This is a Testing library
Revision 0:ab240102b895, committed 2016-11-28
- Comitter:
- javiersing
- Date:
- Mon Nov 28 12:58:28 2016 +0000
- Commit message:
- This is a testing library
Changed in this revision
Decagon10HS.h | Show annotated file Show diff for this revision Revisions of this file |
diff -r 000000000000 -r ab240102b895 Decagon10HS.h --- /dev/null Thu Jan 01 00:00:00 1970 +0000 +++ b/Decagon10HS.h Mon Nov 28 12:58:28 2016 +0000 @@ -0,0 +1,9 @@ +float Moist10HS(AnalogIn moist) +{ + // SUBSTRATE CALIBRATION: You have to convert the voltage to VWC using soil or substrate specific calibration. Decagon has generic calibrations (check the 10HS manual at http://manuals.decagon.com/Manuals/13508_10HS_Web.pdf) or you can determine your own calibration. We used our own calibration for Fafard 1P (peat: perlite, Conrad Fafard, Inc., Agawam, MA) + float SubCalSlope = 1.1785; + float SubCalIntercept = -0.4938; + float value = moist.read(); // lee el puerto analogico y lo muestra de 0-1V + float VWC = value * (3.3) * SubCalSlope + SubCalIntercept; // Convert the analog reading (which goes from 0 - 1V) + return VWC; +} \ No newline at end of file