ZigBee AT Commands example for mbed XBeeLib By Digi

Dependencies:   XBeeLib mbed

This example shows how to read and change configuration parameters of either the local XBee module or a remote XBee module.

See Configuring local and remote modules chapter for more information.

Common Setup

Make sure you have a valid Example Common Setup

Example Setup

Application

You have to configure the remote device 64-bit address by customizing the REMOTE_NODE_ADDR64_MSB and REMOTE_NODE_ADDR64_LSB defines with the remote XBee module 64-bit address.

Running the example

Build and deploy the example to the mbed module.
Reset the mbed module so the example starts. You should see the example debug information through the debug interface configured in the 'Local Setup' chapter.
Once joined to the coordinator, the application will do following operations:

OperationXBee moduleparameterVerification
ReadlocalSLThe result is asserted against the known local module SL value. So just check the assertion passed
SetlocalNIClick 'discover remote devices' on the X-CTU connected to the remote. Should discover the local XBee module with the new NI (ni_example_local)
ReadremoteSLThe result is asserted against the known remote module SL value. So just check the assertion passed
SetremoteNIRefresh the 'NI' parameter in the X-CTU connected to the remote and check it has changed to the new NI (ni_example_remote)

config.h

Committer:
hbujanda
Date:
2016-07-29
Revision:
10:2ca09be89d07
Parent:
7:0fc2cb442d58

File content as of revision 10:2ca09be89d07:

/**
 * Copyright (c) 2015 Digi International Inc.,
 * All rights not expressly granted are reserved.
 *
 * This Source Code Form is subject to the terms of the Mozilla Public
 * License, v. 2.0. If a copy of the MPL was not distributed with this file,
 * You can obtain one at http://mozilla.org/MPL/2.0/.
 *
 * Digi International Inc. 11001 Bren Road East, Minnetonka, MN 55343
 * =======================================================================
 */

#ifndef __CONFIG_H_
#define __CONFIG_H_

/** Library configuration options */
#define ENABLE_LOGGING
#define ENABLE_ASSERTIONS
#define FRAME_BUFFER_SIZE           4
#define MAX_FRAME_PAYLOAD_LEN       128

#define SYNC_OPS_TIMEOUT_MS         2000

//#define RADIO_TX                NC /* TODO: specify your setup's Serial TX pin connected to the XBee module DIN pin */
//#define RADIO_RX                NC /* TODO: specify your setup's Serial RX pin connected to the XBee module DOUT pin */
//#define RADIO_RTS               NC /* TODO: specify your setup's Serial RTS# pin connected to the XBee module RTS# pin */
//#define RADIO_CTS               NC /* TODO: specify your setup's Serial CTS# pin connected to the XBee module CTS# pin */
//#define RADIO_RESET             NC /* TODO: specify your setup's GPIO (output) connected to the XBee module's reset pin */
//#define RADIO_SLEEP_REQ         NC /* TODO: specify your setup's GPIO (output) connected to the XBee module's SLEEP_RQ pin */
//#define RADIO_ON_SLEEP          NC /* TODO: specify your setup's GPIO (input) connected to the XBee module's ON_SLEEP pin */
//#define DEBUG_TX                NC /* TODO: specify your setup's Serial TX for debugging */
//#define DEBUG_RX                NC /* TODO: specify your setup's Serial RX for debugging (optional) */

#if !defined(RADIO_TX)
    #error "Please define RADIO_TX pin"
#endif

#if !defined(RADIO_RX)
    #error "Please define RADIO_RX pin"
#endif

#if !defined(RADIO_RESET)
    #define RADIO_RESET             NC
    #warning "RADIO_RESET not defined, defaulted to 'NC'"
#endif

#if defined(ENABLE_LOGGING)
    #if !defined(DEBUG_TX)
        #error "Please define DEBUG_TX"
    #endif
    #if !defined(DEBUG_RX)
        #define DEBUG_RX                NC
        #warning "DEBUG_RX not defined, defaulted to 'NC'"
    #endif
#endif

#endif /* __CONFIG_H_ */