This program connects to a few sensors via I2C and sends the data collected to a WNC Cellular Module which is located on an Avnet WNC-Shield card.

Dependencies:   FXOS8700CQ MODSERIAL mbed

/media/uploads/kevinkeryk/avnet_logo_tagline_rgb.png

Avnet Cellular IoT Instructions

  • One problematic area is setting the MY_SERVER_URL. When you copy the URL from the flow, you must make sure the MY_SERVER_URL is also set to the appropriate server. It can be either "run-east.att.io" or "run-west.att.io".

Useful Links

Adding Additional Sensors

The FLOW_DEVICE_NAME field must contain the name of the instance of the Virtual Starter Kit in FLOW you will be communicating with. Usually this is "vstarterkit001", but if you have problems communicating you can verify this is correct. Note: This device will not be created until you click the “Initialize” input on the Virtual Device tab of the Starter Kit project in FLOW. At that point, it becomes available in M2X and you can see it as the DEVICE SERIAL field under Devices as in the image below. /media/uploads/JMF/vstarterkit.png

Sensors: When executing, the FRDM-K64F board uploads sensor measurements to AT&T’s Flow environment every 5 seconds, using the Cellular shield board. You can adjust how often you want to do this by editing the SENSOR_UPDATE_INTERVAL_MS value in the header file.

Temperature and humidity: By default, the board reports readings from the HTS221 temperature and humidity sensor. These two values are sent to the HTTP IN /climate port in FLOW with field names “temp” and “humidity”. Temperature is in degrees Fahrenheit and humidity is a %. This default assignment is: iSensorsToReport = TEMP_HUMIDITY_ONLY;

Accelerometer: If you want to expand and use the onboard motion sensor, you can also send 3-axis accelerometer information from the board as “accelX”, “accelY”, and “accelZ”. This is useful if you want to know the stationary position of the board with regards to gravity, or whether it is in motion. These readings are in g’s. To send these values, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER;

PMOD Sensors: If you have a Silicon Labs sensor module that can plug into the PMOD connector on the Cellular shield, you are able to measure proximity, UV light, ambient visible and infrared light from the Si1145 sensor. This PMOD also has a temperature and humidity sensor, but in this case it is redundant. When enabled, the fields “proximity”, “light_uv”, “light_vis” and “light_ir” are also sent. To enable all these sensors, change the assignment to: iSensorsToReport = TEMP_HUMIDITY_ACCELEROMETER_PMODSENSORS;

Connecting the PMOD sensors: Because the pinouts do not align, the SiLabs PMOD sensor board cannot be plugged into the J10 PMOD receptacle on the shield directly. The following wiring instructions must be followed:

SignalJ10ShieldPMOD Color in the image below
VCCPin 6Pin 6Red
GNDPin 5Pin 5Black
SDAPin4Pin 3Green
SCLPin3Pin 2Yellow

/media/uploads/JMF/xyz.jpg

AT&T M2X and FLOW Instructions

M2X & FLOW Instructions

Link to AT&T M2X

M2X

Link to AT&T Flow

FLOW

Avnet WNC-Shield Information

Getting Started with the Avnet WNC-Shield Software

  • This project uses Revision 119 of the MBED library because of I2C implementation differences with the tip (Revision 121).
  • This project uses Revision 4 of the FXOS8700CQ library for sensors.

Easily Modifiable Parameters

Inside the mbed Avnet_ATT_Cellular_IOT project, the parameters needed to customize your board are in the config_me.h file.

  • FLOW parameters: This project assumes you are using a fork of the Starter Kit Base project, which is a reference design created using AT&T’s FLOW (https://flow.att.com) that allows the creation of online virtualization and other IoT functionality. The default parameters in the config_me.h file are done for a specific instance of this project. When you fork the original project, you get your own instance and it will have its own base address. At the bottom of the FLOW environment, when you click on the Endpoints tab, URL information that is specific to your instance is displayed. Of note is the Base URL. In the example below (as in the default mbed project), the Base URL is: https://run-west.att.io/1e464b19cdcde/774c88d68202/86694923d5bf28a/in/flow You have to take note of two parts of this address. The run-west.att.io part is the server URL, and you have to make sure the
  • MY_SERVER_URL field in config_me.h matches this. The rest of the base URL, in green above, needs to be pasted into the FLOW_BASE_URL field.

There is also a FLOW_INPUT_NAME field. This should match the name of the HTTP IN port in the FLOW project that you want to send sensor data to. The default is "/climate", as in the FLOW image below.

/media/uploads/JMF/sf.png

Where is the Binary I compiled

When the COMPILE button is pressed, it compiles your project and links it. The result is placed in the DOWNLOAD folder you use when downloading files from the Internet. It will be called AvnetATT_shape_hackathon_K64F.bin.

Additional Information on Compiling/Configuring

Comprehensive instructions can be found at: Quick Start Instructions

Committer:
fkellermavnet
Date:
Mon Aug 15 19:31:14 2016 +0000
Revision:
77:c65eae5b9958
Parent:
68:6e311c747045
Fixed some missing \r.; Added report of app version.; Added report of WNC firmware version.;

Who changed what in which revision?

UserRevisionLine numberNew contents of line
fkellermavnet 68:6e311c747045 1 /* ===================================================================
fkellermavnet 68:6e311c747045 2 Copyright © 2016, AVNET Inc.
fkellermavnet 68:6e311c747045 3
fkellermavnet 68:6e311c747045 4 Licensed under the Apache License, Version 2.0 (the "License");
fkellermavnet 68:6e311c747045 5 you may not use this file except in compliance with the License.
fkellermavnet 68:6e311c747045 6 You may obtain a copy of the License at
fkellermavnet 68:6e311c747045 7
fkellermavnet 68:6e311c747045 8 http://www.apache.org/licenses/LICENSE-2.0
fkellermavnet 68:6e311c747045 9
fkellermavnet 68:6e311c747045 10 Unless required by applicable law or agreed to in writing,
fkellermavnet 68:6e311c747045 11 software distributed under the License is distributed on an
fkellermavnet 68:6e311c747045 12 "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND,
fkellermavnet 68:6e311c747045 13 either express or implied. See the License for the specific
fkellermavnet 68:6e311c747045 14 language governing permissions and limitations under the License.
fkellermavnet 68:6e311c747045 15
fkellermavnet 68:6e311c747045 16 ======================================================================== */
JMF 2:0e2ef866af95 17
JMF 2:0e2ef866af95 18 #ifndef __WNC_CONTROL_H_
JMF 2:0e2ef866af95 19 #define __WNC_CONTROL_H_
JMF 2:0e2ef866af95 20
fkellermavnet 40:aec4d09fde23 21 static const unsigned WNC_TIMEOUT_MS = 10000;
JMF 2:0e2ef866af95 22
JMF 2:0e2ef866af95 23 // Core function that sends data to the WNC UART
JMF 2:0e2ef866af95 24 extern int send_wnc_cmd(const char * s, string ** r, int ms_timeout);
JMF 2:0e2ef866af95 25
JMF 2:0e2ef866af95 26 // Low level command functions
fkellermavnet 42:be4b9ee3a615 27 extern void at_init_wnc(bool hardReset = false);
JMF 2:0e2ef866af95 28 extern void at_sockopen_wnc(const string & ipStr, const char * port );
JMF 2:0e2ef866af95 29 extern void at_sockclose_wnc(void);
JMF 2:0e2ef866af95 30 extern int at_dnsresolve_wnc(const char * s, string * ipStr);
JMF 2:0e2ef866af95 31 extern void at_sockwrite_wnc(const char * s);
JMF 2:0e2ef866af95 32 extern unsigned at_sockread_wnc(string * pS, unsigned n, unsigned retries);
fkellermavnet 19:f89baed3bd6f 33 extern void at_at_wnc(void);
fkellermavnet 42:be4b9ee3a615 34 extern int at_send_wnc_cmd(const char * s, string ** r, int ms_timeout);
fkellermavnet 42:be4b9ee3a615 35 extern int check_wnc_ready(void);
JMF 2:0e2ef866af95 36
JMF 2:0e2ef866af95 37 // High level functions that attempt to correct for things going bad with the WNC
JMF 2:0e2ef866af95 38 extern void software_init_mdm(void);
JMF 2:0e2ef866af95 39 extern void resolve_mdm(void);
JMF 2:0e2ef866af95 40 extern void sockopen_mdm(void);
JMF 2:0e2ef866af95 41 extern void sockwrite_mdm(const char * s);
fkellermavnet 30:33be8e2992f3 42 extern unsigned sockread_mdm(string * sockData, int len, int retries);
JMF 2:0e2ef866af95 43 extern void sockclose_mdm(void);
fkellermavnet 77:c65eae5b9958 44 extern void display_modem_firmware_version(void);
JMF 2:0e2ef866af95 45
JMF 2:0e2ef866af95 46 #endif
JMF 2:0e2ef866af95 47
JMF 2:0e2ef866af95 48