Important changes to repositories hosted on mbed.com
Mbed hosted mercurial repositories are deprecated and are due to be permanently deleted in July 2026.
To keep a copy of this software download the repository Zip archive or clone locally using Mercurial.
It is also possible to export all your personal repositories from the account settings page.
Fork of AX-12A by
AX12.h
- Committer:
- henryrawas
- Date:
- 2015-12-31
- Revision:
- 7:155ecc801119
- Parent:
- 6:a702043b1420
- Child:
- 8:b6979be5a0a7
File content as of revision 7:155ecc801119:
/* Copyright (c) 2012 Martin Smith, MIT License
*
* Permission is hereby granted, free of charge, to any person obtaining a copy of this software
* and associated documentation files (the "Software"), to deal in the Software without restriction,
* including without limitation the rights to use, copy, modify, merge, publish, distribute,
* sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is
* furnished to do so, subject to the following conditions:
*
* The above copyright notice and this permission notice shall be included in all copies or
* substantial portions of the Software.
*
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING
* BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM,
* DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
* OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
*/
#ifndef MBED_AX12_H
#define MBED_AX12_H
#include "mbed.h"
#include "DynamixelBus.h"
#include "RobotNode.h"
enum ControlTable
{
ctModelNumberLow = 0, // RD
ctModelNumberHigh = 1, // RD
ctFirmwareVersion = 2, // RD
ctID = 3, // RD/WR
ctBaudRate = 4, // RD/WR
ctReturnDelayTime = 5, // RD/WR
ctCWAngleLimitL = 6, // RD/WR
ctCWAngleLimitH = 7, // RD/WR
ctCCWAngleLimitL = 8, // RD/WR
ctCCWAngleLimitH = 9, // RD/WR
ctReserved1 = 10,
ctTemperatureLimit = 11, // RD/WR
ctVoltageLow = 12, // RD/WR
ctVoltageHigh = 13, // RD/WR
ctMaxTorqueL = 14, // RD/WR
ctMaxTorqueH = 15, // RD/WR
ctStatusReturnLevel = 16, // RD/WR
ctAlarmLED = 17, // RD/WR
ctAlarmShutdown = 18, // RD/WR
ctReserved2 = 19,
ctDownCalibrationL = 20, // RR
ctDownCalibrationH = 21, // RD
ctUpCalibrationL = 22, // RD
ctUpCalibrationH = 23, // RD
ctTorqueEnable = 24, // RD/WR
ctLED = 25, // RD/WR
ctCWComplianceMargin = 26, // RD/WR
ctCCWComplianceMargin = 27, // RD/WR
ctCWComplianceSlope = 28, // RD/WR
ctCCWComplianceSlope = 29, // RD/WR
ctGoalPositionL = 30, // RD/WR
ctGoalPositionH = 31, // RD/WR
ctMovingSpeedL = 32, // RD/WR
ctMovingSpeedH = 33, // RD/WR
ctTorqueLimitL = 34, // RD/WR
ctTorqueLimitH = 35, // RD/WR
ctPresentPositionL = 36, // RD
ctPresentPositionH = 37, // RD
ctPresentSpeedL = 38, // RD
ctPresentSpeedH = 39, // RD
ctPresentLoadL = 40, // RD
ctPresentLoadH = 41, // RD
ctPresentVoltage = 42, // RD
ctPresentTemperature = 43, // RD
ctRegisteredInst = 44, // RD/WR
ctReserved3 = 45,
ctMoving = 46, // RD
ctLock = 47, // RD/WR
ctPunchL = 48, // RD/WR
ctPunchH = 49 // RD/WR
};
class AX12 : public RobotNode
{
public:
AX12(DynamixelBus* pbus, ServoId = 1);
// sets the servo ID
StatusCode SetServoId(char newId);
// returns the status of the servo (connected/not connected + errors)
StatusCode Ping();
// Sets the goal position of the servo in degrees
StatusCode SetGoal(float degrees);
// determines if the servo is moving
bool IsMoving(void);
// gets the position of the servo in degrees
float GetPosition();
// gets the internal temperature of the servo
int GetTemperature(void);
// gets the servo power supply voltage
float GetSupplyVoltage(void);
// gets the servo load
float GetLoad(void);
// enables/disables holding torque
StatusCode TorqueEnable( bool );
// check if measure available
virtual bool HasMeasure(int measureId);
// get normalized measure value
virtual float GetMeasure(int measureId);
// get normalized measure value
virtual float GetLastMeasure(int measureId);
// do action
virtual bool DoAction(int actionId, float actionValue);
// check if has action
virtual bool HasAction(int actionId);
// get last error
virtual int GetLastError();
// get node type
virtual NodePartType GetNodeType();
private :
ServoId _ID;
DynamixelBus* _pbus;
// last read temperature
int _LastTemperature;
// last read position
float _LastPosition;
// last read voltage
float _LastVoltage;
// last read load
float _LastLoad;
unsigned char _LastError;
};
#endif