-ADI Sense 1000 Overview
-=======================
-
-[TOC]
-
-ADI Sense 1000
---------------
-
-# Overview {#overview}
-The ADI Sense 1000 is a first-generation ADI Sense measurement processor which
-combines high-precision analog sensor inputs, SPI/I2C digital I/O interfaces
-and integrated DSP algorithms which transform the raw sensor input data into
-measurement values expressed in standard units ready for application use.
-
-The ADI Sense 1000 processor is designed to run as a slave device, connected
-to and controlled by a separate host application processor.
-
-The ADI Sense Host Application library currently includes support for the
-ADI Sense 1000 processor module, used in conjuction with the ST Nucleo F411RE
-host application processor running Mbed OS.  Support for additional ADI Sense
-modules and host application processor platforms will be added in the future.
-
-# Interfaces {#interfaces}
-## Host Communication Interfaces {#interfaces_hostcommunication}
-The interfaces in this section enable the connectivity with the host application
-processor which is responsible for configuration and control of the ADI Sense
-1000 device.  Platform-specific host connection parameters may be specified via
-the [ADI_SENSE_CONNECTION](@ref ADI_SENSE_CONNECTION) structure on the
-[ADI Sense API](@ref ADI_Sense_Api) and low-level connectivity is accessed
-via the [ADI Sense Host Portability Layer](@ref ADI_Sense_Host).
-
-* SPI
-  + Standard 4-wire SPI interface (SCLK, MOSI, MISO, SS)
-  + Mode 0 (CPOL=0, CPHA=0)
-  + SCLK speeds up to 1.6MHz
-* Signals
-  + ERROR
-    - active-high digital output
-    - signals an unrecoverable error condition to the host processor
-  + ALERT
-    - active-high digital output
-    - signals a warning/alert condition to the host processor
-  + DATAREADY
-    - active-high digital output
-    - signals a data ready condition to the host processor
-  + RESET
-    - active-low digital input
-    - pulse low for at least 4 microseconds to trigger a hardware reset of the module
-
-## Sensor Interfaces {#interfaces_sensor}
-The following is an overview of the sensors interfaces available on the ADI Sense 1000
-module.  For latest information on the sensors currently supported by this library,
-please refer to the [ADI Sense 1000 API](@ref ADI_Sense_1000_Api)
-
-* Analog Sensor Interfaces
-  + CJC 1-2
-    - Intended for connecting 2-wire reference temperature sensors
-    - Analog sensor types currently supported:
-      - 2-wire PT100 RTD
-      - 2-wire PT1000 RTD
-  + SENSOR 0-3
-    - Intended for connecting a wide variety of precision analog sensors
-    - Analog sensor types currently supported:
-      - 2/3/4-wire PT100 RTD temperature sensors
-      - 2/3/4-wire PT1000 RTD temperature sensors
-      - Type-T/K/J Thermocouple temperature sensors
-      - 4/6-wire bridge tranducer temperature/pressure sensors
-      - 10k NTC Thermistor temperature sensors
-  + I\_MEAS
-    - Intended for connecting 4-20mA analog current sensors
-  + V\_MEAS
-    - Intended for connecting 0-10V analog voltage sensors
-* Digital Sensor Interfaces
-  + SPI
-    - Intended for connecting support SPI digital sensors
-    - SPI digital sensor types currently supported:
-      - Honeywell TruStability HSC pressure sensors
-      - Analog Devices ADXL362 3-Axis MEMS accelerometer
-  + I2C
-    - Intended for connecting support SPI digital sensors
-    - SPI digital sensor types currently supported:
-      - Honeywell HumidIcon HIH9000 Series humidity sensors
-      - Sensirion SHT3x Series humidity sensors
-
-## Ancillary Interfaces {#interfaces_ancillary}
-* External Reference Inputs
-  + REF 1-2
-    - Optional external reference inputs, for use with analog sensors
-* Voltage Reference Outputs
-  + AVDD
-    - Analog voltage reference output (typically 3.3V)
-  + VDD
-    - Digital voltage reference output (typically 3.3V)
-