Library to interface with the MAX31855 Cold Junction Compensated Thermocouple-to-Digital Converter
Fork of MAX31855 by
The libary is from Joe Station. The conversion factor for the internal chip temperature is changed from 0.25 to 0.0625 to read out the correct chip temperature.
History
Max31855 from Joe Staton (internal Chip-temperatur conversation factor corrected from 0.25 to 0.0625 to read out the correct chip temperature)
2014-03-07, by Franky_74 [Fri, 07 Mar 2014 09:57:48 +0000] rev 2
Max31855 from Joe Staton (internal Chip-temperatur conversation factor corrected from 0.25 to 0.0625 to read out the correct chip temperature)
Fixed fault reporting. Returns a value of 2000 + fault code on error.
2012-10-23, by Stavlin [Tue, 23 Oct 2012 10:51:21 +0000] rev 1
Fixed fault reporting. Returns a value of 2000 + fault code on error.
Initial library release
2012-08-16, by Stavlin [Thu, 16 Aug 2012 12:46:52 +0000] rev 0
Initial library release