This program connects to a few sensors via I2C and sends the data collected to a WNC Cellular Module which is located on an Avnet WNC-Shield card.

Dependencies:   FXOS8700CQ MODSERIAL mbed

/media/uploads/kevinkeryk/avnet_logo_tagline_rgb.png

Avnet Cellular IoT Instructions

  • One problematic area is setting the MY_SERVER_URL. When you copy the URL from the flow, you must make sure the MY_SERVER_URL is also set to the appropriate server. It can be either "run-east.att.io" or "run-west.att.io".

Useful Links

Adding Additional Sensors

The FLOW_DEVICE_NAME field must contain the name of the instance of the Virtual Starter Kit in FLOW you will be communicating with. Usually this is "vstarterkit001", but if you have problems communicating you can verify this is correct. Note: This device will not be created until you click the “Initialize” input on the Virtual Device tab of the Starter Kit project in FLOW. At that point, it becomes available in M2X and you can see it as the DEVICE SERIAL field under Devices as in the image below. /media/uploads/JMF/vstarterkit.png

Sensors: When executing, the FRDM-K64F board uploads sensor measurements to AT&T’s Flow environment every 5 seconds, using the Cellular shield board. You can adjust how often you want to do this by editing the SENSOR_UPDATE_INTERVAL_MS value in the header file.

Temperature and humidity: By default, the board reports readings from the HTS221 temperature and humidity sensor. These two values are sent to the HTTP IN /climate port in FLOW with field names “temp” and “humidity”. Temperature is in degrees Fahrenheit and humidity is a %. This default assignment is: iSensorsToReport = TEMP_HUMIDITY_ONLY;

Accelerometer: If you want to expand and use the onboard motion sensor, you can also send 3-axis accelerometer information from the board as “accelX”, “accelY”, and “accelZ”. This is useful if you want to know the stationary position of the board with regards to gravity, or whether it is in motion. These readings are in g’s. To send these values, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER;

PMOD Sensors: If you have a Silicon Labs sensor module that can plug into the PMOD connector on the Cellular shield, you are able to measure proximity, UV light, ambient visible and infrared light from the Si1145 sensor. This PMOD also has a temperature and humidity sensor, but in this case it is redundant. When enabled, the fields “proximity”, “light_uv”, “light_vis” and “light_ir” are also sent. To enable all these sensors, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS;

Connecting the PMOD sensors: Because the pinouts do not align, the SiLabs PMOD sensor board cannot be plugged into the J10 PMOD receptacle on the shield directly. The following wiring instructions must be followed:

SignalJ10ShieldPMOD Color in the image below
VCCPin 6Pin 6Red
GNDPin 5Pin 5Black
SDAPin4Pin 3Green
SCLPin3Pin 2Yellow

/media/uploads/JMF/xyz.jpg

AT&T M2X and FLOW Instructions

M2X & FLOW Instructions

Link to AT&T M2X

M2X

Link to AT&T Flow

FLOW

Avnet WNC-Shield Information

Getting Started with the Avnet WNC-Shield Software

  • This project uses Revision 119 of the MBED library because of I2C implementation differences with the tip (Revision 121).
  • This project uses Revision 4 of the FXOS8700CQ library for sensors.

Easily Modifiable Parameters

Inside the mbed Avnet_ATT_Cellular_IOT project, the parameters needed to customize your board are in the config_me.h file.

  • FLOW parameters: This project assumes you are using a fork of the Starter Kit Base project, which is a reference design created using AT&T’s FLOW (https://flow.att.com) that allows the creation of online virtualization and other IoT functionality. The default parameters in the config_me.h file are done for a specific instance of this project. When you fork the original project, you get your own instance and it will have its own base address. At the bottom of the FLOW environment, when you click on the Endpoints tab, URL information that is specific to your instance is displayed. Of note is the Base URL. In the example below (as in the default mbed project), the Base URL is: https://run-west.att.io/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow You have to take note of two parts of this address. The run-west.att.io part is the server URL, and you have to make sure the
  • MY_SERVER_URL field in config_me.h matches this. The rest of the base URL, in green above, needs to be pasted into the FLOW_BASE_URL field.

There is also a FLOW_INPUT_NAME field. This should match the name of the HTTP IN port in the FLOW project that you want to send sensor data to. The default is "/climate", as in the FLOW image below.

/media/uploads/JMF/sf.png

Where is the Binary I compiled

When the COMPILE button is pressed, it compiles your project and links it. The result is placed in the DOWNLOAD folder you use when downloading files from the Internet. It will be called AvnetATT_shape_hackathon_K64F.bin.

Additional Information on Compiling/Configuring

Comprehensive instructions can be found at: Quick Start Instructions

Committer:
fkellermavnet
Date:
Sun Jul 24 21:56:14 2016 +0000
Revision:
51:d9e5952545da
Parent:
50:8ac42961458c
Child:
55:3abf9e3f42e6
Changed back to ATT server (from last commit, was google).

Who changed what in which revision?

UserRevisionLine numberNew contents of line
JMF 2:0e2ef866af95 1 #ifndef __CONFIG_ME_H_
JMF 2:0e2ef866af95 2 #define __CONFIG_ME_H_
JMF 2:0e2ef866af95 3
JMF 2:0e2ef866af95 4 // User must set these for own context:
fkellermavnet 21:d0038d14ee7c 5
fkellermavnet 50:8ac42961458c 6 #define BUF_SIZE_FOR_N_MAX_SOCKREAD (10)
fkellermavnet 50:8ac42961458c 7 #define MAX_WNC_SOCKREAD_PAYLOAD (1500)
fkellermavnet 50:8ac42961458c 8
fkellermavnet 21:d0038d14ee7c 9 // This is the server's base URL name. Example "www.google.com"
stefanrousseau 24:bd480d2aade4 10 // Note that when you Fork a FLOW, it will typically assign either
stefanrousseau 24:bd480d2aade4 11 // "run-east.att.io" or "run-west.att.io", so be sure to check this.
fkellermavnet 51:d9e5952545da 12 static const char * MY_SERVER_URL = "run-west.att.io";
fkellermavnet 21:d0038d14ee7c 13
stefanrousseau 24:bd480d2aade4 14 // These are FLOW fields from the Endpoints tab:
stefanrousseau 12:7c94ec5069dc 15 #define FLOW_BASE_URL "/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow"
stefanrousseau 12:7c94ec5069dc 16 #define FLOW_INPUT_NAME "/climate"
fkellermavnet 21:d0038d14ee7c 17
stefanrousseau 24:bd480d2aade4 18 // Unless you want to use a different protocol, this field should be left as is:
stefanrousseau 12:7c94ec5069dc 19 #define FLOW_URL_TYPE " HTTP/1.1\r\nHost: "
stefanrousseau 12:7c94ec5069dc 20
stefanrousseau 24:bd480d2aade4 21 // This identifier specifies with which FLOW device you are communicating.
stefanrousseau 24:bd480d2aade4 22 // If you only have one devive there then you can just leave this as is.
stefanrousseau 24:bd480d2aade4 23 // Once your FLOW device has been initialized (Virtual Device Initialize clicked),
stefanrousseau 24:bd480d2aade4 24 // the Virtual Device will show up in M2X. This is its "DEVICE SERIAL" field
fkellermavnet 21:d0038d14ee7c 25 #define FLOW_DEVICE_NAME "vstarterkit001"
fkellermavnet 21:d0038d14ee7c 26
stefanrousseau 24:bd480d2aade4 27 // This constant defines how often sensors are read and sent up to FLOW
stefanrousseau 24:bd480d2aade4 28 #define SENSOR_UPDATE_INTERVAL_MS 5000; //5 seconds
stefanrousseau 24:bd480d2aade4 29
stefanrousseau 24:bd480d2aade4 30 // Specify here how many sensor parameters you want reported to FLOW.
stefanrousseau 24:bd480d2aade4 31 // You can use only the temperature and humidity from the shield HTS221
stefanrousseau 24:bd480d2aade4 32 // or you can add the reading of the FXO8700CQ motion sensor on the FRDM-K64F board
stefanrousseau 24:bd480d2aade4 33 // or if you have a SiLabs PMOD plugged into the shield, you can add its proximity sensor,
stefanrousseau 24:bd480d2aade4 34 // UV light, visible ambient light and infrared ambient light readings
stefanrousseau 12:7c94ec5069dc 35 #define TEMP_HUMIDITY_ONLY 1
stefanrousseau 12:7c94ec5069dc 36 #define TEMP_HUMIDITY_ACCELEROMETER 2
stefanrousseau 12:7c94ec5069dc 37 #define TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS 3
stefanrousseau 24:bd480d2aade4 38 static int iSensorsToReport = TEMP_HUMIDITY_ONLY; //modify this to change your selection
stefanrousseau 12:7c94ec5069dc 39
fkellermavnet 21:d0038d14ee7c 40 // This is the APN name for the cellular network, you will need to change this, check the instructions included with your SIM card kit:
stefanrousseau 12:7c94ec5069dc 41 static const char * MY_APN_STR = "m2m.com.attz";
fkellermavnet 21:d0038d14ee7c 42
fkellermavnet 21:d0038d14ee7c 43 //This is for normal HTTP. If you want to use TCP to a specific port, change that here:
fkellermavnet 21:d0038d14ee7c 44 static const char * MY_PORT_STR = "80";
JMF 2:0e2ef866af95 45
JMF 2:0e2ef866af95 46 #endif