ADI_SENSE_1000_DIGITAL_CALIBRATION_COMMAND Struct Reference
[ADSNS1000 Host Library API]
#include <adi_sense_1000_config.h>
Data Fields | |
| uint32_t | calibrationParam |
| bool_t | enableCalibrationParam |
Detailed Description
ADSNS1000 digital sensor calibration param
- Note:
- applicable only to digital sensor channels
Definition at line 655 of file adi_sense_1000_config.h.
Field Documentation
| uint32_t calibrationParam |
Independently established environmental variable used during calibration of a digital sensor. Used only if the sensor supports calibration and expects an environmental parameter
Definition at line 657 of file adi_sense_1000_config.h.
| bool_t enableCalibrationParam |
Allow Calibration_Parameter to be used during calibration of any digital sensor
Definition at line 662 of file adi_sense_1000_config.h.