#include "mbed.h"
#include "MODSERIAL.h"
#include "BiQuad.h"
#include "HIDScope.h"
#include <math.h>
//ATTENTION: set mBed to version 151
// set QEI to version 0, (gebruiken wij (nog) niet, is voor encoder)
// set MODSERIAL to version 44
// set HIDScope to version 7
// set biquadFilter to version 7
AnalogIn emg0_in (A0); //First raw EMG signal input
AnalogIn emg1_in (A1); //Second raw EMG signal input
AnalogIn emg2_in (A2); //Third raw EMG signal input
InterruptIn button1 (D10); //Is this one available? We need to make a map of which pins are used for what.
InterruptIn button2 (D11);
DigitalOut directionpin1 (D7);
DigitalOut directionpin2 (D4);
PwmOut pwmpin1 (D6);
PwmOut pwmpin2 (D5);
DigitalOut ledr (LED_RED);
DigitalOut ledb (LED_BLUE);
DigitalOut ledg (LED_GREEN);
MODSERIAL pc(USBTX, USBRX); //Serial communication to see if the code works step by step, turn on if hidscope is off
//HIDScope scope( 6 ); //HIDScope set to 3x2 channels for 3 muscles, raw data + filtered
//Tickers
Ticker HIDScope_tick; //Ticker for HIDScope
Ticker filter_tick; //Ticker for EMG filter
Ticker MovAg_tick; //Ticker to calculate Moving Average
Ticker Motor_tick; //Ticker motor aansturen
//Global variables
const float T = 0.002f; //Ticker period
//EMG filter
double emg0_filt, emg1_filt, emg2_filt; //Variables for filtered EMG data channel 0, 1 and 2
double emg0_raw, emg1_raw, emg2_raw;
double emg0_filt_x, emg1_filt_x, emg2_filt_x;
const int windowsize = 150; //Size of the array over which the moving average (MovAg) is calculated. (random number)
double sum, sum1, sum2, sum3; //variables used to sum elements in array
double StoreArray0[windowsize], StoreArray1[windowsize], StoreArray2[windowsize]; //Empty arrays to calculate MoveAg
double movAg0, movAg1, movAg2; //outcome of MovAg (moet dit een array zijn??)
//Calibration variables
int x = -1; //Start switch, colour LED is blue.
int emg_cal = 0; //if emg_cal is set to 1, motors can begin to work in this code (!!)
const int sizeCal = 1500; //size of the dataset used for calibration, eerst 2000
double StoreCal0[sizeCal], StoreCal1[sizeCal], StoreCal2[sizeCal]; //arrays to put the dataset of the calibration in
double Mean0,Mean1,Mean2; //average of maximum tightening
double Threshold0, Threshold1, Threshold2;
//Biquad //Variables for the biquad band filters (alle 3 dezelfde maar je kan niet 3x 'emg0band' aanroepen ofzo)
BiQuadChain emg0filter;
BiQuad emg0band1( 7.29441e-01, -1.89276e-08, -7.29450e-01, -1.64507e-01, -7.26543e-01 );
BiQuad emg0band2( 1.00000e+00, 1.99999e+00, 9.99994e-01, 1.72349e+00, 7.79616e-01 );
BiQuad emg0band3( 1.00000e+00, -1.99999e+00, 9.99994e-01, -1.93552e+00, 9.39358e-01 );
BiQuad notch1( 9.91104e-01, -1.60364e+00, 9.91104e-01, -1.60364e+00, 9.82207e-01 ); //Notch filter biquad coefficients
BiQuadChain emg1filter;
BiQuad emg1band1( 7.29441e-01, -1.89276e-08, -7.29450e-01, -1.64507e-01, -7.26543e-01 );
BiQuad emg1band2( 1.00000e+00, 1.99999e+00, 9.99994e-01, 1.72349e+00, 7.79616e-01 );
BiQuad emg1band3( 1.00000e+00, -1.99999e+00, 9.99994e-01, -1.93552e+00, 9.39358e-01 );
BiQuad notch2( 9.91104e-01, -1.60364e+00, 9.91104e-01, -1.60364e+00, 9.82207e-01 ); //Notch filter
BiQuadChain emg2filter;
BiQuad emg2band1( 7.29441e-01, -1.89276e-08, -7.29450e-01, -1.64507e-01, -7.26543e-01 );
BiQuad emg2band2( 1.00000e+00, 1.99999e+00, 9.99994e-01, 1.72349e+00, 7.79616e-01 );
BiQuad emg2band3( 1.00000e+00, -1.99999e+00, 9.99994e-01, -1.93552e+00, 9.39358e-01 );
BiQuad notch3( 9.91104e-01, -1.60364e+00, 9.91104e-01, -1.60364e+00, 9.82207e-01 ); //Notch filter
//Functions
void switch_to_calibrate()
{
x++; //Every time function gets called, x increases. Every button press --> new calibration state.
//Starts with x = -1. So when function gets called 1 time, x = 0. In the end, x = 4 will reset to -1.
if(x==0) //If x = 0, led is red
{
ledr = 0;
ledb = 1;
ledg = 1;
}
else if (x==1) //If x = 1, led is blue
{
ledr = 1;
ledb = 0;
ledg = 1;
}
else if (x==2) //If x = 2, led is green
{
ledr = 1;
ledb = 1;
ledg = 0;
}
else //If x = 3 or 4, led is white
{
ledr = 0;
ledb = 0;
ledg = 0;
}
if(x==4) //Reset back to x = -1
{
x = -1;
emg_cal=0; //reset, motors off
}
}
void calibrate(void)
{
switch(x)
{
case 0: //If calibration state 0:
{
sum = 0.0;
for(int j = 0; j<=sizeCal-1; j++) //Array filled with datapoints from the EMGfilter signal of muscle 0
{
StoreCal0[j] = emg0_filt;
sum+=StoreCal0[j];
wait(0.001f); //Does there need to be a wait?
}
Mean0 = sum/sizeCal; //Calculate mean of the datapoints in the calibration set (2000 samples)
Threshold0 = Mean0/2; //Threshold calculation = 0.5*mean
break; //Stop. Threshold is calculated, we will use this further in the code
}
case 1: //If calibration state 1:
{
sum = 0.0;
for(int j = 0; j<=sizeCal-1; j++) //Array filled with datapoints from the EMGfilter signal of muscle 1
{
StoreCal1[j] = emg1_filt;
sum+=StoreCal1[j];
wait(0.001f);
}
Mean1 = sum/sizeCal;
Threshold1 = Mean1/2;
break;
}
case 2: //If calibration state 2:
{
sum = 0.0;
for(int j = 0; j<=sizeCal-1; j++) //Array filled with datapoints from the EMGfilter signal of muscle 2
{
StoreCal2[j] = emg2_filt;
sum+=StoreCal2[j];
wait(0.001f);
}
Mean2 = sum/sizeCal;
Threshold2 = Mean2/2;
break;
}
case 3: //EMG is calibrated, robot can be set to Home position.
{
emg_cal = 1; //This is the setting for which the motors can begin turning in this code (!!)
wait(0.001f);
break;
}
default: //Ensures nothing happens if x is not 0,1 or 2.
{
break;
}
}
}
void HIDScope_sample()
{
/* Set the sampled emg values in channel 0 (the first channel) and 1 (the second channel) in the 'HIDScope' instance named 'scope' */
//scope.set(0,emg0_raw);
//scope.set(1,emg0_filt);
//scope.set(1,movAg0); //als moving average werkt
//scope.set(2,emg1_raw);
//scope.set(3,emg1_filt);
//scope.set(3,movAg1); //als moving average werkt
//scope.set(4,emg2_raw);
//scope.set(5,emg2_filt);
//scope.set(5,movAg2); //als moving average werkt
//scope.send(); //Send data to HIDScope server
}
void EMGFilter0()
{
emg0_raw = emg0_in.read(); //give name to raw EMG0 data
emg0_filt_x = emg0filter.step(emg0_raw); //Use biquad chain to filter raw EMG data
emg0_filt = abs(emg0_filt_x); //rectifier. LET OP: volgorde filter: band-notch-rectifier. Eerst band-rect-notch, stel er komt iets raars uit, dan Notch uit de biquad chain halen en aparte chain voor aanmaken.
}
void EMGFilter1()
{
emg1_raw = emg1_in.read(); //give name to raw EMG1 data
emg1_filt_x = emg1filter.step(emg1_raw); //Use biquad chain to filter raw EMG data
emg1_filt = abs(emg1_filt_x); //rectifier. LET OP: volgorde filter: band-notch-rectifier. Eerst band-rect-notch.
}
void EMGFilter2()
{
emg2_raw = emg2_in.read(); //Give name to raw EMG1 data
emg2_filt_x = emg2filter.step(emg2_raw); //Use biquad chain to filter raw EMG data
emg2_filt = abs(emg2_filt_x); //Rectifier. LET OP: volgorde filter: band-notch-rectifier.
}
void MovAg() //Calculate moving average (MovAg), klopt nog niet!!
{
for (int i = windowsize-1; i>=0; i--) //Make arrays for the last datapoints of the filtered signals
{
StoreArray0[i] = StoreArray0[i-1]; //Shifts the i'th element one place to the right, this makes it "rolling or moving" average.
StoreArray1[i] = StoreArray1[i-1];
StoreArray2[i] = StoreArray2[i-1];
}
StoreArray0[0] = emg0_filt; //Stores the latest datapoint of the filtered signal in the first element of the array
StoreArray1[0] = emg1_filt;
StoreArray2[0] = emg2_filt;
sum1 = 0.0;
sum2 = 0.0;
sum3 = 0.0;
for(int a = 0; a<= windowsize-1; a++) //Sums the elements in the arrays
{
sum1 += StoreArray0[a];
sum2 += StoreArray1[a];
sum3 += StoreArray2[a];
}
movAg0 = sum1/windowsize; //calculates an average in the array
movAg1 = sum2/windowsize;
movAg2 = sum3/windowsize;
//serial getallen sturen, als het 1 getal is gaat hier wat fout, als het een reeks is dan gaat er bij de input naar HIDscope wat fout.
}
void emg_filtered() //Call all filter functions
{
EMGFilter0();
EMGFilter1();
EMGFilter2();
}
void motor_control()
{
while(emg_cal==1) //After calibration is finished, emg_cal will be 1. Otherwise 0.
{
if(movAg0>Threshold0) //If the filtered EMG signal of muscle 0 is higher than the threshold, motor1 will turn in 1 direction
{
pwmpin1 = 1;
directionpin1.write(1); //translatie vooruit
ledr = 1; //Blue
ledb = 0;
ledg = 1;
}
else if(movAg1>Threshold1) //If the filtered EMG signal of muscle 1 is higher than the threshold, motor2 will turn in 1 direction
{
pwmpin2 = 1;
directionpin2.write(1); //rotatie omhoog
ledr = 0; //red
ledb = 1;
ledg = 1;
}
else if(movAg2>Threshold2) //If the filtered EMG signal of muscle 2 is higher than the threshold, motor 1 and 2 will turn
{
pwmpin1 = 1;
pwmpin2 = 1;
directionpin1.write(0); //translatie achteruit
directionpin2.write(0); //rotatie omlaag
ledr = 1; //green
ledb = 1;
ledg = 0;
}
else //If not higher than the threshold, motors will not turn at all
{
pwmpin1 = 0; //Motoren doen niets
pwmpin2 = 0;
ledr = 0; //white
ledb = 0;
ledg = 0;
}
break;
}
}
int main()
{
pc.baud(115200);
pc.printf("Hello World!\r\n"); //Serial communication only works if hidscope is turned off.
pwmpin1.period_us(60); //60 microseconds PWM period, 16.7 kHz
emg0filter.add( &emg0band1 ).add( &emg0band2 ).add( &emg0band3 ).add( ¬ch1 ); //attach biquad elements to chain
emg1filter.add( &emg1band1 ).add( &emg1band2 ).add( &emg1band3 ).add( ¬ch2 );
emg2filter.add( &emg2band1 ).add( &emg2band2 ).add( &emg2band3 ).add( ¬ch3 );
while(true)
{
filter_tick.attach(&emg_filtered,T); //EMG signals filtered every T sec.
MovAg_tick.attach(&MovAg,T); //Moving average calculation every T sec.
Motor_tick.attach(&motor_control,T); //Test motor control
// HIDScope_tick.attach(&HIDScope_sample,T); //EMG signals raw + filtered to HIDScope every T sec.
button1.rise(switch_to_calibrate); //Switch state of calibration (which muscle)
wait(0.2f); //Wait to avoid bouncing of button
button2.rise(calibrate); //Calibrate threshold for 3 muscles
wait(0.2f); //Wait to avoid bouncing of button
pc.printf("x is %i\n\r",x);
pc.printf("Movag0 = %f , Movag1 = %f, Movag2 = %f \n\r",movAg0, movAg1, movAg2);
pc.printf("Thresh0 = %f , Thresh1 = %f, Thresh2 = %f \n\r",Threshold0, Threshold1, Threshold2);
//wait(2.0f);
}
}