CCS811 dumb library
Dependents: Mt05_MtSense02 embernet-sensor-test
CCS811.h
- Committer:
- johnathanlyu
- Date:
- 2017-06-27
- Revision:
- 0:b5dbfc21185d
- Child:
- 1:57eb62ded32d
File content as of revision 0:b5dbfc21185d:
#ifndef CCS811_H #define CCS811_H //CCS811 register define #define CCS811_I2C_ADDR 0xB4 #define CCS811_REG_STATUS 0x00 //Status. #define CCS811_REG_MEAS_MODE 0x01 //Mesurement mode and conditions register. #define CCS811_REG_ALG_RESULT_DATA 0x02 //Algorithm result. 2 bytes co2 ppm next 2 bytes ppb VOC level. #define CCS811_REG_RAW_DATA 0x03 //Raw ADC data. #define CCS811_REG_ENV_DATA 0x05 //Temperature and humidity data can be write to enavle compensation. #define CCS811_REG_NTC 0x06 //Provides the voltage across the reference registor and the voltage across the NTC resistor. #define CCS811_REG_THRESHOLDS 0x10 //Thresholds for operation when interrupts are only generated when eCO2 ppm crosses a threshold. #define CCS811_REG_BASELINE 0x11 //The encoded current baseline value can be read.A previously saved encoded baseline can be written. #define CCS811_REG_HW_ID 0x20 //Hardware ID. The value is 0x81. #define CCS811_REG_HW_VERSION 0x21 //Hardware version. The value is 0x1X. #define CCS811_REG_BOOT_VERSION 0x23 //Firmware boot version. The First 2 bytes contain the firmware version number for the boot code. #define CCS811_REG_APP_VERSION 0x24 //Firmware application version. The first 2 bytes contain the firmware version number for the application code. #define CCS811_REG_ERROR_ID 0xE0 //Error ID. When the status register reports and error its source is lcated in this register. #define CCS811_REG_APP_START 0xF4 //Application start. Used to transition the CCS811 state from boot to application mode, a write with no data is required. Before performing a write to APP_START the Status register should be accessed to check if there is a valid application present. #define CCS811_REG_SW_RESET 0xFF //If the correct 4 byres (0x11, 0xE5, 0x72, 0x8A)are written to this register in a single sequence the device will reset and return to BOOT bode. //mode setting #define CCS811_MEASUREMENT_MODE0 0x00 //Idle(Measurements are disabled in this mode). #define CCS811_MEASUREMENT_MODE1 0x10 //Constant power mode, IAQ measurement every second. #define CCS811_MEASUREMENT_MODE2 0x20 //Pulse heating mode IAQ measurement every 10 seconds. #define CCS811_MEASUREMENT_MODE3 0x30 //Low power pulse heating mode IAQ measurement every 60 seconds. #define CCS811_MEASUREMENT_MODE4 0x40 //Constant power mode, sensor measurement every 250ms. 1xx: Reserved modes (For future use). //Interrupt control #define CCS811_INT_DATARDY 0x08 //At the end of each measurement cycle (250ms, 1s, 10s, 60s) a flag is set in the STATUS register regardless of the setting of this bit. #define CCS811_INT_THRESH 0x04 //0: Interrupt mode (if enabled) operates normally 1: Interrupt mode (if enabled) only asserts the nINT signal (driven low) if the new ALG_RESULT_DATA crosses one of the thresholds set in the THRESHOLDS register by more than the hysteresis value (also in the THRESHOLDS register). #include "mbed.h" class CCS811 { public: CCS811(I2C& i2c); void init(); int setMeasureMode(char mode); int readData(uint16_t *ECO2, uint16_t *TVOC); bool checkHW(); bool softRest(); protected: I2C m_i2c; Serial pc; private: }; #endif