this is fork and i will modify for STM32

Fork of AWS-test by Pierre-Marie Ancèle

Committer:
bcjun@aname.co.kr
Date:
Fri Aug 04 15:34:19 2017 +0900
Revision:
3:1ef624d94403
Parent:
2:db59f45ad3d3
add esp82660-driver for NUCLEO_F401RE target.

Who changed what in which revision?

UserRevisionLine numberNew contents of line
peyo 0:cd5404401c2f 1 /*
peyo 0:cd5404401c2f 2 * Copyright 2015-2016 Amazon.com, Inc. or its affiliates. All Rights Reserved.
peyo 0:cd5404401c2f 3 *
peyo 0:cd5404401c2f 4 * Licensed under the Apache License, Version 2.0 (the "License").
peyo 0:cd5404401c2f 5 * You may not use this file except in compliance with the License.
peyo 0:cd5404401c2f 6 * A copy of the License is located at
peyo 0:cd5404401c2f 7 *
peyo 0:cd5404401c2f 8 * http://aws.amazon.com/apache2.0
peyo 0:cd5404401c2f 9 *
peyo 0:cd5404401c2f 10 * or in the "license" file accompanying this file. This file is distributed
peyo 0:cd5404401c2f 11 * on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either
peyo 0:cd5404401c2f 12 * express or implied. See the License for the specific language governing
peyo 0:cd5404401c2f 13 * permissions and limitations under the License.
peyo 0:cd5404401c2f 14 */
peyo 0:cd5404401c2f 15
peyo 0:cd5404401c2f 16 // Based on Eclipse Paho.
peyo 0:cd5404401c2f 17 /*******************************************************************************
peyo 0:cd5404401c2f 18 * Copyright (c) 2014 IBM Corp.
peyo 0:cd5404401c2f 19 *
peyo 0:cd5404401c2f 20 * All rights reserved. This program and the accompanying materials
peyo 0:cd5404401c2f 21 * are made available under the terms of the Eclipse Public License v1.0
peyo 0:cd5404401c2f 22 * and Eclipse Distribution License v1.0 which accompany this distribution.
peyo 0:cd5404401c2f 23 *
peyo 0:cd5404401c2f 24 * The Eclipse Public License is available at
peyo 0:cd5404401c2f 25 * http://www.eclipse.org/legal/epl-v10.html
peyo 0:cd5404401c2f 26 * and the Eclipse Distribution License is available at
peyo 0:cd5404401c2f 27 * http://www.eclipse.org/org/documents/edl-v10.php.
peyo 0:cd5404401c2f 28 *
peyo 0:cd5404401c2f 29 * Contributors:
peyo 0:cd5404401c2f 30 * Allan Stockdill-Mander/Ian Craggs - initial API and implementation and/or initial documentation
peyo 0:cd5404401c2f 31 *******************************************************************************/
peyo 0:cd5404401c2f 32
peyo 0:cd5404401c2f 33 /**
peyo 0:cd5404401c2f 34 * @file aws_iot_mqtt_client.c
peyo 0:cd5404401c2f 35 * @brief MQTT client API definitions
peyo 0:cd5404401c2f 36 */
peyo 0:cd5404401c2f 37
peyo 0:cd5404401c2f 38 #ifdef __cplusplus
peyo 0:cd5404401c2f 39 extern "C" {
peyo 0:cd5404401c2f 40 #endif
peyo 0:cd5404401c2f 41
peyo 0:cd5404401c2f 42 #include "aws_iot_log.h"
peyo 0:cd5404401c2f 43 #include "aws_iot_mqtt_client_interface.h"
peyo 0:cd5404401c2f 44
peyo 0:cd5404401c2f 45 #ifdef _ENABLE_THREAD_SUPPORT_
peyo 0:cd5404401c2f 46 #include "threads_interface.h"
peyo 0:cd5404401c2f 47 #endif
peyo 0:cd5404401c2f 48
peyo 0:cd5404401c2f 49 const IoT_Client_Init_Params iotClientInitParamsDefault = IoT_Client_Init_Params_initializer;
peyo 0:cd5404401c2f 50 const IoT_MQTT_Will_Options iotMqttWillOptionsDefault = IoT_MQTT_Will_Options_Initializer;
peyo 0:cd5404401c2f 51 const IoT_Client_Connect_Params iotClientConnectParamsDefault = IoT_Client_Connect_Params_initializer;
peyo 0:cd5404401c2f 52
peyo 0:cd5404401c2f 53 ClientState aws_iot_mqtt_get_client_state(AWS_IoT_Client *pClient) {
peyo 0:cd5404401c2f 54 FUNC_ENTRY;
peyo 0:cd5404401c2f 55 if(NULL == pClient) {
peyo 0:cd5404401c2f 56 return CLIENT_STATE_INVALID;
peyo 0:cd5404401c2f 57 }
peyo 0:cd5404401c2f 58
peyo 0:cd5404401c2f 59 FUNC_EXIT_RC(pClient->clientStatus.clientState);
peyo 0:cd5404401c2f 60 }
peyo 0:cd5404401c2f 61
peyo 0:cd5404401c2f 62 #ifdef _ENABLE_THREAD_SUPPORT_
peyo 0:cd5404401c2f 63 IoT_Error_t aws_iot_mqtt_client_lock_mutex(AWS_IoT_Client *pClient, IoT_Mutex_t *pMutex) {
peyo 0:cd5404401c2f 64 FUNC_ENTRY;
bcjun@aname.co.kr 2:db59f45ad3d3 65 IoT_Error_t threadRc = IOT_FAILURE;
peyo 0:cd5404401c2f 66
peyo 0:cd5404401c2f 67 if(NULL == pClient || NULL == pMutex){
peyo 0:cd5404401c2f 68 FUNC_EXIT_RC(NULL_VALUE_ERROR);
peyo 0:cd5404401c2f 69 }
peyo 0:cd5404401c2f 70
peyo 0:cd5404401c2f 71 if(false == pClient->clientData.isBlockOnThreadLockEnabled) {
peyo 0:cd5404401c2f 72 threadRc = aws_iot_thread_mutex_trylock(pMutex);
peyo 0:cd5404401c2f 73 } else {
peyo 0:cd5404401c2f 74 threadRc = aws_iot_thread_mutex_lock(pMutex);
peyo 0:cd5404401c2f 75 /* Should never return Error because the above request blocks until lock is obtained */
peyo 0:cd5404401c2f 76 }
peyo 0:cd5404401c2f 77
bcjun@aname.co.kr 2:db59f45ad3d3 78 if(IOT_SUCCESS != threadRc) {
peyo 0:cd5404401c2f 79 FUNC_EXIT_RC(threadRc);
peyo 0:cd5404401c2f 80 }
peyo 0:cd5404401c2f 81
bcjun@aname.co.kr 2:db59f45ad3d3 82 FUNC_EXIT_RC(IOT_SUCCESS);
peyo 0:cd5404401c2f 83 }
peyo 0:cd5404401c2f 84
peyo 0:cd5404401c2f 85 IoT_Error_t aws_iot_mqtt_client_unlock_mutex(AWS_IoT_Client *pClient, IoT_Mutex_t *pMutex) {
peyo 0:cd5404401c2f 86 if(NULL == pClient || NULL == pMutex) {
peyo 0:cd5404401c2f 87 return NULL_VALUE_ERROR;
peyo 0:cd5404401c2f 88 }
peyo 0:cd5404401c2f 89 IOT_UNUSED(pClient);
peyo 0:cd5404401c2f 90 return aws_iot_thread_mutex_unlock(pMutex);
peyo 0:cd5404401c2f 91 }
peyo 0:cd5404401c2f 92 #endif
peyo 0:cd5404401c2f 93
peyo 0:cd5404401c2f 94 IoT_Error_t aws_iot_mqtt_set_client_state(AWS_IoT_Client *pClient, ClientState expectedCurrentState,
peyo 0:cd5404401c2f 95 ClientState newState) {
peyo 0:cd5404401c2f 96 IoT_Error_t rc;
peyo 0:cd5404401c2f 97 #ifdef _ENABLE_THREAD_SUPPORT_
bcjun@aname.co.kr 2:db59f45ad3d3 98 IoT_Error_t threadRc = IOT_FAILURE;
peyo 0:cd5404401c2f 99 #endif
peyo 0:cd5404401c2f 100
peyo 0:cd5404401c2f 101 FUNC_ENTRY;
peyo 0:cd5404401c2f 102 if(NULL == pClient) {
peyo 0:cd5404401c2f 103 FUNC_EXIT_RC(NULL_VALUE_ERROR);
peyo 0:cd5404401c2f 104 }
peyo 0:cd5404401c2f 105
peyo 0:cd5404401c2f 106 #ifdef _ENABLE_THREAD_SUPPORT_
peyo 0:cd5404401c2f 107 rc = aws_iot_mqtt_client_lock_mutex(pClient, &(pClient->clientData.state_change_mutex));
bcjun@aname.co.kr 2:db59f45ad3d3 108 if(IOT_SUCCESS != rc) {
peyo 0:cd5404401c2f 109 return rc;
peyo 0:cd5404401c2f 110 }
peyo 0:cd5404401c2f 111 #endif
peyo 0:cd5404401c2f 112 if(expectedCurrentState == aws_iot_mqtt_get_client_state(pClient)) {
peyo 0:cd5404401c2f 113 pClient->clientStatus.clientState = newState;
bcjun@aname.co.kr 2:db59f45ad3d3 114 rc = IOT_SUCCESS;
peyo 0:cd5404401c2f 115 } else {
peyo 0:cd5404401c2f 116 rc = MQTT_UNEXPECTED_CLIENT_STATE_ERROR;
peyo 0:cd5404401c2f 117 }
peyo 0:cd5404401c2f 118
peyo 0:cd5404401c2f 119 #ifdef _ENABLE_THREAD_SUPPORT_
peyo 0:cd5404401c2f 120 threadRc = aws_iot_mqtt_client_unlock_mutex(pClient, &(pClient->clientData.state_change_mutex));
bcjun@aname.co.kr 2:db59f45ad3d3 121 if(IOT_SUCCESS == rc && IOT_SUCCESS != threadRc) {
peyo 0:cd5404401c2f 122 rc = threadRc;
peyo 0:cd5404401c2f 123 }
peyo 0:cd5404401c2f 124 #endif
peyo 0:cd5404401c2f 125
peyo 0:cd5404401c2f 126 FUNC_EXIT_RC(rc);
peyo 0:cd5404401c2f 127 }
peyo 0:cd5404401c2f 128
peyo 0:cd5404401c2f 129 IoT_Error_t aws_iot_mqtt_set_connect_params(AWS_IoT_Client *pClient, IoT_Client_Connect_Params *pNewConnectParams) {
peyo 0:cd5404401c2f 130 FUNC_ENTRY;
peyo 0:cd5404401c2f 131 if(NULL == pClient || NULL == pNewConnectParams) {
peyo 0:cd5404401c2f 132 FUNC_EXIT_RC(NULL_VALUE_ERROR);
peyo 0:cd5404401c2f 133 }
peyo 0:cd5404401c2f 134
peyo 0:cd5404401c2f 135 pClient->clientData.options.isWillMsgPresent = pNewConnectParams->isWillMsgPresent;
peyo 0:cd5404401c2f 136 pClient->clientData.options.MQTTVersion = pNewConnectParams->MQTTVersion;
peyo 0:cd5404401c2f 137 pClient->clientData.options.pClientID = pNewConnectParams->pClientID;
peyo 0:cd5404401c2f 138 pClient->clientData.options.clientIDLen = pNewConnectParams->clientIDLen;
peyo 0:cd5404401c2f 139 pClient->clientData.options.pUsername = pNewConnectParams->pUsername;
peyo 0:cd5404401c2f 140 pClient->clientData.options.usernameLen = pNewConnectParams->usernameLen;
peyo 0:cd5404401c2f 141 pClient->clientData.options.pPassword = pNewConnectParams->pUsername;
peyo 0:cd5404401c2f 142 pClient->clientData.options.passwordLen = pNewConnectParams->passwordLen;
peyo 0:cd5404401c2f 143 pClient->clientData.options.will.pTopicName = pNewConnectParams->will.pTopicName;
peyo 0:cd5404401c2f 144 pClient->clientData.options.will.topicNameLen = pNewConnectParams->will.topicNameLen;
peyo 0:cd5404401c2f 145 pClient->clientData.options.will.pMessage = pNewConnectParams->will.pMessage;
peyo 0:cd5404401c2f 146 pClient->clientData.options.will.msgLen = pNewConnectParams->will.msgLen;
peyo 0:cd5404401c2f 147 pClient->clientData.options.will.qos = pNewConnectParams->will.qos;
peyo 0:cd5404401c2f 148 pClient->clientData.options.will.isRetained = pNewConnectParams->will.isRetained;
peyo 0:cd5404401c2f 149 pClient->clientData.options.keepAliveIntervalInSec = pNewConnectParams->keepAliveIntervalInSec;
peyo 0:cd5404401c2f 150 pClient->clientData.options.isCleanSession = pNewConnectParams->isCleanSession;
peyo 0:cd5404401c2f 151
bcjun@aname.co.kr 2:db59f45ad3d3 152 FUNC_EXIT_RC(IOT_SUCCESS);
peyo 0:cd5404401c2f 153 }
peyo 0:cd5404401c2f 154
peyo 0:cd5404401c2f 155 IoT_Error_t aws_iot_mqtt_init(AWS_IoT_Client *pClient, IoT_Client_Init_Params *pInitParams) {
peyo 0:cd5404401c2f 156 uint32_t i;
peyo 0:cd5404401c2f 157 IoT_Error_t rc;
peyo 0:cd5404401c2f 158 IoT_Client_Connect_Params default_options = IoT_Client_Connect_Params_initializer;
peyo 0:cd5404401c2f 159
peyo 0:cd5404401c2f 160 FUNC_ENTRY;
peyo 0:cd5404401c2f 161
peyo 0:cd5404401c2f 162 if(NULL == pClient || NULL == pInitParams || NULL == pInitParams->pHostURL || 0 == pInitParams->port /*||
peyo 0:cd5404401c2f 163 NULL == pInitParams->pRootCALocation || NULL == pInitParams->pDevicePrivateKeyLocation ||
peyo 0:cd5404401c2f 164 NULL == pInitParams->pDeviceCertLocation*/) {
peyo 0:cd5404401c2f 165 FUNC_EXIT_RC(NULL_VALUE_ERROR);
peyo 0:cd5404401c2f 166 }
peyo 0:cd5404401c2f 167
peyo 0:cd5404401c2f 168 for(i = 0; i < AWS_IOT_MQTT_NUM_SUBSCRIBE_HANDLERS; ++i) {
peyo 0:cd5404401c2f 169 pClient->clientData.messageHandlers[i].topicName = NULL;
peyo 0:cd5404401c2f 170 pClient->clientData.messageHandlers[i].pApplicationHandler = NULL;
peyo 0:cd5404401c2f 171 pClient->clientData.messageHandlers[i].pApplicationHandlerData = NULL;
peyo 0:cd5404401c2f 172 pClient->clientData.messageHandlers[i].qos = QOS0;
peyo 0:cd5404401c2f 173 }
peyo 0:cd5404401c2f 174
peyo 0:cd5404401c2f 175 pClient->clientData.packetTimeoutMs = pInitParams->mqttPacketTimeout_ms;
peyo 0:cd5404401c2f 176 pClient->clientData.commandTimeoutMs = pInitParams->mqttCommandTimeout_ms;
peyo 0:cd5404401c2f 177 pClient->clientData.writeBufSize = AWS_IOT_MQTT_TX_BUF_LEN;
peyo 0:cd5404401c2f 178 pClient->clientData.readBufSize = AWS_IOT_MQTT_RX_BUF_LEN;
peyo 0:cd5404401c2f 179 pClient->clientData.counterNetworkDisconnected = 0;
peyo 0:cd5404401c2f 180 pClient->clientData.disconnectHandler = pInitParams->disconnectHandler;
peyo 0:cd5404401c2f 181 pClient->clientData.disconnectHandlerData = pInitParams->disconnectHandlerData;
peyo 0:cd5404401c2f 182 pClient->clientData.nextPacketId = 1;
peyo 0:cd5404401c2f 183
peyo 0:cd5404401c2f 184 /* Initialize default connection options */
peyo 0:cd5404401c2f 185 rc = aws_iot_mqtt_set_connect_params(pClient, &default_options);
bcjun@aname.co.kr 2:db59f45ad3d3 186 if(IOT_SUCCESS != rc) {
peyo 0:cd5404401c2f 187 FUNC_EXIT_RC(rc);
peyo 0:cd5404401c2f 188 }
peyo 0:cd5404401c2f 189
peyo 0:cd5404401c2f 190 #ifdef _ENABLE_THREAD_SUPPORT_
peyo 0:cd5404401c2f 191 pClient->clientData.isBlockOnThreadLockEnabled = pInitParams->isBlockOnThreadLockEnabled;
peyo 0:cd5404401c2f 192 rc = aws_iot_thread_mutex_init(&(pClient->clientData.state_change_mutex));
bcjun@aname.co.kr 2:db59f45ad3d3 193 if(IOT_SUCCESS != rc) {
peyo 0:cd5404401c2f 194 FUNC_EXIT_RC(rc);
peyo 0:cd5404401c2f 195 }
peyo 0:cd5404401c2f 196 rc = aws_iot_thread_mutex_init(&(pClient->clientData.tls_read_mutex));
bcjun@aname.co.kr 2:db59f45ad3d3 197 if(IOT_SUCCESS != rc) {
peyo 0:cd5404401c2f 198 FUNC_EXIT_RC(rc);
peyo 0:cd5404401c2f 199 }
peyo 0:cd5404401c2f 200 rc = aws_iot_thread_mutex_init(&(pClient->clientData.tls_write_mutex));
bcjun@aname.co.kr 2:db59f45ad3d3 201 if(IOT_SUCCESS != rc) {
peyo 0:cd5404401c2f 202 FUNC_EXIT_RC(rc);
peyo 0:cd5404401c2f 203 }
peyo 0:cd5404401c2f 204 #endif
peyo 0:cd5404401c2f 205
peyo 0:cd5404401c2f 206 pClient->clientStatus.isPingOutstanding = 0;
peyo 0:cd5404401c2f 207 pClient->clientStatus.isAutoReconnectEnabled = pInitParams->enableAutoReconnect;
peyo 0:cd5404401c2f 208
peyo 0:cd5404401c2f 209 rc = iot_tls_init(&(pClient->networkStack), pInitParams->pRootCALocation, pInitParams->pDeviceCertLocation,
peyo 0:cd5404401c2f 210 pInitParams->pDevicePrivateKeyLocation, pInitParams->pHostURL, pInitParams->port,
peyo 0:cd5404401c2f 211 pInitParams->tlsHandshakeTimeout_ms, pInitParams->isSSLHostnameVerify);
peyo 0:cd5404401c2f 212
bcjun@aname.co.kr 2:db59f45ad3d3 213 if(IOT_SUCCESS != rc) {
peyo 0:cd5404401c2f 214 pClient->clientStatus.clientState = CLIENT_STATE_INVALID;
peyo 0:cd5404401c2f 215 FUNC_EXIT_RC(rc);
peyo 0:cd5404401c2f 216 }
peyo 0:cd5404401c2f 217
peyo 0:cd5404401c2f 218 init_timer(&(pClient->pingTimer));
peyo 0:cd5404401c2f 219 init_timer(&(pClient->reconnectDelayTimer));
peyo 0:cd5404401c2f 220
peyo 0:cd5404401c2f 221 pClient->clientStatus.clientState = CLIENT_STATE_INITIALIZED;
peyo 0:cd5404401c2f 222
bcjun@aname.co.kr 2:db59f45ad3d3 223 FUNC_EXIT_RC(IOT_SUCCESS);
peyo 0:cd5404401c2f 224 }
peyo 0:cd5404401c2f 225
peyo 0:cd5404401c2f 226 uint16_t aws_iot_mqtt_get_next_packet_id(AWS_IoT_Client *pClient) {
peyo 0:cd5404401c2f 227 return pClient->clientData.nextPacketId = (uint16_t) ((MAX_PACKET_ID == pClient->clientData.nextPacketId) ? 1 : (
peyo 0:cd5404401c2f 228 pClient->clientData.nextPacketId + 1));
peyo 0:cd5404401c2f 229 }
peyo 0:cd5404401c2f 230
peyo 0:cd5404401c2f 231 bool aws_iot_mqtt_is_client_connected(AWS_IoT_Client *pClient) {
peyo 0:cd5404401c2f 232 bool isConnected;
peyo 0:cd5404401c2f 233
peyo 0:cd5404401c2f 234 FUNC_ENTRY;
peyo 0:cd5404401c2f 235
peyo 0:cd5404401c2f 236 if(NULL == pClient) {
peyo 0:cd5404401c2f 237 IOT_WARN(" Client is null! ");
peyo 0:cd5404401c2f 238 FUNC_EXIT_RC(false);
peyo 0:cd5404401c2f 239 }
peyo 0:cd5404401c2f 240
peyo 0:cd5404401c2f 241 switch(pClient->clientStatus.clientState) {
peyo 0:cd5404401c2f 242 case CLIENT_STATE_INVALID:
peyo 0:cd5404401c2f 243 case CLIENT_STATE_INITIALIZED:
peyo 0:cd5404401c2f 244 case CLIENT_STATE_CONNECTING:
peyo 0:cd5404401c2f 245 isConnected = false;
peyo 0:cd5404401c2f 246 break;
peyo 0:cd5404401c2f 247 case CLIENT_STATE_CONNECTED_IDLE:
peyo 0:cd5404401c2f 248 case CLIENT_STATE_CONNECTED_YIELD_IN_PROGRESS:
peyo 0:cd5404401c2f 249 case CLIENT_STATE_CONNECTED_PUBLISH_IN_PROGRESS:
peyo 0:cd5404401c2f 250 case CLIENT_STATE_CONNECTED_SUBSCRIBE_IN_PROGRESS:
peyo 0:cd5404401c2f 251 case CLIENT_STATE_CONNECTED_UNSUBSCRIBE_IN_PROGRESS:
peyo 0:cd5404401c2f 252 case CLIENT_STATE_CONNECTED_RESUBSCRIBE_IN_PROGRESS:
peyo 0:cd5404401c2f 253 case CLIENT_STATE_CONNECTED_WAIT_FOR_CB_RETURN:
peyo 0:cd5404401c2f 254 isConnected = true;
peyo 0:cd5404401c2f 255 break;
peyo 0:cd5404401c2f 256 case CLIENT_STATE_DISCONNECTING:
peyo 0:cd5404401c2f 257 case CLIENT_STATE_DISCONNECTED_ERROR:
peyo 0:cd5404401c2f 258 case CLIENT_STATE_DISCONNECTED_MANUALLY:
peyo 0:cd5404401c2f 259 case CLIENT_STATE_PENDING_RECONNECT:
peyo 0:cd5404401c2f 260 default:
peyo 0:cd5404401c2f 261 isConnected = false;
peyo 0:cd5404401c2f 262 break;
peyo 0:cd5404401c2f 263 }
peyo 0:cd5404401c2f 264
peyo 0:cd5404401c2f 265 FUNC_EXIT_RC(isConnected);
peyo 0:cd5404401c2f 266 }
peyo 0:cd5404401c2f 267
peyo 0:cd5404401c2f 268 bool aws_iot_is_autoreconnect_enabled(AWS_IoT_Client *pClient) {
peyo 0:cd5404401c2f 269 FUNC_ENTRY;
peyo 0:cd5404401c2f 270 if(NULL == pClient) {
peyo 0:cd5404401c2f 271 IOT_WARN(" Client is null! ");
peyo 0:cd5404401c2f 272 FUNC_EXIT_RC(false);
peyo 0:cd5404401c2f 273 }
peyo 0:cd5404401c2f 274
peyo 0:cd5404401c2f 275 FUNC_EXIT_RC(pClient->clientStatus.isAutoReconnectEnabled);
peyo 0:cd5404401c2f 276 }
peyo 0:cd5404401c2f 277
peyo 0:cd5404401c2f 278 IoT_Error_t aws_iot_mqtt_autoreconnect_set_status(AWS_IoT_Client *pClient, bool newStatus) {
peyo 0:cd5404401c2f 279 FUNC_ENTRY;
peyo 0:cd5404401c2f 280 if(NULL == pClient) {
peyo 0:cd5404401c2f 281 FUNC_EXIT_RC(NULL_VALUE_ERROR);
peyo 0:cd5404401c2f 282 }
peyo 0:cd5404401c2f 283 pClient->clientStatus.isAutoReconnectEnabled = newStatus;
bcjun@aname.co.kr 2:db59f45ad3d3 284 FUNC_EXIT_RC(IOT_SUCCESS);
peyo 0:cd5404401c2f 285 }
peyo 0:cd5404401c2f 286
peyo 0:cd5404401c2f 287 IoT_Error_t aws_iot_mqtt_set_disconnect_handler(AWS_IoT_Client *pClient, iot_disconnect_handler pDisconnectHandler,
peyo 0:cd5404401c2f 288 void *pDisconnectHandlerData) {
peyo 0:cd5404401c2f 289 FUNC_ENTRY;
peyo 0:cd5404401c2f 290 if(NULL == pClient || NULL == pDisconnectHandler) {
peyo 0:cd5404401c2f 291 FUNC_EXIT_RC(NULL_VALUE_ERROR);
peyo 0:cd5404401c2f 292 }
peyo 0:cd5404401c2f 293
peyo 0:cd5404401c2f 294 pClient->clientData.disconnectHandler = pDisconnectHandler;
peyo 0:cd5404401c2f 295 pClient->clientData.disconnectHandlerData = pDisconnectHandlerData;
bcjun@aname.co.kr 2:db59f45ad3d3 296 FUNC_EXIT_RC(IOT_SUCCESS);
peyo 0:cd5404401c2f 297 }
peyo 0:cd5404401c2f 298
peyo 0:cd5404401c2f 299 uint32_t aws_iot_mqtt_get_network_disconnected_count(AWS_IoT_Client *pClient) {
peyo 0:cd5404401c2f 300 return pClient->clientData.counterNetworkDisconnected;
peyo 0:cd5404401c2f 301 }
peyo 0:cd5404401c2f 302
peyo 0:cd5404401c2f 303 void aws_iot_mqtt_reset_network_disconnected_count(AWS_IoT_Client *pClient) {
peyo 0:cd5404401c2f 304 pClient->clientData.counterNetworkDisconnected = 0;
peyo 0:cd5404401c2f 305 }
peyo 0:cd5404401c2f 306
peyo 0:cd5404401c2f 307 #ifdef __cplusplus
peyo 0:cd5404401c2f 308 }
peyo 0:cd5404401c2f 309 #endif
peyo 0:cd5404401c2f 310