MBED library software for the MAX30001 ECG, PACE, biopotential, bioimpedance, R-to-R peak sensor.
Dependencies: USBDevice max32630fthr SDFileSystem
Fork of MAX30001-MAX32630FTHR-ECG-EVKIT by
Diff: HSP/Test/Test_MAX30001.cpp
- Revision:
- 21:a789ee91137e
- Parent:
- 20:1151a3095605
- Child:
- 22:17aab62c9efa
diff -r 1151a3095605 -r a789ee91137e HSP/Test/Test_MAX30001.cpp
--- a/HSP/Test/Test_MAX30001.cpp Mon Jul 09 17:47:25 2018 +0300
+++ /dev/null Thu Jan 01 00:00:00 1970 +0000
@@ -1,170 +0,0 @@
-/*******************************************************************************
- * Copyright (C) 2016 Maxim Integrated Products, Inc., All Rights Reserved.
- *
- * Permission is hereby granted, free of charge, to any person obtaining a
- * copy of this software and associated documentation files (the "Software"),
- * to deal in the Software without restriction, including without limitation
- * the rights to use, copy, modify, merge, publish, distribute, sublicense,
- * and/or sell copies of the Software, and to permit persons to whom the
- * Software is furnished to do so, subject to the following conditions:
- *
- * The above copyright notice and this permission notice shall be included
- * in all copies or substantial portions of the Software.
- *
- * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS
- * OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
- * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT.
- * IN NO EVENT SHALL MAXIM INTEGRATED BE LIABLE FOR ANY CLAIM, DAMAGES
- * OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE,
- * ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
- * OTHER DEALINGS IN THE SOFTWARE.
- *
- * Except as contained in this notice, the name of Maxim Integrated
- * Products, Inc. shall not be used except as stated in the Maxim Integrated
- * Products, Inc. Branding Policy.
- *
- * The mere transfer of this software does not imply any licenses
- * of trade secrets, proprietary technology, copyrights, patents,
- * trademarks, maskwork rights, or any other form of intellectual
- * property whatsoever. Maxim Integrated Products, Inc. retains all
- * ownership rights.
- *******************************************************************************
- */
-#include "Test_MAX30001.h"
-#include "Test_Utilities.h"
-
-uint32_t testing_max30001 = 0;
-uint32_t testing_ecg_flags[4];
-
-//******************************************************************************
-void test_MAX30001(void (*outputString)(const char *)) {
- int totalPass = 1;
- int pass;
- uint32_t foundEcg = 0;
- uint32_t foundBioz = 0;
- uint32_t foundPace = 0;
- uint32_t foundRtoR = 0;
- uint32_t id;
- char str2[128];
- int partVersion; // 0 = 30004
- // 1 = 30001
- // 2 = 30002
- // 3 = 30003
- Timer timer;
- MAX30001 *max30001;
- max30001 = Peripherals::max30001();
-
- // read the id
- max30001->max30001_reg_read(MAX30001::INFO, &id);
- // read id twice because it needs to be read twice
- max30001->max30001_reg_read(MAX30001::INFO, &id);
- partVersion = id >> 12;
- partVersion = partVersion & 0x3;
-
- // display header
- if (partVersion == 0)
- outputString("Testing MAX30004|");
- if (partVersion == 1) {
- outputString("Testing MAX30001|");
- outputString("Testing ECG, RtoR, BioZ, PACE|");
- }
- if (partVersion == 2)
- outputString("Testing MAX30002|");
- if (partVersion == 3) {
- outputString("Testing MAX30003|");
- outputString("Only Testing ECG and RtoR|");
- }
- sprintf(str2, "Device ID = 0x%06X|", id);
- outputString(str2);
-
- // clear testing flags
- testing_ecg_flags[TESTING_ECG_FLAG] = 0;
- testing_ecg_flags[TESTING_BIOZ_FLAG] = 0;
- testing_ecg_flags[TESTING_PACE_FLAG] = 0;
- testing_ecg_flags[TESTING_RTOR_FLAG] = 0;
-
- // start streams
- testing_max30001 = 1;
- if (partVersion == 1)
- outputString("Start Streaming ECG, RtoR, PACE, BIOZ, CAL enabled, "
- "verifying streams...|");
- if (partVersion == 3)
- outputString(
- "Start Streaming ECG, RtoR, CAL enabled, verifying streams...|");
- // max30001_CAL_InitStart(0b1, 0b1, 0b1, 0b011, 0x7FF, 0b0);
- max30001->max30001_CAL_InitStart(0b1, 0b1, 0b1, 0b011, 0x7FF, 0b0);
- max30001->max30001_ECG_InitStart(0b1, 0b1, 0b1, 0b0, 0b10, 0b11, 0x1F, 0b00,
- 0b00, 0b0, 0b01);
- if (partVersion == 1)
- max30001->max30001_PACE_InitStart(0b1, 0b0, 0b0, 0b1, 0x0, 0b0, 0b00, 0b0,
- 0b0);
- if (partVersion == 1)
- max30001->max30001_BIOZ_InitStart(0b1, 0b1, 0b1, 0b10, 0b11, 0b00, 7, 0b0,
- 0b010, 0b0, 0b10, 0b00, 0b00, 2, 0b0,
- 0b111, 0b0000, 0b0000);
- max30001->max30001_RtoR_InitStart(0b1, 0b0011, 0b1111, 0b00, 0b0011, 0b000001,
- 0b00, 0b000, 0b01);
- max30001->max30001_Rbias_FMSTR_Init(0b01, 0b10, 0b1, 0b1, 0b00);
- max30001->max30001_synch();
-
- // look for each stream
- timer.start();
- while (1) {
- if ((foundEcg == 0) && (testing_ecg_flags[TESTING_ECG_FLAG] == 1)) {
- foundEcg = 1;
- outputString("ECG Stream: PASS|");
- }
- if ((foundBioz == 0) && (testing_ecg_flags[TESTING_BIOZ_FLAG] == 1)) {
- foundBioz = 1;
- outputString("Bioz Stream: PASS|");
- }
- if ((foundPace == 0) && (testing_ecg_flags[TESTING_PACE_FLAG] == 1)) {
- foundPace = 1;
- outputString("PACE Stream: PASS|");
- }
- if ((foundRtoR == 0) && (testing_ecg_flags[TESTING_RTOR_FLAG] == 1)) {
- foundRtoR = 1;
- outputString("RtoR Stream: PASS|");
- }
- if ((foundEcg == 1) && (foundBioz == 1) && (foundPace == 1) &&
- (foundRtoR == 1) && (partVersion == 1)) {
- break;
- }
- if ((foundEcg == 1) && (foundRtoR == 1) && (partVersion == 3)) {
- break;
- }
- if (timer.read() >= TESTING_MAX30001_TIMEOUT_SECONDS) {
- break;
- }
- }
- timer.stop();
- if (foundEcg == 0) {
- outputString("ECG Stream: FAIL|");
- totalPass &= pass;
- }
- if ((foundBioz == 0) && (partVersion == 1)) {
- outputString("Bioz Stream: FAIL|");
- totalPass &= pass;
- }
- if ((foundPace == 0) && (partVersion == 1)) {
- outputString("PACE Stream: FAIL|");
- totalPass &= pass;
- }
- if (foundRtoR == 0) {
- outputString("RtoR Stream: FAIL|");
- totalPass &= pass;
- }
-
- // stop all streams
- max30001->max30001_Stop_ECG();
- if (partVersion == 1)
- max30001->max30001_Stop_PACE();
- if (partVersion == 1)
- max30001->max30001_Stop_BIOZ();
- max30001->max30001_Stop_RtoR();
- testing_max30001 = 0;
- // final results
- outputString("Result: ");
- _printPassFail(totalPass, 0, outputString);
-}
-

ECG, PACE, R-to-R heart peak, Bio-Z, Biopotential sensor Evaluation Kit MAX30001