This program simply connects to a HTS221 I2C device to proximity sensor

Dependencies:   FXOS8700CQ mbed

Committer:
elmkom
Date:
Mon Oct 10 16:29:34 2016 +0000
Revision:
43:3979ea0a2df3
Parent:
42:8500f0cb2ea5
Flush modem buffer before send

Who changed what in which revision?

UserRevisionLine numberNew contents of line
JMF 2:0e2ef866af95 1 #ifndef __CONFIG_ME_H_
JMF 2:0e2ef866af95 2 #define __CONFIG_ME_H_
JMF 2:0e2ef866af95 3
JMF 2:0e2ef866af95 4 // User must set these for own context:
fkellermavnet 21:d0038d14ee7c 5
fkellermavnet 21:d0038d14ee7c 6 // This is the server's base URL name. Example "www.google.com"
stefanrousseau 24:bd480d2aade4 7 // Note that when you Fork a FLOW, it will typically assign either
stefanrousseau 24:bd480d2aade4 8 // "run-east.att.io" or "run-west.att.io", so be sure to check this.
elmkom 41:85a736a9b900 9 //static const char * MY_SERVER_URL = "run-east.att.io";
elmkom 41:85a736a9b900 10 static const char * MY_SERVER_URL = "108.244.165.22";
stefanrousseau 24:bd480d2aade4 11 // These are FLOW fields from the Endpoints tab:
elmkom 41:85a736a9b900 12 //#define FLOW_BASE_URL "/a80556051c438/f4cd2ed65f73/7ecb40fcd115f7a/in/flow"
elmkom 41:85a736a9b900 13 //#define FLOW_INPUT_NAME "/shelf"
elmkom 41:85a736a9b900 14 #define FLOW_BASE_URL ""
elmkom 35:2e864bae3af0 15 #define FLOW_INPUT_NAME "/shelf"
stefanrousseau 24:bd480d2aade4 16 // Unless you want to use a different protocol, this field should be left as is:
stefanrousseau 12:7c94ec5069dc 17 #define FLOW_URL_TYPE " HTTP/1.1\r\nHost: "
stefanrousseau 12:7c94ec5069dc 18
stefanrousseau 24:bd480d2aade4 19 // This identifier specifies with which FLOW device you are communicating.
stefanrousseau 24:bd480d2aade4 20 // If you only have one devive there then you can just leave this as is.
stefanrousseau 24:bd480d2aade4 21 // Once your FLOW device has been initialized (Virtual Device Initialize clicked),
stefanrousseau 24:bd480d2aade4 22 // the Virtual Device will show up in M2X. This is its "DEVICE SERIAL" field
fkellermavnet 21:d0038d14ee7c 23 #define FLOW_DEVICE_NAME "vstarterkit001"
fkellermavnet 21:d0038d14ee7c 24
stefanrousseau 24:bd480d2aade4 25 // This constant defines how often sensors are read and sent up to FLOW
stefanrousseau 24:bd480d2aade4 26 #define SENSOR_UPDATE_INTERVAL_MS 5000; //5 seconds
stefanrousseau 24:bd480d2aade4 27
stefanrousseau 24:bd480d2aade4 28 // Specify here how many sensor parameters you want reported to FLOW.
stefanrousseau 24:bd480d2aade4 29 // You can use only the temperature and humidity from the shield HTS221
stefanrousseau 24:bd480d2aade4 30 // or you can add the reading of the FXO8700CQ motion sensor on the FRDM-K64F board
stefanrousseau 24:bd480d2aade4 31 // or if you have a SiLabs PMOD plugged into the shield, you can add its proximity sensor,
stefanrousseau 24:bd480d2aade4 32 // UV light, visible ambient light and infrared ambient light readings
stefanrousseau 12:7c94ec5069dc 33 #define TEMP_HUMIDITY_ONLY 1
stefanrousseau 12:7c94ec5069dc 34 #define TEMP_HUMIDITY_ACCELEROMETER 2
stefanrousseau 12:7c94ec5069dc 35 #define TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS 3
elmkom 38:532a0d929756 36 #define PROXIMITY_ONLY 4
elmkom 41:85a736a9b900 37 #define SWITCH_ONLY 5
elmkom 38:532a0d929756 38 static int iSensorsToReport = PROXIMITY_ONLY; //TEMP_HUMIDITY_ONLY; //modify this to change your selection
stefanrousseau 12:7c94ec5069dc 39
fkellermavnet 21:d0038d14ee7c 40 // This is the APN name for the cellular network, you will need to change this, check the instructions included with your SIM card kit:
elmkom 42:8500f0cb2ea5 41 #define MY_APN_STR "m2m.com.attz"
fkellermavnet 21:d0038d14ee7c 42
fkellermavnet 21:d0038d14ee7c 43 //This is for normal HTTP. If you want to use TCP to a specific port, change that here:
elmkom 41:85a736a9b900 44 static const char * MY_PORT_STR = "5005";
JMF 2:0e2ef866af95 45
JMF 2:0e2ef866af95 46 #endif