This program simply connects to a HTS221 I2C device to read Temperature & Humidity, and a WNC Cellular Module both of which are on the Avnet WNC Shield.

Dependencies:   mbed FXOS8700CQ

/media/uploads/JMF/avnet_logo.gif

AT&T Shape Hackathon QuickStart Instructions

  • One area that has been problematic is setting the the MY_SERVER_URL. When you copy the URL from the flow, you must make sure that the MY_SERVER_URL is also set to the appropirate server. It can be either "run-east.att.io" or "run-west.att.io", so be sure to check this.

Useful Links

Adding Additional Sensors

The FLOW_DEVICE_NAME field must contain the name of the instance of the Virtual Starter kit in FLOW that you will be communicating with. Usually this will be "vstarterkit001", but if you have problems communicating you can verify that this is indeed correct. Note that this device will not be created until you click the “Initialize” input on the Virtual Device tab of the Starter Kit project in FLOW. At that point it becomes available in M2X and you can see it there, as the DEVICE SERIAL field under Devices as in the image below.

Sensors: When executing, the FRDM-K64F board will upload sensor measurements to AT&T’s Flow environment every 5 seconds, using the Cellular shield board. You can adjust how often you want to do this by editing the SENSOR_UPDATE_INTERVAL_MS value in the header file. Temperature and humidity: By default the board will report readings from the HTS221 temperature and humidity sensor. These two values are sent to the HTTP IN /climate port in FLOW with field names “temp” and “humidity”. Temperature is in degrees Fahrenheit and humidity is a %. This default assignment is: iSensorsToReport = TEMP_HUMIDITY_ONLY;

Accelerometer: If you want to expand and use the on-board motion sensor, you can also send 3-axis accelerometer information from the board as “accelX”, “accelY” and “accelZ”. This is useful if you want to know the stationary position of the board with regards to gravity, or whether it is in motion. These readings are in g’s. To send these values, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER;

PMOD Sensors: If you have a Silicon Labs sensor module that can plug into the PMOD connector on the Cellular shield, you will also be able to measure proximity, UV light, ambient visible and infrared light from the Si1145 sensor. This PMOD also has a temperature and humidity sensor, but in this case it is redundant. When enabled, the fields “proximity”, “light_uv”, “light_vis” and “light_ir” will also be sent. To enable all these sensors, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS;

Connecting up the PMOD sensors: Because the pinouts do not align, the SiLabs PMOD sensor board cannot be plugged into the J10 PMOD receptacle on the shield directly. The following wiring instructions must be used:

Signal=J10=(Shield) PMOD=Color in the image below
VCCPin 6Pin 6Red
GNDPin 5Pin 5Black
SDAPin4Pin 3Green
SCLPin3Pin 2Yellow

Link to AT&T M2X

M2X

Link to AT&T Flow

FLOW

Avnet WNC-Shield Information

Getting Started with the Avnet WNC-Shield & Hackathon software

  • This project uses Revision 119 of the MBED library because of I2C implementation differences with the tip (Revision 121)
  • This project uses Revision 4 of the FXOS8700CQ library for sensors

Easily modifiable parameters in source code

Inside the mbed “AvnetATT_shape_hackathon” project, the parameters that are needed to customize your board are in the config_me.h file.

  • FLOW parameters: This project assumes that you are using a fork of the “Starter Kit Base” project, which is a reference design that was created using AT&T’s FLOW (https://flow.att.com) that allows the creation of on-line virtualization and other IoT functionality. The default parameters in the config_me.h file are done for a specific instance of this project. When you fork the original project, you get your own instance and it will have its own base address. At the bottom of the FLOW environment, when you click on the “Endpoints” tab, you will see the URL information that is specific to your instance. Of note is the Base URL. In the example below (as in the default mbed project), the Base URL is: https://run-west.att.io/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow You have to take note of two parts of this address. The run-west.att.io part is the server URL, and you have to make sure the
  • MY_SERVER_URL field in config_me.h matches this. Then there is the rest of the base URL, in green above, that needs to be pasted into the FLOW_BASE_URL field.

There is also a FLOW_INPUT_NAME field. This should match the name of the HTTP IN port in the FLOW project that you want to send sensor data to. The default is "/climate", as in the FLOW image below.

/media/uploads/JMF/sf.png

Where is the binary I compiled

When the COMPILE button is pressed, it will compile your project and link it. The result is placed in the DOWNLOAD folder you use when downloading files from the internet. It will be called AvnetATT_shape_hackathon_K64F.bin.

Additional information on compiling/configuring

Comprehensive instructions can be found at: Quick Start Instructions

Revision:
23:d6ceeb6d85ed
Parent:
21:d0038d14ee7c
Child:
30:48b43538e98b
--- a/config_me.h	Wed Jul 13 18:34:56 2016 +0000
+++ b/config_me.h	Wed Jul 13 19:53:44 2016 +0000
@@ -4,24 +4,35 @@
 // User must set these for own context:
 
 // This is the server's base URL name.  Example "www.google.com"
+// Note that when you Fork a FLOW, it will typically assign  either
+// "run-east.att.io" or "run-west.att.io", so be sure to check this.
 static const char * MY_SERVER_URL       = "run-west.att.io";
 
-// These are FLOW variables that must be read from your own FLOW account and placed here:
+// These are FLOW fields from the Endpoints tab:
 #define FLOW_BASE_URL                   "/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow"
 #define FLOW_INPUT_NAME                 "/climate"
 
-// This in most cases should be left alone but is here if you want to talk a differnet protocol:
+// Unless you want to use a different protocol, this field should be left as is:
 #define FLOW_URL_TYPE                   " HTTP/1.1\r\nHost: "
 
-// This just needs to be a unique identifier 1 for each board that talks to each FLOW account. 
-// If you only have one board then you can just leave this alone but you have to use this
-// identifier in your FLOW setup for identification.
+// This identifier specifies with which FLOW device you are communicating. 
+// If you only have one devive there then you can just leave this as is.
+// Once your FLOW device has been initialized (Virtual Device Initialize clicked),
+// the Virtual Device will show up in M2X.  This is its "DEVICE SERIAL" field
 #define FLOW_DEVICE_NAME                "vstarterkit001"
 
-// These are for?
+// This constant defines how often sensors are read and sent up to FLOW
+#define SENSOR_UPDATE_INTERVAL_MS       5000; //5 seconds
+
+// Specify here how many sensor parameters you want reported to FLOW.
+// You can use only the temperature and humidity from the shield HTS221
+// or you can add the reading of the FXO8700CQ motion sensor on the FRDM-K64F board
+// or if you have a SiLabs PMOD plugged into the shield, you can add its proximity sensor,
+// UV light, visible ambient light and infrared ambient light readings
 #define TEMP_HUMIDITY_ONLY                      1
 #define TEMP_HUMIDITY_ACCELEROMETER             2
 #define TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS 3
+static int iSensorsToReport = TEMP_HUMIDITY_ONLY; //modify this to change your selection
 
 // This is the APN name for the cellular network, you will need to change this, check the instructions included with your SIM card kit:
 static const char * MY_APN_STR          = "m2m.com.attz";