MBED library software for the MAX30001 ECG, PACE, biopotential, bioimpedance, R-to-R peak sensor.
Dependencies: USBDevice max32630fthr SDFileSystem
Fork of MAX30001-MAX32630FTHR-ECG-EVKIT by
Diff: HSP/Devices/PushButton/PushButton.cpp
- Revision:
- 21:a789ee91137e
- Parent:
- 20:1151a3095605
- Child:
- 22:17aab62c9efa
diff -r 1151a3095605 -r a789ee91137e HSP/Devices/PushButton/PushButton.cpp
--- a/HSP/Devices/PushButton/PushButton.cpp Mon Jul 09 17:47:25 2018 +0300
+++ /dev/null Thu Jan 01 00:00:00 1970 +0000
@@ -1,81 +0,0 @@
-/*******************************************************************************
- * Copyright (C) 2016 Maxim Integrated Products, Inc., All Rights Reserved.
- *
- * Permission is hereby granted, free of charge, to any person obtaining a
- * copy of this software and associated documentation files (the "Software"),
- * to deal in the Software without restriction, including without limitation
- * the rights to use, copy, modify, merge, publish, distribute, sublicense,
- * and/or sell copies of the Software, and to permit persons to whom the
- * Software is furnished to do so, subject to the following conditions:
- *
- * The above copyright notice and this permission notice shall be included
- * in all copies or substantial portions of the Software.
- *
- * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS
- * OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
- * MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT.
- * IN NO EVENT SHALL MAXIM INTEGRATED BE LIABLE FOR ANY CLAIM, DAMAGES
- * OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE,
- * ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
- * OTHER DEALINGS IN THE SOFTWARE.
- *
- * Except as contained in this notice, the name of Maxim Integrated
- * Products, Inc. shall not be used except as stated in the Maxim Integrated
- * Products, Inc. Branding Policy.
- *
- * The mere transfer of this software does not imply any licenses
- * of trade secrets, proprietary technology, copyrights, patents,
- * trademarks, maskwork rights, or any other form of intellectual
- * property whatsoever. Maxim Integrated Products, Inc. retains all
- * ownership rights.
- *******************************************************************************
- */
-
-#include "PushButton.h"
-#include "Peripherals.h"
-
-PushButton::PushButton(PinName pin) : interruptButton(pin) {
- this->pin = pin;
-
- interruptButton.mode(PullUp);
- debouncingState = false;
- // Delay for initial pullup to take effect
- wait(0.01f);
- // Attach the address of the interrupt handler routine for pushbutton
- interruptButton.fall(callback(this, &PushButton::pb_hit_interrupt_fall));
-}
-
-bool PushButton::GetButtonFallState(void) {
- return buttonFallState;
-}
-
-void PushButton::SetButtonFallState(bool state) {
- buttonFallState = state;
-}
-
-void PushButton::clearButtonFallState(void) {
- buttonFallState = false;
-}
-
-int PushButton::Read(void) {
- return interruptButton.read();
-}
-
-void PushButton::pb_hit_interrupt_fall(void) {
- /* switch debouncing */
- if (!debouncingState)
- {
- timeout.attach(callback(this, &PushButton::pb_debounce_timeout), debounceTime);
- }
-}
-
-void PushButton::pb_debounce_timeout(void) {
- if (!interruptButton.read())
- {
- if (Peripherals::pushButton() != NULL){
- Peripherals::pushButton()->SetButtonFallState(true);
- }
- }
- debouncingState = false;
-}
-

ECG, PACE, R-to-R heart peak, Bio-Z, Biopotential sensor Evaluation Kit MAX30001