![](/media/cache/group/default_image.jpg.50x50_q85.jpg)
initial commit
Revision 45:f5f553b8c0d5, committed 2020-01-20
- Comitter:
- Vkadaba
- Date:
- Mon Jan 20 10:40:06 2020 +0000
- Parent:
- 44:94bdfaefddac
- Child:
- 46:2c697a0cbbed
- Commit message:
- Added AVDD support
Changed in this revision
--- a/bridge_4w_load_cell_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/bridge_4w_load_cell_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -50,6 +50,8 @@ .powerMode = ADMW1001_POWER_MODE_ACTIVE, }, .measurement = { + .externalRefVoltage=0.0, + .AVDDVoltage=3.0, .operatingMode = ADMW1001_OPERATING_MODE_CONTINUOUS, .dataReadyMode = ADMW1001_DATAREADY_PER_CYCLE, // FIX: Temporarily all values from json are hardcoded to this one in the Contracts.FileGenerator - > file translations!! .groundSwitch = ADMW1001_ADC_GND_SW_CLOSED, @@ -59,14 +61,14 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + // .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = { .enableChannel = true, .disablePublishing = false, .compensationChannel = ADMW1001_CH_ID_NONE, - .lutSelect = ADMW1001_LUT_DEFAULT, + .lutSelect = ADMW1001_LUT_CUSTOM, .measurementUnit = ADMW1001_MEASUREMENT_UNIT_UNSPECIFIED, .lowThreshold = 0, .highThreshold = 45359.2, @@ -75,7 +77,7 @@ .sensorParameter = 0.0, .measurementsPerCycle = 1, .cycleSkipCount = 0, - .extraSettlingTime = 4499.99986449257, + .extraSettlingTime = 5, .priority = 0, .adcChannelConfig = { .sensor = ADMW1001_ADC_SENSOR_BRIDGE_4WIRE_1, @@ -92,4 +94,4 @@ }, }, }, -}; +}; \ No newline at end of file
--- a/common/platform.h Thu Jan 16 06:52:27 2020 +0000 +++ b/common/platform.h Mon Jan 20 10:40:06 2020 +0000 @@ -81,7 +81,7 @@ .misoPin = PLATFORM_SPI_MISO, \ .sckPin = PLATFORM_SPI_SCK, \ .csPin = PLATFORM_SPI_CS, \ - .maxSpeedHz = 1600000, \ + .maxSpeedHz = 1000000, \ }, \ .gpio = { \ .resetPin = PLATFORM_GPIO_RESET, \
--- a/i2c0_sensirionSHT3X_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/i2c0_sensirionSHT3X_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -57,7 +57,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_DIG_I2C_0] = { @@ -67,7 +67,7 @@ .compensationChannel = ADMW1001_CH_ID_NONE, .measurementUnit = ADMW1001_MEASUREMENT_UNIT_UNSPECIFIED, .measurementsPerCycle = 1, - .extraSettlingTime = 15000, + .extraSettlingTime = 15, .i2cChannelConfig = { .sensor = ADMW1001_I2C_SENSOR_HUMIDITY_B, },
--- a/inc/admw1001/admw1001_config.h Thu Jan 16 06:52:27 2020 +0000 +++ b/inc/admw1001/admw1001_config.h Mon Jan 20 10:40:06 2020 +0000 @@ -58,7 +58,8 @@ #define ADMW1001_SENSOR_COMMAND_MAX_LENGTH 7 /*! ADMW1001 channel priority options */ -typedef enum { +typedef enum +{ ADMW1001_CHANNEL_PRIORITY_0 = 0, ADMW1001_CHANNEL_PRIORITY_1, ADMW1001_CHANNEL_PRIORITY_2, @@ -79,7 +80,8 @@ } ADMW1001_CHANNEL_PRIORITY; /*! ADMW1001 operating mode options */ -typedef enum { +typedef enum +{ ADMW1001_OPERATING_MODE_SINGLECYCLE = 0, /*!< Executes a single measurement cycle and stops */ ADMW1001_OPERATING_MODE_CONTINUOUS, @@ -90,7 +92,8 @@ } ADMW1001_OPERATING_MODE; /*! ADMW1001 data ready mode options */ -typedef enum { +typedef enum +{ ADMW1001_DATAREADY_PER_CONVERSION = 0, /*!< The DATAREADY signal is asserted after completion of each conversion * - a single data sample only from the latest completed conversion is @@ -111,7 +114,8 @@ } ADMW1001_DATAREADY_MODE; /*! ADMW1001 power mode options */ -typedef enum { +typedef enum +{ ADMW1001_POWER_MODE_HIBERNATION = 0, /*!< module has entede hibernation mode. All analog circuitry is disabled. All peripherals disabled apart from the Wake-up pin functionality. */ ADMW1001_POWER_MODE_ACTIVE, @@ -120,7 +124,8 @@ } ADMW1001_POWER_MODE; /*! ADMW1001 measurement analog filter settling options */ -typedef enum { +typedef enum +{ ADMW1001_FILTER_SETTLING_ALWAYS = 0, /*!< Allow full settling time to elapse between every measurement from an analog sensor */ ADMW1001_FILTER_SETTLING_FAST, @@ -133,7 +138,8 @@ * Optionally select a measurement unit for final conversion results. * Currently applicable only to specific temperature sensor types. */ -typedef enum { +typedef enum +{ ADMW1001_MEASUREMENT_UNIT_UNSPECIFIED = 0, /*!< No measurement unit specified */ ADMW1001_MEASUREMENT_UNIT_CELSIUS, @@ -143,30 +149,8 @@ } ADMW1001_MEASUREMENT_UNIT; -/*! ADMW1001 Open-Sensor Diagnostics frequency - * - * Select the per-cycle frequency at which open-sensor diagnostic - * checks should be performed. Open-sensor diagnostic checks typically require - * specific or time-consuming processing which cannot be executed while a - * measurement cycle is running. - * - * @note Open-sensor diagnostic checks, when performed, will add a delay to the - * start of the next measurement cycle. - */ -typedef enum { - ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED = 0, - /*!< No Open-Sensor Detection is performed */ - ADMW1001_OPEN_SENSOR_DIAGNOSTICS_PER_CYCLE, - /*!< No Open-Sensor Detection is performed prior to each cycle */ - ADMW1001_OPEN_SENSOR_DIAGNOSTICS_PER_100_CYCLES, - /*!< No Open-Sensor Detection is performed at intervals of 100 cycles */ - ADMW1001_OPEN_SENSOR_DIAGNOSTICS_PER_1000_CYCLES, - /*!< No Open-Sensor Detection is performed at intervals of 1001 cycles */ - -} ADMW1001_OPEN_SENSOR_DIAGNOSTICS; - - -typedef enum { +typedef enum +{ ADMW1001_BUFFER_BYPASSS_DISABLED = 0, /*!< Buffer Bypass Disabled */ ADMW1001_BUFFER_BYPASSS_ENABLED, @@ -178,7 +162,8 @@ * * @note applicable only to ADC analog sensor channels */ -typedef enum { +typedef enum +{ ADMW1001_ADC_RTD_CURVE_EUROPEAN = 0, /*!< EUROPEAN RTD curve used. */ ADMW1001_ADC_RTD_CURVE_AMERICAN, @@ -193,7 +178,8 @@ * * @note applicable only to ADC analog sensor channels */ -typedef enum { +typedef enum +{ ADMW1001_ADC_GAIN_1X = 0, /*!< no amplification gain */ ADMW1001_ADC_GAIN_2X, @@ -218,11 +204,13 @@ * @note applicable only to ADC analog sensor channels, and * specific sensor types */ -typedef enum { - ADMW1001_ADC_EXC_STATE_CYCLE_POWER=0, +typedef enum +{ + ADMW1001_ADC_EXC_STATE_CYCLE_POWER = 0, /*!< Excitation for measurement is active only during measurement */ ADMW1001_ADC_EXC_STATE_ALWAYS_ON, /*!< Excitation for measurement is always on */ + } ADMW1001_ADC_EXC_STATE; /*! ADMW1001 analog sensor excitation current output level options @@ -230,7 +218,8 @@ * @note applicable only to ADC analog sensor channels, and * specific sensor types */ -typedef enum { +typedef enum +{ ADMW1001_ADC_NO_EXTERNAL_EXC_CURRENT = -1, /*!< NO External excitation is provided */ ADMW1001_ADC_EXC_CURRENT_EXTERNAL = 0, @@ -252,7 +241,8 @@ * * @note applicable only to a diode sensor */ -typedef enum { +typedef enum +{ ADMW1001_ADC_EXC_CURRENT_IOUT_DIODE_10UA_100UA = 0, /**< 2 Current measurement 10uA 100uA */ ADMW1001_ADC_EXC_CURRENT_IOUT_DIODE_20UA_160UA, @@ -277,7 +267,8 @@ * @note applicable only to ADC analog sensor channels, and * specific sensor types */ -typedef enum { +typedef enum +{ ADMW1001_ADC_REFERENCE_VOLTAGE_INTERNAL = 0, /*!< Internal VRef - 1.2V */ ADMW1001_ADC_REFERENCE_VOLTAGE_EXTERNAL_1, @@ -293,7 +284,8 @@ * * @note applicable only to ADC analog sensor channels */ -typedef enum { +typedef enum +{ ADMW1001_ADC_GND_SW_OPEN = 0, /*!< Ground switch not enabled for measurement. */ ADMW1001_ADC_GND_SW_CLOSED, @@ -305,7 +297,8 @@ * * @note applicable only to ADC analog sensor channels */ -typedef enum { +typedef enum +{ ADMW1001_CHOP_MD_NONE = 0, /*!< No chop performed. */ ADMW1001_CHOP_MD_HW, @@ -321,7 +314,8 @@ * * @note applicable only to ADC analog sensor channels */ -typedef enum { +typedef enum +{ ADMW1001_ADC_FILTER_SINC4 = 0, /*!< SINC4 - 4th order sinc response filter */ ADMW1001_ADC_FILTER_SINC3, @@ -335,7 +329,8 @@ * @note SF must be set in conjunction with chop mode * and sinc filter type to achieve the desired sampling rate. */ -typedef enum { +typedef enum +{ ADMW1001_SF_976HZ = 0, /*!< SF setting for 976Hz sample rate. */ ADMW1001_SF_488HZ = 1, @@ -361,7 +356,8 @@ * * @note applicable only for I2C sensors */ -typedef enum { +typedef enum +{ ADMW1001_DIGITAL_SENSOR_COMMS_I2C_CLOCK_SPEED_100K = 0, /*!< 100kHz I2C clock speed */ ADMW1001_DIGITAL_SENSOR_COMMS_I2C_CLOCK_SPEED_400K, @@ -373,7 +369,8 @@ * * @note applicable only for SPI sensors */ -typedef enum { +typedef enum +{ ADMW1001_DIGITAL_SENSOR_COMMS_SPI_MODE_0 = 0, /*!< SPI mode 0 Clock Polarity = 0 Clock Phase = 0 */ ADMW1001_DIGITAL_SENSOR_COMMS_SPI_MODE_1, @@ -389,7 +386,8 @@ * * @note applicable only for SPI sensors */ -typedef enum { +typedef enum +{ ADMW1001_DIGITAL_SENSOR_COMMS_SPI_CLOCK_8MHZ = 0, /*!< SPI Clock Speed configured to 8MHz */ ADMW1001_DIGITAL_SENSOR_COMMS_SPI_CLOCK_4MHZ, @@ -426,7 +424,8 @@ } ADMW1001_DIGITAL_SENSOR_COMMS_SPI_CLOCK; /*! ADMW1001 Power Configuration options */ -typedef struct { +typedef struct +{ ADMW1001_POWER_MODE powerMode; /*!< Power mode selection */ @@ -437,7 +436,8 @@ * @note required only when ADMW1001_OPERATING_MODE_MULTICYCLE is selected * as the operatingMode (@ref ADMW1001_MEASUREMENT_CONFIG) */ -typedef struct { +typedef struct +{ uint32_t cyclesPerBurst; /*!< Number of cycles to complete for a single burst */ uint32_t burstInterval; @@ -446,7 +446,8 @@ } ADMW1001_MULTICYCLE_CONFIG; /*! ADMW1001 Measurement Configuration options */ -typedef struct { +typedef struct +{ ADMW1001_OPERATING_MODE operatingMode; /*!< Operating mode - specifies how measurement cycles are scheduled */ ADMW1001_DATAREADY_MODE dataReadyMode; @@ -463,10 +464,10 @@ * configurations, settling time is always skipped between consecutive * measurements in a measurement cycle. */ - ADMW1001_ADC_EXC_STATE excitationState; + uint8_t excitationState; /*!< Excitation current state */ - ADMW1001_ADC_GND_SW groundSwitch; - /*!< Option to open or close sensor ground switch */ + uint8_t groundSwitch; + /*!< Option to open or close sensor ground switch */ uint8_t reserved0; /*!< Reserved for future use and ensure word alignment. */ @@ -489,7 +490,12 @@ float32_t externalRefVoltage; /*!< External Reference Voltage. */ - uint32_t reserved1[2]; + float32_t AVDDVoltage; + /*!< AVDD Voltage. + */ + uint32_t reserved1[1]; + /*!< Reserved for future use and ensure word alignment. + */ } ADMW1001_MEASUREMENT_CONFIG; @@ -498,11 +504,13 @@ * @note applicable only to ADC analog sensor channels, and * specific sensor types */ -typedef struct { +typedef struct +{ ADMW1001_ADC_EXC_CURRENT outputLevel; /*!< Excitation current output level */ ADMW1001_ADC_EXC_CURRENT_DIODE_RATIO diodeRatio; /*!< Excitation current output diode ratio */ + float32_t idealityRatio; } ADMW1001_ADC_EXC_CURRENT_CONFIG; @@ -510,7 +518,8 @@ * * @note applicable only to ADC analog sensor channels */ -typedef struct { +typedef struct +{ ADMW1001_ADC_FILTER_TYPE type; /*!< Filter type selection */ ADMW1001_SINC_FILTER_RANGE sf; @@ -519,13 +528,15 @@ /*!< Enable filter chop */ bool notch1p2; /*!< Enable Notch 2 Filter Mode */ + } ADMW1001_ADC_FILTER_CONFIG; /*! ADMW1001 ADC analog channel configuration details * * @note applicable only to ADC analog sensor channels */ -typedef struct { +typedef struct +{ ADMW1001_ADC_SENSOR_TYPE sensor; /*!< Sensor type selection */ ADMW1001_ADC_RTD_CURVE rtdCurve; @@ -537,10 +548,9 @@ ADMW1001_ADC_FILTER_CONFIG filter; /*!< ADC Filter configuration */ ADMW1001_ADC_REFERENCE_TYPE reference; - bool vBiasEnable; /*!< ADC Reference configuration */ uint8_t bufferBypass; - /*!< Buffer Bypass configuration */ + /*!< Buffer Bypass configuration */ uint8_t reserved0[2]; /*!< Reserved for future use and ensure word alignment. */ uint32_t reserved1[6]; @@ -551,14 +561,13 @@ /*! ADMW1001 look-up table selection * Select table used to linearise the measurement. */ -typedef enum { +typedef enum +{ ADMW1001_LUT_DEFAULT = 0, /*!< Default LUT */ - ADMW1001_LUT_UNITY = 1, - /*!< Unity LUT */ - ADMW1001_LUT_CUSTOM = 2, + ADMW1001_LUT_CUSTOM = 1, /*!< User defined custom LUT */ - ADMW1001_LUT_RESERVED = 3, + ADMW1001_LUT_RESERVED = 2, /*!< Reserved for future use */ } ADMW1001_LUT_SELECT; @@ -567,7 +576,8 @@ * * @note applicable only to SPI and I2C digital sensor channels */ -typedef enum { +typedef enum +{ ADMW1001_DIGITAL_SENSOR_DATA_CODING_NONE = 0, /**< None/Invalid - data format is ignored if coding is set to this value */ ADMW1001_DIGITAL_SENSOR_DATA_CODING_UNIPOLAR, @@ -584,7 +594,8 @@ * * @note applicable only to SPI and I2C digital sensor channels */ -typedef struct { +typedef struct +{ ADMW1001_DIGITAL_SENSOR_DATA_CODING coding; /**< Data Encoding of Sensor Result */ bool littleEndian; @@ -606,7 +617,8 @@ * * @note applicable only to SPI and I2C digital sensor channels */ -typedef struct { +typedef struct +{ uint8_t command[ADMW1001_SENSOR_COMMAND_MAX_LENGTH]; /*!< Optional command bytes to send to the device */ uint8_t commandLength; @@ -618,7 +630,8 @@ * * @note applicable only to digital sensor channels */ -typedef struct { +typedef struct +{ uint32_t calibrationParam; /*!< Independently established environmental variable used during calibration * of a digital sensor. Used only if the sensor supports calibration @@ -635,7 +648,8 @@ * * @note applicable only to digital sensor channels */ -typedef struct { +typedef struct +{ bool useCustomCommsConfig; /*!< Optional parameter to enable user digital communication settings */ ADMW1001_DIGITAL_SENSOR_COMMS_I2C_CLOCK_SPEED i2cClockSpeed; @@ -651,7 +665,8 @@ * * @note applicable only to I2C digital sensor channels */ -typedef struct { +typedef struct +{ ADMW1001_I2C_SENSOR_TYPE sensor; /*!< Sensor type selection */ uint8_t deviceAddress; @@ -692,7 +707,8 @@ * * @note applicable only to SPI digital sensor channels */ -typedef struct { +typedef struct +{ ADMW1001_SPI_SENSOR_TYPE sensor; /*!< Sensor type selection */ uint8_t reserved[2]; @@ -728,7 +744,8 @@ } ADMW1001_SPI_CHANNEL_CONFIG; /*! ADMW1001 Measurement Channel configuration details */ -typedef struct { +typedef struct +{ bool enableChannel; /*!< Option to include this channel in normal measurement cycles */ bool disablePublishing; @@ -793,7 +810,7 @@ */ uint32_t extraSettlingTime; /*!< A minimum settling time is applied internally for each channel, based - * on the sensor type. However, additional settling time (microseconds) + * on the sensor type. However, additional settling time (milliseconds) * can optionally be specified. Set to 0 if not required. */ ADMW1001_CHANNEL_PRIORITY priority; @@ -805,7 +822,8 @@ * ID. Lower numbers indicate higher priority, with 0 being the highest. * Set to 0 if not required. */ - union { + union + { ADMW1001_ADC_CHANNEL_CONFIG adcChannelConfig; /*!< ADC channel configuration - applicable only to ADC channels */ ADMW1001_I2C_CHANNEL_CONFIG i2cChannelConfig; @@ -821,7 +839,8 @@ } ADMW1001_CHANNEL_CONFIG; /*! ADMW1001 Diagnostics configuration details */ -typedef struct { +typedef struct +{ bool disableGlobalDiag; /*!< Option to disable the following diagnostic checks on the ADC: * - Reference Detection errors @@ -838,7 +857,7 @@ * temperature of the ADMW1001 has exceeded critical limits */ - ADMW1001_OPEN_SENSOR_DIAGNOSTICS osdFrequency; + uint8_t osdFrequency; /*!< Option to enable Open-Circuit Detection at a selected cycle interval */ } ADMW1001_DIAGNOSTICS_CONFIG; @@ -846,7 +865,8 @@ typedef uint16_t ADMW1001_ADVANCED_ACCESS_KEY; /*! ADMW1001 Device configuration details */ -typedef struct { +typedef struct +{ ADMW1001_POWER_CONFIG power; /*!< Power configuration details */ ADMW1001_MEASUREMENT_CONFIG measurement;
--- a/main.cpp Thu Jan 16 06:52:27 2020 +0000 +++ b/main.cpp Mon Jan 20 10:40:06 2020 +0000 @@ -57,7 +57,7 @@ extern ADMW_CONFIG multichannel_singlecycle_config; extern ADMW_CONFIG i2c0_sensirionSHT3X_config; /* Change the following pointer to select any of the configurations above */ -static ADMW_CONFIG *pSelectedConfig = &rtd_4w_config; +static ADMW_CONFIG *pSelectedConfig = &bridge_4w_load_cell_config; static ADMW_CONNECTION connectionInfo = PLATFORM_CONNECTION_INFO;
--- a/multichannel_continuous_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/multichannel_continuous_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -63,7 +63,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = {
--- a/multichannel_singlecycle_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/multichannel_singlecycle_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -61,7 +61,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = {
--- a/rtd_3w_pt100_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/rtd_3w_pt100_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -62,7 +62,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = {
--- a/rtd_4w_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/rtd_4w_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -61,7 +61,6 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = {
--- a/src/admw_1001.c Thu Jan 16 06:52:27 2020 +0000 +++ b/src/admw_1001.c Mon Jan 20 10:40:06 2020 +0000 @@ -1152,6 +1152,15 @@ return ADMW_SUCCESS; } +static ADMW_RESULT admw_SetAVDDVoltage( + ADMW_DEVICE_HANDLE hDevice, + float32_t AVDDVoltage) + { + + WRITE_REG_FLOAT(hDevice, AVDDVoltage, CORE_AVDD_VOLTAGE); + + return ADMW_SUCCESS; + } ADMW_RESULT admw1001_SetMeasurementConfig( ADMW_DEVICE_HANDLE hDevice, @@ -1180,7 +1189,11 @@ eRet = admw_SetExternalReferenceValues(hDevice, pMeasConfig->externalRef1Value); } - + if((pMeasConfig->AVDDVoltage >= 3.0) && (pMeasConfig->AVDDVoltage <= 3.6)) + { + eRet = admw_SetAVDDVoltage(hDevice, + pMeasConfig->AVDDVoltage); + } if (eRet != ADMW_SUCCESS) { ADMW_LOG_ERROR("Failed to set external reference values"); return eRet; @@ -1511,7 +1524,6 @@ switch (pChannelConfig->lutSelect) { case ADMW1001_LUT_DEFAULT: - case ADMW1001_LUT_UNITY: case ADMW1001_LUT_CUSTOM: sensorDetailsReg.LUT_Select = pChannelConfig->lutSelect; break;
--- a/thermocouple_typeJ_cjc0_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/thermocouple_typeJ_cjc0_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -63,7 +63,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = {
--- a/thermocouple_typeK_cjc0_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/thermocouple_typeK_cjc0_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -66,7 +66,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = { @@ -80,7 +80,7 @@ .offsetAdjustment = 0.0, .gainAdjustment = 0.0, .sensorParameter = 0.0, - .measurementsPerCycle = 10, + .measurementsPerCycle = 1, .cycleSkipCount = 0, .extraSettlingTime = 0, .priority = 0, @@ -113,9 +113,9 @@ .offsetAdjustment = 0.0, .gainAdjustment = 0.0, .sensorParameter = 0.0, - .measurementsPerCycle = 10, + .measurementsPerCycle = 1, .cycleSkipCount = 0, - .extraSettlingTime = 4499.99986449257, + .extraSettlingTime = 5, .priority = 0, .adcChannelConfig = { .sensor = ADMW1001_ADC_SENSOR_THERMOCOUPLE_K,
--- a/thermocouple_typeT_cjc0_config.c Thu Jan 16 06:52:27 2020 +0000 +++ b/thermocouple_typeT_cjc0_config.c Mon Jan 20 10:40:06 2020 +0000 @@ -60,7 +60,7 @@ .diagnostics = { .disableGlobalDiag = true, .disableMeasurementDiag = true, - .osdFrequency = ADMW1001_OPEN_SENSOR_DIAGNOSTICS_DISABLED, + .osdFrequency = 0, }, .channels = { [ADMW1001_CH_ID_ANLG_1_UNIVERSAL] = {