Vybhav Kadaba
/
EV-PRO-MW1001_Development_MWARE2390
sensor result structure modified
mbed_release.txt@71:7b5ebd969aa7, 2020-04-23 (annotated)
- Committer:
- Vkadaba
- Date:
- Thu Apr 23 08:34:45 2020 +0000
- Revision:
- 71:7b5ebd969aa7
- Parent:
- 67:d36977cbfe90
Adding extra log for FIFI error
Who changed what in which revision?
User | Revision | Line number | New contents of line |
---|---|---|---|
Vkadaba | 55:215da406282b | 1 | ================================================================================ |
Vkadaba | 67:d36977cbfe90 | 2 | = Mbed Host Firmware = |
Vkadaba | 55:215da406282b | 3 | = = |
Vkadaba | 55:215da406282b | 4 | = Release notes = |
Vkadaba | 55:215da406282b | 5 | ================================================================================ |
Vkadaba | 67:d36977cbfe90 | 6 | ================================================================================ |
Vkadaba | 67:d36977cbfe90 | 7 | v01.17.0075 (20 April 2020) |
Vkadaba | 67:d36977cbfe90 | 8 | -------------------------------------------------------------------------------- |
Vkadaba | 67:d36977cbfe90 | 9 | - Removed CRC field in LUT |
Vkadaba | 67:d36977cbfe90 | 10 | - Adding 31us delay between wakeup signal and SPI's CS signal |
Vkadaba | 67:d36977cbfe90 | 11 | - Code clean up |
Vkadaba | 67:d36977cbfe90 | 12 | - Handling FIFO error |
Vkadaba | 55:215da406282b | 13 | ================================================================================ |
Vkadaba | 57:c6275de14bc5 | 14 | v01.02.0003 (6 March 2020) |
Vkadaba | 57:c6275de14bc5 | 15 | -------------------------------------------------------------------------------- |
Vkadaba | 57:c6275de14bc5 | 16 | - SPI malfunctions after hibernation |
Vkadaba | 57:c6275de14bc5 | 17 | - SPI frequency set to 1MHz |
Vkadaba | 57:c6275de14bc5 | 18 | ================================================================================ |
Vkadaba | 57:c6275de14bc5 | 19 | v01.02.0002 (25 February 2020) |
Vkadaba | 55:215da406282b | 20 | -------------------------------------------------------------------------------- |
Vkadaba | 55:215da406282b | 21 | - Added support to load Look up table |
Vkadaba | 55:215da406282b | 22 | - Printing correct Raw values from the sensor |
Vkadaba | 55:215da406282b | 23 | - Added funcionality to read the Mbed FW version |
Vkadaba | 55:215da406282b | 24 | - Added release notes |
Vkadaba | 56:38b36e947602 | 25 | - updated all the config files |
Vkadaba | 55:215da406282b | 26 | ================================================================================ |
Vkadaba | 55:215da406282b | 27 | |
Vkadaba | 55:215da406282b | 28 | v01.01.0001 (18 February 2020) |
Vkadaba | 55:215da406282b | 29 | -------------------------------------------------------------------------------- |
Vkadaba | 55:215da406282b | 30 | - Changed ADMW_CONFIG struct variable name to "meassureware_config" inroder to load the config/design file downloaded from MW designer |
Vkadaba | 55:215da406282b | 31 | - Added wakeup functinality support. |
Vkadaba | 55:215da406282b | 32 | - Added support for ADT7420 |
Vkadaba | 55:215da406282b | 33 | - Added support for DRDY_PER_FIFO_FILL mode |
Vkadaba | 55:215da406282b | 34 | - Supporting the the Device FW v1.12.061 |
Vkadaba | 55:215da406282b | 35 | ================================================================================ |