@@ -0,0 +1,497 @@
+// Plunger sensor implementation for rotary absolute encoders
+//
+// This implements the plunger interfaces for rotary absolute encoders.  A
+// rotary encoder measures the angle of a rotating shaft.  For plunger sensing,
+// we can convert the plunger's linear motion into angular motion using a 
+// mechanical linkage between the plunger rod and a rotating shaft positioned
+// at a fixed point, somewhere nearby, but off of the plunger's axis:
+//
+//    =X=======================|===   <- plunger, X = connector attachment point
+//      \
+//       \                            <- connector between plunger and shaft
+//        \
+//         *                          <- rotating shaft, at a fixed position
+//
+// As the plunger moves, the angle of the connector relative to the fixed
+// shaft position changes in a predictable way, so by measuring the rotational
+// position of the shaft at any given time, we can infer the plunger's
+// linear position.
+//
+// (Note that the mechanical diagram is simplified for ASCII art purposes.
+// What's not shown is that the distance between the rotating shaft and the
+// "X" connection point on the plunger varies as the plunger moves, so the
+// mechanical linkage requires some way to accommodate that changing length.
+// One way is to use a spring as the linkage; another is to use a rigid
+// connector with a sliding coupling at one or the other end.  We leave
+// these details up to the mechanical design; the software isn't affected
+// as long as the basic relationship between linear and angular motion as
+// shown in the diagram be achieved.)
+//
+//
+// Translating the angle to a linear position
+//
+// There are two complications to translating the angular reading back to
+// a linear plunger position.
+//
+// 1. We have to consider the sensor's zero point to be arbitrary.  That means
+// that the zero point could be somewhere within the plunger's travel range,
+// so readings might "wrap" - e.g., we might see a series of readings when
+// the plunger is moving in one direction like 4050, 4070, 4090, 14, 34 (note
+// how we've "wrapped" past the 4096 boundary).  
+//
+// To deal with this, we have to make a couple of assumptions:
+//
+//   - The park position is at about 1/6 of the overall travel range
+//   - The total angular travel range is less than one full revolution
+//
+// With those assumptions in hand, we can bias the raw readings to the
+// park position, and then take them modulo the raw scale.  That will
+// ensure that readings wrap properly, regardless of where the raw zero
+// point lies.
+//
+// 2. Going back to the original diagram, you can see that the angle doesn't
+// vary linearly with the plunger position.  It actually varies sinusoidally.
+// Let's use the vertical line between the plunger and the rotation point as
+// the zero-degree reference point.  To figure the plunger position, then,
+// we need to figure the difference between the raw angle reading and the
+// zero-degree point; call this theta.  Let L be the position of the plunger
+// relative to the vertical reference point, let D be the length of the 
+// vertical reference point line, and let H by the distance from the rotation 
+// point to the plunger connection point.  This is a right triangle with 
+// hypotenuse H and sides L and D.  D is a constant, because the rotation 
+// point never moves, and the plunger never moves vertically.  Thus we can
+// calculate D = H*cos(theta) and L = H*sin(theta).  D is a constant, so
+// we can figure H = D/cos(theta) hence L = D*sin(theta)/cos(theta) or
+// D*tan(theta).  If we wanted to know the true position in real-world
+// units, we'd have to know D, but only need arbitrary linear units, so
+// we can choose whatever value for D we find convenient: in particular,
+// a value that gives us the desired range and resolution for the final
+// result.
+//
+// Note that the tangent diverges at +/-90 degrees, but that's not a problem
+// for the mechanical setup we've described, as the motion is inherently
+// limited to stay within this range.
+//
+// There's still one big piece missing here: we somehow have to know where
+// that vertical zero point lies.  That's something we can only learn by
+// calibration.  Unfortunately, we don't have a good way to detect this
+// directly.  We *could* ask the user to look inside the cabinet and press
+// a button when the needle is straight up, but that seems too cumbersome.
+// What we'll do instead is provide some mechanical installation guidelines
+// about where the rotation point should be positioned, and then use the
+// full range to deduce the vertical position. 
+//
+// The full range we actually have after calibration consists of the park
+// position and the maximum retracted position.  We could in principle also
+// calibrate the maximum forward position, but that can't be read as reliably
+// as the other two, because the barrel spring makes it difficult for the 
+// user to be sure they've pushed it all the way forward.  Since we can 
+// extract the information we need from the park and max retract positions,
+// it's better to rely on those alone and not ask for information that the
+// user can't as easily provide.  Given these positions, AND the assumption
+// that the rotation point is at the midpoint of the plunger travel range,
+// we can do some rather grungy trig work to come up with a formula for the
+// angle between the park position and the vertical:
+//
+//    let C1 = 1 1/32" (distance from midpoint to park),
+//        C2 = 1 17/32" (distance from midpoint to max retract),
+//        C = C2/C1 = 1.48484849,
+//        alpha = angle from park to vertical,
+//        beta = angle from max retract to vertical
+//        theta = alpha + beta = angle from park to max retract, known from calibration,
+//        T = tan(theta);
+//
+//    then
+//        alpha = atan(sqrt(4*T*T*C + C^2 + 2*C + 1) - C - 1)/(2*T*C))
+//
+// Did I mention this was grungy?  At any rate, everything going into this
+// formula is either constant or known from the calibration, so we can 
+// pre-compute alpha and store it after each calibration operation.  And
+// knowing alpha, we can translate an angle reading from the sensor to an 
+// angle relative to the vertical, which we can plug into D*tan(angle) to
+// get a linear reading.  
+//
+// If you're wondering how we derived that ugly formula, read on.  Start
+// with the basic relationships D*tan(alpha) = C1 and D*tan(beta) = C2.
+// This lets us write tan(beta) in terms of tan(alpha) as 
+// C2/C1*tan(alpha) = C*tan(alpha).  We can combine this with an identity
+// for the tan of a sum of angles:
+//
+//    tan(alpha + beta) = (tan(alpha) + tan(beta))/(1 - tan(alpha)*tan(beta))
+//
+// to obtain:
+//
+//    tan(theta) = tan(alpha + beta) = (1 + C*tan(alpha))/(1 - C*tan^2(alpha))
+//
+// Everything here except alpha is known, so we now have a quadratic equation
+// for tan(alpha).  We can solve that by cranking through the normal algorithm
+// for solving a quadratic equation, arriving at the solution above.
+//
+//
+// Choosing an install position
+//
+// There are two competing factors in choosing the optimal "D".  On the one
+// hand, you'd like D to be as large as possible, to maximum linearity of the
+// tan function used to translate angle to linear position.  Higher linearity
+// gives us greater immunity to variations in the precise centering of the
+// rotation axis in the plunger travel range.  tan() is pretty linear within
+// about +/- 30 degrees.  On the other hand, you'd like D to be as small as 
+// possible so that we get the largest overall angle range.  Our sensor has 
+// a fixed angular resolution, so the more of the overall circle we use, the 
+// more sensor increments we have over the range, and thus the better
+// effective linear resolution.
+//
+// Let's do some calculations for various "D" values (vertical distance 
+// between rotation point and plunger rod).  For the effective DPI, we'll
+// 12-bit angular resolution, per the AEAT-6012 sensor.
+//
+//     D         theta(max)   eff dpi   theta(park)
+//  -----------------------------------------------
+//    1 17/32"    45 deg       341       34 deg
+//    2"          37 deg       280       27 deg
+//    2 21/32"    30 deg       228       21 deg
+//    3 1/4"      25 deg       190       17 deg
+//    4 3/16"     20 deg       152       14 deg
+//
+// I'd consider 50 dpi to be the minimum for acceptable performance, 100 dpi
+// to be excellent, and anything above 300 dpi to be diminishing returns.  So
+// for a 12-bit sensor, 2" looks like the sweet spot.  It doesn't take us far
+// outside of the +/-30 deg zone of tan() linearity, and it achieves almost 
+// 300 dpi of effective linear resolution.  I'd stop there are not try to
+// push the angular resolution higher with a shorter D; with the 45 deg
+// theta(max) at D = 1-17/32", we'd get a lovely DPI level of 341, but at
+// the cost of getting pretty non-linear around the ends of the plunger
+// travel.  Our math corrects for the non-linearity, but the more of that
+// correction we need, the more sensitive the whole contraption becomes to
+// getting the sensor positioning exactly right.  The closer we can stay to
+// the linear approximation, the more tolerant we are of inexact sensor
+// positioning.
+//
+//
+// Supported sensors
+//
+//  * AEAT-6012-A06.  This is a magnetic absolute encoder with 12-bit
+//    resolution.  It linearly encodes one full (360 degree) rotation in 
+//    4096 increments, so each increment represents 360/4096 = .088 degrees.
+//
+// The base class doesn't actually care much about the sensor type; all it
+// needs from the sensor is an angle reading represented on an arbitrary 
+// linear scale.  ("Linear" in the angle, so that one increment represents
+// a fixed number of degrees of arc.  The full scale can represent one full
+// turn but doesn't have to, as long as the scale is linear over the range
+// covered.)  To add new sensor types, you just need to add the code to
+// interface to the physical sensor and return its reading on an arbitrary
+// linear scale.
+
+#ifndef _ROTARYSENSOR_H_
+#define _ROTARYSENSOR_H_
+
+#include "FastInterruptIn.h"
+#include "AEAT6012.h"
+
+// The conversion from raw sensor reading to linear position involves a
+// bunch of translations to different scales and unit systems.  To help
+// keep things straight, let's give each scale a name:
+//
+// * "Raw" refers to the readings directly from the sensor.  These are
+//   unsigned ints in the range 0..scaleMax, and represent angles in a
+//   unit system where one increment equals 360/scaleMax degrees.  The
+//   zero point is arbitrary, determined by the physical orientation
+//   of the sensor.
+//
+// * "Biased" refers to angular units with a zero point equal to the
+//   park position.  This uses the same units as the "raw" system, but
+//   the zero point is adjusted so that 0 always means the park position.
+//   Negative values are forward of the park position.  This scale is
+//   also adjusted for wrapping, by ensuring that the value lies in the
+//   range -(maximum forward excursion) to +(scale max - max fwd excursion).
+//   Any values below or above the range are bumped up or down (respectively)
+//   to wrap them back into the range.
+//
+// * "Linear" refers to the final linear results, in joystick units, on
+//   the abstract integer scale from 0..65535 used by the generic plunger
+//   base class.
+// 
+class PlungerSensorRotary: public PlungerSensor
+{
+public:
+    PlungerSensorRotary(int scaleMax, float radiansPerSensorUnit) : 
+        PlungerSensor(65535),
+        scaleMax(scaleMax),
+        radiansPerSensorUnit(radiansPerSensorUnit)
+    {   
+        // start our sample timer with an arbitrary zero point of now
+        timer.start();
+        
+        // clear the timing statistics
+        nReads = 0;
+        totalReadTime = 0;
+        
+        // Pre-calculate the maximum forward excursion distance, in raw
+        // units.  For our reference mechanical setup with "D" in a likely
+        // range, theta(max) is always about 10 degrees higher than
+        // theta(park).  10 degrees is about 1/36 of the overall circle,
+        // which is the same as 1/36 of the sensor scale.  To be 
+        // conservative, allow for about 3X that, so allow 1/12 of scale
+        // as the maximum forward excursion.  For wrapping purposes, we'll
+        // consider any reading outside of the range from -(excursion)
+        // to +(scaleMax - excursion) to be wrapped.
+        maxForwardExcursion = scaleMax/12;
+                
+        // reset the calibration counters
+        biasedMinObserved = biasedMaxObserved = 0;
+    }
+    
+    // Restore the saved calibration at startup
+    virtual void restoreCalibration(Config &cfg)
+    {
+        // only proceed if there's calibration data to retrieve
+        if (cfg.plunger.cal.calibrated)
+        {
+            // we store the raw park angle in raw0
+            rawParkAngle = cfg.plunger.cal.raw0;
+            
+            // we store biased max angle in raw1
+            biasedMax = cfg.plunger.cal.raw1;
+        }
+        else
+        {
+            // Use the current sensor reading as the initial guess at the
+            // park position.  The system is usually powered up with the
+            // plunger at the neutral position, so this is a good guess in
+            // most cases.  If the plunger has been calibrated, we'll restore
+            // the better guess when we restore the configuration later on in
+            // the initialization process.
+            rawParkAngle = 0;
+            readSensor(rawParkAngle);
+
+            // Set an initial wild guess at a range equal to +/-35 degrees.
+            // Note that this is in the "biased" coordinate system - raw
+            // units, but relative to the park angle.  The park angle is
+            // about 25 degrees in this setup.
+            biasedMax = (35 + 25) * scaleMax/360;        
+        }
+            
+        // recalculate the vertical angle
+        updateAlpha();
+    }
+    
+    // Begin calibration
+    virtual void beginCalibration(Config &)
+    {
+        // Calibration starts out with the plunger at the park position, so
+        // we can take the current sensor reading to be the park position.
+        rawParkAngle = 0;
+        readSensor(rawParkAngle);
+        
+        // Reset the observed calibration counters
+        biasedMinObserved = biasedMaxObserved = 0;
+    }
+    
+    // End calibration
+    virtual void endCalibration(Config &cfg)
+    {
+        // apply the observed maximum angle
+        biasedMax = biasedMaxObserved;
+        
+        // recalculate the vertical angle
+        updateAlpha();
+
+        // save our raw configuration data
+        cfg.plunger.cal.raw0 = static_cast<uint16_t>(rawParkAngle);
+        cfg.plunger.cal.raw1 = static_cast<uint16_t>(biasedMax);
+        
+        // Refigure the range for the generic code
+        cfg.plunger.cal.min = biasedAngleToLinear(biasedMinObserved);
+        cfg.plunger.cal.max = biasedAngleToLinear(biasedMaxObserved);
+        cfg.plunger.cal.zero = biasedAngleToLinear(0);
+    }
+    
+    // figure the average scan time in microseconds
+    virtual uint32_t getAvgScanTime() 
+    { 
+        return nReads == 0 ? 0 : static_cast<uint32_t>(totalReadTime / nReads);
+    }
+        
+    // read the sensor
+    virtual bool readRaw(PlungerReading &r)
+    {
+        // note the starting time for the reading
+        uint32_t t0 = timer.read_us();
+        
+        // read the angular position
+        int angle;
+        if (!readSensor(angle))
+            return false;
+        
+        // Refigure the angle relative to the raw park position.  This
+        // is the "biased" angle.
+        angle -= rawParkAngle;
+        
+        // Adjust for wrapping.
+        //
+        // An angular sensor reports the position on a circular scale, for
+        // obvious reasons, so there's some point along the circle where the
+        // angle is zero.  One tick before that point reads as the maximum
+        // angle on the scale, so we say that the scale "wraps" at that point.
+        //
+        // To correct for this, we can look to the layout of the mechanical
+        // setup to constrain the values.  Consider anything below the maximum
+        // forward exclusion to be wrapped on the low side, and consider
+        // anything outside of the complementary range on the high side to
+        // be wrapped on the high side.
+        if (angle < -maxForwardExcursion)
+            angle += scaleMax;
+        else if (angle >= scaleMax - maxForwardExcursion)
+            angle -= scaleMax;
+            
+        // Note if this is the highest/lowest observed reading on the biased 
+        // scale since the last calibration started.
+        if (angle > biasedMaxObserved)
+            biasedMaxObserved = angle;
+        if (angle < biasedMinObserved)
+            biasedMinObserved = angle;
+            
+        // figure the linear result
+        r.pos = biasedAngleToLinear(angle);
+        
+        // Set the timestamp on the reading to right now
+        uint32_t now = timer.read_us();
+        r.t = now;
+        
+        // count the read statistics
+        totalReadTime += now - t0;
+        nReads += 1;        
+        
+        // success
+        return true;
+    }
+    
+private:
+    // Read the underlying sensor - implemented by the hardware-specific
+    // subclasses.  Returns true on success, false if the sensor can't
+    // be read.  The angle is returned in raw sensor units.
+    virtual bool readSensor(int &angle) = 0;
+
+    // Convert a biased angle value to a linear reading
+    int biasedAngleToLinear(int angle)
+    {
+        // Translate to an angle relative to the vertical, in sensor units
+        int angleFromVert = angle - alpha;
+        
+        // Translate the angle in sensor units to radians
+        float theta = static_cast<float>(angleFromVert) * radiansPerSensorUnit;
+        
+        // Calculate the linear position
+        return static_cast<int>(tanf(theta) * linearScaleFactor);
+    }
+
+    // Update the estimation of the vertical angle, based on the angle
+    // between the park position and maximum retraction point.
+    void updateAlpha()
+    {
+        // See the comments at the top of the file for details on this
+        // formula.  This figures the angle between the park position
+        // and the vertical by applying the known constraints of the
+        // mechanical setup: the known length of a standard plunger,
+        // and the requirement that the rotation axis be placed at
+        // roughly the midpoint of the plunger travel.
+        const float C = 1.4848489f; // 1-17/32" / 1-1/32"
+        float T = tanf(biasedMax * radiansPerSensorUnit);
+        float a = atanf((sqrtf(4*T*T*C + C*C + 2*C + 1) - C - 1)/(2*T*C));
+        
+        // Convert back to sensor units.  Note that alpha represents
+        // a relative angle between two specific points, so it's not
+        // further biased to any absolute point.
+        alpha = static_cast<int>(a / radiansPerSensorUnit);
+        
+        // While we're at it, figure the linear conversion factor.  The
+        // goal is to use most of the abstract axis range, 0..65535.
+        // To avoid overflow, though, leave a little headroom.
+        const float safeMax = 60000.0f;
+        linearScaleFactor = static_cast<int>(safeMax /
+            tanf(static_cast<float>(biasedMax - alpha) * radiansPerSensorUnit));
+    }
+
+    // Maximum raw angular reading from the sensor.  The sensor's readings
+    // will always be on a scale from 0..maxAngle.
+    int scaleMax;
+    
+    // Radians per sensor unit.  This is a constant for the sensor.
+    float radiansPerSensorUnit;
+    
+    // Pre-calculated value of the maximum forward excursion, in raw units.
+    int maxForwardExcursion;
+    
+    // Raw reading at the park position.  We use this to handle "wrapping",
+    // if the sensor's raw zero reading position is within the plunger travel
+    // range.  All readings are taken to be within 
+    int rawParkAngle;
+    
+    // Biased maximum angle.  This is the angle at the maximum retracted
+    // position, in biased units (sensor units, relative to the park angle).
+    int biasedMax;
+    
+    // Mininum and maximum angle observed since last calibration start, on 
+    // the biased scale
+    int biasedMinObserved;
+    int biasedMaxObserved;
+    
+    // The "alpha" angle - the angle between the park position and the
+    // vertical line between the rotation axis and the plunger.  This is
+    // represented in sensor units.
+    int alpha;
+    
+    // The linear scaling factor, applied in our trig calculation from
+    // angle to linear position.  This corresponds to the distance from
+    // the rotation center to the plunger rod, but since the linear result
+    // is in abstract joystick units, this distance is likewise in abstract
+    // units.  The value isn't chosen to correspond to any real-world 
+    // distance units, but rather to yield a joystick result that takes
+    // advantage of most of the available axis range, to minimize rounding
+    // errors when converting between scales.
+    float linearScaleFactor;
+
+    // timer for input timestamps and read timing measurements
+    Timer timer;
+    
+    // read timing statistics
+    uint64_t totalReadTime;
+    uint64_t nReads;
+    
+    // Keep track of when calibration is in progress.  The calibration
+    // procedure is usually handled by the generic main loop code, but
+    // in this case, we have to keep track of some of the raw sensor
+    // data during calibration for our own internal purposes.
+    bool calibrating;
+};
+
+// Specialization for the AEAT-601X sensors
+template<int nDataBits> class PlungerSensorAEAT601X : public PlungerSensorRotary
+{
+public:
+    PlungerSensorAEAT601X(PinName csPin, PinName clkPin, PinName doPin) :
+        PlungerSensorRotary((1 << nDataBits) - 1, 6.283185f/((1 << nDataBits) - 1)),
+        aeat(csPin, clkPin, doPin) 
+    {
+        // Make sure the sensor has had time to finish initializing.
+        // Power-up time (tCF) from the data sheet is 20ms for the 12-bit
+        // version, 50ms for the 10-bit version.
+        wait_ms(nDataBits == 12 ? 20 :
+            nDataBits == 10 ? 50 :
+            50);
+    }
+
+    // read the angle
+    virtual bool readSensor(int &angle)
+    {
+        angle = aeat.readAngle();
+        return true;
+    }
+        
+protected:
+    // physical sensor interface
+    AEAT601X<nDataBits> aeat;
+};
+