This program simply connects to a HTS221 I2C device to read Temperature & Humidity, and a WNC Cellular Module both of which are on the Avnet WNC Shield.

Dependencies:   mbed FXOS8700CQ

/media/uploads/JMF/avnet_logo.gif

AT&T Shape Hackathon QuickStart Instructions

  • One area that has been problematic is setting the the MY_SERVER_URL. When you copy the URL from the flow, you must make sure that the MY_SERVER_URL is also set to the appropirate server. It can be either "run-east.att.io" or "run-west.att.io", so be sure to check this.

Useful Links

Adding Additional Sensors

The FLOW_DEVICE_NAME field must contain the name of the instance of the Virtual Starter kit in FLOW that you will be communicating with. Usually this will be "vstarterkit001", but if you have problems communicating you can verify that this is indeed correct. Note that this device will not be created until you click the “Initialize” input on the Virtual Device tab of the Starter Kit project in FLOW. At that point it becomes available in M2X and you can see it there, as the DEVICE SERIAL field under Devices as in the image below.

Sensors: When executing, the FRDM-K64F board will upload sensor measurements to AT&T’s Flow environment every 5 seconds, using the Cellular shield board. You can adjust how often you want to do this by editing the SENSOR_UPDATE_INTERVAL_MS value in the header file. Temperature and humidity: By default the board will report readings from the HTS221 temperature and humidity sensor. These two values are sent to the HTTP IN /climate port in FLOW with field names “temp” and “humidity”. Temperature is in degrees Fahrenheit and humidity is a %. This default assignment is: iSensorsToReport = TEMP_HUMIDITY_ONLY;

Accelerometer: If you want to expand and use the on-board motion sensor, you can also send 3-axis accelerometer information from the board as “accelX”, “accelY” and “accelZ”. This is useful if you want to know the stationary position of the board with regards to gravity, or whether it is in motion. These readings are in g’s. To send these values, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER;

PMOD Sensors: If you have a Silicon Labs sensor module that can plug into the PMOD connector on the Cellular shield, you will also be able to measure proximity, UV light, ambient visible and infrared light from the Si1145 sensor. This PMOD also has a temperature and humidity sensor, but in this case it is redundant. When enabled, the fields “proximity”, “light_uv”, “light_vis” and “light_ir” will also be sent. To enable all these sensors, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS;

Connecting up the PMOD sensors: Because the pinouts do not align, the SiLabs PMOD sensor board cannot be plugged into the J10 PMOD receptacle on the shield directly. The following wiring instructions must be used:

Signal=J10=(Shield) PMOD=Color in the image below
VCCPin 6Pin 6Red
GNDPin 5Pin 5Black
SDAPin4Pin 3Green
SCLPin3Pin 2Yellow

Link to AT&T M2X

M2X

Link to AT&T Flow

FLOW

Avnet WNC-Shield Information

Getting Started with the Avnet WNC-Shield & Hackathon software

  • This project uses Revision 119 of the MBED library because of I2C implementation differences with the tip (Revision 121)
  • This project uses Revision 4 of the FXOS8700CQ library for sensors

Easily modifiable parameters in source code

Inside the mbed “AvnetATT_shape_hackathon” project, the parameters that are needed to customize your board are in the config_me.h file.

  • FLOW parameters: This project assumes that you are using a fork of the “Starter Kit Base” project, which is a reference design that was created using AT&T’s FLOW (https://flow.att.com) that allows the creation of on-line virtualization and other IoT functionality. The default parameters in the config_me.h file are done for a specific instance of this project. When you fork the original project, you get your own instance and it will have its own base address. At the bottom of the FLOW environment, when you click on the “Endpoints” tab, you will see the URL information that is specific to your instance. Of note is the Base URL. In the example below (as in the default mbed project), the Base URL is: https://run-west.att.io/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow You have to take note of two parts of this address. The run-west.att.io part is the server URL, and you have to make sure the
  • MY_SERVER_URL field in config_me.h matches this. Then there is the rest of the base URL, in green above, that needs to be pasted into the FLOW_BASE_URL field.

There is also a FLOW_INPUT_NAME field. This should match the name of the HTTP IN port in the FLOW project that you want to send sensor data to. The default is "/climate", as in the FLOW image below.

/media/uploads/JMF/sf.png

Where is the binary I compiled

When the COMPILE button is pressed, it will compile your project and link it. The result is placed in the DOWNLOAD folder you use when downloading files from the internet. It will be called AvnetATT_shape_hackathon_K64F.bin.

Additional information on compiling/configuring

Comprehensive instructions can be found at: Quick Start Instructions

Revision:
14:0c353e212296
Parent:
12:7c94ec5069dc
Child:
16:17c5916f2d12
--- a/main.cpp	Tue Jul 12 21:58:17 2016 +0000
+++ b/main.cpp	Wed Jul 13 00:39:08 2016 +0000
@@ -47,6 +47,8 @@
 DigitalOut  mdm_power_on(PTB9);                 // 0 = turn modem on, 1 = turn modem off (should be held high for >5 seconds to cycle modem)
 DigitalOut  mdm_wakeup_in(PTC2);                // 0 = let modem sleep, 1 = keep modem awake -- Note: pulled high on shield
 
+DigitalOut  mdm_reset(PTC12);                   // active high      
+
 DigitalOut  shield_3v3_1v8_sig_trans_ena(PTC4); // 0 = disabled (all signals high impedence, 1 = translation active
 DigitalOut  mdm_uart1_cts(PTD0);
 
@@ -132,9 +134,23 @@
 }
 
 int mdm_init(void) {
-    // disable signal level translator
+    // disable signal level translator (necessary
+    // for the modem to boot properly)
     shield_3v3_1v8_sig_trans_ena = 0;
 
+    // Hard reset the modem (doesn't go through
+    // the signal level translator)
+    mdm_reset = 1;
+    
+   // wait a moment for the modem to react
+    wait_ms(10);
+    
+    // Let modem boot
+    mdm_reset = 0;
+    
+    // wait a moment for the modem to react
+    wait(1.0);
+    
     // power modem on //off
     mdm_power_on = 0; //1;
     
@@ -151,6 +167,13 @@
 
     mdm_uart1_cts = 0;
     
+    // wait a moment for the modem to react to signal
+    // conditions while the level translator is disabled
+    // (sorry, don't have enough information to know
+    // what exactly the modem is doing with the current
+    // pin settings)
+    wait(1.0);
+
     // enable the signal level translator to start
     // modem reset process (modem will be powered down)
     shield_3v3_1v8_sig_trans_ena = 1;
@@ -163,7 +186,7 @@
         const char * rsp_lst[] = { ok_str, error_str, NULL };
         int rc = mdm_sendAtCmd("AT", rsp_lst, 500);
         if (rc == 0)
-            return timer.read();
+            return true; //timer.read();
         wait_ms(1000 - (timer.read_ms() % 1000));
         pc.printf("\r%d",timer.read_ms()/1000);
     }
@@ -332,11 +355,12 @@
 
     // Initialize the modem
     printf(GRN "Modem initializing... will take up to 60 seconds" DEF "\r\n");
-    i=mdm_init();
-    if (!i) {
-        pc.printf(RED "Modem initialization failed!" DEF "\n");
-        while (1);
-    }
+    do {
+        i=mdm_init();
+        if (!i) {
+            pc.printf(RED "Modem initialization failed!" DEF "\n");
+        }
+    } while (!i);
     
     //Software init
     software_init_mdm();