A simple example.

Dependencies:   mbed FastIO

You are viewing an older revision! See the latest version

Homepage

How does it work?

Oversampling

The core loop of the sampling does only one thing: it continuously looks at the input pin and increments a counter. Only when the input toggles, the counter value is used as an index and the histogram is updated and the counter is reset. By doing so the histogram will contain the run length of observed zeroes or ones, expressed in the time grid of the sampler. For a 1MHz bit stream the LPC 1768 should be capable to over sample approximately four times.

Grouping of run length

A filled histogram of run lengths, of both the zero and one symbols, will contain groups of adjacent run lengths values separated by empty spaces. If the sigma delta is connected to an analog voltage at exactly 33.33% of the range, the output pattern of the bit stream, expressed in the time grid of the ADC, will be close to 001001001001... With approximately four times oversampling the LPC board may capture a data stream like: 0000000111100000000111000000000111100000000111, or expressed in run lengths: 7, 4, 8, 3, 9, 4, 8, 3. The histogram of zeroes will be filled with 1, 2 and 1 at position 7, 8 and 9, while the histogram of ones will be filled with 2 and 2 at position 3 and 4.

Assign values to groups

After captured the data, the histogram will be scanned for groups of adjacent run lengths. A begin and end pointer/index of each will be stored in object type "Recovered". Once the whole histogram is scanned, a list of run length groups is determined.

Calculate Over Sample Ratio and Offset

Known limitations

  • The amount of samples is only approximated, or more accurate, taken as a minimum value. As only the counter is compared once a complete run length of the same symbols is seen, it will be always slightly above the require value.
  • The amount of samples taken is hard coded. No means to vary this while running the application.
  • When the ADC input is very close or the maximum input voltage (or very close tot the minimum input voltage) the resulting bit stream will contain mostly very long run length of one's and hardly any zero (or vice versa). As no clock is connected, the stream may become out of synchronization for these cases.
  • Only the DC level is calculated, as a sum of all ones divided by the amount of symbols. Technically one could add Fourier transform in the post-processing and calculate SNR, THD, SINAD, ENOB etc, This requires another data structure of the histogram: store run length in the sequence they appear.
  • The algorithm works only correct given two assumptions. There should be exactly one group of empty spaces between two groups of captured run lengths (each representing a different bit stream run length). And each group of run lengths may not contain any empty position. Another decoder http://en.wikipedia.org/wiki/Viterbi_algorithm would possibly do better and even could estimate a qualification number.