 374 | } |
peyo |
0:cd5404401c2f | 375 | |
peyo |
0:cd5404401c2f | 376 | /* Granted QoS can be 0, 1 or 2 */ |
peyo |
0:cd5404401c2f | 377 | rc = _aws_iot_mqtt_deserialize_suback(&packetId, 1, &count, grantedQoS, pClient->clientData.readBuf, |
peyo |
0:cd5404401c2f | 378 | pClient->clientData.readBufSize); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 379 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 380 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 381 | } |
peyo |
0:cd5404401c2f | 382 | } |
peyo |
0:cd5404401c2f | 383 | |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 384 | FUNC_EXIT_RC(IOT_SUCCESS); |
peyo |
0:cd5404401c2f | 385 | } |
peyo |
0:cd5404401c2f | 386 | |
peyo |
0:cd5404401c2f | 387 | /** |
peyo |
0:cd5404401c2f | 388 | * @brief Subscribe to an MQTT topic. |
peyo |
0:cd5404401c2f | 389 | * |
peyo |
0:cd5404401c2f | 390 | * Called to send a subscribe message to the broker requesting a subscription |
peyo |
0:cd5404401c2f | 391 | * to an MQTT topic. |
peyo |
0:cd5404401c2f | 392 | * This is the outer function which does the validations and calls the internal resubscribe above |
peyo |
0:cd5404401c2f | 393 | * to perform the actual operation. It is also responsible for client state changes |
peyo |
0:cd5404401c2f | 394 | * @note Call is blocking. The call returns after the receipt of the SUBACK control packet. |
peyo |
0:cd5404401c2f | 395 | * |
peyo |
0:cd5404401c2f | 396 | * @param pClient Reference to the IoT Client |
peyo |
0:cd5404401c2f | 397 | * |
peyo |
0:cd5404401c2f | 398 | * @return An IoT Error Type defining successful/failed subscription |
peyo |
0:cd5404401c2f | 399 | */ |
peyo |
0:cd5404401c2f | 400 | IoT_Error_t aws_iot_mqtt_resubscribe(AWS_IoT_Client *pClient) { |
peyo |
0:cd5404401c2f | 401 | IoT_Error_t rc, resubRc; |
peyo |
0:cd5404401c2f | 402 | |
peyo |
0:cd5404401c2f | 403 | FUNC_ENTRY; |
peyo |
0:cd5404401c2f | 404 | |
peyo |
0:cd5404401c2f | 405 | if(NULL == pClient) { |
peyo |
0:cd5404401c2f | 406 | FUNC_EXIT_RC(NULL_VALUE_ERROR); |
peyo |
0:cd5404401c2f | 407 | } |
peyo |
0:cd5404401c2f | 408 | |
peyo |
0:cd5404401c2f | 409 | if(false == aws_iot_mqtt_is_client_connected(pClient)) { |
peyo |
0:cd5404401c2f | 410 | FUNC_EXIT_RC(NETWORK_DISCONNECTED_ERROR); |
peyo |
0:cd5404401c2f | 411 | } |
peyo |
0:cd5404401c2f | 412 | |
peyo |
0:cd5404401c2f | 413 | if(CLIENT_STATE_CONNECTED_IDLE != aws_iot_mqtt_get_client_state(pClient)) { |
peyo |
0:cd5404401c2f | 414 | FUNC_EXIT_RC(MQTT_CLIENT_NOT_IDLE_ERROR); |
peyo |
0:cd5404401c2f | 415 | } |
peyo |
0:cd5404401c2f | 416 | |
peyo |
0:cd5404401c2f | 417 | rc = aws_iot_mqtt_set_client_state(pClient, CLIENT_STATE_CONNECTED_IDLE, |
peyo |
0:cd5404401c2f | 418 | CLIENT_STATE_CONNECTED_RESUBSCRIBE_IN_PROGRESS); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 419 | if(IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 420 | FUNC_EXIT_RC(rc); |
peyo |
0:cd5404401c2f | 421 | } |
peyo |
0:cd5404401c2f | 422 | |
peyo |
0:cd5404401c2f | 423 | resubRc = _aws_iot_mqtt_internal_resubscribe(pClient); |
peyo |
0:cd5404401c2f | 424 | |
peyo |
0:cd5404401c2f | 425 | rc = aws_iot_mqtt_set_client_state(pClient, CLIENT_STATE_CONNECTED_RESUBSCRIBE_IN_PROGRESS, |
peyo |
0:cd5404401c2f | 426 | CLIENT_STATE_CONNECTED_IDLE); |
bcjun@aname.co.kr | 2:db59f45ad3d3 | 427 | if(IOT_SUCCESS == resubRc && IOT_SUCCESS != rc) { |
peyo |
0:cd5404401c2f | 428 | resubRc = rc; |
peyo |
0:cd5404401c2f | 429 | } |
peyo |
0:cd5404401c2f | 430 | |
peyo |
0:cd5404401c2f | 431 | FUNC_EXIT_RC(resubRc); |
peyo |
0:cd5404401c2f | 432 | } |
peyo |
0:cd5404401c2f | 433 | |
peyo |
0:cd5404401c2f | 434 | #ifdef __cplusplus |
peyo |
0:cd5404401c2f | 435 | } |
peyo |
0:cd5404401c2f | 436 | #endif |
peyo |
0:cd5404401c2f | 437 |