config_me.h
- Committer:
- elmkom
- Date:
- 2016-09-19
- Revision:
- 35:2e864bae3af0
- Parent:
- 31:d7c386d2e95a
- Child:
- 38:532a0d929756
File content as of revision 35:2e864bae3af0:
#ifndef __CONFIG_ME_H_
#define __CONFIG_ME_H_
// User must set these for own context:
// This is the server's base URL name. Example "www.google.com"
// Note that when you Fork a FLOW, it will typically assign either
// "run-east.att.io" or "run-west.att.io", so be sure to check this.
static const char * MY_SERVER_URL = "run-east.att.io";
// These are FLOW fields from the Endpoints tab:
#define FLOW_BASE_URL "/a80556051c438/f4cd2ed65f73/7ecb40fcd115f7a/in/flow"
#define FLOW_INPUT_NAME "/shelf"
// Unless you want to use a different protocol, this field should be left as is:
#define FLOW_URL_TYPE " HTTP/1.1\r\nHost: "
// This identifier specifies with which FLOW device you are communicating.
// If you only have one devive there then you can just leave this as is.
// Once your FLOW device has been initialized (Virtual Device Initialize clicked),
// the Virtual Device will show up in M2X. This is its "DEVICE SERIAL" field
#define FLOW_DEVICE_NAME "vstarterkit001"
// This constant defines how often sensors are read and sent up to FLOW
#define SENSOR_UPDATE_INTERVAL_MS 5000; //5 seconds
// Specify here how many sensor parameters you want reported to FLOW.
// You can use only the temperature and humidity from the shield HTS221
// or you can add the reading of the FXO8700CQ motion sensor on the FRDM-K64F board
// or if you have a SiLabs PMOD plugged into the shield, you can add its proximity sensor,
// UV light, visible ambient light and infrared ambient light readings
#define TEMP_HUMIDITY_ONLY 1
#define TEMP_HUMIDITY_ACCELEROMETER 2
#define TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS 3
#define PROXIMITY 4
static int iSensorsToReport = PROXIMITY; //TEMP_HUMIDITY_ONLY; //modify this to change your selection
// This is the APN name for the cellular network, you will need to change this, check the instructions included with your SIM card kit:
static const char * MY_APN_STR = "m2m.com.attz";
//This is for normal HTTP. If you want to use TCP to a specific port, change that here:
static const char * MY_PORT_STR = "80";
#endif