Important changes to repositories hosted on mbed.com
Mbed hosted mercurial repositories are deprecated and are due to be permanently deleted in July 2026.
To keep a copy of this software download the repository Zip archive or clone locally using Mercurial.
It is also possible to export all your personal repositories from the account settings page.
Diff: main.cpp
- Revision:
- 4:ab834eebd496
- Parent:
- 3:4dcadafb89a2
- Child:
- 5:e4e96d1b446f
--- a/main.cpp Tue Nov 16 21:21:10 2021 +0000
+++ b/main.cpp Wed Nov 17 15:13:38 2021 +0000
@@ -13,12 +13,18 @@
/*---------------------- Initial setup ----------------------*/
// Serial port
Serial pc(USBTX, USBRX);
-// Ticker for logging at a fixed frequency
-Ticker datalog;
-bool tickerActivated = false;
-void log_data(){
- tickerActivated = true;
+// Ticker for logging from LTC at a fixed frequency
+Ticker LTC_log;
+// Ticker for logging from force sensor, sending ethernet message at a fixed frequency
+Ticker eth_send;
+bool LTC_ticker_activated = false;
+bool eth_ticker_activated = false;
+void log_LTC_data(){
+ LTC_ticker_activated = true;
}
+void send_eth_data(){
+ eth_ticker_activated = true;
+}
/*---------------------- Ethernet setup ----------------------*/
const int SERVER_PORT = 2;
@@ -62,6 +68,8 @@
uint8_t rx_buff[BUFF_SIZE]; //each is an 8-bit word
ltc_spi adc_data;
int16_t ati_data[6];
+float ati_filt[6];
+float FILT_COEF = 0.05f;
// calibration matrix for ATI sensor
float Fxc[6] = {-0.1971322934773, -0.04349257334311, 2.298051028435, -80.35044049387, 1.362983909976, 78.23673392118};
@@ -128,12 +136,20 @@
ati_data[5] = adc_data.channel[5].cnv_upper<<8 | adc_data.channel[5].cnv_lower;
}
+void filter_LTC_data(){
+ // filter the incoming LTC data
+ for(int i=0; i<6; i++){
+ ati_filt[i] = FILT_COEF*(float)ati_data[i] + (1.0-FILT_COEF)*ati_filt[i];
+ }
+}
+
// convert integer readings to voltages to f/t values
void convert_LTC_data(){
// dummy buffer to store converted ADC vals
float buff[6];
for(int i=0; i<6; i++){
- buff[i] = CONV_FACTOR*((float)ati_data[i]-bias[i]); // bias[] is in same units as msg[]
+ //buff[i] = CONV_FACTOR*((float)ati_data[i]-bias[i]); // bias[] is in same units as msg[] // for non-filtered LTC data
+ buff[i] = CONV_FACTOR*(ati_filt[i]-bias[i]); // for filtered data
ft_data[i] = 0; // also zero out ft_data here
}
// convert each f/t value separately
@@ -387,22 +403,31 @@
}
pc.printf("ATI sensor is calibrated with biases of: %.2f, %.2f, %.2f, %.2f, %.2f, %.2f \n\r", bias[0],bias[1],bias[2],bias[3],bias[4],bias[5]);
- // Attach sampling interrupt
+ // Attach sampling and sending interrupts
// datalog.attach_us(&log_data,50000); // 1000us = 1ms (10000 = 10 ms = 100 Hz)
- datalog.attach(&log_data,0.1); // 10Hz
+ LTC_log.attach_us(&log_LTC_data,5000); // 200Hz
+ eth_send.attach(&send_eth_data,0.1); // 10Hz
+
while (true) {
- if(tickerActivated == true) {
-
- tickerActivated = false;
+ if(LTC_ticker_activated == true) {
+ // Clear flag
+ LTC_ticker_activated = false;
+ // Sample from LTC chip
+ // TODO: sample LTC chip at a much higher frequency (10kHz?)
+ read_LTC_data();
+ filter_LTC_data();
+ }
+
+ if(eth_ticker_activated == true) {
+ // Clear flag
+ eth_ticker_activated = false;
- // Sample from LTC chip
- read_LTC_data();
convert_LTC_data(); // TODO: remove this eventually, since we'll convert the data after sending over ethernet
// Print received data
//pc.printf("%6d,%6d,%6d,%6d,%6d,%6d\n\r", ati_data[0],ati_data[1],ati_data[2],ati_data[3],ati_data[4],ati_data[5]);
- // Print converted data
+ // Print converted LTC data
pc.printf("%.2f,%.2f,%.2f,%.2f,%.2f,%.2f, ", ft_data[0],ft_data[1],ft_data[2],ft_data[3],ft_data[4],ft_data[5]);
// Sample from force sensor