Vybhav Kadaba
/
EV-PRO-MW1001_MWARE_2042
Adding mbed FW version and release notes
Diff: i2c0_sensirionSHT3X_config.c
- Revision:
- 25:b278a215cf3b
- Parent:
- 19:09d58952b65d
- Child:
- 32:52445bef314d
--- a/i2c0_sensirionSHT3X_config.c Fri Sep 27 05:23:04 2019 +0000 +++ b/i2c0_sensirionSHT3X_config.c Tue Oct 01 05:11:56 2019 +0000 @@ -51,20 +51,28 @@ }, .measurement = { .operatingMode = ADMW1001_OPERATING_MODE_CONTINUOUS, - .dataReadyMode = ADMW1001_DATAREADY_PER_CYCLE, + .dataReadyMode = ADMW1001_DATAREADY_PER_CYCLE, // FIX: Temporarily all values from json are hardcoded to this one in the Contracts.FileGenerator - > file translations!! + .cycleInterval = 0, + }, + .diagnostics = { + .disableGlobalDiag = true, + .disableMeasurementDiag = true, + .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, }, .channels = { [ADMW1001_CH_ID_DIG_I2C_0] = { .enableChannel = true, +// .gain = ADMW1001_ADC_GAIN_1X, .disablePublishing = false, .compensationChannel = ADMW1001_CH_ID_NONE, - .measurementsPerCycle = 10, - .extraSettlingTime = 15000, + .measurementUnit = ADMW1001_MEASUREMENT_UNIT_UNSPECIFIED, + .measurementsPerCycle = 1, + .extraSettlingTime = 99500.0014663674, .i2cChannelConfig = { .sensor = ADMW1001_I2C_SENSOR_HUMIDITY_B, - .deviceAddress = 0x44, + .dataFormat.coding = ADMW1001_DIGITAL_SENSOR_DATA_CODING_UNIPOLAR, }, - }, + } }, }, };