Simple Mbed Cloud Client application using features of K64 & K66
Connect to Mbed Cloud!
This example was customized a bit for FRDM-K66 and FRDM-K64F.
It depends on having an SD Card plugged in for storage of credentials. It could be changed later to use a SPI flash or other storage on a shield or wired in.
The app keeps track of how many times switch 2 (SW2) is pressed. The value can be retrieved via a GET request to Mbed Cloud.
Also, it will blink a pattern based on milisecond (ms) timing values that can be sent from Mbed Cloud. The pattern can be sent with a PUT request and the blinking sequence can be triggered by a POST request.
Diff: mbed_app.json
- Revision:
- 13:49062a0d117e
- Parent:
- 12:0a894bf1f5f2
- Child:
- 14:10b59d30bf7e
diff -r 0a894bf1f5f2 -r 49062a0d117e mbed_app.json
--- a/mbed_app.json Fri May 18 21:28:25 2018 +0000
+++ b/mbed_app.json Fri Oct 05 13:11:30 2018 -0500
@@ -5,7 +5,7 @@
"MBED_CLIENT_USER_CONFIG_FILE=\"mbed_cloud_client_user_config.h\"",
"MBED_CLOUD_CLIENT_USER_CONFIG_FILE=\"mbed_cloud_client_user_config.h\"",
"PAL_DTLS_PEER_MIN_TIMEOUT=5000",
- "MBED_CONF_APP_MAIN_STACK_SIZE=4608",
+ "MBED_CONF_APP_MAIN_STACK_SIZE=6000",
"ARM_UC_USE_PAL_BLOCKDEVICE=1",
"MBED_CLOUD_CLIENT_UPDATE_STORAGE=ARM_UCP_FLASHIAP_BLOCKDEVICE"
],
@@ -19,20 +19,23 @@
"mbed-trace.enable": null
},
"K64F": {
- "sotp-section-1-address" : "0xFE000",
- "sotp-section-1-size" : "0x1000",
- "sotp-section-2-address" : "0xFF000",
- "sotp-section-2-size" : "0x1000",
- "sotp-num-sections" : 2
+ "target.features_add" : ["BOOTLOADER"],
+ "sotp-section-1-address" : "(32*1024)",
+ "sotp-section-1-size" : "(4*1024)",
+ "sotp-section-2-address" : "(36*1024)",
+ "sotp-section-2-size" : "(4*1024)",
+ "sotp-num-sections" : 2,
+ "update-client.application-details": "(40*1024)"
},
"K66F": {
- "sotp-section-1-address" : "0x1FE000",
- "sotp-section-1-size" : "0x1000",
- "sotp-section-2-address" : "0x1FF000",
- "sotp-section-2-size" : "0x1000",
- "sotp-num-sections" : 2
+ "target.features_add" : ["BOOTLOADER"],
+ "sotp-section-1-address" : "(32*1024)",
+ "sotp-section-1-size" : "(4*1024)",
+ "sotp-section-2-address" : "(36*1024)",
+ "sotp-section-2-size" : "(4*1024)",
+ "sotp-num-sections" : 2,
+ "update-client.application-details": "(40*1024)"
}
-
},
"config": {
"format-storage-layer-on-error": {
@@ -43,7 +46,6 @@
"help": "Enable Developer mode to skip Factory enrollment",
"value": 1
},
-
"sotp-section-1-address": {
"help": "Flash sector address for SOTP sector 1",
"macro_name": "PAL_INTERNAL_FLASH_SECTION_1_ADDRESS",