ADMW1001_DIAGNOSTICS_CONFIG Struct Reference
[ADMW1001 Host Library API]
#include <admw1001_config.h>
Data Fields | |
| bool | disableGlobalDiag |
| bool | disableMeasurementDiag |
| bool | disableCriticalTempAbort |
| uint8_t | osdFrequency |
Detailed Description
ADMW1001 Diagnostics configuration details
Definition at line 841 of file admw1001_config.h.
Field Documentation
Option to disable abort of measurement cycle if the operating temperature of the ADMW1001 has exceeded critical limits
Definition at line 855 of file admw1001_config.h.
| bool disableGlobalDiag |
Option to disable the following diagnostic checks on the ADC:
- Reference Detection errors
- Input under-/over-voltage errors
- Calibration, Conversion and Saturation errors
Definition at line 844 of file admw1001_config.h.
Option to disable additional checks per measurement channel:
- High/low threshold limit violation
Definition at line 850 of file admw1001_config.h.
| uint8_t osdFrequency |
Option to enable Open-Circuit Detection at a selected cycle interval
Definition at line 860 of file admw1001_config.h.
Generated on Thu Jul 14 2022 16:18:24 by