Added integration of analog channels, introduced three new setpoints (Pb_1, Pb_2, Tp) for automatic compressor operation.

Dependencies:   _24LCXXX

Committer:
Aleksk
Date:
Thu Jun 04 22:55:40 2020 +0000
Revision:
5:bb595cde0c82
Parent:
0:f2aaa8c6decf
The flag of the Stop button is accepted - closing of 4 valves,;   and the flag of the compressor buttons is a command for discrete output PB_10. The num_chan setting is switching the channel number for the feedback of the controller, written in EEPROM