INSAT Mini Project

Dependencies:   ST_INTERFACES X_NUCLEO_COMMON

Fork of X_NUCLEO_6180XA1 by ST

Committer:
gallonm
Date:
Mon Nov 02 14:02:53 2015 +0100
Revision:
24:025afc3fe30f
Parent:
22:1a6327e9a7e6
Child:
33:1573db91352c
Modified file cfg.h by introducing #define EXTENDED_RANGE_50CM.
Settled StartMeasurement by removing MeasureData_t from parameters.
Settled range single shot measure and als single shot measure.
Settled GetMeasurement by introducing range_single_shot case and als_single_shot case.
Settled VL6180x_AlsSetThresholds by introducing the computation in order to pass
the arguments in lux and write the same arguments in raw device value into registers.

Who changed what in which revision?

UserRevisionLine numberNew contents of line
gallonm 1:1de1ea2994d9 1 /*******************************************************************************
gallonm 1:1de1ea2994d9 2 Copyright © 2014, STMicroelectronics International N.V.
gallonm 1:1de1ea2994d9 3 All rights reserved.
gallonm 1:1de1ea2994d9 4
gallonm 1:1de1ea2994d9 5 Redistribution and use in source and binary forms, with or without
gallonm 1:1de1ea2994d9 6 modification, are permitted provided that the following conditions are met:
gallonm 1:1de1ea2994d9 7 * Redistributions of source code must retain the above copyright
gallonm 1:1de1ea2994d9 8 notice, this list of conditions and the following disclaimer.
gallonm 1:1de1ea2994d9 9 * Redistributions in binary form must reproduce the above copyright
gallonm 1:1de1ea2994d9 10 notice, this list of conditions and the following disclaimer in the
gallonm 1:1de1ea2994d9 11 documentation and/or other materials provided with the distribution.
gallonm 1:1de1ea2994d9 12 * Neither the name of STMicroelectronics nor the
gallonm 1:1de1ea2994d9 13 names of its contributors may be used to endorse or promote products
gallonm 1:1de1ea2994d9 14 derived from this software without specific prior written permission.
gallonm 1:1de1ea2994d9 15
gallonm 1:1de1ea2994d9 16 THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
gallonm 1:1de1ea2994d9 17 ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
gallonm 1:1de1ea2994d9 18 WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND
gallonm 1:1de1ea2994d9 19 NON-INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS ARE DISCLAIMED.
gallonm 1:1de1ea2994d9 20 IN NO EVENT SHALL STMICROELECTRONICS INTERNATIONAL N.V. BE LIABLE FOR ANY
gallonm 1:1de1ea2994d9 21 DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
gallonm 1:1de1ea2994d9 22 (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
gallonm 1:1de1ea2994d9 23 LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND
gallonm 1:1de1ea2994d9 24 ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
gallonm 1:1de1ea2994d9 25 (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
gallonm 1:1de1ea2994d9 26 SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
gallonm 1:1de1ea2994d9 27 ********************************************************************************/
gallonm 1:1de1ea2994d9 28 /*
gallonm 1:1de1ea2994d9 29 * $Date: 2015-01-08 14:35:34 +0100 (Thu, 08 Jan 2015) $
gallonm 1:1de1ea2994d9 30 * $Revision: 2042 $
gallonm 1:1de1ea2994d9 31 */
gallonm 1:1de1ea2994d9 32
gallonm 1:1de1ea2994d9 33 /**
gallonm 1:1de1ea2994d9 34 * @file VL6180x_cfg.h
gallonm 1:1de1ea2994d9 35 *
gallonm 1:1de1ea2994d9 36 * Proximity and ALS configuration
gallonm 1:1de1ea2994d9 37 */
gallonm 1:1de1ea2994d9 38
gallonm 1:1de1ea2994d9 39 #ifndef VL6180x_CFG_H_
gallonm 1:1de1ea2994d9 40 #define VL6180x_CFG_H_
gallonm 1:1de1ea2994d9 41
gallonm 1:1de1ea2994d9 42 /** @defgroup api_config Configuration
gallonm 1:1de1ea2994d9 43 * @brief API static configuration
gallonm 1:1de1ea2994d9 44 */
gallonm 1:1de1ea2994d9 45
gallonm 1:1de1ea2994d9 46
gallonm 1:1de1ea2994d9 47
gallonm 1:1de1ea2994d9 48 /** @ingroup api_config
gallonm 1:1de1ea2994d9 49 * @{*/
gallonm 1:1de1ea2994d9 50
gallonm 1:1de1ea2994d9 51
gallonm 1:1de1ea2994d9 52 /**
gallonm 1:1de1ea2994d9 53 * @def VL6180x_UPSCALE_SUPPORT
gallonm 1:1de1ea2994d9 54 * @brief Configure up-scale capabilities and default up-scale factor for ranging operations
gallonm 1:1de1ea2994d9 55 *
gallonm 1:1de1ea2994d9 56 * @li 1 : Fixed scaling by 1 (no up-scaling support)
gallonm 1:1de1ea2994d9 57 * @li 2 : Fixed scaling by 2
gallonm 1:1de1ea2994d9 58 * @li 3 : Fixed scaling by 3
gallonm 1:1de1ea2994d9 59 * @li -1 -2 -3 : Run time programmable through @a VL6180x_UpscaleSetScaling(). Default scaling factore is -VL6180x_UPSCALE_SUPPORT \n
gallonm 1:1de1ea2994d9 60 */
gallonm 24:025afc3fe30f 61 //#define VL6180x_UPSCALE_SUPPORT -1
gallonm 1:1de1ea2994d9 62
gallonm 1:1de1ea2994d9 63 /**
gallonm 1:1de1ea2994d9 64 * @def VL6180x_ALS_SUPPORT
gallonm 1:1de1ea2994d9 65 * @brief Enable ALS support
gallonm 1:1de1ea2994d9 66 *
gallonm 1:1de1ea2994d9 67 * Set to 0 if ALS is not used in application. This can help reducing code size if it is a concern.
gallonm 1:1de1ea2994d9 68 */
gallonm 1:1de1ea2994d9 69 #define VL6180x_ALS_SUPPORT 1
gallonm 1:1de1ea2994d9 70
gallonm 1:1de1ea2994d9 71 /**
gallonm 1:1de1ea2994d9 72 * @def VL6180x_HAVE_DMAX_RANGING
gallonm 1:1de1ea2994d9 73 * @brief Enable DMax calculation for ranging applications.
gallonm 1:1de1ea2994d9 74 *
gallonm 1:1de1ea2994d9 75 * When set to 1, __Dmax__ is returned by API typically when @a VL6180x_RangePollMeasurement() high level
gallonm 1:1de1ea2994d9 76 * function is called (this is returned in @a VL6180x_RangeData_t structure).
gallonm 1:1de1ea2994d9 77 * __Dmax__ is an estimation of the maximum distance (in mm) the product can report a valid distance of a 17% target for
gallonm 1:1de1ea2994d9 78 * the current ambient light conditions (__Dmax__ decreases when ambient light increases). __Dmax__ should be used only
gallonm 1:1de1ea2994d9 79 * when the product is not able to return a valid distance (no object or object is too far from the ranging sensor).
gallonm 1:1de1ea2994d9 80 * Typically, this is done by checking the __errorStatus__ field of the @a VL6180x_RangeData_t structure returned by
gallonm 1:1de1ea2994d9 81 * the @a VL6180x_RangePollMeasurement() function.
gallonm 1:1de1ea2994d9 82 * You may refer to ::RangeError_u to get full list of supported error codes.
gallonm 1:1de1ea2994d9 83 * @warning Dmax is estimated for a 17% grey target. If the real target has a reflectance lower than 17%, report Dmax could be over-estimated
gallonm 1:1de1ea2994d9 84 */
gallonm 1:1de1ea2994d9 85 #define VL6180x_HAVE_DMAX_RANGING 1
gallonm 1:1de1ea2994d9 86
gallonm 1:1de1ea2994d9 87 /**
gallonm 1:1de1ea2994d9 88 * @def VL6180x_WRAP_AROUND_FILTER_SUPPORT
gallonm 1:1de1ea2994d9 89 * @brief Enable wrap around filter (WAF) feature
gallonm 1:1de1ea2994d9 90 *
gallonm 1:1de1ea2994d9 91 * In specific conditions, when targeting a mirror or a very reflective metal, a __wrap around__ effect can occur internally to the
gallonm 1:1de1ea2994d9 92 * ranging product which results in returning a wrong distance (under-estimated). Goal of the WAF is to detect this wrap arround effect
gallonm 1:1de1ea2994d9 93 * and to filter it by returning a non-valid distance : __errorStatus__ set to 16 (see ::RangeError_u)
gallonm 1:1de1ea2994d9 94 * @warning Wrap-around filter can not be used when device is running in continuous mode
gallonm 1:1de1ea2994d9 95 *
gallonm 1:1de1ea2994d9 96 * @li 0 : Filter is not supported, no filtering code is included in API
gallonm 1:1de1ea2994d9 97 * @li 1 : Filter is supported and active by default
gallonm 1:1de1ea2994d9 98 * @li -1 : Filter is supported but is not active by default @a VL6180x_FilterSetState() can turn it on and off at any time
gallonm 1:1de1ea2994d9 99 */
gallonm 1:1de1ea2994d9 100 #define VL6180x_WRAP_AROUND_FILTER_SUPPORT 1
gallonm 1:1de1ea2994d9 101
gallonm 1:1de1ea2994d9 102 /**
gallonm 1:1de1ea2994d9 103 * @def VL6180x_EXTENDED_RANGE
gallonm 1:1de1ea2994d9 104 * @brief Enable extended ranging support
gallonm 1:1de1ea2994d9 105 *
gallonm 1:1de1ea2994d9 106 * Device that do not formally support extended ranging should only be used with a scaling factor of 1.
gallonm 1:1de1ea2994d9 107 * Correct operation with scaling factor other than 1 (>200mm ) is not granted by ST.
gallonm 1:1de1ea2994d9 108 */
gallonm 24:025afc3fe30f 109 //#define VL6180x_EXTENDED_RANGE 0
gallonm 24:025afc3fe30f 110
gallonm 24:025afc3fe30f 111 #define EXTENDED_RANGE_50CM 0
gallonm 1:1de1ea2994d9 112
gallonm 24:025afc3fe30f 113 #if EXTENDED_RANGE_50CM
gallonm 24:025afc3fe30f 114 #define VL6180x_UPSCALE_SUPPORT -3
gallonm 24:025afc3fe30f 115 #define VL6180x_EXTENDED_RANGE 1
gallonm 24:025afc3fe30f 116 #else
gallonm 24:025afc3fe30f 117 #define VL6180x_UPSCALE_SUPPORT -1
gallonm 24:025afc3fe30f 118 #define VL6180x_EXTENDED_RANGE 0
gallonm 24:025afc3fe30f 119 #endif
gallonm 1:1de1ea2994d9 120
gallonm 1:1de1ea2994d9 121 #if (VL6180x_EXTENDED_RANGE) && (VL6180x_ALS_SUPPORT)
gallonm 1:1de1ea2994d9 122 #warning "Als support should be OFF for extended range"
gallonm 1:1de1ea2994d9 123 #endif
gallonm 1:1de1ea2994d9 124
gallonm 1:1de1ea2994d9 125 #endif
gallonm 1:1de1ea2994d9 126 /** @} */ // end of api_config
gallonm 1:1de1ea2994d9 127
gallonm 1:1de1ea2994d9 128 /* VL6180x_CFG_H_ */