Firmware updater for SCM-LTE-01 and SCM-LTE-BETA

Dependencies:   SakuraIO mbed

Revision:
1:f5ba096817a0
Parent:
0:d48db604880f
Child:
2:fe531746e3f4
--- a/main.cpp	Thu Sep 07 07:08:46 2017 +0000
+++ b/main.cpp	Thu Sep 07 07:30:12 2017 +0000
@@ -13,7 +13,7 @@
 // Nucleo-64 series
 SPI spi(D11, D12, D13); // mosi, miso, sclk
 DigitalOut cs(D10);
-I2C i2c(D14, D15);
+I2C i2c(D14, D15);     
 #else
 // LPC1768 or others.
 SPI spi(p5, p6, p7); // mosi, miso, sclk
@@ -39,7 +39,7 @@
             pc.printf("SCM-LTE-01\r\n");
             break;
         default:
-            pc.printf("Please check connection\r\n");
+            pc.printf("Please check connection %d\r\n", productId);
             return 1;
     }
 
@@ -64,7 +64,7 @@
         pc.printf("Error code=%d\r\n", ret);
         return 1;
     }
-    pc.printf("Current: %s", version);
+    pc.printf("Current: %s\r\n", version);
 
 
     wait_ms(1000);