Xin Zhang / azure-iot-c-sdk-f767zi

Dependents:   samplemqtt

Revision:
0:f7f1f0d76dd6
diff -r 000000000000 -r f7f1f0d76dd6 iothub_client/inc/iothub_client_options.h
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/iothub_client/inc/iothub_client_options.h	Thu Aug 23 06:52:14 2018 +0000
@@ -0,0 +1,83 @@
+// Copyright (c) Microsoft. All rights reserved.
+// Licensed under the MIT license. See LICENSE file in the project root for full license information.
+
+#ifndef IOTHUB_CLIENT_OPTIONS_H
+#define IOTHUB_CLIENT_OPTIONS_H
+
+#include "azure_c_shared_utility/const_defines.h"
+
+#ifdef __cplusplus
+extern "C"
+{
+#endif
+
+    typedef struct IOTHUB_PROXY_OPTIONS_TAG
+    {
+        const char* host_address;
+        const char* username;
+        const char* password;
+    } IOTHUB_PROXY_OPTIONS;
+
+    static STATIC_VAR_UNUSED const char* OPTION_LOG_TRACE = "logtrace";
+    static STATIC_VAR_UNUSED const char* OPTION_X509_CERT = "x509certificate";
+    static STATIC_VAR_UNUSED const char* OPTION_X509_PRIVATE_KEY = "x509privatekey";
+    static STATIC_VAR_UNUSED const char* OPTION_KEEP_ALIVE = "keepalive";
+    static STATIC_VAR_UNUSED const char* OPTION_CONNECTION_TIMEOUT = "connect_timeout";
+
+    static STATIC_VAR_UNUSED const char* OPTION_PROXY_HOST = "proxy_address";
+    static STATIC_VAR_UNUSED const char* OPTION_PROXY_USERNAME = "proxy_username";
+    static STATIC_VAR_UNUSED const char* OPTION_PROXY_PASSWORD = "proxy_password";
+
+    static STATIC_VAR_UNUSED const char* OPTION_SAS_TOKEN_LIFETIME = "sas_token_lifetime";
+    static STATIC_VAR_UNUSED const char* OPTION_SAS_TOKEN_REFRESH_TIME = "sas_token_refresh_time";
+    static STATIC_VAR_UNUSED const char* OPTION_CBS_REQUEST_TIMEOUT = "cbs_request_timeout";
+
+    static STATIC_VAR_UNUSED const char* OPTION_MIN_POLLING_TIME = "MinimumPollingTime";
+    static STATIC_VAR_UNUSED const char* OPTION_BATCHING = "Batching";
+
+	/* DEPRECATED:: OPTION_MESSAGE_TIMEOUT is DEPRECATED! Use OPTION_SERVICE_SIDE_KEEP_ALIVE_FREQ_SECS for AMQP; MQTT has no option available. OPTION_MESSAGE_TIMEOUT legacy variable will be kept for back-compat.  */
+    static STATIC_VAR_UNUSED const char* OPTION_MESSAGE_TIMEOUT = "messageTimeout";
+    static STATIC_VAR_UNUSED const char* OPTION_BLOB_UPLOAD_TIMEOUT_SECS = "blob_upload_timeout_secs";
+    static STATIC_VAR_UNUSED const char* OPTION_PRODUCT_INFO = "product_info";
+
+    /*
+    * @brief    Turns on automatic URL encoding of message properties + system properties. Only valid for use with MQTT Transport
+    */
+    static STATIC_VAR_UNUSED const char* OPTION_AUTO_URL_ENCODE_DECODE = "auto_url_encode_decode";
+
+    /*
+    * @brief Informs the service of what is the maximum period the client will wait for a keep-alive message from the service.
+    *        The service must send keep-alives before this timeout is reached, otherwise the client will trigger its re-connection logic.
+    *        Setting this option to a low value results in more aggressive/responsive re-connection by the client.
+    *        The default value for this option is 240 seconds, and the minimum allowed is usually 5 seconds.
+    *        To virtually disable the keep-alives from the service (and consequently the keep-alive timeout control on the client-side), set this option to a high value (e.g., UINT_MAX).
+    */
+    static STATIC_VAR_UNUSED const char* OPTION_SERVICE_SIDE_KEEP_ALIVE_FREQ_SECS = "svc2cl_keep_alive_timeout_secs";
+
+    /* DEPRECATED:: OPTION_C2D_KEEP_ALIVE_FREQ_SECS is DEPRECATED!  Use OPTION_SERVICE_SIDE_KEEP_ALIVE_FREQ_SECS, but OPTION_C2D_KEEP_ALIVE_FREQ_SECS legacy variable kept for back-compat.  */ 
+    static STATIC_VAR_UNUSED const char* OPTION_C2D_KEEP_ALIVE_FREQ_SECS = "c2d_keep_alive_freq_secs"; 
+
+    /*
+    * @brief Ratio to be used for client side pings in AMQP protocol.
+    *        The client must use this ratio to send keep-alives before service side remote idle timeout is reached, otherwise the service will disconnect the client.
+    *        The default value for this option is 1/2 of the remote idle value sent by the service. 
+    *        For AMQP remote idle set to 4 minutes, default client ping will be 2 minutes. For AMQP remote idle set to 25 minutes configured via per Hub basis, the default ping will be 12.5 minutes.
+    */
+    static STATIC_VAR_UNUSED const char* OPTION_REMOTE_IDLE_TIMEOUT_RATIO = "cl2svc_keep_alive_send_ratio"; 
+
+	/*
+	* @brief This option should be used instead of OPTION_MESSAGE_TIMEOUT if using AMQP protocol.
+	*        It defines the maximum ammount of time, in seconds, the client will wait for a telemetry message to complete sending before returning it with a IOTHUB_CLIENT_CONFIRMATION_MESSAGE_TIMEOUT error.
+	*        The default value 5 (five) minutes.
+	*        This option is applicable only to AMQP protocol.
+	*/
+	static STATIC_VAR_UNUSED const char* OPTION_EVENT_SEND_TIMEOUT_SECS = "event_send_timeout_secs";
+
+    //diagnostic sampling percentage value, [0-100]
+    static STATIC_VAR_UNUSED const char* OPTION_DIAGNOSTIC_SAMPLING_PERCENTAGE = "diag_sampling_percentage";
+
+#ifdef __cplusplus
+}
+#endif
+
+#endif /* IOTHUB_CLIENT_OPTIONS_H */