port of the azure client sample mqtt for the NUCLEO STM32F746ZG platform

Dependencies:   F7_Ethernet NTPClient azure_c_shared_utility azure_umqtt_c iothub_client iothub_mqtt_transport mbed-rtos mbed wolfSSL

Fork of iothub_client_sample_mqtt by Azure IoT

Committer:
Azure.IoT Build
Date:
Fri Mar 25 16:10:00 2016 -0700
Revision:
2:65c172c36cf5
Child:
6:02304619a9fa
1.0.3

Who changed what in which revision?

UserRevisionLine numberNew contents of line
Azure.IoT Build 2:65c172c36cf5 1 // Copyright (c) Microsoft. All rights reserved.
Azure.IoT Build 2:65c172c36cf5 2 // Licensed under the MIT license. See LICENSE file in the project root for full license information.
Azure.IoT Build 2:65c172c36cf5 3
Azure.IoT Build 2:65c172c36cf5 4 #include <stdio.h>
Azure.IoT Build 2:65c172c36cf5 5 #include <stdlib.h>
Azure.IoT Build 2:65c172c36cf5 6
Azure.IoT Build 2:65c172c36cf5 7 #include "iothub_client.h"
Azure.IoT Build 2:65c172c36cf5 8 #include "iothub_message.h"
Azure.IoT Build 2:65c172c36cf5 9 #include "threadapi.h"
Azure.IoT Build 2:65c172c36cf5 10 #include "crt_abstractions.h"
Azure.IoT Build 2:65c172c36cf5 11 #include "iothubtransportmqtt.h"
Azure.IoT Build 2:65c172c36cf5 12 #include "platform.h"
Azure.IoT Build 2:65c172c36cf5 13
Azure.IoT Build 2:65c172c36cf5 14 #ifdef MBED_BUILD_TIMESTAMP
Azure.IoT Build 2:65c172c36cf5 15 #include "certs.h"
Azure.IoT Build 2:65c172c36cf5 16 #endif // MBED_BUILD_TIMESTAMP
Azure.IoT Build 2:65c172c36cf5 17
Azure.IoT Build 2:65c172c36cf5 18
Azure.IoT Build 2:65c172c36cf5 19 /*String containing Hostname, Device Id & Device Key in the format: */
Azure.IoT Build 2:65c172c36cf5 20 /* "HostName=<host_name>;DeviceId=<device_id>;SharedAccessKey=<device_key>" */
Azure.IoT Build 2:65c172c36cf5 21 static const char* connectionString = "[device connection string]";
Azure.IoT Build 2:65c172c36cf5 22
Azure.IoT Build 2:65c172c36cf5 23 static int callbackCounter;
Azure.IoT Build 2:65c172c36cf5 24 static char msgText[1024];
Azure.IoT Build 2:65c172c36cf5 25 #define MESSAGE_COUNT 5
Azure.IoT Build 2:65c172c36cf5 26 static bool continueRunning;
Azure.IoT Build 2:65c172c36cf5 27
Azure.IoT Build 2:65c172c36cf5 28 DEFINE_ENUM_STRINGS(IOTHUB_CLIENT_CONFIRMATION_RESULT, IOTHUB_CLIENT_CONFIRMATION_RESULT_VALUES);
Azure.IoT Build 2:65c172c36cf5 29
Azure.IoT Build 2:65c172c36cf5 30 typedef struct EVENT_INSTANCE_TAG
Azure.IoT Build 2:65c172c36cf5 31 {
Azure.IoT Build 2:65c172c36cf5 32 IOTHUB_MESSAGE_HANDLE messageHandle;
Azure.IoT Build 2:65c172c36cf5 33 int messageTrackingId; // For tracking the messages within the user callback.
Azure.IoT Build 2:65c172c36cf5 34 } EVENT_INSTANCE;
Azure.IoT Build 2:65c172c36cf5 35
Azure.IoT Build 2:65c172c36cf5 36
Azure.IoT Build 2:65c172c36cf5 37 static IOTHUBMESSAGE_DISPOSITION_RESULT ReceiveMessageCallback(IOTHUB_MESSAGE_HANDLE message, void* userContextCallback)
Azure.IoT Build 2:65c172c36cf5 38 {
Azure.IoT Build 2:65c172c36cf5 39 int* counter = (int*)userContextCallback;
Azure.IoT Build 2:65c172c36cf5 40 const char* buffer;
Azure.IoT Build 2:65c172c36cf5 41 size_t size;
Azure.IoT Build 2:65c172c36cf5 42 if (IoTHubMessage_GetByteArray(message, (const unsigned char**)&buffer, &size) != IOTHUB_MESSAGE_OK)
Azure.IoT Build 2:65c172c36cf5 43 {
Azure.IoT Build 2:65c172c36cf5 44 (void)printf("unable to retrieve the message data\r\n");
Azure.IoT Build 2:65c172c36cf5 45 }
Azure.IoT Build 2:65c172c36cf5 46 else
Azure.IoT Build 2:65c172c36cf5 47 {
Azure.IoT Build 2:65c172c36cf5 48 (void)printf("Received Message [%d] with Data: <<<%.*s>>> & Size=%d\r\n", *counter, (int)size, buffer, (int)size);
Azure.IoT Build 2:65c172c36cf5 49 // If we receive the work 'quit' then we stop running
Azure.IoT Build 2:65c172c36cf5 50 if (memcmp(buffer, "quit", size) == 0)
Azure.IoT Build 2:65c172c36cf5 51 {
Azure.IoT Build 2:65c172c36cf5 52 continueRunning = false;
Azure.IoT Build 2:65c172c36cf5 53 }
Azure.IoT Build 2:65c172c36cf5 54 }
Azure.IoT Build 2:65c172c36cf5 55
Azure.IoT Build 2:65c172c36cf5 56 // Retrieve properties from the message
Azure.IoT Build 2:65c172c36cf5 57 MAP_HANDLE mapProperties = IoTHubMessage_Properties(message);
Azure.IoT Build 2:65c172c36cf5 58 if (mapProperties != NULL)
Azure.IoT Build 2:65c172c36cf5 59 {
Azure.IoT Build 2:65c172c36cf5 60 const char*const* keys;
Azure.IoT Build 2:65c172c36cf5 61 const char*const* values;
Azure.IoT Build 2:65c172c36cf5 62 size_t propertyCount = 0;
Azure.IoT Build 2:65c172c36cf5 63 if (Map_GetInternals(mapProperties, &keys, &values, &propertyCount) == MAP_OK)
Azure.IoT Build 2:65c172c36cf5 64 {
Azure.IoT Build 2:65c172c36cf5 65 if (propertyCount > 0)
Azure.IoT Build 2:65c172c36cf5 66 {
Azure.IoT Build 2:65c172c36cf5 67 (void)printf("ERROR: message incorrectly contains properties!\r\n");
Azure.IoT Build 2:65c172c36cf5 68 for (size_t index = 0; index < propertyCount; index++)
Azure.IoT Build 2:65c172c36cf5 69 {
Azure.IoT Build 2:65c172c36cf5 70 (void)printf("\tKey: %s Value: %s\r\n", keys[index], values[index]);
Azure.IoT Build 2:65c172c36cf5 71 }
Azure.IoT Build 2:65c172c36cf5 72 (void)printf("\r\n");
Azure.IoT Build 2:65c172c36cf5 73 }
Azure.IoT Build 2:65c172c36cf5 74 }
Azure.IoT Build 2:65c172c36cf5 75 }
Azure.IoT Build 2:65c172c36cf5 76
Azure.IoT Build 2:65c172c36cf5 77 /* Some device specific action code goes here... */
Azure.IoT Build 2:65c172c36cf5 78 (*counter)++;
Azure.IoT Build 2:65c172c36cf5 79 return IOTHUBMESSAGE_ACCEPTED;
Azure.IoT Build 2:65c172c36cf5 80 }
Azure.IoT Build 2:65c172c36cf5 81
Azure.IoT Build 2:65c172c36cf5 82 static void SendConfirmationCallback(IOTHUB_CLIENT_CONFIRMATION_RESULT result, void* userContextCallback)
Azure.IoT Build 2:65c172c36cf5 83 {
Azure.IoT Build 2:65c172c36cf5 84 EVENT_INSTANCE* eventInstance = (EVENT_INSTANCE*)userContextCallback;
Azure.IoT Build 2:65c172c36cf5 85 (void)printf("Confirmation[%d] received for message tracking id = %d with result = %s\r\n", callbackCounter, eventInstance->messageTrackingId, ENUM_TO_STRING(IOTHUB_CLIENT_CONFIRMATION_RESULT, result));
Azure.IoT Build 2:65c172c36cf5 86 /* Some device specific action code goes here... */
Azure.IoT Build 2:65c172c36cf5 87 callbackCounter++;
Azure.IoT Build 2:65c172c36cf5 88 IoTHubMessage_Destroy(eventInstance->messageHandle);
Azure.IoT Build 2:65c172c36cf5 89 }
Azure.IoT Build 2:65c172c36cf5 90
Azure.IoT Build 2:65c172c36cf5 91 void iothub_client_sample_mqtt_run(void)
Azure.IoT Build 2:65c172c36cf5 92 {
Azure.IoT Build 2:65c172c36cf5 93 IOTHUB_CLIENT_LL_HANDLE iotHubClientHandle;
Azure.IoT Build 2:65c172c36cf5 94
Azure.IoT Build 2:65c172c36cf5 95 EVENT_INSTANCE messages[MESSAGE_COUNT];
Azure.IoT Build 2:65c172c36cf5 96
Azure.IoT Build 2:65c172c36cf5 97 continueRunning = true;
Azure.IoT Build 2:65c172c36cf5 98 srand((unsigned int)time(NULL));
Azure.IoT Build 2:65c172c36cf5 99 double avgWindSpeed = 10.0;
Azure.IoT Build 2:65c172c36cf5 100
Azure.IoT Build 2:65c172c36cf5 101 callbackCounter = 0;
Azure.IoT Build 2:65c172c36cf5 102 int receiveContext = 0;
Azure.IoT Build 2:65c172c36cf5 103
Azure.IoT Build 2:65c172c36cf5 104 if (platform_init() != 0)
Azure.IoT Build 2:65c172c36cf5 105 {
Azure.IoT Build 2:65c172c36cf5 106 (void)printf("Failed to initialize the platform.\r\n");
Azure.IoT Build 2:65c172c36cf5 107 }
Azure.IoT Build 2:65c172c36cf5 108 else
Azure.IoT Build 2:65c172c36cf5 109 {
Azure.IoT Build 2:65c172c36cf5 110 (void)printf("Starting the IoTHub client sample MQTT...\r\n");
Azure.IoT Build 2:65c172c36cf5 111
Azure.IoT Build 2:65c172c36cf5 112 if ((iotHubClientHandle = IoTHubClient_LL_CreateFromConnectionString(connectionString, MQTT_Protocol)) == NULL)
Azure.IoT Build 2:65c172c36cf5 113 {
Azure.IoT Build 2:65c172c36cf5 114 (void)printf("ERROR: iotHubClientHandle is NULL!\r\n");
Azure.IoT Build 2:65c172c36cf5 115 }
Azure.IoT Build 2:65c172c36cf5 116 else
Azure.IoT Build 2:65c172c36cf5 117 {
Azure.IoT Build 2:65c172c36cf5 118 bool traceOn = true;
Azure.IoT Build 2:65c172c36cf5 119 IoTHubClient_LL_SetOption(iotHubClientHandle, "logtrace", &traceOn);
Azure.IoT Build 2:65c172c36cf5 120
Azure.IoT Build 2:65c172c36cf5 121 #ifdef MBED_BUILD_TIMESTAMP
Azure.IoT Build 2:65c172c36cf5 122 // For mbed add the certificate information
Azure.IoT Build 2:65c172c36cf5 123 if (IoTHubClient_LL_SetOption(iotHubClientHandle, "TrustedCerts", certificates) != IOTHUB_CLIENT_OK)
Azure.IoT Build 2:65c172c36cf5 124 {
Azure.IoT Build 2:65c172c36cf5 125 printf("failure to set option \"TrustedCerts\"\r\n");
Azure.IoT Build 2:65c172c36cf5 126 }
Azure.IoT Build 2:65c172c36cf5 127 #endif // MBED_BUILD_TIMESTAMP
Azure.IoT Build 2:65c172c36cf5 128
Azure.IoT Build 2:65c172c36cf5 129 /* Setting Message call back, so we can receive Commands. */
Azure.IoT Build 2:65c172c36cf5 130 if (IoTHubClient_LL_SetMessageCallback(iotHubClientHandle, ReceiveMessageCallback, &receiveContext) != IOTHUB_CLIENT_OK)
Azure.IoT Build 2:65c172c36cf5 131 {
Azure.IoT Build 2:65c172c36cf5 132 (void)printf("ERROR: IoTHubClient_LL_SetMessageCallback..........FAILED!\r\n");
Azure.IoT Build 2:65c172c36cf5 133 }
Azure.IoT Build 2:65c172c36cf5 134 else
Azure.IoT Build 2:65c172c36cf5 135 {
Azure.IoT Build 2:65c172c36cf5 136 (void)printf("IoTHubClient_LL_SetMessageCallback...successful.\r\n");
Azure.IoT Build 2:65c172c36cf5 137
Azure.IoT Build 2:65c172c36cf5 138 /* Now that we are ready to receive commands, let's send some messages */
Azure.IoT Build 2:65c172c36cf5 139 for (size_t i = 0; i < MESSAGE_COUNT; i++)
Azure.IoT Build 2:65c172c36cf5 140 {
Azure.IoT Build 2:65c172c36cf5 141 sprintf_s(msgText, sizeof(msgText), "{\"deviceId\":\"myFirstDevice\",\"windSpeed\":%.2f}", avgWindSpeed + (rand() % 4 + 2));
Azure.IoT Build 2:65c172c36cf5 142 if ((messages[i].messageHandle = IoTHubMessage_CreateFromByteArray((const unsigned char*)msgText, strlen(msgText))) == NULL)
Azure.IoT Build 2:65c172c36cf5 143 {
Azure.IoT Build 2:65c172c36cf5 144 (void)printf("ERROR: iotHubMessageHandle is NULL!\r\n");
Azure.IoT Build 2:65c172c36cf5 145 }
Azure.IoT Build 2:65c172c36cf5 146 else
Azure.IoT Build 2:65c172c36cf5 147 {
Azure.IoT Build 2:65c172c36cf5 148 messages[i].messageTrackingId = i;
Azure.IoT Build 2:65c172c36cf5 149
Azure.IoT Build 2:65c172c36cf5 150 if (IoTHubClient_LL_SendEventAsync(iotHubClientHandle, messages[i].messageHandle, SendConfirmationCallback, &messages[i]) != IOTHUB_CLIENT_OK)
Azure.IoT Build 2:65c172c36cf5 151 {
Azure.IoT Build 2:65c172c36cf5 152 (void)printf("ERROR: IoTHubClient_LL_SendEventAsync..........FAILED!\r\n");
Azure.IoT Build 2:65c172c36cf5 153 }
Azure.IoT Build 2:65c172c36cf5 154 else
Azure.IoT Build 2:65c172c36cf5 155 {
Azure.IoT Build 2:65c172c36cf5 156 (void)printf("IoTHubClient_LL_SendEventAsync accepted message [%d] for transmission to IoT Hub.\r\n", (int)i);
Azure.IoT Build 2:65c172c36cf5 157 }
Azure.IoT Build 2:65c172c36cf5 158
Azure.IoT Build 2:65c172c36cf5 159 }
Azure.IoT Build 2:65c172c36cf5 160 }
Azure.IoT Build 2:65c172c36cf5 161 }
Azure.IoT Build 2:65c172c36cf5 162
Azure.IoT Build 2:65c172c36cf5 163 /* Wait for Commands. */
Azure.IoT Build 2:65c172c36cf5 164 while (continueRunning)
Azure.IoT Build 2:65c172c36cf5 165 {
Azure.IoT Build 2:65c172c36cf5 166 IoTHubClient_LL_DoWork(iotHubClientHandle);
Azure.IoT Build 2:65c172c36cf5 167 ThreadAPI_Sleep(1);
Azure.IoT Build 2:65c172c36cf5 168 }
Azure.IoT Build 2:65c172c36cf5 169 IoTHubClient_LL_Destroy(iotHubClientHandle);
Azure.IoT Build 2:65c172c36cf5 170 }
Azure.IoT Build 2:65c172c36cf5 171 platform_deinit();
Azure.IoT Build 2:65c172c36cf5 172 }
Azure.IoT Build 2:65c172c36cf5 173 }