Important changes to repositories hosted on mbed.com
Mbed hosted mercurial repositories are deprecated and are due to be permanently deleted in July 2026.
To keep a copy of this software download the repository Zip archive or clone locally using Mercurial.
It is also possible to export all your personal repositories from the account settings page.
Dependencies: mbed
Diff: main.cpp
- Revision:
- 1:55c36e464885
- Parent:
- 0:bd554f9d9a54
- Child:
- 2:9bab1d673af9
--- a/main.cpp Tue Nov 15 10:04:05 2016 +0000
+++ b/main.cpp Fri Nov 18 15:53:34 2016 +0000
@@ -1,11 +1,14 @@
#include "mbed.h"
+#define VREF 3300.0f /* Device power supply in mV */
+
+// Parameters for temperature sensor only
#define AMBIENT_TEMP 25.0f /* Ambient Temperature in °C */
#define VSENS_AT_AMBIENT_TEMP 760.0f /* VSENSE value in mV at ambient temperature */
#define AVG_SLOPE 25.0f /* Average slope in mV/°C multiplied by 10 */
-#define VREF 3300.0f /* Device power supply in mV */
-AnalogIn tempsensor(ADC_TEMP);
+//AnalogIn vbat(ADC_VBAT); // To measure VBat
+AnalogIn tempsensor(ADC_TEMP); // To measure Temperature sensot
DigitalOut led(LED1);
@@ -14,10 +17,20 @@
float meas_f;
float JTemp_f;
- printf("\nSTM32 Internal Temperature Sensor example\n");
+ printf("\nSTM32 Internal Channels example\n");
while(1) {
+ /*
+ Note 1: As VBAT voltage could be higher than VDDA, to ensure the correct operation of the ADC, the
+ VBAT pin is internally connected to a bridge divider by 4.
+ Note 2: On some devices the VBAT and temperature sensor are connected to the same ADC internal channel
+ Only one conversion, either temperature sensor or VBAT, must be selected at a time.
+ When both conversion are enabled simultaneously, only the VBAT conversion is
+ performed.
+ */
+ //printf("\nVBat = %.1f mV\n", vbat.read() * VREF * 4);
+
meas_f = tempsensor.read();
/* Compute the Junction Temperature value