GSMA version

Dependencies:   FXOS8700CQ mbed sfh7779

Fork of StarterKit by Rick McConney

Revision:
21:d0038d14ee7c
Parent:
13:df9c49662797
Child:
23:d6ceeb6d85ed
--- a/config_me.h	Wed Jul 13 17:57:14 2016 +0000
+++ b/config_me.h	Wed Jul 13 18:34:56 2016 +0000
@@ -2,19 +2,31 @@
 #define __CONFIG_ME_H_
 
 // User must set these for own context:
-//static const char * MY_SERVER_URL       = "run-east.att.io";
+
+// This is the server's base URL name.  Example "www.google.com"
 static const char * MY_SERVER_URL       = "run-west.att.io";
+
+// These are FLOW variables that must be read from your own FLOW account and placed here:
 #define FLOW_BASE_URL                   "/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow"
 #define FLOW_INPUT_NAME                 "/climate"
-#define FLOW_DEVICE_NAME                "vstarterkit001"
+
+// This in most cases should be left alone but is here if you want to talk a differnet protocol:
 #define FLOW_URL_TYPE                   " HTTP/1.1\r\nHost: "
 
+// This just needs to be a unique identifier 1 for each board that talks to each FLOW account. 
+// If you only have one board then you can just leave this alone but you have to use this
+// identifier in your FLOW setup for identification.
+#define FLOW_DEVICE_NAME                "vstarterkit001"
+
+// These are for?
 #define TEMP_HUMIDITY_ONLY                      1
 #define TEMP_HUMIDITY_ACCELEROMETER             2
 #define TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS 3
-static int iSensorsToReport = TEMP_HUMIDITY_ONLY;
 
+// This is the APN name for the cellular network, you will need to change this, check the instructions included with your SIM card kit:
 static const char * MY_APN_STR          = "m2m.com.attz";
-static const char * MY_PORT_STR         = "80"; //This is for normal HTTP.  If you want to use TCP to a specific port, change that here
+
+//This is for normal HTTP.  If you want to use TCP to a specific port, change that here:
+static const char * MY_PORT_STR         = "80";
 
 #endif